Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Novel Concentrating Solar Weathering Apparatus for Experimental Validation of Multi-Modal Degradation Models

High-performance coatings for Concentrating Solar Power (CSP) receivers are subjected to remarkable environmental stressors during normal operations. Applied to the receiver tubes, these coatings serve to maximize the solar absorptivity of the receiver, transferring as much heat as possible from the solar collectors into the heat-transfer fluid (HTF). The lifecycle of these coatings is not well-defined, and the harsh operational conditions make them difficult to test. NREL has designed, built, and tested an apparatus to expose these samples to design levels of environmental stress and well beyond, into accelerated and destructive conditions. The chamber is actively cooled, monitored, and has the capability to supply humidification for cycling tests, allowing us to test multi-modal degradation and failure conditions at high temperature, high flux, and high humidity conditions. These conditions can catalyze high-temperature oxidation, mechanical degradation, and other modes of absorptivity loss seen in selective solar receiver coatings. The experimental data can feed lifecycle models for expensive and necessarily resilient materials, offering insights to aid maintenance schedules, technoeconomic analysis, and material industry performance benchmarks. This presentation will demonstrate the apparatus design and performance, as well as initial results for aging on a selective receiver coating.

14 SOLAR ENERGY↗

PBX 9502 Multimode Damage Accumulation Cycles-to-Failure Study

In FY13, we performed a detailed cycles-to-failure study of PBX 9502 using 3- point bend specimens. In that study we examined the effect of temperature and cyclic frequency on the failure behavior of PBX 9502. We identified cycles-to-failure curves for samples tested at -20°C, ~19°C and 50°C and at cyclic frequencies of 0.0001 up to 1-Hz. We also did cyclic conditioning of parts in an effort to establish damage accumulation criteria that could then be used in predictive models. As follow-on to that work, in FY14 we have added multimode cycles-to-failure to our test suite. Work this year re-established the baseline cycles-to-failure behavior of the PBX 9502 material tested round ~19°C at 1-Hz and also looked at damage accumulation under a multimode loading environment. This fresh baseline development was performed to remove any time related or test rig related variables. The multimode loading was done because real-world applications are not mono-modal and we desire for our predictive capability to be robust and include more complex, realistic scenarios. In the following sections we briefly describe the test setup, we provide a summary of the new baseline results and we show the multimode cycles-to-failure data and how it compares to the mono-modal test data.

42 ENGINEERING↗

MO-C-17A-05: A Three-Dimensional Head-And-Neck Phantom for Validation of Kilovoltage- and Megavoltage-Based Deformable Image Registration

Purpose: To develop a three-dimensional (3D) deformable head-and-neck (H and N) phantom with realistic tissue contrast for both kilovoltage and megavoltage computed tomography and use it to objectively evaluate deformable image registration (DIR) algorithms. Methods: The phantom represents H and N patient anatomy. It is constructed from thermoplastic, which becomes pliable in boiling water, and hardened epoxy resin. Using a system of additives, the Hounsfield unit (HU) values of these materials were tuned to mimic anatomy for both kilovoltage (kV) and megavoltage (MV) imaging. The phantom opened along a sagittal midsection to reveal nonradiopaque markers, which were used to characterize the phantom deformation. The deformed and undeformed phantom was scanned with kV and MV computed tomography. Additionally, a calibration curve was created to change the HUs of the MV scans to be similar to kV HUs, (MC). The extracted ground-truth deformation was then compared to the results of two commercially available DIR algorithms, from Velocity Medical Solutions and MIM Software. Results: The phantom produced a 3D deformation, representing neck flexion, with a magnitude of up to 8 mm and was able represent tissue HUs for both kV and MV imaging modalities. The two tested deformation algorithms yielded vastly different results. For kV-kV registration, MIM made the lowest mean error, and Velocity made the lowest maximum error. For MV-MV, kV-MV, and kV-MC Velocity produced both the lowest mean and lowest maximum errors. Conclusion: The application of DIR across different imaging modalities is particularly difficult, due to differences in tissue HUs and the presence of imaging artifacts. For this reason, DIR algorithms must be validated specifically for this purpose. The developed H and N phantom is an effective tool for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A three-dimensional head-and-neck phantom for validation of multimodality deformable image registration for adaptive radiotherapy

Purpose: To develop a three-dimensional (3D) deformable head-and-neck (H and N) phantom with realistic tissue contrast for both kilovoltage (kV) and megavoltage (MV) imaging modalities and use it to objectively evaluate deformable image registration (DIR) algorithms. Methods: The phantom represents H and N patient anatomy. It is constructed from thermoplastic, which becomes pliable in boiling water, and hardened epoxy resin. Using a system of additives, the Hounsfield unit (HU) values of these materials were tuned to mimic anatomy for both kV and MV imaging. The phantom opens along a sagittal midsection to reveal radiotransparent markers, which were used to characterize the phantom deformation. The deformed and undeformed phantoms were scanned with kV and MV imaging modalities. Additionally, a calibration curve was created to change the HUs of the MV scans to be similar to kV HUs, (MC). The extracted ground-truth deformation was then compared to the results of two commercially available DIR algorithms, from Velocity Medical Solutions and MIM software. Results: The phantom produced a 3D deformation, representing neck flexion, with a magnitude of up to 8 mm and was able to represent tissue HUs for both kV and MV imaging modalities. The two tested deformation algorithms yielded vastly different results. For kV–kV registration, MIM produced mean and maximum errors of 1.8 and 11.5 mm, respectively. These same numbers for Velocity were 2.4 and 7.1 mm, respectively. For MV–MV, kV–MV, and kV–MC Velocity produced similar mean and maximum error values. MIM, however, produced gross errors for all three of these scenarios, with maximum errors ranging from 33.4 to 41.6 mm. Conclusions: The application of DIR across different imaging modalities is particularly difficult, due to differences in tissue HUs and the presence of imaging artifacts. For this reason, DIR algorithms must be validated specifically for this purpose. The developed H and N phantom is an effective tool for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: PLASTIMATCH MABS, an open source tool for automatic image segmentation

Purpose: Multiatlas based segmentation is largely used in many clinical and research applications. Due to its good performances, it has recently been included in some commercial platforms for radiotherapy planning and surgery guidance. Anyway, to date, a software with no restrictions about the anatomical district and image modality is still missing. In this paper we introduce PLASTIMATCH MABS, an open source software that can be used with any image modality for automatic segmentation. Methods: PLASTIMATCH MABS workflow consists of two main parts: (1) an offline phase, where optimal registration and voting parameters are tuned and (2) an online phase, where a new patient is labeled from scratch by using the same parameters as identified in the former phase. Several registration strategies, as well as different voting criteria can be selected. A flexible atlas selection scheme is also available. To prove the effectiveness of the proposed software across anatomical districts and image modalities, it was tested on two very different scenarios: head and neck (H&N) CT segmentation for radiotherapy application, and magnetic resonance image brain labeling for neuroscience investigation. Results: For the neurological study, minimum dice was equal to 0.76 (investigated structures: left and right caudate, putamen, thalamus, and hippocampus). For head and neck case, minimum dice was 0.42 for the most challenging structures (optic nerves and submandibular glands) and 0.62 for the other ones (mandible, brainstem, and parotid glands). Time required to obtain the labels was compatible with a real clinical workflow (35 and 120 min). Conclusions: The proposed software fills a gap in the multiatlas based segmentation field, since all currently available tools (both for commercial and for research purposes) are restricted to a well specified application. Furthermore, it can be adopted as a platform for exploring MABS parameters and as a reference implementation for comparing against other segmentation algorithms.

60 APPLIED LIFE SCIENCES↗

Anode Upcycling via Tailored Solvent Treatment

To achieve a truly closed-loop direct recycling process for lithium-ion batteries, all component materials must be recovered. To date, direct recycling method development has primarily focused on the high-value transition-metal cathode materials, while the inherently lower-value graphite has been challenging to recover in a cost-effective manner. However, end-of-life graphite contains a unique engineered value due to the presence of the solid electrolyte interphase (SEI). Growth of the SEI during the cell's active lifetime stabilizes the electronically reactive graphite surface through an irreversible consumption of Li, and thus necessitates both excess lithiation of the cathode and a costly and time-intensive formation procedure during manufacturing. An optimized pre-formed SEI that capitalizes on existing SEI components from end-of-life batteries has the potential to significantly reduce cathode lithiation requirements and eliminate the critical bottleneck of formation cycling during cell remanufacturing. Further, retaining Li at the anode obviates the need for a separate Li leaching and recovery step, improving the overall efficiency of the direct recycling line. In this work, we present a novel approach to "upcycling" spent graphite through use of tailored chemical treatment to remove adverse (i.e., highly resistive and/or poorly passivating) SEI species while retaining beneficially passivating components. We have explored a rational set of solvents spanning a range of polarity, proticity, and molecular size to evaluate structure-property-performance relationships between applied solvent(s), removed and remaining SEI species, and electrochemical response of the resulting graphite product. Further, we have developed and optimized a robust and holistic analysis procedure that couples symmetric-cell electrochemical testing, multi-modal materials characterization, and advanced electrochemical modeling. These analysis results inform a set of correlative metrics for graphite performance relative to both solvent properties and upcycled SEI composition. We demonstrate effective tunability in the residual SEI composition by varying solvent identity and concentration, and report on several promising solvent systems that achieve comparable or performance to pristine graphite.

anode recycling↗

SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and the PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.

60 APPLIED LIFE SCIENCES↗

Digital Image Correlation as an Experimental Modal Analysis Capability

Digital image correlation (DIC) is an established test technique in several fields including quasi-static displacement measurements. Recently there has been growing interest in using DIC to measure structural dynamic response and even extract modal parameters from that information. Although high-speed cameras have become more ubiquitous, there are no commercial end-to-end packages for modal analysis based on image data, particularly when combined with traditional data acquisition systems. As such, the practitioner is left to develop several key data processing capabilities, hardware interface equipment, and testing practices themselves. This work highlights several practical aspects that have been encountered while establishing DIC as a viable modal testing capability in a laboratory environment.

47 OTHER INSTRUMENTATION↗

MODAL FREQUENCY TRACKING: Performance Analysis on Noisy Experimental Ground Test Data

Mechanical devices operating in an environment contaminated by noise, uncertainties, and extraneous disturbances lead to low signal-to-noise-ratios creating an extremely challenging signal processing problem—especially for on-line, realtime, in-flight application. In this report, we discuss a model-based approach to incorporate physical device features into a dynamic structure that can be used to perform on-line tracking of modal frequencies. The approach we take, after pre-processing the raw measurement data, is to obtain a representation of the structural device under test that captures its underlying response to a suite of excitations and operating conditions. One approach is to apply modern system identification techniques based on stochastic subspace methods capable of both: (1) identifying the underlying black-box structure enabling the extraction of structural modes that can be used for analysis; and (2) modal tracking under continued vibrational excitation as in a real-time, in-flight like environment. The vibrational signature of the structural device is measured directly using a suite of tri-axial accelerometers characterizing a multiple input/multiple output (MIMO) dynamic system. In this analysis, we have 15 tri-axial accelerometer measurements or 45 total output channels along with a single excitation also measured with a tri-axial accelerometer providing a 3-input system for processing. We initially describe the experiment and then briefly develop the necessary background in stochastic subspace realization, discuss the algorithm and apply it to the isolated structural device, first, characterized by the set of noisy MIMO accelerometer measurements extracting the modal model from the data (subspace identification), extract the unique modal frequencies (modal coordinate transformation), track their evolution (real-time tracker) to evaluate the overall performance of the processor. Next we evaluate processor performance when the structural device is incorporated into a flight vehicle for further performance analysis. We summarize the results and predict performance.

42 ENGINEERING↗

Diffusion-Weighted MRI for Nodal Staging of Head and Neck Squamous Cell Carcinoma: Impact on Radiotherapy Planning

Purpose: To evaluate the use of diffusion-weighted magnetic resonance imaging (DW-MRI) for nodal staging and its impact on radiotherapy (RT) planning. Methods and Materials: Twenty-two patients with locally advanced head and neck squamous cell carcinoma underwent contrast-enhanced computed tomography (CT), as well as MRI (with routine and DW sequences) prior to neck dissection. After topographic correlation, lymph nodes were evaluated microscopically with prekeratin immunostaining. Pathology results were correlated with imaging findings and an RT planning study was performed for these surgically treated patients. One set of target volumes was based on conventional imaging only, and another set was based on the corresponding DW-MRI images. A third reference set was contoured based solely on pathology results. Results: A sensitivity of 89% and a specificity of 97% per lymph node were found for DW-MRI. Nodal staging agreement between imaging and pathology was significantly stronger for DW-MRI (kappa = 0.97; 95% confidence interval [CI], 0.84-1.00) than for conventional imaging (kappa = 0.56; 95% CI, 0.16-0.96; p = 0.019, by McNemar's test). For both imaging modalities, the absolute differences between RT volumes and those obtained by pathology were calculated. Using an exact paired Wilcoxon test, the observed difference was significantly larger for conventional imaging than for DW-MRI for nodal gross tumor volume (p = 0.0013), as well as for nodal clinical target volume (p = 0.0415) delineation. Conclusions: These results suggest that DW-MRI is superior to conventional imaging for preradiotherapy nodal staging of head and neck squamous cell carcinoma, and provides a potential impact on organsparing and tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural Health Monitoring of Nuclear Spent Fuel Storage Facilities

Interim storage of spent nuclear fuel from reactor sites has gained additional importance and urgency for resolving waste-management-related technical issues. To ensure that nuclear power remains clean energy, monitoring has been identified by DOE as a high priority cross-cutting need, necessary to determine and predict the degradation state of the systems, structures, and components (SSCs) important to safety (ITS). Therefore, nondestructive structural condition monitoring becomes a need to be installed on existing or to be integrated into future storage system to quantify the state of health or to guarantee the safe operation of nuclear power plants (NPPs) during their extended life span. In this project, the lead university and the collaborating national laboratory teamed to develop a nuclear structural health monitoring (n-SHM) system based on in-situ piezoelectric sensing technologies that can monitor structural degradation and aging for nuclear spent fuel DCSS and similar structures. We also aimed to identify and quantify possible influences of nuclear spent fuel environment (temperature and radiation) to the piezoelectric sensor system and come up with adequate solutions and guidelines therefore. We have therefore developed analytical model for piezoelectric based n-SHM methods, with considerations of temperature and irradiation influence on the model of sensing and algorithms in acoustic emission (AE), guided ultrasonic waves (GUW), and electromechanical impedance spectroscopy (EMIS). On the other side, experimentally the temperature and irradiation influence on the piezoelectric sensors and sensing capabilities were investigated. Both short-term and long-term irradiation investigation with our collaborating national laboratory were performed. Moreover, we developed multi-modal sensing, validated in laboratory setup, and conducted the testing on the We performed multi-modal sensing development, verification and validation tests on very complex structures including a medium-scale vacuum drying chamber and a small-scale mockup canister available for the desired testing. Our work developed the potential candidate for long term structural health monitoring of spent fuel canister through piezoelectric wafer sensors and provided the sensing methodologies based on AE and GUW methodologies. It overall provides an innovative system and methodology for enhancing the safe operation of nuclear power plant. All major accomplishments planned in the original proposal were successfully achieved.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel assembly shaker and truck test simulation

This study continues the modeling support of the SNL shaker table task from 2013 and includes analysis of the SNL 2014 truck test campaign. Detailed finite element models of the fuel assembly surrogate used by SNL during testing form the basis of the modeling effort. Additional analysis was performed to characterize and filter the accelerometer data collected during the SNL testing. The detailed fuel assembly finite element model was modified to improve the performance and accuracy of the original surrogate fuel assembly model in an attempt to achieve a closer agreement with the low strains measured during testing. The revised model was used to recalculate the shaker table load response from the 2013 test campaign. As it happened, the results remained comparable to the values calculated with the original fuel assembly model. From this it is concluded that the original model was suitable for the task and the improvements to the model were not able to bring the calculated strain values down to the extremely low level recorded during testing. The model needs more precision to calculate strains that are so close to zero. The truck test load case had an even lower magnitude than the shaker table case. Strain gage data from the test was compared directly to locations on the model. Truck test strains were lower than the shaker table case, but the model achieved a better relative agreement of 100-200 microstrains (or 0.0001-0.0002 mm/mm). The truck test data included a number of accelerometers at various locations on the truck bed, surrogate basket, and surrogate fuel assembly. This set of accelerometers allowed an evaluation of the dynamics of the conveyance system used in testing. It was discovered that the dynamic load transference through the conveyance has a strong frequency-range dependency. This suggests that different conveyance configurations could behave differently and transmit different magnitudes of loads to the fuel even when traveling down the same road at the same speed. It is recommended that the SNL conveyance system used in testing be characterized through modal analysis and frequency response analysis to provide context and assist in the interpretation of the strain data that was collected during the truck test campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Further developments of capillary absorption spectrometers using small hollow-waveguide fibers

Our objective is to enhance quantification of stable carbon and oxygen isotope ratios to better than 1‰ relative isotope precision for sample sizes < 1 pico-mole. A newer variant Capillary Absorption Spectrometer (CAS) is described using a proprietary linear-taper hollow waveguide in conjunction with wavelength and frequency modulation techniques of tunable laser absorption spectrometry. Previous work used circular capillaries with uniform 1 mm ID to measure 13C/12C ratios with ≥ 20 pico-mole samples to ≤ 10 ppm (1‰ precision against standards) [1]. While performing fairly well, it generated residual modal noise due to multipath propagation in the hollow-waveguides (HWGs). This system has been utilized with laser ablation-catalytic combustion techniques to analyze small resolution (~ 25 μm spot diameter) laser ablation events on solids. Using smaller ID capillary waveguides could improve detection limits and spatial resolutions. Reducing an IR compatible hollow waveguide’s inner diameter (ID) to < 300 μm, reduces modal noise significantly for mid-IR operation, but feedback noise with high gain semiconductor lasers can become problematic. A proprietary linear-taper small waveguide (mean ID = 0.35 mm, L = 1 m) was tested to understand whether modal noise and optical feedback effects could be simultaneously reduced. We see better mode filtering and, significant reductions of feedback noise under favorable coupling of a multi-spatial mode QC laser to the smaller ID of the linear-tapered HWG. We demonstrate that better modal coupling operation is consistent with Liouville’s theorem, where greater suppression of feedback from spurious scatter within the HWG occurs by injecting the laser into the smaller ID port. Our progress on developing lighter weight, potentially fieldable alternatives to Isotope Ratio Mass Spectrometers (IRMS) with a small volume (≤ 0.1 cm3) CAS system will be discussed and compared to other competitive systems.

Kelly, James F.↗