Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Manifold model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Improving Experimental Design through Uncertainty Analysis

In this paper, the development of a fission-gas collecting and physical-analysis-enabling instrument was proposed for small-volume determination. Analysis specifications require a design capable of accurately and repeatably determining volumes in the range of 0.07–2.5 mL. This system relies on a series of gas expansions originating from a cylinder with known internal volume. The combined gas law is used to derive the unknown volumes from these expansions. Initial system designs included one of two known volumes, 11.85 ± 0.34 mL and 5.807 ± 0.078 mL, with a manifold volume of 32 mL. Results obtained from modeling this system’s operation showed that 0.07 mL can be determined with a relative expanded uncertainty greater than 300% (k = 2) for a single replicate, which was unacceptable for the proposed experimental design. Initial modeling showed that the volume connecting the known volume and rodlet, i.e., the manifold volume, and the sensitivity of the pressure sensor were key contributors to the expanded uncertainty of the measured rodlet volume. The system’s design limited the available options for pressure sensors, so emphasis was placed on the design of the manifold volume. The final system design reduced the manifold volume to 17 mL. These changes in design, combined with replicate analysis, were able to reduce the relative expanded uncertainty by ±12% (k = 2) for the 0.07 mL volume.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Iron-sulfur clusters: the road to room temperature

Abstract Iron-sulfur proteins perform a wide variety of reactions central to the metabolisms of all living organisms. Foundational to their reaction chemistry are the rich electronic structures of their constituent Fe-S clusters, which differ in important ways from the active sites of mononuclear Fe enzymes. In this perspective, we summarize the essential electronic structure features that make Fe-S clusters unique, and point to the need for studies aimed at understanding the electronic basis for their reactivity under physiological conditions. Specifically, at ambient temperature, both the ground state and a large number of excited states are thermally populated, and thus a complete understanding of Fe-S cluster reactivity must take into account the properties, energies, and reactivity patterns of these excited states. We highlight prior research toward characterizing the low-energy excited states of Fe-S clusters that has established what is now a consensus model of these excited state manifolds and the bonding interactions that give rise to them. In particular, we discuss the low-energy alternate spin states and valence electron configurations that occur in Fe-S clusters of varying nuclearities, and finally suggest that there may be unrecognized functional roles for these states. Graphical abstract

Skeel, Brighton A. (ORCID:000000018458088X)↗

Data-driven models of nonautonomous systems

Nonautonomous dynamical systems are characterized by time-dependent inputs, which complicates the discovery of predictive models describing the spatiotemporal evolution of the state variables of quantities of interest from their temporal snapshots. When dynamic mode decomposition (DMD) is used to infer a linear model, this difficulty manifests itself in the need to approximate the time-dependent Koopman operators. Our approach is to approximate the original nonautonomous system with a modified system derived via a local parameterization of the time-dependent inputs. The modified system comprises a sequence of local parametric systems, which are subsequently approximated by a parametric surrogate model using the DRIPS (dimension reduction and interpolation in parameter space) framework. The offline step of DRIPS relies on DMD to build a linear surrogate model, endowed with reduced-order bases for the observables mapped from training data. The online step interpolates on suitable manifolds to construct a sequence of iterative parametric surrogate models; the target/test parameter points on these manifolds are specified by a local parameterization of the test time-dependent inputs. Here, we use numerical experimentation to demonstrate the robustness of our method and compare its performance with that of deep neural networks.

97 MATHEMATICS AND COMPUTING↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

An approximate inertial manifold (AIM) based closure for turbulent flows

A closure model for turbulent flows is developed based on a dynamical system theory. An appropriately discretized formulation of the governing equations is considered for this process. The key ingredient is an approximation of the system’s attractor, where all the trajectories in phase space are confined. This approximate inertial manifold based approach provides a path to track trajectories of the system in a lower-dimensional subspace. Unlike conventional coarse-graining approaches, the turbulent field is decomposed into resolved and unresolved dynamics using the properties of the governing equations. The novelty of the approach relies on the reconstruction of the unresolved field constrained by the governing equations. A posteriori tests for homogeneous isotropic turbulence and the Kuramoto–Sivashinsky equation show promising results for considerable dimension reduction with strong convergence properties. The proposed model outperforms the dynamic Smagorinsky model, and the computational overhead is competitive with similar approaches.

97 MATHEMATICS AND COMPUTING↗

Time-series forecasting using manifold learning, radial basis function interpolation, and geometric harmonics

We address a three-tier numerical framework based on nonlinear manifold learning for the forecasting of high-dimensional time series, relaxing the “curse of dimensionality” related to the training phase of surrogate/machine learning models. At the first step, we embed the high-dimensional time series into a reduced low-dimensional space using nonlinear manifold learning (local linear embedding and parsimonious diffusion maps). Then, we construct reduced-order surrogate models on the manifold (here, for our illustrations, we used multivariate autoregressive and Gaussian process regression models) to forecast the embedded dynamics. Finally, we solve the pre-image problem, thus lifting the embedded time series back to the original high-dimensional space using radial basis function interpolation and geometric harmonics. The proposed numerical data-driven scheme can also be applied as a reduced-order model procedure for the numerical solution/propagation of the (transient) dynamics of partial differential equations (PDEs). In conclusion, we assess the performance of the proposed scheme via three different families of problems: (a) the forecasting of synthetic time series generated by three simplistic linear and weakly nonlinear stochastic models resembling electroencephalography signals, (b) the prediction/propagation of the solution profiles of a linear parabolic PDE and the Brusselator model (a set of two nonlinear parabolic PDEs), and (c) the forecasting of a real-world data set containing daily time series of ten key foreign exchange rates spanning the time period 3 September 2001–29 October 2020.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Flow Models for SSME Flowfield Characterization

Full scale flow models with extensive instrumentation were designed and manufactured to provide data necessary for flow field characterization in rocket engines of the Space Shuttle Main Engine (SSME) type. These models include accurate flow path geometries from the pre-burner outlet through the throat of the main combustion chamber. The turbines are simulated with static models designed to provide the correct pressure drop and swirl for specific power levels. The correct turbopump-hot gas manifold interfaces were designed into the flow models to permit parametric/integration studies for new turbine designs. These experimental flow models provide a vehicle for understanding the fluid dynamics associated with specific engine issues and also fill the more general need for establishing a more detailed fluid dynamic base to support development and verification of advanced math models.

Abel, L. C.↗

Manifest: A computer program for 2-D flow modeling in Stirling machines

A computer program named Manifest is discussed. Manifest is a program one might want to use to model the fluid dynamics in the manifolds commonly found between the heat exchangers and regenerators of Stirling machines; but not just in the manifolds - in the regenerators as well. And in all sorts of other places too, such as: in heaters or coolers, or perhaps even in cylinder spaces. There are probably nonStirling uses for Manifest also. In broad strokes, Manifest will: (1) model oscillating internal compressible laminar fluid flow in a wide range of two-dimensional regions, either filled with porous materials or empty; (2) present a graphics-based user-friendly interface, allowing easy selection and modification of region shape and boundary condition specification; (3) run on a personal computer, or optionally (in the case of its number-crunching module) on a supercomputer; and (4) allow interactive examination of the solution output so the user can view vector plots of flow velocity, contour plots of pressure and temperature at various locations and tabulate energy-related integrals of interest.

Gedeon, David↗

Numerical analysis of flow in the hot gas manifold of the Space Shuttle main engine

This paper presents a numerical model and results of analyses carried out to characterize the flow through the two duct configuration of the Hot Gas Manifold of the Space Shuttle Main Engine. Three dimensional computations have been performed for a half-scale air test model using a nonorthogonal body-fitted coordinate system. The calculation domain is extended from the inlet of the turnaround duct to the exit of the transfer duct. Three test cases, one for laminar flow and two for turbulent flow, have been considered. For turbulent flows, constant eddy viscosity and the k-epsilon model of turbulence were employed. As expected, laminar flow calculation predicts much larger pressure drop than turbulent flow cases. The turbulent flow results are in good agreement with the available flow-visualization data. This study and experimental data indicate that the two-transfer duct design will significantly improve the flow distribution in the Hot Gas Manifold and thereby enhance the overall performance of the SSME.

Owens, S. F.↗

Probabilistic partition of unity networks for high–dimensional regression problems

We explore the probabilistic partition of unity network (PPOU-Net) model in the context of high-dimensional regression problems and propose a general framework focusing on adaptive dimensionality reduction. With the proposed framework, the target function is approximated by a mixture of experts model on a low-dimensional manifold, where each cluster is associated with a fixed-degree polynomial. We present a training strategy that leverages the expectation maximization (EM) algorithm. During the training, we alternate between (i) applying gradient descent to update the DNN coefficients; and (ii) using closed-form formulae derived from the EM algorithm to update the mixture of experts model parameters. Under the probabilistic formulation, step (ii) admits the form of embarrassingly paralleliazable weighted least-squares solves. The PPOU-Nets consistently outperform the baseline fully-connected neural networks of comparable sizes in numerical experiments of various data dimensions. Here, we also explore the proposed model in applications of quantum computing, where the PPOU-Nets act as surrogate models for cost landscapes associated with variational quantum circuits.

97 MATHEMATICS AND COMPUTING↗

Manifold Insulation for Solar Collectors

Results of computer analysis of effects of various manifold insulation detailed in 23-page report show that if fluid is distributed to and gathered from array of solar collectors by external rather than internal manifold, effectiveness of manifold insulation has major influence on efficiency. Report describes required input data and presents equations that govern computer model. Provides graphs comparing collector efficiencies for representative manifold sizes and insulations.

Source record↗

Investigation of the transient fuel preburner manifold and combustor

A computational fluid dynamics (CFD) model with finite rate reactions, FDNS, was developed to study the start transient of the Space Shuttle Main Engine (SSME) fuel preburner (FPB). FDNS is a time accurate, pressure based CFD code. An upwind scheme was employed for spatial discretization. The upwind scheme was based on second and fourth order central differencing with adaptive artificial dissipation. A state of the art two-equation k-epsilon (T) turbulence model was employed for the turbulence calculation. A Pade' Rational Solution (PARASOL) chemistry algorithm was coupled with the point implicit procedure. FDNS was benchmarked with three well documented experiments: a confined swirling coaxial jet, a non-reactive ramjet dump combustor, and a reactive ramjet dump combustor. Excellent comparisons were obtained for the benchmark cases. The code was then used to study the start transient of an axisymmetric SSME fuel preburner. Predicted transient operation of the preburner agrees well with experiment. Furthermore, it was also found that an appreciable amount of unburned oxygen entered the turbine stages.

Wang, Ten-See↗

Slow manifold reduction for plasma science

The classical Chapman–Enskog procedure admits a substantial geometrical generalization known as slow manifold reduction. This generalization provides a paradigm for deriving and understanding most reduced models in plasma physics that are based on controlled approximations applied to problems with multiple timescales. In this Review we develop the theory of slow manifold reduction with a plasma physics audience in mind. In particular we illustrate (a) how the slow manifold concept may be used to understand breakdown of a reduced model over sufficiently-long time intervals, and (b) how a discrete-time analogue of slow manifold theory provides a useful framework for developing implicit integrators for temporally-stiff plasma models. For readers with more advanced mathematical training we also use slow manifold reduction to explain the phenomenon of inheritance of Hamiltonian structure in dissipation-free reduced plasma models. Various facets of the theory are illustrated in the context of the Abraham–Lorentz model of a single charged particle experiencing its own radiation drag. As a culminating example we derive the slow manifold underlying kinetic quasineutral plasma dynamics up to first-order in perturbation theory. This first-order result incorporates several physical effects associated with small deviations from exact charge neutrality that lead to slow drift away from predictions based on the leading-order approximation n e = Z i n i .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Manifolds for Improved Solid Oxide Electrolyzer Performance

An investigation was conducted to see if additive manufacturing could be used to fabricate more efficient manifold designs for improved flow, reduced stresses, and decreased number of joints to be sealed for a solid oxide electrolyzer used to convert carbon dioxide to oxygen. Computational flow and mechanical modeling were conducted on a NASA Glenn Research Center patented cell and stack design with the potential to achieve a 3-4 times mass reduction. Various manifold designs were modeled, and two were downselected to be fabricated and tested. Some benefit was seen in a baffled manifold design, which directed incoming flow more effectively into the flow channels, compared to the original design, where the flow spent more time within the manifold itself. Flow measurements indicated some non-uniformity of flow across the channels at higher flow rates, which were not predicted by the model. Some possible explanations for the differences are discussed.

Linne, Diane L.↗