Automatic Alignment of Displacement-Measuring Interferometer

A control system strives to maintain the correct alignment of a laser beam in an interferometer dedicated to measuring the displacement or distance between two fiducial corner-cube reflectors. The correct alignment of the laser beam is parallel to the line between the corner points of the corner-cube reflectors: Any deviation from parallelism changes the length of the optical path between the reflectors, thereby introducing a displacement or distance measurement error. On the basis of the geometrical optics of corner-cube reflectors, the length of the optical path can be shown to be L = L(sub 0)cos theta, where L(sub 0) is the distance between the corner points and theta is the misalignment angle. Therefore, the measurement error is given by DeltaL = L(sub 0)(cos theta - 1). In the usual case in which the misalignment is small, this error can be approximated as DeltaL approximately equal to -L(sub 0)theta sup 2/2. The control system (see figure) is implemented partly in hardware and partly in software. The control system includes three piezoelectric actuators for rapid, fine adjustment of the direction of the laser beam. The voltages applied to the piezoelectric actuators include components designed to scan the beam in a circular pattern so that the beam traces out a narrow cone (60 microradians wide in the initial application) about the direction in which it is nominally aimed. This scan is performed at a frequency (2.5 Hz in the initial application) well below the resonance frequency of any vibration of the interferometer. The laser beam makes a round trip to both corner-cube reflectors and then interferes with the launched beam. The interference is detected on a photodiode. The length of the optical path is measured by a heterodyne technique: A 100- kHz frequency shift between the launched beam and a reference beam imposes, on the detected signal, an interferometric phase shift proportional to the length of the optical path. A phase meter comprising analog filters and specialized digital circuitry converts the phase shift to an indication of displacement, generating a digital signal proportional to the path length.

Halverson, Peter↗

Laser Pyrometer For Spot Temperature Measurements

Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

Elleman, D. D.↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Monte Carlo Study of Imaging Plate Response to Laser-Driven Aluminum Ion Beams

We measured the response of BAS-TR imaging plate (IP) to energetic aluminum ions up to 222 MeV, and compared it with predictions from a Monte Carlo simulation code using two different IP response models. Energetic aluminum ions were produced with an intense laser pulse, and the response was evaluated from cross-calibration between CR-39 track detector and IP energy spectrometer. For the first time, we obtained the response function of the BAS-TR IP for aluminum ions with a kinetic energy as high as 222 MeV. On close examination of the two IP response models, we confirm that the exponential model fits our experimental data better. Moreover, we find that the IP sensitivity in the exponential model is nearly constant in this energy range, suggesting that the response function can be determined even with little experimental data.

Won, Junho↗

Pinhole Calibrator For Particle-Sizing Instrument

Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.

Hovenac, Edward↗

Laser beam methane detector

Instrument uses infrared absorption to determine methane concentration in liquid natural gas vapor. Two sensors measure intensity of 3.39 mm laser beam after it passes through gas; absorption is proportional to concentration of methane. Instrument is used in modeling spread of LNG clouds and as leak detector on LNG carriers and installations. Unit includes wheels for mobility and is both vertically and horizontally operable.

Hinkley, E. D., Jr.↗

Optical Extinction Measurements of Laser Side-Scatter During Tropical Storm Colin

A side-scatter imaging (SSI) technique using a 447 nm, 500 mW laser and a Nikon D80 camera was tested at Kennedy Space Center, Florida during the passing of a rain band associated with Tropical Storm Colin. The June 6, 2016, 22:00 GMT rain event was intense but short-lived owing to the strong west-to-east advection of the rain band. An effort to validate the optical extinction measurement was conducted by setting up a line of three tipping rain gauges along an 80 m east-west path and below the laser beam. Differences between tipping bucket measurements were correlated to the extinction coefficient profile along the lasers path, as determined by the SSI measurement. In order to compare the tipping bucket to the optical extinction data, a Marshall-Palmer DSD model was assumed. Since this was a daytime event, the laser beam was difficult to detect in the camera images, pointing out an important limitation of SSI measurements: the practical limit of DSD density that can be effectively detected and analyzed under daylight conditions using this laser and camera, corresponds to a fairly moderate rainfall rate on the order of 20 mmh (night measurements achieve a much improved sensitivity). The SSI analysis model under test produced promising results, but in order to use the SSI method for routine meteorological studies, improvements to the math model will be required.

optical extinction↗

Monitoring atmospheric pollutants with a heterodyne radiometer transmitter-receiver

The presence of selected atmospheric pollutants can be determined by transmitting an infrared beam of proper wavelength through the atmosphere, and detecting the reflections of the transmitted beam with a heterodyne radiometer transmitter-receiver using part of the laser beam as a local oscillator. The particular pollutant and its absorption line strength to be measured are selected by the laser beam wave length. When the round-trip path for the light is known or measured, concentration can be determined. Since pressure (altitude) will affect the shape of the molecular absorption line of a pollutant, tuning the laser through a range of frequencies, which includes a part of the absorption line of the pollutant of interest, yields pollutant altitude data from which the altitude and altitude profile is determined.

Menzies, R. T.↗

Aging Mechanisms of Broad Area ~800 nm Laser Diodes

Here, this work presents a comprehensive study of early aging behavior (<500 hr) in ~800 nm, phosphide-based laser diodes grown by solid-source MBE with different oxygen concentration levels incorporated into the diode epitaxial layers during growth. The data indicate that lasing characteristics prior to aging are degraded by oxygen introduction, but the gradual power degradation rate after the onset of aging is not a strong function of oxygen at these concentration levels. Devices with oxygen concentrations of ~2.5 × 10 15 cm -3 showed significantly longer delay before the onset of aging (incubation time) than devices with less than 1 × 10 15 cm -3 oxygen. Generation-Recombination current and Laser Beam Induced Current measurements indicate that defect densities and aggregation are suppressed at the facets by oxygen, which can explain longer incubation times. Diagnostic data and parametric fits to diode simulation models show that increased cavity optical loss and defect density are primarily responsible for gradual power degradation during aging, rather than changes in nonradiative recombination. Mechanisms are proposed that explain this behavior, based on density functional theory (DFT) simulations and known recombination-enhanced defect generation phenomena.

47 OTHER INSTRUMENTATION↗

Determination of atmospheric structure function by using a single coherent detector

A technique is described and analyzed for using the single beam laser receiver to measure the wave structure function of atmospheric turbulence. The measurement procedure is as follows: first, the telescope aperture is masked with an opaque screen having two small holes; one hole is covered and the output of the laser receiver is measured; finally, the output of the laser receiver is measured with both holes uncovered. By repeating these measurements for different hole separations, the wave structure function can be derermined.

Lang, R. H.↗

LEAPS (Laser electro-optical alignment pole for surveying)

Azimuthal bearing between two obscured points is measured by placing laser beam at one of the points. Beam is directed straight up into the air so that some part of it may be detected from any position a reasonable distance away.

Caudill, L.↗

Large area sheet task. Advanced dendritic web growth development

The development of a silicon dendritic web growth machine is discussed. Several refinements to the sensing and control equipment for melt replenishment during web growth are described and several areas for cost reduction in the components of the prototype automated web growth furnace are identified. A circuit designed to eliminate the sensitivity of the detector signal to the intensity of the reflected laser beam used to measure melt level is also described. A variable speed motor for the silicon feeder is discussed which allows pellet feeding to be accomplished at a rate programmed to match exactly the silicon removed by web growth.

Duncan, C. S.↗

Instrument Measures Airflow Friction Without Contact

Dual beam laser interferometer determines airflow friction against body by measuring time-varying thickness of wind sheared oil film. Measurements yield skin friction between film and airstream. Errors from prerun oil flow, tunnel starting transients, and initial surface waves therefore eliminated.

Monson, D. J.↗

Separation of time-averaged turbulence components by laser-induced fluorescence

A resonant Doppler velocimeter technique is introduced for time averaged gas flow turbulence fluctuation measurements. A monochrome laser beam is shone through a flow seeded with an atomic or molecular species that has an absorption frequency to which the laser is tuned. The resulting fluorescence is recorded by a detector, and the Doppler shift of the absorption frequency yields the velocity component of the flow in the direction of the beam. Static temperature and pressure data are available from the spectroscopic absoption line broadening. An analytical formulation of the laser-induced fluorescence intensity is defined and related to the velocity, temperature, and pressure. Comparison with data from a Na-seeded laminar supersonic jet demonstrates the accuracy of both the technique and model. Varying the pump laser frequency allows determination of the mean square velocity, temperature, and pressure fluctuations.

Cheng, S.↗

Optical Measurement Of Propfan Deflections

Optoelectronic system measures deflections of rotating propfan. In addition to 0.5-mW HeNe lasers, system includes Schottky-barrier photodetectors, neutral-density filters, signal amplifiers, output-signal-recording device, and digitizer. Laser beam passes through plane of rotation of propfan blades. Beam is one of three that measure displacements at different blade sections. Additional laser beam at bottom generates shaft-rotation timing signal.

Ramsey, John K.↗

Changes in "thermal lens" measure diffusivity

In an extension of "thermal lens" effect to new applications and better resolution, two laser beams combine to rapidly measure thermal diffusivity and other molecular dynamic properties. New double-beam technique handles very small samples unlike classical techniques for measuring diffusivity. It can be used for measurements on samples undergoing stress, making it applicable to data collection for structural engineering.

Gupta, A.↗

Single-shot measurements of pulse-front tilt in intense ps laser pulses and its effect on accelerated electron and ion beam characteristics (invited)

Here we report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗