Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mechanical loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Response Of Mineralizing And Non-Mineralizing Bone Cells To Fluid Flow: An In Vitro Model For Mechanotransruction

Humans reach peak bone mass at age 30. After this point, we lose 1 to 2 percent of bone mass each decade. In the microgravity environment of space, astronauts lose bone mass at an accelerated rate of 1 to 2 percent each month. When astronauts travel to Mars, they may be in space for as long as 3 years. During this time, they may lose about half of their bone mass from weight-bearing bones. This loss may be irreversible. The drastic loss in bone that astronauts experience in space makes them much more vulnerable to fractures. In addition, the corresponding removal of calcium from bone results in higher levels of calcium in the blood, which increases the risk of developing kidney stones. Currently, studies are being conducted which investigate factors governing bone adaptation and mechanotransduction. Bone is constantly adapting in response to mechanical stimuli. Increased mechanical loading stimulates bone formation and suppresses bone resorption. Reduction in mechanical loading caused by bedrest, disuse, or microgravity results in decreased bone formation and possibly increased bone resorption. Osteoblasts and osteoclasts are the two main cell types that participate in bone remodeling. Osteoblasts are anabolic (bone-forming) cells and osteoclasts are catabolic (bone-resorbing) cells. In microgravity, the activity of osteoblasts slows down and the activity of osteoclasts may speed up, causing a loss of bone density. Mechanotransduction, the molecular mechanism by which mechanical stimuli are converted to biochemical signals, is not yet understood. Exposure of cells to fluid flow imposes a shear stress on the cells. Several studies have shown that the shear stress that results from fluid flow induces a cellular response similar to that induced by mechanical loading. Thus, fluid flow can be used as an in vitro model to simulate the mechanical stress that bone cells experience in vivo. Previous in vitro studies have shown that fluid flow induces several responses in osteoblasts, including increased proliferation, osteoblastic differentiation, alkaline phosphatase activity, and production of nitric oxide, prostaglandins, and osteopontin. Several proteins have been implicated in osteoblastic mechanotransduction including Bone Morphogenetic Protein-2 (BMP-2), parathyroid hormone, 1,25-dihydroxyvitamin D3 receptor, osteopontin (OPN), osteoprotegerin (OPG), and alkaline phosphatase (AP). We will characterize relative levels of each protein in mineralizing or non-mineralizing MC3T3 osteoblastic cells that have been exposed to fluid flow compared to non-fluid flow using immunofluorescent staining and two- photon laser microscopy as well as western blotting. Because calcium-mediated pathways are important in osteoblastic signaling, we will transfect MC3T3 cells with cameleon probes for Ca2+ containing YFP and CFP. Results will be analyzed using FRET/FLIM to study differential release of intracellular Ca(2+) in response to fluid flow and conditions inducing matrix mineralization. In addition, we plan to conduct several microarray experiments to determine differential gene expression in MC3T3 cells in response to fluid flow and conditions inducing mineralization.

Makuch, Lauren A.↗

Electrochemical Response of Alkaline Batteries Subject to Quasi-Static and Dynamic Loading

We report electrochemical changes were successfully monitored through the coupling of external loading, electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. The development of the testing methods allows for detailed observation of changes due to mechanical loading and distinguishes responses between different cell geometries. Comparison of the force vs displacement, voltage vs displacement, and distribution of relaxation times plots to the different cell geometries display failure modes specific to geometry as well as the impact of different loading profiles. Numerical modeling confirmed the movement within individual cells and predicted locations with the most deformation based on the external loading condition applied. The results gathered from combining mechanical loading, electrochemical response, and numerical modeling, yield a viable approach to establishing an improved understanding of the effects of mechanical loading on the electrochemical response of multiple battery geometries and the methods herein may be extensible to additional battery chemistries.

25 ENERGY STORAGE↗

Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.

Seale, Michael D.↗

Retrospective Analysis of Inflight Exercise Loading and Physiological Outcomes

Astronauts perform exercise throughout their missions to counter the health declines that occur as a result of long-term exposure to weightlessness. Although all astronauts perform exercise during their missions, the specific prescriptions, and thus the mechanical loading, differs among individuals. For example, inflight ground reaction force data indicate that subject-specific differences exist in foot forces created when exercising on the second-generation treadmill (T2) [1]. The current exercise devices allow astronauts to complete prescriptions at higher intensities, resulting in greater benefits with increased efficiency. Although physiological outcomes have improved, the specific factors related to the increased benefits are unknown. In-flight exercise hardware collect data that allows for exploratory analyses to determine if specific performance factors relate to physiological outcomes. These analyses are vital for understanding which components of exercise are most critical for optimal human health and performance. The relationship between exercise performance variables and physiological changes during flight has yet to be fully investigated. Identifying the critical performance variables that relate to improved physiological outcomes is vital for creating current and future exercise prescriptions to optimize astronaut health. The specific aims of this project are: 1) To quantify the exercise-related mechanical loading experienced by crewmembers on T2 and ARED during their mission on ISS; 2) To explore relationships between exercise loading variables, bone, and muscle health changes during the mission; 3) To determine if specific mechanical loading variables are more critical than others in protecting physiology; 4) To develop methodology for operational use in monitoring accumulated training loads during crew exercise programs. This retrospective analysis, which is currently in progress, is being conducted using data from astronauts that have flown long-duration missions onboard the ISS and have had access to exercise on the T2 and the Advanced Resistive Exercise Device (ARED). The specific exercise prescriptions vary for each astronaut. General exercise summary metrics will be developed to quantify exercise intensities, volumes, and durations for each subject. Where available, ground reaction force data will be used to quantify mechanical loading experienced by each astronaut. These inflight exercise metrics will be investigated relative to changes in pre- to post-flight bone and muscle health to identify which specific variables are related with improved or degraded physiological outcomes. The information generated from this analysis will fill gaps related to typical bone loading characterization, exercise performance capability, exercise volume and efficiency, and importance of exercise hardware. In addition, methods for quantification of exercise loading for use in monitoring the exercise programs during future space missions will be explored with the intent to inform exercise scientists and trainers as to the critical aspects of inflight exercise prescriptions.

Ploutz-Snyder, L. L.↗

Selected Contribution: Skeletal muscle focal adhesion kinase, paxillin, and serum response factor are loading dependent

This investigation examined the effect of mechanical loading state on focal adhesion kinase (FAK), paxillin, and serum response factor (SRF) in rat skeletal muscle. We found that FAK concentration and tyrosine phosphorylation, paxillin concentration, and SRF concentration are all lower in the lesser load-bearing fast-twitch plantaris and gastrocnemius muscles compared with the greater load-bearing slow-twitch soleus muscle. Of these three muscles, 7 days of mechanical unloading via tail suspension elicited a decrease in FAK tyrosine phosphorylation only in the soleus muscle and decreases in FAK and paxillin concentrations only in the plantaris and gastrocnemius muscles. Unloading decreased SRF concentration in all three muscles. Mechanical overloading (via bilateral gastrocnemius ablation) for 1 or 8 days increased FAK and paxillin concentrations in the soleus and plantaris muscles. Additionally, whereas FAK tyrosine phosphorylation and SRF concentration were increased by < or =1 day of overloading in the soleus muscle, these increases did not occur until somewhere between 1 and 8 days of overloading in the plantaris muscle. These data indicate that, in the skeletal muscles of rats, the focal adhesion complex proteins FAK and paxillin and the transcription factor SRF are generally modulated in association with the mechanical loading state of the muscle. However, the somewhat different patterns of adaptation of these proteins to altered loading in slow- vs. fast-twitch skeletal muscles indicate that the mechanisms and time course of adaptation may partly depend on the prior loading state of the muscle.

NASA Discipline Musculoskeletal↗

Temporal gradients in shear stimulate osteoblastic proliferation via ERK1/2 and retinoblastoma protein

Bone cells are subject to interstitial fluid flow (IFF) driven by venous pressure and mechanical loading. Rapid dynamic changes in mechanical loading cause transient gradients in IFF. The effects of pulsatile flow (temporal gradients in fluid shear) on rat UMR106 cells and rat primary osteoblastic cells were studied. Pulsatile flow induced a 95% increase in S-phase UMR106 cells compared with static controls. In contrast, ramped steady flow stimulated only a 3% increase. Similar patterns of S-phase induction were also observed in rat primary osteoblastic cells. Pulsatile flow significantly increased relative UMR106 cell number by 37 and 62% at 1.5 and 24 h, respectively. Pulsatile flow also significantly increased extracellular signal-regulated kinase (ERK1/2) phosphorylation by 418%, whereas ramped steady flow reduced ERK1/2 activation to 17% of control. Correspondingly, retinoblastoma protein was significantly phosphorylated by pulsatile fluid flow. Inhibition of mitogen-activated protein (MAP)/ERK kinase (MEK)1/2 by U0126 (a specific MEK1/2 inhibitor) reduced shear-induced ERK1/2 phosphorylation and cell proliferation. These findings suggest that temporal gradients in fluid shear stress are potent stimuli of bone cell proliferation.

NASA Discipline Cell Biology↗

On local total strain redistribution using a simplified cyclic inelastic analysis based on an elastic solution

Strain redistribution corrections were developed for a simplified inelastic analysis procedure to economically calculate material cyclic response at the critical location of a structure for life prediction purposes. The method was based on the assumption that the plastic region in the structure is local and the total strain history required for input can be defined from elastic finite element analyses. Cyclic stress-strain behavior was represented by a bilinear kinematic hardening model. The simplified procedure has been found to predict stress-strain response with reasonable accuracy for thermally cycled problems but needs improvement for mechanically load cycled problems. This study derived and incorporated Neuber type corrections in the simplified procedure to account for local total strain redistribution under cyclic mechanical loading. The corrected simplified method was exercised on a mechanically load cycled benchmark notched plate problem. Excellent agreement was found between the predicted material response and nonlinear finite element solutions for the problem. The simplified analysis computer program used 0.3 percent of the CPU time required for a nonlinear finite element analysis.

Hwang, S. Y.↗

On local total strain redistribution using a simplified cyclic inelastic analysis based on an elastic solution

Strain redistribution corrections were developed for a simplified inelastic analysis procedure to economically calculate material cyclic response at the critical location of a structure for life prediction purposes. The method was based on the assumption that the plastic region in the structure is local and the total strain history required for input can be defined from elastic finite element analyses. Cyclic stress-strain behavior was represented by a bilinear kinematic hardening model. The simplified procedure has been found to predict stress-strain response with reasonable accuracy for thermally cycled problems but needs improvement for mechanically load cycled problems. This study derived and incorporated Neuber type corrections in the simplified procedure to account for local total strain redistribution under cyclic mechanical loading. The corrected simplified method was exercised on a mechanically load cycled benchmark notched plate problem. Excellent agreement was found between the predicted material response and nonlinear finite element solutions for the problem. The simplified analysis computer program used 0.3 percent of the CPU time required for a nonlinear finite element analysis.

Hwang, S. Y.↗

Probabilistic Assessment of Adaptive Space Truss Configurations for Thermal Buckling Resistance

A three-bay, cantilever truss of a type typically used in space structures, is probabilistically evaluated to configure adaptive/smart/intelligent behavior for resisting thermal buckling. This buckling is due to nonuniform thermal loads and a combination of these loads with applied loads and moments (mechanical loads). For each behavior the scatter (ranges) in buckling loads and member axial forces are probabilistically determined. Sensitivities associated with uncertainties in the structural and material variables that describe the truss, as well as scatter in mechanical and thermal loads, are determined for different probabilities. The relative magnitude of these sensitivities are used to identify significant truss variables that control/classify the truss behavior and cause it to respond as an adaptive/smart/ intelligent structure. Results show that the probabilistic buckling loads increase for adaptive and intelligent truss classifications, with a substantial increase for intelligent trusses. Similarly, the probabilistic member axial forces decrease for each truss classification.

Pai, Shantaram S.↗

Effect of Cr and Ni concentrations on resilience of cast Nb- alloyed heat resistant austenitic steels at extreme high temperatures

Austenitic Cr–Ni alloyed heat resistant steels with Nb additions are used for intensively thermo-mechanically loaded cast components working in extreme high temperature oxidizing environment. Their performance during static oxidation and transient thermo-mechanical loading was investigated to recommend an optimal cost-effective Cr/Ni composition of Nb-alloyed austenitic class steels. Here, the static oxidation and transient thermo-mechanical behavior of three austenitic steels with different Cr/Ni alloying levels were investigated and compared for variety of working conditions. Static oxidation was performed between 900 °C and 1000 °C in air for 400 h. The critical temperature which increases spallation during static oxidation was determined for each of the steel alloying levels. In addition, thermal cycling of a constrained specimen was done with varying upper cycling temperatures between 850 °C and 1000 °C. SEM and TEM analyses were supported by thermodynamic simulation of the phases precipitated in the metal matrix and the structure of formed oxide layers. These studies were used to determine the mechanisms of degradation of thermo-mechanically loaded Cr/Ni austenitic steels at extreme high temperatures. A recommendation for a cost-effective Cr/Ni alloying level for different working conditions was determined.

36 MATERIALS SCIENCE↗

Effect of Transverse Compression on the Dielectric Breakdown of Power Cable with Ethylene Propylene Rubber Insulation

Understanding of the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project explored a multiphysics approach and conducted systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15 kV power cable. The power cable had three cores of copper conductor and ethylene propylene rubber (EPR) insulation. An ETM testing system with transverse compression capability was developed. Mechanical loading induced dielectric breakdown. Increasing temperature from room temperature (RT, 22 degrees Celsius) to 90 degrees Celsius resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. With the same temperature rise, the creep mechanical load was reduced by 70% at a given dielectric breakdown time. The post-test measurement revealed an impressive recovery of electrical resistance, although the dielectric breakdown occurred in the ETM test that would not be captured without the use of ETM testing.

Wang, Hong [ORNL] (ORCID:0000000201730545)↗

Mechanical Unloading Effects Hematopoiesis and Subsequent Red Blood Cell Life Cycle Evaluated at Singe Cell Resolution

Red blood cell formation or erythropoiesis in the bone marrow and exit into circulation are known to be affected by mechanical loading. Specifically, space anemia is a condition observed during prolonged microgravity unloading in which the red blood cell (RBC) mass in circulation is reduced. However, the mechanisms causing space anemia are yet to be clearly established, but may include increased hemolysis of RBC in circulation, decreased RBC production or a combination of both factors. The presentation of space anemia is comparable to chronic anemia conditions associated with aging, disuse, and poor health. Molecular dysregulation in the RBC's life cycle is poorly defined and is a significant concern in the context of disuse anemia as mechanotransduction significantly alters of gene expression, protein synthesis and cell signaling pathways. Our study analyzes mouse single cell RNA sequencing libraries from the bone marrow, circulating blood, and spleen and integrates the RBC lineage populations from the tissues into a RBC life cycle atlas. This study also probes how age at time of spaceflight contributes to the molecular signature of space anemia. The overarching objective of the study is to develop a mechanistic understanding of space anemia and translate the findings to a better understanding of aging, disuse, and poor health-related anemia to defining the role of mechanical loading in health and devise potential therapeutic interventions. Important findings of our study are: 1) that mechanical unloading in microgravity alters the proportion of developmental RBC lineage cells, skewing toward progenitor, indicating that fewer RBCs may be present in blood; 2) that late reticulocyte number is elevated in the bone marrow of older animals, suggesting a failure to enter circulation; and 3) that the molecular signature of the circulating RBCs is not significantly altered in microgravity. However, expression markers for eryptosis and erythrophagocytosis are elevated in circulating and spleen RBCs, suggesting spaceflight may shorten the lifetime of RBCs after exit from the marrow. In conclusion our results suggest early stages of erythropoiesis proliferation and differentiation in the marrow are key factors in space anemia and mechanical loading may be a necessary step of RBC entry in circulation.

blood↗

Thermal-Structural Analysis of PICA Tiles for Solar Tower Test

Thermal protection materials used in spacecraft heatshields are subjected to severe thermal and mechanical loading environments during re-entry into earth atmosphere. In order to investigate the reliability of PICA tiles in the presence of high thermal gradients as well as mechanical loads, the authors designed and conducted solar-tower tests. This paper presents the design and analysis work for this tests series. Coupled non-linear thermal-mechanical finite element analyses was conducted to estimate in-depth temperature distribution and stress contours for various cases. The first set of analyses performed on isolated PICA tile showed that stresses generated during the tests were below the PICA allowable limit and should not lead to any catastrophic failure during the test. The tests results were consistent with analytical predictions. The temperature distribution and magnitude of the measured strains were also consistent with predicted values. The second test series is designed to test the arrayed PICA tiles with various gap-filler materials. A nonlinear contact method is used to model the complex geometry with various tiles. The analyses for these coupons predict the stress contours in PICA and inside gap fillers. Suitable mechanical loads for this architecture will be predicted, which can be applied during the test to exceed the allowable limits and demonstrate failure modes. Thermocouple and strain-gauge data obtained from the solar tower tests will be used for subsequent analyses and validation of FEM models.

Agrawal, Parul↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage, and with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage. In combination with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

A concurrent irradiation-mechanics multiscale coupling model

The vast majority of our current knowledge regarding the basic mechanisms controlling irradiation effect on mechanical properties is based almost entirely on the results of post-irradiation experiments or theoretical models. However, the concurrent effects of irradiation, mechanical stress, and thermal damage on the failure phenomena of materials and components remain largely unexplored due to its internal multiscale-multiphysics coupling nature. Here, we present here a concurrent irradiation-mechanics multiscale coupling model. The concurrent evolutions of nanoscale irradiation defect clusters, microscale dislocation configurations, and mechanical responses are well captured based on coupling cluster dynamics, discrete dislocation dynamics, and the finite element methods using an effective time marching scheme. Model predictions of defect densities and size are in general agreement with experimental observations. Irradiation hardening is shown to take place also in samples undergoing concurrent irradiation-mechanical loading, similar to samples tested post-irradiation. However, the occurrence of plastic flow localization and dislocation channel formation is not accompanied with apparent yield drop (softening) under concurrent irradiation-mechanical loading conditions, which is different from the post-irradiation case.

42 ENGINEERING↗

Effects of Cyclic Loading on Mechanical Behavior of 24S-T4 and 75S-T6 Aluminum Alloys and SAE 4130 Steel

An investigation was conducted to determine the effects of cyclic loading on the mechanical behavior of 24S-T4 and 75S-T6 aluminum alloys and SAE 4130 steel. Specimens of the three materials were subjected to various numbers of prior fatigue cycles both below and above the fatigue limits. Special slow-bend tests were employed to show the effects of prior cycles of fatigue stressing on the transition temperature to brittle fracture for SAE 4130 steel and on the energy-absorption capacity of the aluminum alloys. Micrographic studies were made to observe and measure crack formation and propagation and additional special tests were conducted to supplement the results of the slow-bend tests. These included Charpy impact tests, mirohardness surveys, tension tests, and fretting-corrosion studies.

STEELS↗

Structural Modeling of an Osteoblast Subjected to Hypergravity Loading

Osteoblasts, the bone-forming cells, are sensitive to altered mechanical loads such as those induced by fluid shear forces and cyclic uniaxial tension and compression. The cytoskeleton is thought to play an important role in a cell's response to mechanical loading and to coordinate cell shape changes. While some theoretical calculations indicate that a cell should not be able to respond to relatively small changes in gravity given the magnitude of forces exerted by intracellular components, osteoblasts have been shown to respond to microgravity. In this study, we investigated whether an osteoblast can sense a constant hypergravity acceleration of 10G. We asked if this load changes the shape of an osteoblast, and if engineering modeling accurately predicts the shape change. We modeled a cell by representing it as a series of axisymmetric shell structures. To test this model empirically, we performed experiments with cultured osteoblasts to measure changes in cell shape resulting from hypergravity loading.

Globus, Ruth K.↗