Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Terahertz-Regime, Micro-VEDs: Evaluation of Micromachined TWT Conceptual Designs

Summary form only given. The Terahertz (THz) region of the electromagnetic spectrum (approx.300-3000 GHz) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.01-10.0 W continuous wave), efficient (>1 %), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and relatively inexpensive. Micro-machined Vacuum Electron Devices (micro-VEDs) represent a promising solution. We describe prospects for miniature, THz-regime TWTs fabricated using micromachining techniques. Several approx.600 GHz conceptual designs are compared. Their expected performance has been analyzed using SD, 2.51), and 3D TWT codes. A folded waveguide (FWG) TWT forward-wave amplifier design is presented based on a Northrop Grumman (NGC) optimized design procedure. This conceptual device is compared to the simulated performance of a novel, micro-VED helix TWT. Conceptual FWG TWT backward-wave amplifiers and oscillators are also discussed. A scaled (100 GHz) FWG TWT operating at a relatively low voltage (-12 kV) is under development at NGC. Also, actual-size micromachining experiments are planned to evaluate the feasibility of arrays of micro-VED TWTs. Progress and results of these efforts are described. This work was supported, in part by AFOSR, ONR, and NSF.

Booske, John H.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Spacecraft Micro-Vibration: A Survey of Problems, Experiences, Potential Solutions, and Some Lessons Learned

Predicting, managing, controlling, and testing spacecraft microvibrations due to on-board internal disturbance sources is a formidable multi-disciplinary systems engineering challenge, especially for those observatories hosting extremely sensitive optical sensor payloads with stringent requirements on allowable line-of-sight jitter. In this paper some specific spacecraft micro-vibration engineering challenges will be introduced and described. Technical background context is provided with the inclusion of several illustrative examples of NASA and European Space Agency missions (both past and present) where dynamic interactions have to be addressed and which have demanding payload instrument line-of-sight jitter requirements. A general modeling, analysis, simulation, and test approach to address and solve the overall problem of spacecraft micro-vibrations is outlined. Recommended rules of thumb are presented to provide guidance for analysts on where to initiate and how to approach a new spacecraft micro-vibration design problem. A set of experience-based spacecraft micro-vibration lessons learned are also presented in the hope they can be leveraged on new system development projects to help overcome unfamiliarity with previously identified microvibration technical pitfalls and challenges.

Dennehy, Cornelius↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

J. S. Adams↗

Predictive Modeling of Carbon Ablators Using Micro and Macro-Scale Modeling

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

Application of Micro-thrusters for Space Observatory Precision Attitude Control

This paper describes the results of a NASA investigation into the benefits of micro-thrusters compared to reaction wheels on future observatory-class missions with tight pointing stability requirements. Pointing repeatability and stability (i.e., jitter) requirements are key for space telescope missions of the future. For example, managing jitter is essential to being able to “image” planets orbiting distant stars. Jitter requirements for missions in this class are difficult to meet with current reaction wheel-based architectures. The reaction wheels are typically the largest pointing disturbance on the spacecraft. Disturbances from reaction wheels can be mitigated, typically by mechanically isolating the wheels, which imposes system complexity and cost. Thrusters capable of thrust forces in the micronewton (μN) range (referred to as micro-thrusters or micronewton thrusters) have been developed to support the Laser Interferometer Space Antenna (LISA) mission, which requires drag-free control to place a test mass in near-perfect free-fall Beyond the drag-free control application, micro-thrusters could be used as a substitute for reaction wheels or as a supplement to wheels for fine pointing control. Used in this fashion, micro-thrusters have potential for reducing the cost and technical risks of achieving demanding pointing stability performance on observatory-class missions.

Chiang, Richard Y.↗

A Preliminary Study on the Feasibility of Large Language Models for Detecting Micro-Behaviors Among Team Members in Space Missions

Large-language models (LLMs) have been recently used for spoken language understanding (SLU) to infer meaning and semantics from speech in tasks such as speaker intent and sentiment classification. Due to being trained on large amounts of data, and their ability to understand context and relationships between words, LLMs are competent, enabling them to generalize across tasks without requiring many task-specific training samples. This research examines the feasibility of few-shot learning in LLMs for detecting subtle, brief, and possibly unconscious interactions between team members, called ``micro-behaviors," and provides insights into the appropriate design of LLMs for this task. Our data came from 5 teams participating in a 45-day mission at the US National Aeronautics and Space Administration’s (NASA) Human Exploration Research Analog (HERA). More specifically we used data collected from team interaction battery (TIB) tasks teams performed five times in-mission which comprise an average 1.5 hours of conversation data per day. Micro-behaviors were coded according to an adapted version of Smith & Griffins (2022) theoretical framework in terms of Violation (i.e., presence of valenced behavior, uplifting/positive or discouraging/negative), Intensity (i.e., force of behavior in terms of how uplifting or discouraging is the behavior), and Intent (i.e., motive of the behavior in terms of whether it was deliberate or unintentional). We explore the ability of LLMs to detect the presence and intensity of micro-behaviors. We examine employing and fine-tuning readily available LLMs (i.e., RoBERTa, DistilBERT), as well as prompting state-of-the-art sequence classification models (i.e., Llama-2, Llama-3). In a total of 13,058 conversational turns (17.8% uplifting, 3.3% discouraging, 75.76% neutral, 3.14% nulls), we compute the macro F1-score of the 3-way micro-behavior classification task (i.e., classifying among uplifting, discouraging, and neutral; 33% chance). Results indicate that the RoBERTa model achieves a F1-score of 36.2% (uplift: 43.3% precision (P), 15.1% recall (R); discourage: 20% P, 0.5% R). These results significantly improve when we augment the data via paraphrasing in the RoBERTa model, reaching a 41.2% macro F1-score (uplift: 37.7% P, 86.3% R; discourage: 3.5% P, 1.8% R). Finally, the Llama-2 model with 3-shot prompting yields 38% macro F1-score (uplift: 28.7% P, 20% R; discourage: 7.2% P, 18% R), which is slightly better compared to the RoBERTa model without data augmentation, highlighting the effectiveness of sequence classification models in detecting minority classes with a small sample size. Findings indicate that LLMs hold potential to detect subtle behaviors in conversations, which could be valuable in assessing team behavior in space exploration missions. Future studies will evaluate the performance of different LLM prompting strategies or fine-tuning methods.

Ankush Raut↗

Fully Self-Contained Vision-Aided Navigation and Landing of a Micro Air Vehicle Independent from External Sensor Inputs

Direct-lift micro air vehicles have important applications in reconnaissance. In order to conduct persistent surveillance in urban environments, it is essential that these systems can perform autonomous landing maneuvers on elevated surfaces that provide high vantage points without the help of any external sensor and with a fully contained on-board software solution. In this paper, we present a micro air vehicle that uses vision feedback from a single down looking camera to navigate autonomously and detect an elevated landing platform as a surrogate for a roof top. Our method requires no special preparation (labels or markers) of the landing location. Rather, leveraging the planar character of urban structure, the landing platform detection system uses a planar homography decomposition to detect landing targets and produce approach waypoints for autonomous landing. The vehicle control algorithm uses a Kalman filter based approach for pose estimation to fuse visual SLAM (PTAM) position estimates with IMU data to correct for high latency SLAM inputs and to increase the position estimate update rate in order to improve control stability. Scale recovery is achieved using inputs from a sonar altimeter. In experimental runs, we demonstrate a real-time implementation running on-board a micro aerial vehicle that is fully self-contained and independent from any external sensor information. With this method, the vehicle is able to search autonomously for a landing location and perform precision landing maneuvers on the detected targets.

autonomous landing↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Integrating Micro-computers with a Centralized DBMS: ORACLE, SEED AND INGRES

Users of ADABAS, a relational-like data base management system (ADABAS) with its data base programming language (NATURAL) are acquiring microcomputers with hopes of solving their individual word processing, office automation, decision support, and simple data processing problems. As processor speeds, memory sizes, and disk storage capacities increase, individual departments begin to maintain "their own" data base on "their own" micro-computer. This situation can adversely affect several of the primary goals set for implementing a centralized DBMS. In order to avoid this potential problem, these micro-computers must be integrated with the centralized DBMS. An easy to use and flexible means for transferring logic data base files between the central data base machine and micro-computers must be provided. Some of the problems encounted in an effort to accomplish this integration and possible solutions are discussed.

Hoerger, J.↗

United States Air Force Academy's micro-gravity research using G-0307

The purpose of this discussion is to report on the current materials research being done in micro-gravity solidification and future experimentation planned on-board a space shuttle mission. The Department of Engineering Mechanics at the USAF Academy is developing a micro-gravity furnace to be used on board the space shuttle. The micro-g furnace will be used to conduct materials research dealing with such topics as immiscible alloy solidification. The purpose behind this research project is three-fold: first, to develop a simple, inexpensive, an easy to use furnace to conduct space materials research; second, to conduct a solidification experiment on a lead-zinc alloy in space that macrosegregates due to gravity: and third, to provide a research mechanism for students to get involved with space materials research.

Glon D Turner↗

Micro Channel/Multibus-II Interface Circuit

Micro Channel/Multibus-II interface circuit provides electrical interconnections enabling communications between Micro Channels of IBM Personal System/2 computers and IEEE 1296 standard Multibus-II parallel system bus (iPSB). Made mostly of commercially available parts, interface enables independent Micro Channels to communicate over iPSB without modification.

D'Ambrose, John J.↗

A macro-micro robot for precise force applications

This paper describes an 8 degree-of-freedom macro-micro robot capable of performing tasks which require accurate force control. Applications such as polishing, finishing, grinding, deburring, and cleaning are a few examples of tasks which need this capability. Currently these tasks are either performed manually or with dedicated machinery because of the lack of a flexible and cost effective tool, such as a programmable force-controlled robot. The basic design and control of the macro-micro robot is described in this paper. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system.

Marzwell, Neville I.↗

The NT digital micro tape recorder

The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of intensive, multi-disciplinary research and development. What follows is a discussion of the technologies that have made the NT possible: (1) NT format mechanics, (2) NT media, (3) NT circuitry and board.

Sasaki, Toshikazu↗

Micro-apparatus for rapid determinations of protein solubilities

We have developed a column-based micro-technique for rapid determinations of protein solubilities. While retaining a large crystal surface area, the column dead volume has been reduced to equal to or less than 5 micro liters. The technique was tested with tetragonal lysozyme (pH 4.5, 0.1 M acetate, 3.0 percent NaCl, 5-25 C) and column volumes of about 60, 300, and 900 micro liters. Identical solubility data were obtained, indicating that equilibration was obtained even in the smallest columns. In addition, solubility data for Br- and I- salts of lysozyme (pH 4.5, 0.1 M acetate buffer, 0.5 M salt concentrations) were obtained. It appears that the technique can be further miniaturized. The limit in further reducing the crystalline column volume is determined by the minimum solution sample size needed to determine the protein concentration.

Pusey, Marc L.↗

Micro-optics technology and sensor systems applications

The current generation of electro-optical sensors utilizing refractive and reflective optical elements require sophisticated, complex, and expensive designs. Advanced-technology-based electro-optical sensors of minimum size and weight require miniaturization of optical, electrical, and mechanical devices with an increasing trend toward integration of various components. Micro-optics technology has the potential in a number of areas to simplify optical design with improved performance. This includes internally cooled apertures, hybrid optical design, microlenses, dispersive multicolor microlenses, active dither, electronically controlled optical beam steer, and microscopic integration of micro-optics, detectors, and signal processing layers. This paper describes our approach to the development of micro-optics technology with our main emphasis for sensors applications.

Gal, George↗

Conceptual design of a device to measure hand swelling in a micro-gravity environment

In the design of pressurized suits for use by astronauts in space, proper fit is an important consideration. One particularly difficult aspect of the suit design is the design of the gloves. If the gloves of the suit do not fit properly, the grip strength of the astronaut can be decreased by as much as fifty percent. These gloves are designed using an iterative process and can cost over 1.5 million dollars. Glove design is further complicated by the way the body behaves in a micro-gravity environment. In a micro-gravity setting, fluid from the lower body tends to move into the upper body. Some of this fluid collects in the hands and causes the hands to swell. Therefore, a pair of gloves that fit well on earth may not fit well when they are used in space. The conceptual design process for a device which can measure the swelling that occurs in the hands in a micro-gravity environment is described. This process involves developing a specifications list and function structure for the device and generating solution variants for each of the sub functions. The solution variants are then filtered, with the variants that violate any of the specifications being discarded. After acceptable solution variants are obtained, they are combined to form design concepts. These design concepts are evaluated against a set of criteria and the design concepts are ranked in order of preference. Through this process, the two most plausible design concepts were an ultrasonic imaging technique and a laser mapping technique. Both of these methods create a three dimensional model of the hand, from which the amount of swelling can be determined. In order to determine which of the two solutions will actually work best, a further analysis will need to be performed.

Hysinger, Christopher L.↗