Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Illustration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

103 records · Page 6

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗

Blended Training for Combat Medics

Bleeding from extremity wounds is the number one cause of preventable death on the battlefield and current research stresses the importance of training in preparing every Soldier to use tourniquets. HapMed is designed to provide tourniquet application training to combat medics and Soldiers using a blended training solution encompassing information, demonstration, practice, and feedback. The system combines an instrumented manikin arm, PDA, and computer. The manikin arm provides several training options including stand-alone, hands-on skills training in which soldiers can experience the actual torque required to staunch bleeding from an extremity wound and be timed on tourniquet application. This is more realistic than using a block of wood to act as a limb, which is often how training is conducted today. Combining the manikin arm with the PDA allows instructors to provide scenario based training. In a classroom or field setting, an instructor can specify wound variables such as location, casualty size, and whether the wound is a tough bleed. The PDA also allows more detailed feedback to be provided. Finally, combining the manikin arm with game-based technologies, the third component, provides opportunities to build knowledge and to practice battlefield decision making. Not only do soldiers learn how to apply a tourniquet, but when to apply a tourniquet in combat. The purpose of the paper is to describe the learning science underlying the design of HapMed, illustrate the training system and ways it is being expanded to encompass other critical life-saving tasks, and report on feedback received from instructors and trainees at military training and simulation centers.

Fowlkes, Jennifer↗

Changing temperature profiles and the risk of dengue outbreaks

As temperatures change worldwide, the pattern and competency of disease vectors will change, altering the global distribution of both the burden of infectious disease and the risk of the emergence of those diseases into new regions. To evaluate the risk of potential summer dengue outbreaks triggered by infected travelers under various climate scenarios, we develop an SEIR-type model, run numerical simulations, and conduct sensitivity analyses under a range of temperature profiles. Our model extends existing theoretical frameworks for studying dengue dynamics by introducing temperature dependence of two key parameters: the mosquito extrinsic incubation period and the lifespan of mosquitoes, which empirical data suggests are both highly temperature dependent. We find that changing temperature significantly alters dengue risk in an inverted U-shape, with temperatures in the range 27-31°C producing the highest risk. As temperatures increase beyond 31°C, the determinants of dengue risk begin to shift from mosquito biting rate and carrying capacity to the duration of the human infectious period, suggesting that changing temperatures not only alter dengue risk but also the potential efficacy of control measures. To illustrate the role of spatial and temporal temperature heterogeneity, we select five US cities where the primary dengue vector, the mosquito Aedes aegypti , has been observed, and which have had dengue cases in the past: Los Angeles, Houston, Miami, Brownsville, and Phoenix. Our analysis suggests that an increase of 3°C leads to an approximate doubling of the risk of dengue in Los Angeles and Houston, but a reduction of risk in Miami, Brownsville, and Phoenix due to extreme heat.

54 ENVIRONMENTAL SCIENCES↗

From pools to flow: The PROMISE framework for new insights on soil carbon cycling in a changing world

Soils represent the largest terrestrial reservoir of organic carbon, and the balance between soil organic carbon (SOC) formation and loss will drive powerful carbon-climate feedbacks over the coming century. To date, efforts to predict SOC dynamics have rested on pool-based models, which assume classes of SOC with internally homogenous physicochemical properties. However, emerging evidence suggests that soil carbon turnover is not dominantly controlled by the chemistry of carbon inputs, but rather by restrictions on microbial access to organic matter in the spatially heterogeneous soil environment. The dynamic processes that control the physicochemical protection of carbon translate poorly to pool-based SOC models; as a result, we are challenged to mechanistically predict how environmental change will impact movement of carbon between soils and the atmosphere. In this study, we propose a novel conceptual framework to explore controls on belowground carbon cycling: Probabilistic Representation of Organic Matter Interactions within the Soil Environment (PROMISE). In contrast to traditional model frameworks, PROMISE does not attempt to define carbon pools united by common thermodynamic or functional attributes. Rather, the PROMISE concept considers how SOC cycling rates are governed by the stochastic processes that influence the proximity between microbial decomposers and organic matter, with emphasis on their physical location in the soil matrix. We illustrate the applications of this framework with a new biogeochemical simulation model that traces the fate of individual carbon atoms as they interact with their environment, undergoing biochemical transformations and moving through the soil pore space. We also discuss how the PROMISE framework reshapes dialogue around issues related to SOC management in a changing world. We intend the PROMISE framework to spur the development of new hypotheses, analytical tools, and model structures across disciplines that will illuminate mechanistic controls on the flow of carbon between plant, soil, and atmospheric pools.

54 ENVIRONMENTAL SCIENCES↗

3D Cloud Tomography and Droplet Size Retrieval from Multi-Angle Polarimetric Imaging of Scattered Sunlight from Above

Tomography aims to recover a three-dimensional (3D) density map of a medium or an object. In medical imaging,it is extensively used for diagnostics via X-ray computed tomography (CT). We define and derive a tomographyof cloud droplet distributions via passive remote sensing. We use multi-view polarimetric images to fit a 3Dpolarized radiative transfer (RT) forward model. Our motivation is 3D volumetric probing of vertically-developedconvectively-driven clouds that are ill-served by current methods in operational passive remote sensing. Currenttechniques are indeed based on strictly 1D RT modeling and applied to a single cloudy pixel, where cloud geometrydefaults to that of a plane-parallel slab. Incident unpolarized sunlight, once scattered by cloud droplets, changesits polarization state according to droplet size. Therefore, polarimetric measurements in the rainbow and gloryangular regions can be used to infer the droplet size distribution. This work defines and derives a framework for afull 3D tomography of cloud droplets for both their mass concentration in space and their distribution across arange of sizes. This gridded 3D retrieval of key microphysical properties is made tractable by our novel approachthat involves a restructuring and partial linearization of an open-source polarized 3D RT code to accommodate aspecial two-step iterative optimization technique. Physically-realistic synthetic clouds are used to demonstrate themethodology with rigorous uncertainty quantification, while a real-world cloud imaged by AirMSPI is processedto illustrate the new remote sensing capability

Schechner, Yoav Y.↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

Dynamic Light-Scattering Probe Used for the Very Early Detection of Cataracts and to Measure Response to Therapy (or Treatment)

Half of all blindness worldwide is due to cataracts, and 34 million Americans over the age of 65 have cataracts. This figure is expected to rise to 70 million by the year 2030. Currently, no medical treatment is available to prevent or halt the progression of a cataract; nor is there any way to reverse a cataract once it has been detected by conventional methods. The only known treatment is surgical removal of the lens. It is estimated that over $5 billion will be spent this year for the treatment of cataract patients in the United States alone. According to Carl Kupfer, M.D., former Director of the National Eye Institute at the National Institutes of Health, "A delay in cataract formation of about 10 years would reduce the prevalence of visually disabling cataracts by about 45 percent." However, this vision remains a dream because of the lack of objective methods that can be used to detect cataracts very early and, hence, can be used for screening potential anticataract drugs. This is about to change. The National Eye Institute and NASA entered into a formal interagency agreement in late 1996 to develop and test a dynamic light-scattering (DLS) device to detect the earliest changes due to cataract formation. The new DLS probe developed by Dr. Ansari at the NASA Glenn Research Center is several orders of magnitude more sensitive than conventional clinical systems. This ultrahigh sensitivity enables the probe to detect the onset of a cataract before it has any effect on vision and allows researchers to test the effectiveness of anticataract drugs in reversing cataracts. This device (see the following illustration) was originally designed to study transport phenomena in microgravity fluid physics experiments onboard the space shuttle orbiters and space station. It will be very useful in testing anticataract drugs to halt or reverse the progression of cataracts during longitudinal clinical trials.

Ansari,Rafat R.↗

The Utility of a Small Pressurized Rover with Suit Ports for Lunar Exploration: A Geologist's Perspective

Rover trade study: As summarized recently, mission simulations at Black Point Lava Flow (Arizona) that included realistic extravehicular activity (EVA) tasking, accurate traverse timelines, and an in-loop science CAPCOM (or SciCOM) showed that a small pressurized rover (SPR) was a better mobility asset than an unpressurized rover (UPR). Traverses within the SPR were easier on crew than spending an entire day in a spacesuit, enhancing crew productivity at each station. The SPR, named Lunar Electric Rover (LER), and sometimes called the Space Exploration Vehicle (SEV), could also provide shelter during a suit malfunction, radiation event, or medical emergency that might occur on the Moon. Intravehicular activity (IVA) capabilities: From within the vehicle, crew could describe and photo-document distant features during drives between stations, as well as in the near-field, directly in front of the LER, providing an ability to begin EVA planning on approach to each outcrop prior to egress. The vehicle can rotate 360º without any lateral movement, providing views in all directions. It has high-visibility windows, a ForeCam, AftCam, port and starboard cameras, docking cameras, and a GigaPan camera. EVA capabilities: To reduce timeline, mass, and volumetric overhead, rapid egress and ingress were envisioned, replacing an airlock with lower cabin pressure than on the International Space Station and suit ports on the aft cabin wall [2]. When needed for closer inspection and sample collecting, crew could egress in about 10 minutes through suit ports. Crew use SuitCams for additional photo-documentation, transmit mobile observations verbally, and collect surface materials. Typical simulations involved 3 to 4 EVA stations/day and 2 to 3 hr/day of boots on the ground. This allowed crew to explore a far larger territory, with more complex geological and in situ resource utilization (ISRU) features, than would a single, longer-duration EVA at one location, while also minimizing crew time in a spacesuit. Additionally, the vehicle could be driven with crew locked into the suit ports. This approach could involve a driver in the cockpit with a suited crewmember in a suit port, or the vehicle could be driven from the aft deck with both crewmembers in their suit ports. This approach was used when distances between stops were short enough that vehicle ingress and egress were less efficient than remaining in the suits and driving. Utility of suit ports: The advantages of suit ports were clearly demonstrated in those field-based trade studies. To illustrate those advantages further, consider the consequences of a SPR without suit ports at the Apollo 17 landing site. At that site, the crew's second EVA was an approximately 18 km loop conducted in a UPR, called the Lunar Roving Vehicle (LRV), in 7 hr 36 min 56 s. The traverse was composed of 5 formal stations, plus 8 additional LRV stations where crew made brief scientific stops. In a scenario involving a SPR without suit ports, crew would go EVA through an airlock and probably be limited to a single EVA per day. In that case, crew could drive the SPR ~9 km from the landing site to station 2, go EVA, and complete station 2 tasks. However, to conduct station 3 tasks, the crew would then need to walk approximately 3 km to station 3, while ground control in Houston tele-robotically drives the LER to station 3. A walk of approximately 3 km is possible, as that is what the Apollo 14 crew did before LRVs were deployed, but it is a lengthy and potentially grueling EVA. Assuming crew completes station 3 tasks, they would likely need to re-enter the SPR, ending the day's EVA, and return to the landing site. They would not be able to walk the additional distances to stations 4 and 5 (the latter being about 6 km from station 3). Thus, crew in an SPR without suit ports would require two days to accomplish the same tasks Apollo 17 crew completed in a single day. If a future crew is involved in long duration traverses on the lunar surface, the deployment of a vehicle with suit ports would probably be a better solution.

Kring, David A.↗

Nanoengineered Shape-Memory Hemostat

Uncontrolled hemorrhage is the predominant cause of preventable combat deaths. Various biomaterials serve as hemostatic agents due to their procoagulant or absorptive activity. However, these biomaterials often lack expansion capabilities, which severely limits use in noncompressible wounds. This study combines a hemostatic nanocomposite with a shape-memory polymer foam to design a composite material with both hemostatic and physical expansion properties. This composite is fabricated in two formulations: a foam externally coated in a highly concentrated nanocomposite (“coated composite”) and a foam containing a diluted nanocomposite infused throughout its pores (“infused composite”). Both formulations retain the shape-memory foam's expansion property. Further, the coated composite shows improved fluid uptake (>2-fold) versus infused composites or foam. The nanocomposite component dissociates from the foam under degradative conditions, with the foam remaining stable for 30 days. Hemostatic studies illustrate that the coated composite reduces the clotting time by ≈20%. Alternatively, the infused composite improves clotting over a larger distance (up to ≈2× distance from the composite). These results signify a modular hemostatic ability: the coated composite reduces clotting and improves fluid uptake, while the infused composite achieves diffuse clotting and maintains mechanical properties. Thus, these materials pose a strong potential for use in noncompressible wounds.

60 APPLIED LIFE SCIENCES↗

The Recovery of Medical Isotope 188 W from Irradiated W Metal Target - A New Approach

Tungsten-188 is in widespread use in 188 W(t 1/2 = 69 d )/ 188 Re(t 1/2 = 16.9 h ) biomedical generators. Oak Ridge National Laboratory has been providing this product to the world since 1999. At ORNL, 188 W is produced via irradiation in ORNL’s High Flux Isotope Reactor (HFIR). Enriched 186 W targets in the form of sintered metallic pellets or rings achieve a compact loading in the irradiation vessel, providing a high yield per unit target. The enrichment of the target is >90% 186 W, and this isotope undergoes double neutron capture to produce the desired 188 W product. While 188 W is produced by neutron bombardment, 191 Os(t 1/2 = 15.4 d ) is simultaneously produced as a by-product and expected to be separated from 188 W by postirradiation treatment.In the current processing pathway, the irradiated W metal rings are first converted into an oxide form of WO 3 by heating the irradiated W metal target at 750°C in a quartz reaction vessel inside a vertical furnace under a constant flow of air. During heating, W metal reacts with oxygen in the air to produce WO 3 , which is soluble in 6 M NaOH for preparation of 188 W product. This oxidation process also converts 188 Os (the decay daughter of 188 W) and 191 Os (15.4 d , the irradiation produced byproduct) into OsO 4 , a highly volatile and toxic gas. The gaseous effluents driven from the quartz reaction vessel are passed through a scrubbing array to remove OsO 4 before the air is discharged from the process. This heterogeneous oxidation method simultaneously achieves goals of (1) converting metal target to a soluble oxide form and (2) removing volatile OsO 4 away from the solid WO 3 product by air flow and absorbing the harmful Os species by the scrubbing array. But this method has two potential problems as well: (1) O 2 reacts with only W metal at high temperatures, not with W alloyed with other elements. The O 2 –W reaction will be retarded when formation of WRe or WC occurs, or even when a layer of non-W materials on the surface of the irradiated W rings.; (2) 100% absorption of OsO 4 of high yield (>90%) from the reaction of Os + O 2 is a strict requirement to the OsO 4 scrubbing system--so NaOH scrubbers of a redundant size (2x 1.5 L) are in use for safety reasons.To resolve above two potential problems, direct dissolution of the irradiated W metal target by a selected reagent is a preferred pathway to avoid heating step with generation of tremendous amount of volatile OsO 4 . Hydrogen peroxide (H 2 O 2 ) is such a candidate to dissolve W in forms of either metal or alloys, although literature lacks information of solubilities of Re or Os in H 2 O 2 . With experimental results of dissolving non-radioactive W, Re and Os in H 2 O 2 under various conditions, this report illustrates a method of H 2 O 2 dissolution for irradiated W target, with a complete dissolution of W and Re, but ≤10% dissolution of Os (converted into gaseous OsO 4 and carried out into a scrubbing for absorption) during processing irradiated W target. The portion of undissolved Os can be separated from W solution by a follow up filtration step. Solubilities of W, Re and Os in H 2 O 2 at a temperature range from 14° to 50°C are presented. And a dissolution rate of W metal per surface area of W metal in H 2 O 2 is calculated based on results of dissolving a W metal cylinder of known surface area in H 2 O 2 at room temperature without stirring.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison and multi-model inference of excess risks models for radiation-related solid cancer

In assessments of detrimental health risks from exposures to ionising radiation, many forms of risk to dose–response models are available in the literature. The usual practice is to base risk assessment on one specific model and ignore model uncertainty. The analysis illustrated here considers model uncertainty for the outcome all solid cancer incidence, when modelled as a function of colon organ dose, using the most recent publicly available data from the Life Span Study on atomic bomb survivors of Japan. Seven recent publications reporting all solid cancer risk models currently deemed plausible by the scientific community have been included in a model averaging procedure so that the main conclusions do not depend on just one type of model. The models have been estimated with different baselines and presented for males and females at various attained ages and ages at exposure, to obtain specially computed model-averaged Excess Relative Risks (ERR) and Excess Absolute Risks (EAR). Monte Carlo simulated estimation of uncertainty on excess risks was accounted for by applying realisations including correlations in the risk model parameters. Three models were found to weight the model-averaged risks most strongly depending on the baseline and information criteria used for the weighting. Fitting all excess risk models with the same baseline, one model dominates for both information criteria considered in this study. Based on the analysis presented here, it is generally recommended to take model uncertainty into account in future risk analyses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

LDRD FY25 Program Overview

As Lawrence Livermore National Laboratory’s (LLNL’s) Laboratory Directed Research and Development (LDRD) program enters its fifth decade of leading-edge research and development, its impact and importance have never been stronger. The program continues to advance strategic investments in pioneering science, technology, and engineering, ensuring LLNL will be ready to deliver on our mission as it evolves over the coming decades. Investing in LDRD research, and the people who perform this critical work, gives LLNL the ability to sustain our role as a leader in the Department of Energy and National Nuclear Security Administration enterprise. The LDRD program enables high-risk, high-payoff research that anticipates emerging threats and future mission needs. By nurturing the ingenuity of the Lab’s greatest asset, its people, LDRD funding advances not only our research but also grows and nurtures our workforce: engaging future innovators with student mentoring, challenging postdoctoral researchers to apply their skills to support national security, and strengthening the leadership skills of early career staff. This annual report documents how LDRD investments advance LLNL’s science, technology, and engineering across our mission space. To assess LDRD’s impact we track both short and long-term metrics such as peer-reviewed publications, number of students, or professional fellows. In addition to reviewing these metrics, I encourage you to delve deeper into the breadth of science and technology that illustrate the strategic value of this research portfolio. For instance, a recent exploratory research project used advanced manufacturing to construct miniaturized three-dimensional ion traps for a quantum computer with reduced quantum error rates to enable applications that address national security missions and support basic science. Another project has delved into studying detonation by examining deflagration to enhance the safety and security of the nuclear weapons stockpile. LDRD researchers are also deploying AI agents on two of the world’s most powerful supercomputers to automate and accelerate inertial confinement fusion experiments. Other teams are delivering more accurate optical constants to enable improved validation for aluminum to advance atomic and molecular physics models. LDRD-driven discoveries of how metals deform under extreme conditions strengthen our ability to model and design materials for demanding national security environments. National security challenges are increasingly complex and continuously evolving. LDRD focuses our most innovative science and technology on these challenges, ensuring the Laboratory is developing creative, forward-leaning solutions for our nation and the world. The following pages feature highlights of published scientific advances, patents, and honors that stem from LDRD investments. As you read this report, I hope you will understand how these investments position the Laboratory, and our partners, to meet the demands of the decades ahead.

36 MATERIALS SCIENCE↗

Animal movement estimation and network-based epidemic modeling: Illustration for the swine industry in Iowa (US)

Animal movement plays a critical role in disease transmission between farms. However, in the United States, the lack of available animal shipment data, sometimes coupled with a lack of detailed information about farm demographics and characteristics, presents great challenges for epidemic modeling and prediction. In this study, we proposed a new method based on the maximum entropy to generate “synthetic” animal movement networks, considering available statistics about the premises operation type, operation size, and the distance between premises. We illustrated our method for the swine movement networks in Iowa and performed network analyses to gain insights into the swine industry. We then applied the generated networks to a network-based epidemic model to identify potential system vulnerabilities in terms of disease transmission. The model was parameterized for African Swine Fever (ASF) as the US swine industry is quite concerned about this disease. Results show that premises with a central role in the network are more vulnerable to disease outbreaks and play an important role in disease spread. Simulations with outbreaks starting from random farms reveal no significant large outbreaks, indicating the system’s relative robustness against arbitrary disease introductions. However, outbreaks originating from high out-degree farms can lead to large epidemic sizes. This underscores the importance for stakeholders and policymakers to continue improving animal movement records and traceability programs in the US and the value of making that data available to epidemiologists and modelers to better understand risk and inform strategies aimed to cost-effectively prevent and control disease transmission. Our approach could be easily adapted to estimate movement networks in other animal production systems and to inform disease spread models for various infectious diseases.

60 APPLIED LIFE SCIENCES↗