IDENTIFICATION OF POTENTIAL SUPERCONDUCTOR QUENCH PRECURSORS USING FREQUENCY DOMAIN FEATURE ANALYSIS

Superconducting magnets are important pieces of technology in the world of particle accelerators, allowing researchers to study atomic and subatomic phenomena, among other things. In some instances, superconductors can lose this non-resistive property in a phenomenon known as quenching, which can cause damage to the magnets. This potential danger prompts the introduction of systems to predict when a quench is imminent; one such implementation is through the use of acoustic sensors that detect vibrations within the magnet. Within these acoustic sensor signals, significantly above-noise disturbances (referred to as ”events”) can be identified. Our research applies the statistical framework of a permutation test to features calculated from the power spectral density (PSD) to distinguish between events far from the quench at the end of the signal to events at the start of the signal. We found that dividing the PSD into frequency bands produced a feature capable of distinguishing between events early in the signal and late in the signal leading up the quench, providing a promising starting place for future quench prediction systems.

Roehrig, Benjamin [Northern Illinois U.]↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

Novel 3D Force Sensors for a Cost-Effective 3D Force Plate for Biomechanical Analysis

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950–0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.

42 ENGINEERING↗

Fiber-optic diagnostic system for future accelerator magnets

The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.

43 PARTICLE ACCELERATORS↗

Predicting the formation of fractionally doped perovskite oxides by a function-confined machine learning method

Abstract Fractionally doped perovskites oxides (FDPOs) have demonstrated ubiquitous applications such as energy conversion, storage and harvesting, catalysis, sensor, superconductor, ferroelectric, piezoelectric, magnetic, and luminescence. Hence, an accurate, cost-effective, and easy-to-use methodology to discover new compositions is much needed. Here, we developed a function-confined machine learning methodology to discover new FDPOs with high prediction accuracy from limited experimental data. By focusing on a specific application, namely solar thermochemical hydrogen production, we collected 632 training data and defined 21 desirable features. Our gradient boosting classifier model achieved a high prediction accuracy of 95.4% and a high F1 score of 0.921. Furthermore, when verified on additional 36 experimental data from existing literature, the model showed a prediction accuracy of 94.4%. With the help of this machine learning approach, we identified and synthesized 11 new FDPO compositions, 7 of which are relevant for solar thermochemical hydrogen production. We believe this confined machine learning methodology can be used to discover, from limited data, FDPOs with other specific application purposes.

08 HYDROGEN↗

Patterning of magneto-optical nanomaterials

Patterning of colloidal particles in precisely organized architectures has attracted intense research interest for decades. This is due to their potential applications in flexible electronics, magnetic and optical devices, sensors, biotechnology, communications, etc. However, creation of mesoscale assemblies at commercial scales have received less attention. The mesoscale systems reside between the micro- and macroscopic scales, with length dimensions from ≈ 100 µm to 5 mm. By leveraging decades of experimental and theoretical research in nanomaterial fields, we were able to precisely create and control the placement of nanoscale materials, allowing us to create mesoscale materials. We developed a versatile and automatic mesoscale patterning technology (via SEM-FIB and 3D printing) that provides precise and consistent control and special arrangement of functional nanomaterials. The versatility of the strategy is demonstrated by patterning nanoparticles with different dimensions, shapes and compositions, tethered with various functionalities and subjected to different external stimuli.

42 ENGINEERING↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Acoustic Sensing Fiber Coupled with Highly Magnetostrictive Ribbon for Small-Scale Magnetic-Field Detection

Fiber-optic sensing has shown promising development for use in detecting magnetic fields for downhole and biomedical applications. Coupling existing fiber-based strain sensors with highly magnetostrictive materials allows for a new method of magnetic characterization capable of distributed and high-sensitivity field measurements. This study investigates the strain response of the highly magnetostrictive alloys Metglas® 2605SC and Vitrovac® 7600 T70 using Fiber Bragg Grating (FBG) acoustic sensors and an applied AC magnetic field. Sentek Instrument’s picoDAS interrogated the distributed FBG sensors set atop a ribbon of magnetostrictive material, and the corresponding strain response transferred to the fiber was analyzed. Using the Vitrovac® ribbon, a minimal detectable field amplitude of 60 nT was achieved. Using Metglas®, an even better sensitivity was demonstrated, where detected field amplitudes as low as 3 nT were measured via the strain response imparted to the FBG sensor. Distributed FBG sensors are readily available commercially, easily integrated into existing interrogation systems, and require no bonding to the magnetostrictive material for field detection. The simple sensor configuration with nanotesla-level sensitivity lends itself as a promising means of magnetic characterization and demonstrates the potential of fiber-optic acoustic sensors for distributed measurements.

Dejneka, Zach (ORCID:0000000179415708)↗

Subterahertz Spin Relaxation Dynamics of Boron-Vacancy Centers in Hexagonal Boron Nitride

Quantum sensors based on spin defects have become powerful tools for detecting faint magnetic signals, yet their operation remains confined to low magnetic fields and gigahertz frequencies. Extending such sensors into high-field (>0.3 T) and subterahertz regimes would enable quantum metrology across a wide range of electromagnetic phenomena and scientific applications, but has proven challenging. Here, we demonstrate that negatively charged boron vacancies ($V^−_B$) in hexagonal boron nitride can function as relaxation-based quantum sensors operating up to 0.2 terahertz and 7 T fields. Their uniform spin-orientation and persistent spin-contrast at high fields enable measurement of intrinsic spin relaxation across unexplored field regimes. We reveal a crossover in relaxation behavior, initially decreasing at low fields before rising at higher fields, consistent with the emergence of single-phonon-induced resonant noise at subterahertz frequencies. These results establish $V^−_B$ centers as a versatile platform for quantum sensing in the subterahertz, high-field regime.

boron-vacancies↗

Design and development of the magnetic diagnostic systems for the first operational phase of the SMART tokamak

A set of magnetic diagnostics has been designed, manufactured, and calibrated for the first operational phase of the small aspect ratio tokamak. The sensor suite comprises of Rogowski coils; 2D magnetic probes; and poloidal, saddle, and diamagnetic flux loops. Here, a set of continuous Rogowski coils has been manufactured for the measurement of plasma current and induced eddy currents in conductive elements. A set of flux loops and magnetic probes will be used as input for the reconstruction of the magnetohydrodynamic equilibrium. The quantity and position of these sensors have been verified to be sufficient with synthetic equilibrium reconstructions using the equilibrium fitting code and baseline scenarios computed with the Fiesta code. These sensors will also be used as input for the real-time control system, and magnetic probes will be used for the detection of plasma instabilities. The calibration procedure for the magnetic probes is described, and the results are shown. The signal conditioning and data acquisition systems are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High field magnetometry with hyperpolarized nuclear spins

Abstract Quantum sensors have attracted broad interest in the quest towards sub-micronscale NMR spectroscopy. Such sensors predominantly operate at low magnetic fields. Instead, however, for high resolution spectroscopy, the high-field regime is naturally advantageous because it allows high absolute chemical shift discrimination. Here we demonstrate a high-field spin magnetometer constructed from an ensemble of hyperpolarized 13 C nuclear spins in diamond. They are initialized by Nitrogen Vacancy (NV) centers and protected along a transverse Bloch sphere axis for minute-long periods. When exposed to a time-varying (AC) magnetic field, they undergo secondary precessions that carry an imprint of its frequency and amplitude. For quantum sensing at 7T, we demonstrate detection bandwidth up to 7 kHz, a spectral resolution < 100mHz, and single-shot sensitivity of 410pT $$/\sqrt{{{{{{{{\rm{Hz}}}}}}}}}$$ / Hz . This work anticipates opportunities for microscale NMR chemical sensors constructed from hyperpolarized nanodiamonds and suggests applications of dynamic nuclear polarization (DNP) in quantum sensing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC↗

Combinatorial sputter deposition of ultrathick Au-Bi alloy films

We report gold-bismuth alloys are of interest as catalysts and catalytic sensing systems, electrochemical sensors, superconductors, and hohlraums for magnetically assisted inertial confinement fusion implosions. Radiation-hydrodynamics simulations with the Lasnex code of laser-driven hohlraums predict higher x-ray drive from Au-Bi alloys compared with cases of Au-Ta or pure Au and Bi hohlraums. Here, we use direct current magnetron sputtering in Ar gas, with co-sputtering from two elemental targets, to deposit Au-Bi alloys with Bi content of 9–77 at.% and thicknesses up to ~20 µm. Films are characterized by a combination of x-ray diffraction, Rutherford backscattering, scanning electron microscopy, substrate-curvature-based residual stress, and electronic transport measurements. Experiments are complemented by Monte Carlo simulations of ballistic sputtering and gas phase transport of depositing species and Ar gas atoms. Results show that all films are polycrystalline, with three distinct compositional regimes dominated by Au, Au 2 Bi, and Bi crystallographic phases. A metallic behavior of the temperature dependence of electrical resistivity is observed for all the films. Films with Bi content above ~30 at.% exhibit porosity, which is tolerable to hohlraum x-ray drive based on Lasnex simulations.