Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Microscopy Transfer System to Protect Atmosphere‐Sensitive Materials for Scanning Electron Microscopy Characterization

Atmosphere- and/or moisture-sensitive materials can be challenging to characterize using electron microscopy techniques due to sample preparation workflows that generally require exposure to ambient conditions. Here, we describe a novel preparation method that uses aluminum foil in combination with a commercial cryo-EM transfer system to circumvent undesired exposure to the atmosphere. First, hygroscopic MgCl 2 was used as a model material, and prepared samples (both protected and unprotected) were placed in a controlled-humidity environment (> 80% relative humidity) for various exposure lengths (circa seconds to hours). Following this, the effectiveness of the sample preparation method was determined by comparing qualitative photos and quantitative X-ray diffraction patterns between the two sample subsets. The combined results of these experiments suggest that the outlined preparation method effectively protects MgCl 2 from atmospheric contamination compared to MgCl 2 samples that had no protective measures taken. Finally, the preparation method was utilized to protect a highly hygroscopic crystalline BaO thin film for characterization via scanning electron microscopy, thereby demonstrating a functional application of the outlined preparation technique and an additional use for the commercial cryo-EM transfer system beyond its intended application.

atmosphere-sensitive materials↗

Cu2ZnSnSe4 Photovoltaic Absorber Layers Evaluated by Transmission X-Ray Microscopy Tomography: Composition Fluctuations on the Length Scale of Grains

The origins of open-circuit voltage deficits in Cu2ZnSnS(e)4-based solar cells have been an intense topic of research over the past few years as device efficiencies have never approached those of CuInGaSe2 based cells despite the materials sharing similar crystal and electronic structures. In this work, we use transmission X-ray microscopy tomography to investigate the length scales over which elemental fluctuations occur. We find and show evidence of micron-scale Cu to Zn anti-correlations over a previously inaccessible combination of resolution and sample size that is consistent with the length scale of grains in this material. This result yields further insight into the causes of the large open-circuit voltage deficits regularly seen in these devices as well as the challenges of achieving compositional homogeneity in this material.

composition fluctuations↗

Transmission electron microscopy characterization of the fuel-cladding chemical interactions in HT9 cladded U-10Zr fuel

Fuel cladding chemical interaction (FCCI) is a key phenomenon needs to be better understood to establish the design basis for U-10Zr metallic fuel performance. Characterizing the microstructure and chemical composition of FCCI at micron and sub-micron scale is critically important toward a more mechanistic understanding of FCCI phenomenon and its potential effects on cladding integrity and metallic fuel performance. This paper, by using transmission electron microscopy, investigated the FCCI region in HT9 cladded U-10Zr fuel irradiated to 5.7% FIMA burnup at a peak inner cladding temperature of 615 °C in Fast Flux Test Facility (FFTF). Four distinct layers are identified in the FCCI region. The migration of Fe into the fuel side leads to the formation of several U-Zr-Fe ternary phases, including ?-Fe0.5Zr0.32U0.18, e-Fe0.3Zr0.4U0.3, and ?-Fe0.06Zr0.23U0.71, mingled with UFe2, U6Fe, and U phase at various Fe penetration depth up to ~ 150 µm. On the cladding side, grain coarsening and significant lanthanides infiltration along grain boundaries are observed. Laves phase, (Fe,Cr)2(Mo,W), which typically does not exist in fresh HT9, is identified in a wide radial range in the cladding. The typical HT9 martensitic lath structure and pre-existing M23C6 precipitates disappear, partially or completely, depending on the radial distance from the fuel-cladding interface. Those microstructural and compositional changes could cause mechanical degradation in the HT9 cladding. The present characterization results will improve the understanding of FCCI phenomenon and facilitate the development of microstructure-informed FCCI modeling for metallic fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Situ Heater Design for Nanoscale Synchrotron-Based Full-Field Transmission X-Ray Microscopy

Abstract The oxidation of nickel powder under a controlled gas and temperature environment was studied using synchrotron-based full-field transmission X-ray microscopy. The use of this technique allowed for the reaction to be imaged in situ at 55 nm resolution. The setup was designed to fit in the limited working distance of the microscope and to provide the gas and temperature environments analogous to solid oxide fuel cell operating conditions. Chemical conversion from nickel to nickel oxide was confirmed using X-ray absorption near-edge structure. Using an unreacted core model, the reaction rate as a function of temperature and activation energy were calculated. This method can be applied to study many other chemical reactions requiring similar environmental conditions.

in situ↗

Direct Investigation of Mg Intercalation into the Orthorhombic V 2 O 5 Cathode Using Atomic-Resolution Transmission Electron Microscopy [Direct Investigation of Mg intercalation into orthorhombic V 2 O 5 cathode using Atomic Resolution Electron Microscopy Methods]

Batteries based on Mg metal anode can promise much higher specific volumetric capacity and energy density compared to Li-ion systems and are, at the same time, safer and more cost-effective. While previous experimental reports have claimed reversible Mg intercalation into beyond Chevrel phase cathodes, they provide limited evidence of true Mg intercalation other than electrochemical data. Transmission electron microscopy techniques provide unique capabilities to directly image Mg intercalation and quantify the redox reaction within the cathode material. Here, we present a systematic study of Mg insertion into orthorhombic V 2 O 5 , combining aberration-corrected scanning transmission electron microscopy (STEM) imaging, electron energy-loss spectroscopy (EELS), and energy-dispersive X-ray spectroscopy (EDX) analysis. We compare the results from an electrochemically cycled V 2 O 5 cathode in a prospective full cell with Mg metal anode with a chemically synthesized MgV 2 O 5 sample. Results suggest that the electrochemically cycled orthorhombic V 2 O 5 cathode shows a local formation of the theoretically predicted ϵ-Mg 0.5 V 2 O 5 phase; however, the intercalation levels of Mg are lower than predicted. Lastly, this phase is different from the chemically synthesized sample, which is found to represent the δ-MgV 2 O 5 phase.

36 MATERIALS SCIENCE↗

Phase Transitions in Metal–Organic Frameworks Directly Monitored through In Situ Variable Temperature Liquid-Cell Transmission Electron Microscopy and In Situ X-ray Diffraction

Zr 6 -based metal–organic frameworks (MOFs) with tetratopic organic linkers have been extensively investigated owing to their versatile structural tunability. While diverse topologies and polymorphism in the resulting MOFs are often encountered with tetratopic linkers and Zr 6 nodes, reports on phase transitions within these systems are rare. Thus, we have a limited understanding of polymorph transformations, hindering the rational development of pure phase materials. In this study, a phase transition from a microporous MOF, scu-NU-906, to a mesoporous MOF, csq-NU-1008, was discovered and monitored through in situ variable temperature liquid-cell transmission electron microscopy (VT-LCTEM), high-resolution transmission electron microscopy (HRTEM), and in situ variable temperature powder X-ray diffraction (VT-PXRD). Furthermore, it was found that the microporous- to-mesoporous transformation in the presence of formic acid occurs via a concomitant dissolution–reprecipitation process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Local Electrostatic Effects with Scanning Probe Microscopy: Implications for Piezoresponse Force Microscopy and Triboelectricity

The implementation of contact mode Kelvin probe force microscopy (KPFM) utilizes the electrostatic interactions between tip and sample when the tip and sample are in contact with each other. Surprisingly, the electrostatic forces in contact are large enough to be measured even with tips as stiff as 4.5 N/m. As for traditional non-contact KPFM, the signal depends strongly on electrical properties of the sample, such as the dielectric constant, and the tip-properties, such as the stiffness. Since the tip is in contact with the sample, bias-induced changes in the junction potential between tip and sample can be measured with higher lateral and temporal resolution compared to traditional non-contact KPFM. Significant and reproducible variations of tip-surface capacitance are observed and attributed to surface electrochemical phenomena. Lastly, observations of significant surface charge states at zero bias and strong hysteretic electromechanical responses at non-ferroelectric surface have significant implications for fields such as triboelectricity and piezoresponse force microscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesizing new modes for subsurface atomic force microscopy

Non-destructive, nanoscale characterization techniques are needed to understand both synthetic and biological materials. The atomic force microscope uses a force-sensing cantilever with a sharp tip to measure the topography and other properties of surfaces. As the tip is scanned over the surface it experiences attractive and repulsive forces that depend on the chemical and mechanical properties of the sample. Here we show that an atomic force microscope can obtain a range of surface and subsurface information by making use of the nonlinear nanomechanical coupling between the probe and the sample. This technique, which is called mode-synthesizing atomic force microscopy, relies on multi-harmonic forcing of the sample and the probe. A rich spectrum of first- and higher-order couplings is discovered, providing a multitude of new operational modes for force microscopy, and the capabilities of the technique are demonstrated by examining nanofabricated samples and plant cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Piezoresponse force microscopy studies of PbTiO{sub 3} thin films grown via layer-by-layer gas phase reaction

We fabricated 20 nm thick PbTiO{sub 3} films via reactive magnetron sputtering and studied the domain switching phenomena and retention properties using piezoresponse force microscopy. We found that multistep deposited PbTiO{sub 3} thin films showed 29% smaller rms roughness (2.5 versus 3.5 nm), 28% smaller coercive voltage (1.68 versus 2.32 V), 100% higher d{sub 33} value, and improved retention characteristic (89% versus 52% of remained poled domain area in 1280 min after poling) than single-step deposited PbTiO{sub 3} thin films. We attribute the improvement to the more complete chemical reaction between PbO and TiO{sub 2} during the film growth.

36 MATERIALS SCIENCE↗

An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor accommodates many gas atmospheres, including reactive or corrosive gasses, but was designed specically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconguration. Using the reactor contributes over 85% less additional absorption compared to lling the STXM chamber with process gas, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

Environmental Molecular Sciences Laboratory↗

Defects in paramagnetic Co-doped ZnO films studied by transmission electron microscopy

We study planar defects in epitaxial Co:ZnO dilute magnetic semiconductor thin films deposited on c-plane sapphire (Al{sub 2}O{sub 3}), as well as the Co:ZnO/Al{sub 2}O{sub 3} interface, using aberration-corrected transmission electron microscopy and electron energy-loss spectroscopy. Co:ZnO samples that were deposited using pulsed laser deposition and reactive magnetron sputtering are both found to contain extrinsic stacking faults, incoherent interface structures, and compositional variations within the first 3–4 Co:ZnO layers next to the Al{sub 2}O{sub 3} substrate. The stacking fault density is in the range of 10{sup 17} cm{sup −3}. We also measure the local lattice distortions around the stacking faults. It is shown that despite the relatively high density of planar defects, lattice distortions, and small compositional variation, the Co:ZnO films retain paramagnetic properties.

36 MATERIALS SCIENCE↗

Combining low-energy electron microscopy and scanning probe microscopy techniques for surface science: Development of a novel sample-holder

We introduce an experimental facility dedicated to surface science that combines Low-Energy Electron Microscopy/Photo-Electron Emission Microscopy (LEEM/PEEM) and variable-temperature Scanning Probe Microscopy techniques. A technical challenge has been to design a sample-holder that allows to exploit the complementary specifications of both microscopes and to preserve their optimal functionality. Experimental demonstration is reported by characterizing under ultrahigh vacuum with both techniques: Au(111) surface reconstruction and a two-layer thick graphene on 6H-SiC(0001). A set of macros to analyze LEEM/PEEM data extends the capabilities of the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross Kelvin force microscopy and conductive atomic force microscopy studies of organic bulk heterojunction blends for local morphology and electrical behavior analysis

Bulk Heterojunction (BHJ) organic photovoltaic devices performances depend on the relative organization and physical properties of the electron-donor and -acceptor materials. In this paper, BHJs of poly(3-hexyl-thiophene) (P3HT) associated with an electron acceptor material, 1-(3-methoxycarbonyl)-propyl-1-phenyl[6,6]C6 (PCBM) or [Ni(4dodpedt){sub 2}], are studied in terms of morphology, ordering, and electrical properties. First, comparison between the two BHJs performed by Atomic Force Microscopy (AFM) and Raman characterizations shows that P3HT structuration is improved by blending with [Ni(4dodpedt){sub 2}]. Then, the relationship between charges trapping, electrical properties, and film morphology is investigated using conductive AFM and Kelvin Force Microscopy. Measurements in dark condition and under solar cell simulator provide complementary information on electrical phenomena in these organic nanostructures. Finally, time dependent measurement highlights the influence of charges stacking on conduction. Specifically, we demonstrate that charge accumulation initiated by illumination remains valid after switching off the light, and induces the modification in current versus voltage characteristic of P3HT: PCBM blend. Finally, we observe a current increasing which can be attributed to the energy barrier decreasing due to charges trapping in PCBM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Band Excitation Kelvin probe force microscopy utilizing photothermal excitation

A multifrequency open loop Kelvin probe force microscopy (KPFM) approach utilizing photothermal as opposed to electrical excitation is developed. Photothermal band excitation (PthBE)-KPFM is implemented here in a grid mode on a model test sample comprising a metal-insulator junction with local charge-patterned regions. Unlike the previously described open loop BE-KPFM, which relies on capacitive actuation of the cantilever, photothermal actuation is shown to be highly sensitive to the electrostatic force gradient even at biases close to the contact potential difference (CPD). PthBE-KPFM is further shown to provide a more localized measurement of true CPD in comparison to the gold standard ambient KPFM approach, amplitude modulated KPFM. In conclusion, PthBE-KPFM data contain information relating to local dielectric properties and electronic dissipation between tip and sample unattainable using conventional single frequency KPFM approaches.

36 MATERIALS SCIENCE↗