Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High peak power (≥10 mW) quantum cascade superluminescent emitter

We report room temperature and milliwatt range mid-infrared superluminescent emission at 5 μm from Quantum Cascade (QC) devices. To achieve high power superluminescence, we utilize an ultrastrong coupling QC laser design, and employ a cavity formed by the combination of a 17° tilted cleaved facet and a wet etched rounded and sloped facet to introduce additional mirror loss. For pulsed mode operation, a 8 mm long and 15 μm wide device achieves ∼1.3 mW peak power at 300 K and a 25 μm wide device with Si{sub 3}N{sub 4} anti-reflection coated rounded facet achieves ∼10.2 mW peak optical output power at 250 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research on a 170 GHz, 2 MW coaxial cavity gyrotron with inner-outer corrugation

In this paper, a coaxial cavity gyrotron with inner-outer corrugation is researched. The electron kineto-equations and the first order transmission line equations of the gyrotron are derived from Lorentz force equation and the transmission line theory, respectively. And then, a 2 MW, 170 GHz coaxial cavity gyrotron with inner-outer corrugation is designed. By means of numerical calculation, the beam-wave interaction of the coaxial cavity gyrotron with inner-outer corrugation is investigated. Results show that the efficient and the outpower of the gyrotron are 42.3% and 2.38 MW, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tapered erbium-doped fibre laser system delivering 10 MW of peak power

We consider a fibre laser system generating ∼10-μJ, ∼500-fs pulses with a peak power of ∼10 MW at a repetition rate of 100 kHz and emission wavelength of 1.56 μm. The system is based on a master oscillator – power amplifier configuration. The amplifier ensures chirped-pulse amplification. The pulses are then compressed by a dispersive grating compressor. The output amplifier stage is based on a specially designed tapered large mode area erbium-doped fibre for suppressing nonlinear effects. The experimental data agree with numerical simulation results for the stretcher, amplifier and compressor. The stretcher and amplifier have been simulated using a generalised nonlinear Schrödinger equation. In addition, numerical simulation results suggest that optimising the stretcher and compressor will potentially allow the peak power of the system to be scaled up to ∼30 MW. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

A MW scale charging architecture for supporting extreme fast charging of heavy-duty electric vehicles

Extreme fast charging of electric vehicles technologies is coming. Heavy duty electric vehicles (HD-EVs) are in development and are expected to have multipliers bigger in battery capacity compared to the light duty counterparts. To meet short charging times, MW charging will be necessary. This paper presents a MW scale extreme DC fast charger with a communication and control architecture for HD-EVs. The system is validated in a controller hardware in the loop platform.

Starke, Michael↗

Improving Resiliency in Planning MW-Scale Medium and Heavy Duty EV Charging Stations Considering TSCOTS Optimization

Electrification of heavy-duty (HD) vehicles marks an important milestone and technical challenge in the electric vehicle (EV) industry and the public grid. However, implementing EV charging at this scale will necessitate that traditional truck stops be updated with EV charging infrastructure that could represent 10's of MW in electricity consumption. Furthermore, as the transportation sector is represented as critical infrastructure, supporting resiliency considerations in EV charging infrastructure will be critical. This paper proposes an optimization-based approach for optimally designing a MW-scale microgrid charging network. This approach transforms conventional designed truck stops into a reliable HDEV charging stations capable of overnight slow charging and 30-minute to 1 hour fast charging. Using a mixed-integer linear program formulation blending capacity planning and reliability constraints, an optimal network configuration can be solved for a proposed EV charging station that includes photovoltaic and battery energy storage capabilities.

Ponce, Moises [University of Tennessee, Knoxville ↗

An Operationally Integrated Approach to the SNS 2.8 MW Power Upgrade

The SNS accelerator consist of a 1 GeV H⁻ linac and an accumulator ring producing a 1.4 MW pulsed proton beam which drives a spallation neutron source. The Proton Power Upgrade project will double the power capability from 1.4 to 2.8 MW by increasing the linac energy 30% and the beam current about 50%. Equipment upgrades include new superconducting RF cryomodules and supporting RF equipment, upgraded ring equipment, and upgraded high power target systems. An important aspect of the upgrade is a gradual power ramp-up starting in 2022 in which new equipment is installed during maintenance outages as it arrives.

Galambos, John D↗

Dynamometer Testing of Samsung 2.5MW Drivetrain: Cooperative Research and Development Final Report, CRADA Number CRD-08-311

SHI's prototype 2.5 MW wind turbine drivetrain was tested at the NWTC 2.5 MW dynamometer test facility over the course of 4 months between December 2009 and March 2010. This successful testing campaign allowed SHI to validate performance, safety, control tuning, and reliability in a controlled environment before moving to full-scale testing and subsequent introduction of a commercial product intothe American market.

17 WIND ENERGY↗

Initial operating experience of the 12-MW La Ola photovoltaic system.

The 1.2-MW La Ola photovoltaic (PV) power plant in Lanai, Hawaii, has been in operation since December 2009. The host system is a small island microgrid with peak load of 5 MW. Simulations conducted as part of the interconnection study concluded that unmitigated PV output ramps had the potential to negatively affect system frequency. Based on that study, the PV system was initially allowed to operate with output power limited to 50% of nameplate to reduce the potential for frequency instability due to PV variability. Based on the analysis of historical voltage, frequency, and power output data at 50% output level, the PV system has not significantly affected grid performance. However, it should be noted that the impact of PV variability on active and reactive power output of the nearby diesel generators was not evaluated. In summer 2011, an energy storage system was installed to counteract high ramp rates and allow the PV system to operate at rated output. The energy storage system was not fully operational at the time this report was written; therefore, analysis results do not address system performance with the battery system in place.

25 ENERGY STORAGE↗

20 MW Flywheel frequency regulation plant

Hazle designed, built, commissioned, and operates a utility-scale 20 MW flywheel energy storage plant in Hazle Township, Pennsylvania (the Hazle Facility) using flywheel technology developed by its affiliate, Beacon Power, LLC (Beacon Power). The Hazle Facility provides frequency regulation services to the regional transmission organization, PJM Interconnection, LLC (PJM), through its participation in PJM’s Regulation Market (a market-based system for the purchase and sale of the Regulation ancillary service). The zero emission Hazle Facility is designed for a 20 year-life over which it is capable of performing at least 100,000 full depth of discharge cycles. To achieve its 20 MW capacity, the Hazle Facility is comprised of two hundred of Beacon Power’s 100 kilowatt (kW)/25 kilowatt/hour (kWh) flywheels connected in parallel. The Hazle Facility can fully respond to a signal from PJM in less than 2 seconds. The Hazle facility was constructed in an economic development zone designated by the Commonwealth of Pennsylvania and its construction relied on local contractors and labor for completion.

25 ENERGY STORAGE↗

RCS for Multi-MW Facility at Fermilab [PowerPoint]

DUNE/LBNF is an international multi-decadal physics program for leading-edge neutrino science and proton decay study. The DUNE Interim Design Report calls the completion of PIP-II by 2026 and an upgrade to 2.4 MW beam power at 120 GeV by 2032. We argue a new rapid-cycling synchrotron (RCS) will enable the proton facility to achieve 2.4 MW beam power and set the stage for further upgrades to facility power. We discuss the constraints on RCS design and the implications for other parts of the accelerator facility.

43 PARTICLE ACCELERATORS↗

IEA Wind TCP Task 55: The IEA Wind 740-10-MW Reference Offshore Wind Plants

This report describes the first version of the regular and irregular IEA-Wind 740-10MW Reference Offshore Wind Plants (v0.1). The two plants have been developed within the second work package of IEA Wind Task 37 on Wind Energy Systems Engineering: Integrated RD&D. The plants aim at acting as reference for future research projects on wind energy, representing modern offshore wind plants. The designs are based on the Borssele III and IV offshore wind plant projects. The associated wind resource, allotted territory, and bathymetry measurements are used to define the site characteristics. 74 IEA 10-MW Reference Wind Turbines are arranged in two suggested layouts that are optimized for maximum annual energy production: one regular grid layout, one irregular layout. These reference wind plants have been described using the WindIO ontology and have been made available through an open-source repository on GitHub.

17 WIND ENERGY↗

Risk Analysis of a 100 MW Hydrogen Generation Facility near a Nuclear Power Plant

Nuclear power plants (NPPs) are considering flexible plant operations to take advantage of excess thermal and electrical energy. One option for NPPs is to pursue hydrogen production through high temperature electrolysis as an alternate revenue stream to remain economically viable. The intent of this study is to investigate the risk of a 100 MW hydrogen production facility in close proximity to an NPP. Previous analyses have evaluated preliminary designs of a hydrogen production facility in a conservative manner to determine if it is feasible to co-locate the facility within 1 km of an NPP. This analysis specifically evaluates the risk components of a 100 MW hydrogen production facility design, including the likelihood of a leak within the system and the associated consequence to critical NPP targets. This analysis shows that although the likelihood of a leak in an HTEF is not negligible, the consequence to critical NPP targets is not expected to lead to a failure given adequate distance from the plant.

08 HYDROGEN↗

COMSOL Results for the Nominal Steady-State Operation of the Proposed 95-MW LEU Silicide Core for HFIR Conversion

Engineering design studies are being performed to determine the feasibility of converting the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel at Oak Ridge National Laboratory. This activity is sponsored by the Office of Reactor Conversion and Uranium Supply (ORCUS) under the auspices of the US Department of Energy National Nuclear Security Administration’s Office of Material Management and Minimization. HFIR is a very high flux, pressurized, light water–cooled and moderated, flux trap–type research reactor with a core made of involute shaped U 3 O 8 /Al cermet fuel plates and coolant channels. HFIR currently operates at a thermal power of 85 MW and supports key national and international missions in neutron scattering, isotope production, materials/fuels irradiation, neutron activation analysis, gamma irradiation, and neutrino research. Advanced multiphysics computational fluid dynamics models have been developed in the COMSOL Multiphysics software to simulate the steady-state operating conditions for the proposed low-and high-density LEU U 3 Si 2 -Al (uranium silicide dispersion) fuel designs. The COMSOL models for HFIR inner and outer fuel element models incorporate various essential inputs and physics such as spatially dependent nuclear heat deposition, multilayer heat conduction, conjugate heat transfer, turbulent flows (using Reynolds-averaged Navier Stokes turbulence models), structural mechanics (thermal–structural interactions and fuel swelling), and oxide layer build-up. This report presents the best-estimate thermal hydraulics results for the low- and high-density optimized silicide LEU core designs at 95 MW steady-state nominal operation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Michigan

The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Michigan. We forecast the cumulative economic benefits from 1000 MW of development in Michigan to be $1.3 billion, annual CO2 reductions are estimated at 2.9 million tons, and annual water savings are 1,542 million gallons.

17 WIND ENERGY↗

Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Arkansas (Fact Sheet)

The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Arkansas. We forecast the cumulative economic benefits from 1000 MW of development in Arkansas to be $1.15 billion, annual CO2 reductions are estimated at 2.7 million tons, and annual water savings are 1,507 million gallons.

17 WIND ENERGY↗

Economic Benefits, Carbon Dioxide (CO2) Emissions Reductions, and Water Conservation Benefits from 1000 Megawatts (MW) of New Wind Power in Ohio (Fact Sheet)

The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Ohio. We forecast the cumulative economic benefits from 1000 MW of development in Ohio to be $1.3 billion, annual CO2 reductions are estimated at 2.5 million tons, and annual water savings are 1,343 million gallons.

17 WIND ENERGY↗

Economic Benefits, Carbon Dioxide (CO2) Emissions Reduction, and Water Conservation Benefits from 1,000 Megawatts (MW) of New Wind Power in Georgia (Fact Sheet)

The U.S. Department of Energy's Wind Powering America Program is committed to educating state-level policy makers and other stakeholders about the economic, CO2 emissions, and water conservation impacts of wind power. This analysis highlights the expected impacts of 1000 MW of wind power in Georgia. We forecast the cumulative economic benefits from 1000 MW of development in Georgia to be $2.1 billion, annual CO2 reductions are estimated at 3.0 million tons, and annual water savings are 1,628 million gallons.

17 WIND ENERGY↗