3D Printing of Transparent Silicone Elastomers

Here in this paper, inks for transparent elastomers that are formulated by matching the refractive index of silica and polysiloxanes are described. The transparent inks transmit up to ≈90% of 700 nm light through 1 cm and remain transparent when solidified. The inks and solidified materials exhibit a thermochromic effect. This thermochromic effect can be controlled by the refractive index mismatch. Transparency may increase or decrease as temperature increases, depending on the refractive index mismatch of the base polysiloxane and silica. It is found that the rheological properties of the ink depend on the distribution of silica particles, which is dictated by silica functionality, weight content, and processing. Siloxane precursors that vary in chemical functionality are introduced to tailor the mechanical properties of the printed elastomers, which obtain stretchability >65% along with a tensile modulus of 1.9 MPa. After optimizing siloxane chemistry and ink processing, the authors are able to print transparent elastomers. Potential applications are demonstrated for printed structures by printing encapsulation structures for light-emitting diodes, semitransparent dye-filled structures, a microfluidic mixing device, and a multimaterial structure that exhibits temperature-dependent camouflage.

36 MATERIALS SCIENCE↗

Self-generated electrokinetic flows from active-charged boundary patterns

We develop a hydrodynamic description of self-generated electrolyte flow in capillaries whose bounding walls feature nonuniform distributions of charge nonuniform active ionic fluxes. The hydrodynamic velocity arising in such a system has components that are forbidden by symmetry in the absence of charge and fluxes. However, when these two boundary mechanisms are simultaneously present, they can lead to a symmetry broken state where steady flows with both unidirectional and circulatory components emerge. We show that these flow states arise when modulated boundary patterns of charge and fluxes are offset by a flux-charge phase difference, which is associated with the separation between sites of their peak densities on the wall. Mismatch in diffusivity of cationic and anionic species can modify the flow states and becomes an enhancing factor when fluxes of both ion species are being produced together at the same site. We demonstrate that this mechanism can be realized with a microfluidic generator that is powered by enzyme-coated patches that catalyze reactants in the solution to produce fluxes of ions. The local ionic elevation or depletion, which disrupts a nonuniform double layer, promotes self-induced gradients yielding persistent body forces to generate bulk fluid motion. Our work quantifies a boundary-driven mechanism behind self-sustained electrolyte flow in confined environments that exists without any external bulk-imposed fields or gradients. It provides a theoretical framework for understanding the combined effect of active and charged boundaries that are relevant in biological or soft matter systems, and can be utilized in electrofluidic and iontronic applications.

active matter↗

Helfrich-Hurault elastic instabilities driven by geometrical frustration

Here, the Helfrich-Hurault (HH) elastic instability is a well-known mechanism behind patterns that form as a result of strain upon liquid crystal systems with periodic ground states. In the HH model, layered structures undulate and buckle in response to local, geometric incompatibilities in order to maintain the preferred layer spacing. Classic HH systems include cholesteric liquid crystals under electromagnetic field distortions and smectic liquid crystals under mechanical strains, where both materials are confined between rigid substrates. However, richer phenomena are observed when undulation instabilities occur in the presence of deformable interfaces and variable boundary conditions. Understanding how the HH instability is affected by deformable surfaces is imperative for applying the instability to a broader range of materials. In this review, the HH mechanism is reexamined and special focus is given to how the boundary conditions influence the response of lamellar systems to geometrical frustration. Lamellar liquid crystals confined within a spherical shell geometry are used as the model system. Made possible by the relatively recent advances in microfluidics within the past 15 years, liquid crystal shells are composed entirely of fluid interfaces and have boundary conditions that can be dynamically controlled at will. Past and recent work that exemplifies how topological constraints, molecular anchoring conditions, and boundary curvature can trigger the HH mechanism in liquid crystals with periodic ground states is examined. The review ends by identifying similar phenomena across a wide variety of materials, both biological and synthetic. The fact that the HH mechanism is a generic and often overlooked response of periodic materials to geometrical frustration is highlighted.

42 ENGINEERING↗

Fabricated devices for performing bacterial-fungal interaction experiments across scales

Diverse and complex microbiomes are found in virtually every environment on Earth. Bacteria and fungi often co-dominate environmental microbiomes, and there is growing recognition that bacterial-fungal interactions (BFI) have significant impacts on the functioning of their associated microbiomes, environments, and hosts. Investigating BFI in vitro remains a challenge, particularly when attempting to examine interactions at multiple scales of system complexity. Fabricated devices can provide control over both biotic composition and abiotic factors within an experiment to enable the characterization of diverse BFI phenotypes such as modulation of growth rate, production of biomolecules, and alterations to physical movements. Engineered devices ranging from microfluidic chips to simulated rhizosphere systems have been and will continue to be invaluable to BFI research, and it is anticipated that such devices will continue to be developed for diverse applications in the field. This will allow researchers to address specific questions regarding the nature of BFI and how they impact larger microbiome and environmental processes such as biogeochemical cycles, plant productivity, and overall ecosystem resilience. Devices that are currently used for experimental investigations of bacteria, fungi, and BFI are discussed herein along with some of the associated challenges and several recommendations for future device design and applications.

59 BASIC BIOLOGICAL SCIENCES↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO 2 Foam Transport in Fractured Unconventional Reservoirs

Pressure limitations of many microfluidic platforms have been a significant challenge in microfluidic experimental studies of fractured media. As a result, these platforms have not been fully exploited for direct observation of high-pressure transport in fractures. This work introduces microfluidic platforms that enable direct observation of multiphase flow in devices featuring surrogate permeable media and fractured systems. Such platforms provide a pathway to address important and timely questions such as those related to CO 2 capture, utilization and storage. This work provides a detailed description of the fabrication techniques and an experimental setup that may serve to analyze the behavior of supercritical CO 2 (scCO 2 ) foam, its structure and stability. Such studies provide important insights regarding enhanced oil recovery processes and the role of hydraulic fractures in resource recovery from unconventional reservoirs. This work presents a comparative study of microfluidic devices developed using two different techniques: photolithography/wet-etching/ thermal-bonding versus Selective Laser-induced Etching. Both techniques result in devices that are chemically and physically resistant and tolerant of high pressure and temperature conditions that correspond to subsurface systems of interest. Both techniques provide pathways to high-precision etched microchannels and capable lab-on-chip devices. Photolithography/wet-etching, however, enables fabrication of complex channel networks with complex geometries, which would be a challenging task for laser etching techniques. This work summarizes a step-by-step photolithography, wet-etching and glass thermal-bonding protocol and, presents representative observations of foam transport with relevance to oil recovery from unconventional tight and shale formations. In conclusion, this work describes the use of a high resolution monochromatic sensor to observe scCO 2 foam behavior where the entirety of the permeable medium is observed simultaneously while preserving the resolution needed to resolve features as small as 10 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Imaging of Microbial Interactions With Tree Roots Using a Microfluidics Setup

Coupling microfluidics with microscopy has emerged as a powerful approach to study at cellular resolution the dynamics in plant physiology and root-microbe interactions (RMIs). Most devices have been designed to study the model plant Arabidopsis thaliana at higher throughput than conventional methods. However, there is a need for microfluidic devices which enable in vivo studies of root development and RMIs in woody plants. Here, we developed the RMI-chip, a simple microfluidic setup in which Populus tremuloides (aspen tree) seedlings can grow for over a month, allowing continuous microscopic observation of interactions between live roots and rhizobacteria. We find that the colonization of growing aspen roots by Pseudomonas fluorescens in the RMI-chip involves dynamic biofilm formation and dispersal, in keeping with previous observations in a different experimental set-up. Also, we find that whole-cell biosensors based on the rhizobacterium Bacillus subtilis can be used to monitor compositional changes in the rhizosphere but that the application of these biosensors is limited by their efficiency at colonizing aspen roots and persisting. These results indicate that functional imaging of dynamic root-bacteria interactions in the RMI-chip requires careful matching between the host plant and the bacterial root colonizer.

59 BASIC BIOLOGICAL SCIENCES↗

Transport Modeling of Kinetically Limited Microscale Extraction Systems: Droplet and Supported Liquid Membrane Separations

Microfluidic droplet extraction devices can be used to efficiently measure solute phase transfer kinetics in liquid–liquid extraction systems. In this work, a droplet extraction apparatus was constructed using off-the-shelf and custom 3D printed parts for less than 110 USD. The interfacial kinetics of the transfer of Pu(IV) between an aqueous nitric acid phase and a 5 v/v% tridodecylamine (TDA) in toluene phase were characterized by determining the extent of Pu(IV) transfer between phases at different flow rates. Forward interfacial rate constants calculated from this data using an analytical model are 5.6 × 10 –3 mm s –1 under extraction (aqueous-to-organic solute transfer) conditions and 3.3 × 10 –3 mm s –1 under stripping (organic-to-aqueous solute transfer) conditions. The analytical model is valid when the rate of solute transfer across the interface between the two liquid phases has pseudo-first-order reversible reaction kinetics and is slow relative to the rate of solute transport to the interface. The change in the outlet concentration with residence time determined using the analytical model was compared with the results of a numerical model accounting for advection/diffusion to the interface in addition to kinetically limited interfacial solute transfer. These calculations revealed that for systems with forward interfacial rate constants greater than approximately 10 –2 mm s –1 , the analytical model must be supplemented with a numerical transport model accounting for an additional advection/diffusion mass transfer resistance. This threshold corresponds to a Damköhler number of one. The measured interfacial kinetic rate constants for Pu(IV)/TDA were used in a supported liquid membrane (SLM) numerical model, which showed that the Pu(IV) phase transfer kinetics are fast enough for use in a practical separation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

Scalable Gas Diffusion Electrode Fabrication for Electrochemical CO 2 Reduction Using Physical Vapor Deposition Methods

Electrochemical CO 2 reduction (ECR) promises the replacement of fossil fuels as the source of feedstock chemicals and seasonal storage of renewable energy. While much progress has been made in catalyst development and electrochemical reactor design, few studies have addressed the effect of catalyst integration on device performance. Using a microfluidic gas diffusion electrolyzer, we systematically studied the effect of thickness and the morphology of electron beam (EB) and magnetron-sputtered (MS) Cu catalyst coatings on ECR performance. We observed that EB-Cu outperforms MS-Cu in current density, selectivity, and energy efficiency, with 400 nm thick catalyst coatings performing the best. Additionally, the superior performance of EB-Cu catalysts is assigned to their faceted surface morphology and sharper Cu/gas diffusion layer interface, which increases their hydrophobicity. Tests in a large-scale zero-gap electrolyzer yielded similar product selectivity distributions with an ethylene Faradaic efficiency of 39% at 200 mA/cm 2 , demonstrating the scalability for industrial ECR applications.

36 MATERIALS SCIENCE↗

Perspectives on Microfluidics for the Study of Asphaltenes in Upstream Hydrocarbon Production: A Minireview

The utilization of microfluidics has generated deep insights into asphaltene precipitation mechanisms and oil–water emulsion stabilization. Agglomeration and precipitation of asphaltenes can cause flow assurance problems during the extraction and transportation of crude oil. Change in temperature, pressure, reservoir conditions, and solvents can change the local environment, leading to asphaltene precipitation. Understanding asphaltene properties and precipitation pathways becomes critical in devising mitigation methods, demulsifiers, and suitable conditions during hydrocarbon processing. Microfluidics has helped in high throughput measurement studies, understanding critical processing conditions, fast demulsifier screening, and the effect of solvent concentration on deposition, generating useful information for utilization at the point of resource extraction facilitating improved resource management. It has become possible to capture the porous, complex nature of reservoir formations and the interaction of chemicals during precipitation through integrated analytics and visualization studies available only through microfluidics. The use of droplet microfluidics, with optical microscopy and high-speed imaging to study the oil–water interface, has resulted in greater understanding of the role of asphaltenes in interfacial properties and emulsion stabilization. Here, this minireview highlights the crucial aspects of microfluidics that have been used to understand physicochemical behavior and dynamics of asphaltene deposition. Some of the unique devices have been presented focusing on the key elements of microfluidics design, fabrication, and analysis, as the insight obtained from microfluidics strongly depends on the device design and the controllability of the experimental parameters. Successful implementation of microfluidics for efficient and controlled experiments, short analysis time scales and rapid screening, and generation of high-quality, reliable data that convey asphaltene deposition issues and interface behavior in emulsions shows the importance of microsystems for advancing knowledge in hydrocarbon production and processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

All polymer microfluidic chips—A fixed target sample delivery workhorse for serial crystallography

The development of x-ray free electron laser (XFEL) light sources and serial crystallography methodologies has led to a revolution in protein crystallography, enabling the determination of previously unobtainable protein structures and near-atomic resolution of otherwise poorly diffracting protein crystals. However, to utilize XFEL sources efficiently demands the continuous, rapid delivery of a large number of difficult-to-handle microcrystals to the x-ray beam. A recently developed fixed-target system, in which crystals of interest are enclosed within a sample holder, which is rastered through the x-ray beam, is discussed in detail in this Perspective. The fixed target is easy to use, maintains sample hydration, and can be readily modified to allow a broad range of sample types and different beamline requirements. Recent innovations demonstrate the potential of such microfluidic-based fixed targets to be an all-around “workhorse” for serial crystallography measurements. In conclusion, this Perspective will summarize recent advancements in microfluidic fixed targets for serial crystallography, examine needs for future development, and guide users in designing, choosing, and utilizing a fixed-target sample delivery device for their system.

59 BASIC BIOLOGICAL SCIENCES↗

Wireless optofluidic systems for programmable in vivo pharmacology and optogenetics

Provided are implantable, injectable and/or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate, one or more microfluidic channels embedded in or supported by the substrate and a fluid actuator in operational communication with one or more reservoirs and responsive to a wireless control signal. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In some embodiments, the devices are self-powered and fully implantable. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

Rogers, John A.↗

Vortex fluidic regulated phospholipid equilibria involving liposomes down to sub-micelle size assemblies

Conventional channel-based microfluidic platforms have gained prominence in controlling the bottom-up formation of phospholipid based nanostructures including liposomes. However, there are challenges in the production of liposomes from rapidly scalable processes. These have been overcome using a vortex fluidic device (VFD), which is a thin film microfluidic platform rather than channel-based, affording ~110 nm diameter liposomes. The high yielding and high throughput continuous flow process has a 45° tilted rapidly rotating glass tube with an inner hydrophobic surface. Processing is also possible in the confined mode of operation which is effective for labelling pre-VFD-prepared liposomes with fluorophore tags for subsequent mechanistic studies on the fate of liposomes under shear stress in the VFD. In situ small-angle neutron scattering (SANS) established the co-existence of liposomes ~110 nm with small rafts, micelles, distorted micelles, or sub-micelle size assemblies of phospholipid, for increasing rotation speeds. The equilibria between these smaller entities and ~110 nm liposomes for a specific rotational speed of the tube is consistent with the spatial arrangement and dimensionality of topological fluid flow regimes in the VFD. The prevalence for the formation of ~110 nm diameter liposomes establishes that this is typically the most stable structure from the bottom-up self-assembly of the phospholipid and is in accord with dimensions of exosomes.

60 APPLIED LIFE SCIENCES↗

Computational study of inertial migration of prolate particles in a straight rectangular channel

Inertial migration of spherical particles has been investigated extensively using experiments, theory, and computational modeling. Yet, a systematic investigation of the effect of particle shape on inertial migration is still lacking. Herein, we numerically mapped the migration dynamics of a prolate particle in a straight rectangular microchannel using smoothed particle hydrodynamics at moderate Reynolds number flows. After validation, we applied our model to 2:1 and 3:1 shape aspect ratio particles at multiple confinement ratios. Their effects on the final focusing position, rotational behavior, and transitional dynamics were studied. In addition to the commonly reported tumbling motion, for the first time, we identified a new logrolling behavior of a prolate ellipsoidal particle in the confined channel. This new behavior occurs when the confinement ratio is above an approximate threshold value of K = 0.72. Our microfluidic experiments using cell aggregates with similar shape aspect ratio and confinement ratio confirmed this new predicted logrolling motion. In this study, we also found that the same particle can undergo different rotational modes, including kayaking behavior, depending on its initial cross-sectional position and orientation. Furthermore, we examined the migration speed, angular velocity, and rotation period as well as their dependence on both particle shape aspect ratio and confinement ratio. Our findings are especially relevant to the applications where particle shape and alignment are used for sorting and analysis, such as the use of barcoded particles for biochemical assays through optical reading, or the shape-based enrichment of microalgae, bacteria, and chromosomes.

42 ENGINEERING↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic liquid sheets as large-area targets for high repetition XFELs

The high intensity of X-ray free electron lasers (XFELs) can damage solution-phase samples on every scale, ranging from the molecular or electronic structure of a sample to the macroscopic structure of a liquid microjet. By using a large surface area liquid sheet microjet as a sample target instead of a standard cylindrical microjet, the incident X-ray spot size can be increased such that the incident intensity falls below the damage threshold. This capability is becoming particularly important for high repetition rate XFELs, where destroying a target with each pulse would require prohibitively large volumes of sample. We present here a study of microfluidic liquid sheet dimensions as a function of liquid flow rate. Sheet lengths, widths and thickness gradients are shown for three styles of nozzles fabricated from isotropically etched glass. In-vacuum operation and sample recirculation using these nozzles is demonstrated. The effects of intense XFEL pulses on the structure of a liquid sheet are also briefly examined.