Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

HPLC-Parallel accelerator and molecular mass spectrometry analysis of 14 C-labeled amino acids

Accelerator mass spectrometry (AMS) is the method of choice for quantitation of low amounts of 14 C-labeled biomolecules. Despite exquisite sensitivity, an important limitation of AMS is its inability to provide structural information about the analyte. This limitation is not critical when the labeled compounds are well-characterized prior to AMS analysis. However, analyte identity is important in other experiments where, for example, a compound is metabolized and the structures of its metabolites are not known. We previously described a moving wire interface that enables direct AMS measurement of liquid sample in the form of discrete drops or HPLC eluent without the need for individual fraction collection, termed liquid sample-AMS (LS-AMS). Here, we now report the coupling of LS-AMS with a molecular mass spectrometer, providing parallel accelerator and molecular mass spectrometry (PAMMS) detection of analytes separated by liquid chromatography. The repeatability of the method was examined by performing repeated injections of 14 C-labeled tryptophan, and relative standard deviations of the 14 C peak areas were ≤10.57% after applying a normalization factor based on a standard. Five 14 C-labeled amino acids were separated and detected to provide simultaneous quantitative AMS and structural MS data, and AMS results were compared with solid sample-AMS (SS-AMS) data using Bland-Altman plots. To demonstrate the utility of the workflow, yeast cells were grown in a medium with 14 C-labeled tryptophan. The cell extracts were analyzed by PAMMS, and 14 C was detected in tryptophan and its metabolite kynurenine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Knudsen Effusion Mass Spectrometry: Principles and Applications

Knudsen Effusion Mass Spectrometry (KEMS) is a well-established technique in physical chemistry. First, we discuss the basic principles of the technique. It is based on a small enclosure which sets up a condensed/vapor near equilibria. A small, well-defined orifice allows the vapor to be sampled a mass spectrometer. Although the number of groups utilizing this method has decrease significantly from its height in 1960s, we will show that it is still useful for many problems in physical chemistry, materials science, geology, and nuclear science. Specific examples illustrate its versatility: Measurement of the enthalpy of formation of HfO(g); measurement of activities in the Ti-Al-O and Ni-Al systems; measurement of activities in several rare earth silicate systems; measurement of vapor pressures above olivine; dating of minerals with K/Ar method; and determination of adsorption/desorption behavior on nuclear fission products on graphite. These are only a small sampling of the many applications of this versatile technique.

Mass spectrometry, thermodynamics, high temperatur↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science.

59 BASIC BIOLOGICAL SCIENCES↗

MS2Planner: improved fragmentation spectra coverage in untargeted mass spectrometry by iterative optimized data acquisition

Motivation: Untargeted mass spectrometry experiments enable the profiling of metabolites in complex biological samples. The collected fragmentation spectra are the metabolite’s fingerprints that are used for molecule identification and discovery. Two main mass spectrometry strategies exist for the collection of fragmentation spectra: data-dependent acquisition (DDA) and data-independent acquisition (DIA). In the DIA strategy, all the metabolites ions in predefined mass-to-charge ratio ranges are co-isolated and co-fragmented, resulting in multiplexed fragmentation spectra that are challenging to annotate. In contrast, in the DDA strategy, fragmentation spectra are dynamically and specifically collected for the most abundant ions observed, causing redundancy and sub-optimal fragmentation spectra collection. Yet, DDA results in less multiplexed fragmentation spectra that can be readily annotated. Results: We introduce the MS2Planner workflow, an Iterative Optimized Data Acquisition strategy that optimizes the number of high-quality fragmentation spectra over multiple experimental acquisitions using topological sorting. Our results showed that MS2Planner increases the annotation rate by 38.6% and is 62.5% more sensitive and 9.4% more specific compared to DDA. Availability and implementation MS2Planner code is available at https://github.com/mohimanilab/MS2Planner. The generation of the inclusion list from MS2Planner was performed with python scripts available at https://github.com/lfnothias/IODA_MS.

47 OTHER INSTRUMENTATION↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

Development and Application of DropletProbe Mass Spectrometry for Examining Biodistribution of Therapeutics

dropletProbe mass spectrometry is a novel technique for molecular characterization of surfaces. It can be used for rapid ex vivo analysis of therapeutics from thin animal tissue sections and has been shown to improve understanding of a drug’s absorption, distribution, metabolism and excretion (ADME) properties. Here, we describe the tissue distribution analysis of diclofenac from a dosed whole-body mouse thin tissue section using a dropletProbe mass spectrometry system.

Chen, Bingming↗

Thermodynamic Activity Measurements with Knudsen Cell Mass Spectrometry

Coupling the Knudsen effusion method with mass spectrometry has proven to be one of the most useful experimental techniques for studying the equilibrium between condensed phases and complex vapors. The Knudsen effusion method involves placing a condensed sample in a Knudsen cell, a small "enclosure", that is uniformly heated and held until equilibrium is attained between the condensed and vapor phases. The vapor is continuously sampled by effusion through a small orifice in the cell. A molecular beam is formed from the effusing vapor and directed into a mass spectrometer for identification and pressure measurement of the species in the vapor phase. Knudsen cell mass spectrometry (KCMS) has been used for nearly fifty years now and continues to be a leading technique for obtaining thermodynamic data. Indeed, much of the well-established vapor specie data in the JANAF tables has been obtained from this technique. This is due to the extreme versatility of the technique. All classes of materials can be studied and all constituents of the vapor phase can be measured over a wide range of pressures (approximately 10(exp -4) to 10(exp -11) bar) and temperatures (500-2800 K). The ability to selectively measure different vapor species makes KCMS a very powerful tool for the measurement of component activities in metallic and ceramic solutions. Today several groups are applying KCMS to measure thermodynamic functions in multicomponent metallic and ceramic systems. Thermodynamic functions, especially component activities, are extremely important in the development of CALPHAD (Calculation of Phase Diagrams) type thermodynamic descriptions. These descriptions, in turn, are useful for modeling materials processing and predicting reactions such as oxide formation and fiber/matrix interactions. The leading experimental methods for measuring activities are the Galvanic cell or electro-motive force (EMF) technique and the KCMS technique. Each has specific advantages, depending on material and conditions. The EMF technique is suitable for lower temperature measurements, provided a suitable cell can be constructed. KCMS is useful for higher temperature measurements in a system with volatile components. In this paper, we briefly review the KCMS technique and identify the major experimental issues that must be addressed for precise measurements. These issues include temperature measurements, cell material and cell design and absolute pressure calibration. The resolution of these issues are discussed together with some recent examples of measured thermodynamic data.

Copland, Evan H.↗

Picoliter droplet sample processing and deposition for mass spectrometry

Disclosed herein include systems, devices, and methods for droplet deposition for mass spectrometry. In some embodiments, a microfluidic device comprising wells is reversibly sealed to a mass spectrometry surface and used to deposit contents of droplets (e.g., enzymes and substrates), or products thereof, onto the mass spectrometry surface. The contents of droplets can be analyzed by laser desorption/ionization to, for example, identify a substrate of an enzyme or an enzyme capable of catalyzing a substrate to a product.

Ha, Noel↗

Detecting compounds in microfluidic droplets using mass spectrometry

Disclosed herein are devices and methods for detecting compounds in droplets using mass spectrometry. In some embodiments, the device comprises: a microfluidics-MS (microMS) device, wherein the microMS device comprises: a droplet-to-digital microfluidic device, wherein the droplet-to-digital microfluidic device comprises: a glass layer; an electrode layer comprising chrome electrodes etched onto one side of the glass layer; a dielectric layer configured for electrowetting; and a microfluidics layer comprising channels, pockets, and a droplet generator, for example a T-junction droplet generator, wherein the pockets are connected to the channels; and a mass spectrometry plate, wherein the mass spectrometry plate is reversibly sealed to the microfluidic device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved chemical studies via time-of-flight secondary ion mass spectrometry

A method of performing time-of-flight secondary ion mass spectrometry on a sample includes the step of directing a beam of primary ions to the sample, and stimulating the migration of ions within the sample while the beam of primary ions is directed at the sample. The stimulation of the ions is cycled between a stimulation state and a lower stimulation state. Secondary ions emitted from the sample by the beam of primary ions are collected in a time-of-flight mass spectrometer. Time-of-flight secondary ion mass spectrometry is then performed on the secondary ions. A system for performing time-of-flight secondary ion mass spectrometry on a sample is also disclosed.

Ievlev, Anton V.↗

Spatially Resolved Mass Spectrometry at the Single Cell: Recent Innovations in Proteomics and Metabolomics

Biological systems are composed of heterogeneous populations of cells that intercommunicate to form a functional living tissue. Biological function varies greatly across populations of cells, as each single cell has a unique transcriptome, proteome, and metabolome that translates to functional differences within single species and across kingdoms. Over the past decade, substantial advancements in our ability to characterize omic profiles on a single cell level have occurred, including in multiple spectroscopic and mass spectrometry (MS)-based techniques. Of these technologies, spatially resolved mass spectrometry approaches, including mass spectrometry imaging (MSI), have shown the most progress for single cell proteomics and metabolomics. For example, reporter-based methods using heavy metal tags have allowed for targeted MS investigation of the proteome at the subcellular level, and development of technologies such as laser ablation electrospray ionization mass spectrometry (LAESI-MS) now mean that dynamic metabolomics can be performed in situ. In this Perspective, we showcase advancements in single cell spatial metabolomics and proteomics over the past decade and highlight important aspects related to high-throughput screening, data analysis, and more which are vital to the success of achieving proteomic and metabolomic profiling at the single cell scale. Finally, using this broad literature summary, we provide a perspective on how the next decade may unfold in the area of single cell MS-based proteomics and metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Hydroxyl radical mediated damage of proteins in low oxygen solution investigated using X-ray footprinting mass spectrometry

In the method of X-ray footprinting mass spectrometry (XFMS), proteins at micromolar concentration in solution are irradiated with a broadband X-ray source, and the resulting hydroxyl radical modifications are characterized using liquid chromatography mass spectrometry to determine sites of solvent accessibility. These data are used to infer structural changes in proteins upon interaction with other proteins, folding, or ligand binding. XFMS is typically performed under aerobic conditions; dissolved molecular oxygen in solution is necessary in many, if not all, the hydroxyl radical modifications that are generally reported. In this study we investigated the result of X-ray induced modifications to three different proteins under aerobic versus low oxygen conditions, and correlated the extent of damage with dose calculations. We observed a concentration-dependent protecting effect at higher protein concentration for a given X-ray dose. For the typical doses used in XFMS experiments there was minimal X-ray induced aggregation and fragmentation, but for higher doses we observed formation of covalent higher molecular weight oligomers, as well as fragmentation, which was affected by the amount of dissolved oxygen in solution. The higher molecular weight products in the form of dimers, trimers, and tetramers were present in all sample preparations, and, upon X-ray irradiation, these oligomers became non-reducible as seen in SDS-PAGE. The results provide an important contribution to the large body of X-ray radiation damage literature in structural biology research, and will specifically help inform the future planning of XFMS, and well as X-ray crystallography and small-angle X-ray scattering experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗

Internal Fragments Generated by Electron Ionization Dissociation Enhance Protein Top-Down Mass Spectrometry

Top-down proteomics by mass spectrometry (MS) involves the mass measurement of an intact protein followed by subsequent activation of the protein to generate product ions. Electron-based fragmentation methods like electron capture dissociation and electron transfer dissociation are widely used for these types of analyses. Recently, electron ionization dissociation (EID), which utilizes higher energy electrons (>20 eV) has been suggested to be more efficient for top-down protein fragmentation compared to other electron-based dissociation methods. In this paper, we demonstrate that the use of EID enhances protein fragmentation and subsequent detection of protein fragments. Protein product ions can form by either single cleavage events, resulting in terminal fragments containing the C-terminus or N-terminus of the protein, or by multiple cleavage events to give rise to internal fragments that include neither the C-terminus nor the N-terminus of the protein. Conventionally, internal fragments have been disregarded, as reliable assignments of these fragments were limited. Here, we demonstrate that internal fragments generated by EID can account for ~20–40% of the mass spectral signals detected by top-down EID-MS experiments. By including internal fragments, the extent of the protein sequence that can be explained from a single tandem mass spectrum increases from ~50 to ~99% for 29 kDa carbonic anhydrase II and 8.6 kDa ubiquitin. When searching for internal fragments during data analysis, previously unassigned peaks can be readily and accurately assigned to confirm a given protein sequence and to enhance the utility of top-down protein sequencing experiments.

59 BASIC BIOLOGICAL SCIENCES↗