Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SMART Mobility. Multi-Modal Freight Capstone Report

The U.S. Department of Energy’s Systems and Modeling for Accelerated Research in Transportation (SMART) Mobility Consortium is a multiyear, multi-laboratory collaborative, managed by the Energy Efficient Mobility Systems Program of the Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office, dedicated to further understanding the energy implications and opportunities of advanced mobility technologies and services. The first three-year research phase of SMART Mobility occurred from 2017 through 2019, and included five research pillars: Connected and Automated Vehicles, Mobility Decision Science, Multi-Modal Freight, Urban Science, and Advanced Fueling Infrastructure. A sixth research thrust integrated aspects of all five pillars to develop a SMART Mobility Modeling Workflow to evaluate new transportation technologies and services at scale. This report summarizes the work of the Multi-Modal Freight Pillar. The Multi Modal Freight Pillar’s objective is to assess the effectiveness of emerging freight movement technologies and understand the impacts of the growing trends in consumer spending and e-commerce on parcel movement considering mobility, energy, and productivity. For information about the other Pillars and about the SMART Mobility Modeling Workflow, please refer to the relevant pillar’s Capstone Report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of Modal Parameters of an Offshore Wind Turbine to Operational and Environmental Factors: A Numerical Study: Preprint

The dynamics and performance of offshore wind turbines are sensitive to their structural properties, and in particular their modal parameters, i.e., natural frequencies, damping ratios and mode shapes. In this work, the sensitivity of the modal parameters of a 6 MW fixed-bottom offshore wind turbine to different operational and environmental conditions including wind speed and rotor speed is investigated. Effect of blade flexibility on the modal parameters of the system is also studied.

aerodynamic damping↗

Interface Modalities

Because digital maps are dynamic in their output and responsive to user input, a central yet relatively recent concern in modern cartography and visualization is the design of the user interface that connects the user to the map (and thus to the information contained within the map). Digital maps are primarily driven by point-and-clicks of a mouse and primarily display the results of the interaction visually on a screen. However, there exist several other modalities that can be employed to interact with a digital map. While visual output and mouse input will likely endure, novel approaches for haptic and audio feedback, gesture and speech input, and other modalities have been developed, particularly in response to the demands of diverse uses, and needs of diverse users of maps. These comprise the multiple interface modalities associated with cartography and geographic visualization.

58 GEOSCIENCES↗

The Adoption of New Adjuvant Radiation Therapy Modalities Among Medicare Beneficiaries With Breast Cancer: Clinical Correlates and Cost Implications

Purpose: New radiation therapy modalities have broadened treatment options for older women with breast cancer, but it is unclear how clinical factors, geographic region, and physician preference affect the choice of radiation therapy modality. Methods and Materials: We used the Surveillance, Epidemiology, and End Results-Medicare database to identify women diagnosed with stage I-III breast cancer from 1998 to 2007 who underwent breast-conserving surgery. We assessed the temporal trends in, and costs of, the adoption of intensity modulated radiation therapy (IMRT) and brachytherapy. Using hierarchical logistic regression, we evaluated the relationship between the use of these new modalities and patient and regional characteristics. Results: Of 35,060 patients, 69.9% received conventional external beam radiation therapy (EBRT). Although overall radiation therapy use remained constant, the use of IMRT increased from 0.0% to 12.6% from 1998 to 2007, and brachytherapy increased from 0.7% to 9.0%. The statistical variation in brachytherapy use attributable to the radiation oncologist and geographic region was 41.4% and 9.5%, respectively (for IMRT: 23.8% and 22.1%, respectively). Women undergoing treatment at a free-standing radiation facility were significantly more likely to receive IMRT than were women treated at a hospital-based facility (odds ratio for IMRT vs EBRT: 3.89 [95% confidence interval, 2.78-5.45]). No such association was seen for brachytherapy. The median radiation therapy cost per treated patient increased from $5389 in 2001 to $8539 in 2007. Conclusions: IMRT and brachytherapy use increased substantially from 1998 to 2007; overall, radiation therapy costs increased by more than 50%. Radiation oncologists played an important role in treatment choice for both types of radiation therapy, whereas geographic region played a bigger role in the use of IMRT than brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

National Cancer Data Base Analysis of Radiation Therapy Consolidation Modality for Cervical Cancer: The Impact of New Technological Advancements

Purpose: To utilize the National Cancer Data Base to evaluate trends in brachytherapy and alternative radiation therapy utilization in the treatment of cervical cancer, to identify associations with outcomes between the various radiation therapy modalities. Methods and Materials: Patients with International Federation of Gynecology and Obstetrics stage IIB-IVA cervical cancer in the National Cancer Data Base who received treatment from January 2004 to December 2011 were analyzed. Overall survival was estimated by the Kaplan-Meier method. Univariate and multivariable analyses were performed to identify factors associated with type of boost radiation modality used and its impact on survival. Results: A total of 7654 patients had information regarding boost modality. A predominant proportion of patients were Caucasian (76.2%), had stage IIIB (48.9%) disease with squamous (82.0%) histology, were treated at academic/research centers (47.7%) in the South (34.8%), and lived 0 to 5 miles (27.9%) from the treating facility. A majority received brachytherapy (90.3%). From 2004 to 2011, brachytherapy use decreased from 96.7% to 86.1%, whereas intensity modulated radiation therapy (IMRT) and stereotactic body radiation therapy (SBRT) use increased from 3.3% to 13.9% in the same period (P<.01). Factors associated with decreased brachytherapy utilization included older age, stage IVA disease, smaller tumor size, later year of diagnosis, lower-volume treatment centers, and facility type. After controlling for significant factors from survival analyses, IMRT or SBRT boost resulted in inferior overall survival (hazard ratio, 1.86; 95% confidence interval, 1.35-2.55; P<.01) as compared with brachytherapy. In fact, the survival detriment associated with IMRT or SBRT boost was stronger than that associated with excluding chemotherapy (hazard ratio, 1.61′ 95% confidence interval, 1.27-2.04′ P<.01). Conclusions: Consolidation brachytherapy is a critical treatment component for locally advanced cervical cancer; however, there has been declining utilization of brachytherapy. Increased use of IMRT and SBRT boost coupled with increased mortality risk should raise concerns about utilizing these approaches over brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel strategies for modal-based structural material identification

Here, we present modal-based methods for model calibration in structural dynamics, and address several key challenges in the solution of gradient-based optimization problems with eigenvalues and eigenvectors, including the solution of singular Helmholtz problems encountered in sensitivity calculations, non-differentiable objective functions caused by mode swapping during optimization, and cases with repeated eigenvalues. Unlike previous literature that relied on direct solution of the eigenvector adjoint equations, we present a parallel iterative domain decomposition strategy (Adjoint Computation via Modal Superposition with Truncation Augmentation) for the solution of the singular Helmholtz problems. For problems with repeated eigenvalues we present a novel Mode Separation via Projection algorithm, and in order to address mode swapping between inverse iterations we present a novel Injective mode ordering metric. We present the implementation of these methods in a massively parallel finite element framework with the ability to use measured modal data to extract unknown structural model parameters from large complex problems. A series of increasingly complex numerical examples are presented that demonstrate the implementation and performance of the methods in a massively parallel finite element framework [7], [5], using gradient-based optimization techniques in the Rapid Optimization Library (ROL) [21].

36 MATERIALS SCIENCE↗

Preparing for the next pandemic via transfer learning from existing diseases with hierarchical multi-modal BERT: a study on COVID-19 outcome prediction

Abstract Developing prediction models for emerging infectious diseases from relatively small numbers of cases is a critical need for improving pandemic preparedness. Using COVID-19 as an exemplar, we propose a transfer learning methodology for developing predictive models from multi-modal electronic healthcare records by leveraging information from more prevalent diseases with shared clinical characteristics. Our novel hierarchical, multi-modal model ( $${\textsc {TransMED}}$$ T R A N S MED ) integrates baseline risk factors from the natural language processing of clinical notes at admission, time-series measurements of biomarkers obtained from laboratory tests, and discrete diagnostic, procedure and drug codes. We demonstrate the alignment of $${\textsc {TransMED}}$$ T R A N S MED ’s predictions with well-established clinical knowledge about COVID-19 through univariate and multivariate risk factor driven sub-cohort analysis. $${\textsc {TransMED}}$$ T R A N S MED ’s superior performance over state-of-the-art methods shows that leveraging patient data across modalities and transferring prior knowledge from similar disorders is critical for accurate prediction of patient outcomes, and this approach may serve as an important tool in the early response to future pandemics.

59 BASIC BIOLOGICAL SCIENCES↗

Accounting for water-column variability in shallow-water waveguide characterizations based on modal eigenvalues

The influence of water-column variability on the characterization of shallow-water waveguides using modal eigenvalue information is considered. This work is based on the relationship between the acoustic pressure field in shallow water and the depth-dependent Green's function through the Hankel transform. In many practical situations, the Hankel transform can be approximated by a Fourier transform, in which case the Green's function is approximated by a horizontal wave number spectrum with discrete peaks corresponding with individual modal eigenvalues. In turn, the wave number data can be used in inverse algorithms to determine geoacoustic properties of the waveguide. Wave number spectra are estimated from measurements of a point-source acoustic field on a horizontal aperture array in the water column. For range-dependent waveguides, techniques analogous to using a short-time Fourier transform are employed to estimate range-dependent wave number spectra. In this work, water-column variability due to linear internal waves and mesoscale features are considered. It will be shown that these two types of variability impact the estimation of range-dependent modal eigenvalues in different ways. Approaches for accounting for these different types of variability will be discussed as they apply to waveguide characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative multi-modal NDT data analysis

A single NDT technique is often not adequate to provide assessments about the integrity of test objects with the required coverage or accuracy. In such situations, it is often resorted to multi-modal testing, where complementary and overlapping information from different NDT techniques are combined for a more comprehensive evaluation. Multi-modal material and defect characterization is an interesting task which involves several diverse fields of research, including signal and image processing, statistics and data mining. The fusion of different modalities may improve quantitative nondestructive evaluation by effectively exploiting the augmented set of multi-sensor information about the material. It is the redundant information in particular, whose quantification is expected to lead to increased reliability and robustness of the inspection results. There are different systematic approaches to data fusion, each with its specific advantages and drawbacks. In our contribution, these will be discussed in the context of nondestructive materials testing. A practical study adopting a high-level scheme for the fusion of Eddy Current, GMR and Thermography measurements on a reference metallic specimen with built-in grooves will be presented. Results show that fusion is able to outperform the best single sensor regarding detection specificity, while retaining the same level of sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An ECT/ERT dual-modality sensor for oil-water two-phase flow measurement

This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of multi-modal plasma responses to applied magnetic perturbations using the plasma reluctance

Using the plasma reluctance, the Ideal Perturbed Equilibrium Code is able to efficiently identify the structure of multi-modal magnetic plasma response measurements and the corresponding impact on plasma performance in the DIII-D tokamak. Recent experiments demonstrated that multiple kink modes of comparable amplitudes can be driven by applied nonaxisymmetric fields with toroidal mode number n = 2. This multi-modal response is in good agreement with ideal magnetohydrodynamic models, but detailed decompositions presented here show that the mode structures are not fully described by either the least stable modes or the resonant plasma response. This paper identifies the measured response fields as the first eigenmodes of the plasma reluctance, enabling clear diagnosis of the plasma modes and their impact on performance from external sensors. The reluctance shows, for example, how very stable modes compose a significant portion of the multi-modal plasma response field and that these stable modes drive significant resonant current. Finally, this work is an overview of the first experimental applications using the reluctance to interpret the measured response and relate it to multifaceted physics, aimed towards providing the foundation of understanding needed to optimize nonaxisymmetric fields for independent control of stability and transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Genomic discovery of an evolutionarily programmed modality for small-molecule targeting of an intractable protein surface

The vast majority of intracellular protein targets are refractory toward small-molecule therapeutic engagement, and additional therapeutic modalities are needed to overcome this deficiency. Here, the identification and characterization of a natural product, WDB002, reveals a therapeutic modality that dramatically expands the currently accepted limits of druggability. WDB002, in complex with the FK506-binding protein (FKBP12), potently and selectively binds the human centrosomal protein 250 (CEP250), resulting in disruption of CEP250 function in cells. The recognition mode is unprecedented in that the targeted domain of CEP250 is a coiled coil and is topologically featureless, embodying both a structural motif and surface topology previously considered on the extreme limits of “undruggability” for an intracellular target. Structural studies reveal extensive protein–WDB002 and protein–protein contacts, with the latter being distinct from those seen in FKBP12 ternary complexes formed by FK506 and rapamycin. Outward-facing structural changes in a bound small molecule can thus reprogram FKBP12 to engage diverse, otherwise “undruggable” targets. The flat-targeting modality demonstrated here has the potential to expand the druggable target range of small-molecule therapeutics. As CEP250 was recently found to be an interaction partner with the Nsp13 protein of the SARS-CoV-2 virus that causes COVID-19 disease, it is possible that WDB002 or an analog may exert useful antiviral activity through its ability to form high-affinity ternary complexes containing CEP250 and FKBP12.

59 BASIC BIOLOGICAL SCIENCES↗

HIGH-CONTRAST IMAGING VIA MODAL CONVERGENCE OF DEFORMABLE MIRROR

For extremely high contrast imaging, such as direct observation of faint stellar companions, an adaptive optics system is required to produce low-halo and low-speckle regions in the focal plane. A method for deformable mirror control is proposed to achieve this goal. The method relies on a modal convergence of the deformable mirror driven by a focal-plane metric. The modal sets are derived from the Walsh functions. The Walsh-function modes serve two purposes: the expansion of the actuator displacements and the expansion of the phase functions. Taking advantage of the unique properties of the modal functions, a universal control algorithm is devised for the realization of high-contrast focal planes with and without the help of conventional coronagraphy. Numerical modeling is conducted to simulate complete imaging systems under various scenarios. It is shown that the proposed method reliably produces high-contrast focal planes using either a segmented or a membrane mirror. In the presence of random aberration the method is shown to be able to maintain high-contrast focal planes. Requiring neither retrieval of electric fields nor detailed knowledge of the deformable mirrors, this technique may allow high-contrast imaging in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anatomy of bispectra in general single-field inflation — Modal expansions

We discuss bispectra of single-field inflationary models described by general Lorentz invariant Lagrangians that are at most first order in field derivatives, including the fast-roll models investigated by Noller and Magueijo. Based on a factor analysis, we identify the least correlated basic contributions to the general shape and show quantitatively which templates provide a good approximation. We compute how relative contributions of basic shapes to the total bispectrum scale as slow roll is relaxed. To enable future comparison with CMB observations, we provide a modal expansion of these non-separable bispectra in Fourier space, employing the formalism by Fergusson et al. Convergence is rapid, usually better than ninety-five percent with less than thirty modes, due to the smoothness of these primordial shapes. Truncated polynomial modal expansions have restrictions, which we highlight using an example with slow convergence. The particular shape originates from particle production during inflation (common in trapped inflation) and entails both localized and oscillatory features. We show that this shape can be recovered efficiently using a Fourier basis and outline the prospect of future model parameter extraction and N-body simulations based on modal techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Automotive Intrusion Detection Through Multi-Modal Fusion: A CAN FD-LiDAR Approach

As vehicles become smarter and more autonomous, they increasingly depend on advanced sensors and communication technologies to operate securely. However, such growing dependence on technology—whether it’s CAN (Controller Area Network) for internal communication or LiDAR (Light Detection and Ranging) for sensing the world around them—also expands the attack surface for the types of cyber attacks. Traditional intrusion detection systems (IDS) typically monitor these systems in isolation, limiting their ability to detect sophisticated, crosssystem attacks. To address this, we propose a multi-modal fusion approach that combines real-world CAN FD signals (from the HCRL dataset) with LiDAR features (from the nuScenes dataset) to enhance attack detection. Our method employs a twostage ensemble approach. Calibrated XGBoost and LightGBM models initially process CAN FD (Fuzzing Data) and LiDAR data independently, detecting timing anomalies and space abnormalities. They are subsequently logarithmically combined with a logistic regression meta-model along with 17 engineered features capturing cross-modal behavior, prediction conflicts, and nonlinear interactions. This approach achieves an AUC of 0.87 and an F1-score of 0.82, surpassing single-modality baselines and early fusion methods, at merely 2 ms inference latency. Compared with deep learning competitors, it is 3 times more efficient, providing a lightweight, interpretable, and real time solution to automotive cybersecurity.

97 MATHEMATICS AND COMPUTING↗

Curation and Dissemination of Complex Multi-Modal Datasets for Radiation Detection, Localization, and Tracking

The PANDAWN sensor network in Chicago, IL, is a state-of-the-art testbed for networked, multi-modal sensing. It integrates AI/data science methods into its operation, from data acquisition to automated data labeling and curation workflows. The curation and dissemination of diverse multi-modal datasets will enable the development of new radiological/nuclear (R/N) detection, localization, and tracking algorithms and methods relevant across the nonproliferation mission space. This article first introduces the PANDAWN sensor network and the features that make it stand out from previous multi-modal data acquisition efforts. We then review the various data streams acquired on the PANDAWN nodes and present the implementation of an automated data curation pipeline that includes the labeling of radiation and contextual data streams. Here, we finally provide a short overview of different studies that leveraged the curated datasets.

Data curation↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗