Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MINIATURIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Miniature pulsed magnet system for synchrotron x-ray measurements

We have developed a versatile experimental apparatus for synchrotron x-ray measurements in pulsed high magnetic fields. The apparatus consists of a double cryostat incorporating a liquid nitrogen bath to cool the miniature pulsed coil and an independent helium flow cryostat allowing sample temperatures from 4 up to 250 K. The high duty cycle miniature pulsed coils can generate up to 38 T. During experiments at 30 T a repetition rate of 6 pulses/min was routinely reached. Using a 4 kJ power supply, the pulse duration was between 500 {mu}s and 1 ms. The setup was used for nuclear forward scattering measurements on {sup 57}Fe up to 25 T on the ESRF beamline ID18. In another experiment, x-ray magnetic circular dichroism was measured up to 30 T on the ESRF energy dispersive beamline ID24.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass- and energy-analyses of ions from plasma by means of a miniature Thomson spectrometer

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Accuracy of velocity correction for impact of a laser-accelerated miniature flyer with lithium fluoride shock-compressed along the [100] axis

We performed miniature flyer impact experiments to investigate the relationship between the apparent (u{sub a}) and actual (u{sub A}) particle velocities measured by a velocity interferometer in single-crystal lithium fluoride (LiF) that was shock-compressed along the [100] axis. The miniature flyer was accelerated to velocities in the range 652.5-1937.6 m/s by a tabletop pulsed laser. An empirical relationship of u{sub a}= (1.2749 {+-} 0.0102)u{sub A} was obtained. The obtained relationship agreed well with the results of a previous study within the experimental errors and its uncertainty was less than {+-}1%. This result indicates that the present experimental technique is effective for measuring the relationship between u{sub a} and u{sub A} of shocked transparent materials with a comparable accuracy to conventional methods.

36 MATERIALS SCIENCE↗

A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction

We describe the design, construction, calibration, and two different applications of a miniature capacitance dilatometer. The device is suitable for thermal expansion and magnetostriction measurements from 300 K down to about 25 mK, with a resolution of 0.02 A at low temperatures. The main body of the dilatometer is fabricated from a single block of a Be-Cu alloy by electrical discharge milling. This creates an extremely compact high-resolution measuring cell. We have successfully tested and operated dilatometers of this new type with the commonly used physical property measurement system by quantum design, as well as with several other cryogenic refrigeration systems down to 25 mK and in magnetic fields up to 20 T. Here, the capacitance is measured with a commercially available capacitance bridge. Using a piezoelectric rotator from Attocube Systems, the cell can be rotated at T= 25 mK inside of an inner vacuum chamber of 40 mm diameter. The miniaturized design for the one-axis rotation setup allows a rotation of 360 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital miniature x-ray tube with a high-density triode carbon nanotube field emitter

We have fabricated a digital miniature x-ray tube (6 mm in diameter and 32 mm in length) with a high-density triode carbon nanotube (CNT) field emitter for special x-ray applications. The triode CNT emitter was densely formed within a diameter of below 4 mm with the focusing-functional gate. The brazing process enables us to obtain and maintain a desired vacuum level for the reliable electron emission from the CNT emitters after the vacuum packaging. The miniature x-ray tube exhibited a stable and reliable operation over 250 h in a pulse mode at an anode voltage of above 25 kV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

150K - 200K miniature pulse tube cooler for micro satellites

Air Liquide is working with the CNES and Steel électronique in 2013 to design, manufacture and test a Miniature Pulse Tube Cooler (MPTC) to cool infrared detectors for micro-satellite missions. The cooler will be particularly adapted to the needs of the CNES MICROCARB mission to study atmospheric Carbon Dioxide which presents absorption lines in the thermal near infrared, at 1.6 μm and 2.0 μm. The required cooler temperature is from 150 to 200K with cooling power between 1 and 3 watts. The overall electrical power budget including electronics is less than 20W with a 288-300K rejection temperature. Particular attention is therefore paid to optimizing overall system efficiency. The active micro vibration reduction system and thermal control systems already developed for the Air Liquide Large Pulse Tube Cooler (LPTC) are currently being implemented into a new high efficiency electronic architecture. The presented work concerns the new cold finger and electronic design. The cooler uses the compressor already developed for the 80K Miniature Pulse Tube Cryocooler. This Pulse Tube Cooler addresses the requirements of space missions where extended continuous operating life time (>5 years), low mass and low micro vibration levels are critical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of microwave interaction with magnetoplasma in miniature multipolar configuration using impedance measurements

A miniature microwave plasma source employing both radial and axial magnetic fields for plasma confinement has been developed for micro-propulsion applications. Plasma is initiated by launching microwaves via a short monopole antenna to circumvent geometrical cutoff limitations. The amplitude and phase of the forward and reflected microwave power is measured to obtain the complex reflection coefficient from which the equivalent impedance of the plasma source is determined. Effect of critical plasma density condition is reflected in the measurements and provides insight into the working of the miniature plasma source. A basic impedance calculation model is developed to help in understanding the experimental observations. From experiment and theory, it is seen that the equivalent impedance magnitude is controlled by the coaxial discharge boundary conditions, and the phase is influenced primarily by the plasma immersed antenna impedance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant inelastic X-ray scattering using a miniature dispersive Rowland refocusing spectrometer

X-ray absorption spectroscopy (XAS) beamlines worldwide are steadily increasing their emphasis on full photon-in/photon-out spectroscopies, such as resonant inelastic X-ray scattering (RIXS), resonant X-ray emission spectroscopy (RXES) and high energy resolution fluorescence detection XAS (HERFD-XAS). In such cases, each beamline must match the choice of emission spectrometer to the scientific mission of its users. Previous work has recently reported a miniature tender X-ray spectrometer using a dispersive Rowland refocusing (DRR) geometry that functions with high energy resolution even with a large X-ray spot size on the sample. This instrument has been used in the laboratory in multiple studies of non-resonant X-ray emission spectroscopy using a conventional X-ray tube, though only for preliminary measurements at a low-intensity microfocus synchrotron beamline. This paper reports an extensive study of the performance of a miniature DRR spectrometer at an unfocused wiggler beamline, where the incident monochromatic flux allows for resonant studies which are impossible in the laboratory. Here, the results support the broader use of the present design and also suggest that the DRR method with an unfocused beam could have important applications for materials with low radiation damage thresholds and that would not survive analysis on focused beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized magnet-less RF electron trap. II. Experimental verification

Atomic microsystems have the potential of providing extremely accurate measurements of timing and acceleration. But, atomic microsystems require active maintenance of ultrahigh vacuum in order to have reasonable operating lifetimes and are particularly sensitive to magnetic fields that are used to trap electrons in traditional sputter ion pumps. Our paper presents an approach to trapping electrons without the use of magnetic fields, using radio frequency (RF) fields established between two perforated electrodes. The challenges associated with this magnet-less approach, as well as the miniaturization of the structure, are addressed. These include, for example, the transfer of large voltage (100–200 V) RF power to capacitive loads presented by the structure. The electron trapping module (ETM) described here uses eight electrode elements to confine and measure electrons injected by an electron beam, within an active trap volume of 0.7 cm 3 . The operating RF frequency is 143.6 MHz, which is the measured series resonant frequency between the two RF electrodes. It was found experimentally that the steady state electrode potentials on electrodes near the trap became more negative after applying a range of RF power levels (up to 0.15 W through the ETM), indicating electron densities of ≈3 × 10 5 cm -3 near the walls of the trap. The observed results align well with predicted electron densities from analytical and numerical models. The peak electron density within the trap is estimated as ~1000 times the electron density in the electron beam as it exits the electron gun. Finally, this successful demonstration of the RF electron trapping concept addresses critical challenges in the development of miniaturized magnet-less ion pumps.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗

Vibration measurement of a miniature component by high-speed image-plane digital holographic microscopy

Measuring deformation of vibrating specimens whose dimensions are in the submillimeter range introduces a number of difficulties using laser interferometry. Normal interferometry is not suitable because of a phase ambiguity problem. In addition, the noise effect is much more serious in the measurement of small objects because a high-magnification lens is used. We present a method for full-field measurement of displacement, velocity, and acceleration of a vibrating miniature object based on image-plane digital holographic microscopy. A miniature cantilever beam is excited by a piezoelectric transducer stage with a sinusoidal configuration. A sequence of digital holograms is captured using a high-speed digital holographic microscope. Windowed Fourier analysis is applied in the spatial and spatiotemporal domains to extract the displacement, velocity and acceleration. The result shows that a combination of image-plane digital holographic microscopy and windowed Fourier analyses can be used to study vibration without encountering a phase ambiguity problem, and one can obtain instantaneous kinematic parameters on each point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transition Fracture Toughness Characterization of Eurofer 97 Steel using Pre-Cracked Miniature Multi-notch Bend Bar Specimens

In this report, we present the feasibility study of using pre-cracked miniature multi-notch bend bar specimens (M4CVN) with a dimension of 45mm (length) x 3.3mm (width) x 1.65mm (thickness) to characterize the transition fracture toughness of Eurofer97 based on the ASTM E1921 Master Curve method. From literature survey results, we did not find any obvious specimen size effects on the measured fracture toughness of unirradiated Eurofer97. Nonetheless, in order to exclude the specimen size effect on the measured fracture toughness of neutron irradiated Eurofer97, comparison of results obtained from larger size specimens with those from smaller size specimens after neutron irradiation is necessary, which is not practical and can be formidably expensive. However, limited literature results indicate that the transition fracture toughness of Eurofer97 obtained from different specimen sizes and geometries followed the similar irradiation embrittlement trend. We then described the newly designed experimental setup to be used for testing neutron irradiated Eurofer97 pre-cracked M4CVN bend bars in the hot cell. We recently used the same setup for testing neutron irradiated F82H pre-cracked miniature multi-notch bend bars with great success. Considering the similarity in materials, specimen types, and the nature of tests between Eurofer97 and F82H, we believe the newly designed experimental setup can be used successfully in fracture toughness testing of Eurofer97 pre-cracked M4CVN specimens.

36 MATERIALS SCIENCE↗

A parameterized ray-tracing model for evaluation of hemispherical lensing of a uniform, telecentric object aperture -- performance improvement estimates for segmented scintillators with miniature lens arrays

A parametric model describing the collimation of radiation from a uniform circular aperture by a hemispherical lens of the same radius has been developed for rapid estimation of the potential benefit of miniature dielectric lens arrays in lens-coupled gamma ray cameras (GRCs) with segmented scintillators. A simplified ray-tracing approach is adopted that makes use of small angle approximations relevant to GRCs used in nuclear science at Los Alamos National Laboratory and elsewhere. Application of this analysis technique in a first-pass design optimization process results in the optimistic estimate that miniature lenses fabricated from typical optical quality glass might boost optical coupling by as much as a factor of 4 (6 dB gain). However, this is not likely to be economically attractive compared to other techniques, such as reduction of the GRC lens f-number.

47 OTHER INSTRUMENTATION↗

NIF-TAS Miniature Calibration Station

“On Aug. 8, 2021, an experiment at Lawrence Livermore National Laboratory’s (LLNL’s) National Ignition Facility (NIF) made a significant step toward ignition, achieving a yield of more than 1.3 megajoules (MJ). This advancement puts researchers at the threshold of fusion ignition, an important goal of the NIF, and opens access to a new experimental regime.” NIF experiments are conducted by symmetrically focusing 192 laser beams from NIF (three football fields in length) into the Target Chamber (10-meter diameter sphere) onto a target 2mm in size. The reaction produces a hot spot the diameter of a human hair, generating more than 10 quadrillion watts of fusion power for 100 trillionths of a second. These high pressures and temperatures created by the NIF have only been seen on the surface of the sun. To achieve fusion ignition, the target must be compressed to high pressures and temperatures, which requires symmetric compression. This symmetry requires precise alignment of the laser beams to the target. To achieve this precise symmetry a Target Alignment System (TAS) was developed to aid in aligning the beams to the target. The accomplishment on Aug 8 th could not have been accomplished without the TAS. TAS has proven to be a critical contributor to the success of NIF experiments. Each TAS is composed of several Charge Couple Device (CCD) sensors and various support electronics. Unfortunately, these CCDs are no longer available in industry as they have become outdated and obsolete. There is a limited amount of spare CCDs in the facility. As the NIF continues to increase its energy output of its fusion ignition shot experiments (heigh yield shots), more neutrons are being emitted from the Target Chamber. These neutrons are very damaging to the TAS electronics and its sensors, thus degrading and reducing its life expectancy dramatically. The increase of neutrons exceeds the damage threshold of the CCDs. This would increase the demand for more frequent TAS refurbishments and calibrations. The increase in resources to perform these refurbishments and calibrations would not be sustainable. In efforts to prolong the life of each TAS system it was determined that the TAS should be removed for every High Yield Shot and then reinstalled. The high precision fully calibrated TAS can easily be knocked out of alignment during these installs and reinstall exchanges and being transported in and out of the NIF. The Miniature Calibration Station System was developed to verify that the critical calibration parameters have been preserved during every TAS exchange. The Miniature Calibration Station System (Mini-Cal) would need to be a scaled down (in size and scope), portable version of the offline TAS calibration station to verify the critical TAS parameters are still within tolerances.

42 ENGINEERING↗

Miniaturized Scanning Electrical Mobility Sizer (mSEMS) Instrument Handbook – Airborne Version

The miniaturized scanning electrical mobility sizer (mSEMS), as shown in Figure 1, represents an advancement in particle size measurement technology. Designed for portability, this compact instrument is engineered to deliver precise and accurate assessments of particle size distributions. The mSEMS uses scanning electrical mobility sizing technology to analyze aerosol particles within a specified size range. Its miniaturized design does not compromise on performance, making it ideal for a myriad of applications across laboratory research, environmental monitoring, and industrial settings. The user friendly interface simplifies operation, while the instrument's robust construction ensures reliability in various conditions. Researchers and professionals can rely on the mSEMS to provide invaluable insights into aerosol dynamics, contributing to advancements in aerosol science.

54 ENVIRONMENTAL SCIENCES↗

FY 2008 Miniature Spherical Retroreflectors – Final Report

Through the duration of the NNSA Office of Nuclear Nonproliferation Research and Development (NA-22) Miniature Spherical Retroreflectors lifecycle project, our research team focused on developing solutions to the fabrication bottleneck that has inhibited development and deployment of wide-angle optically interrogated chemical and radiological remote sensing technology. Our team advanced the concept of step-index clad retroreflectors to approximate an optimized, but yet unrealized spherical gradient index design. An intensive numerical simulation effort was undertaken that resulted in optimized step-index optical designs for mid-infrared applications. Geometric optics ray trace modeling was performed to better understand the geometrical dependencies of the miniature spherical retroreflector application. We adopted and advanced the concept of optical cross section, a metric that provides relative performance comparisons between different retroreflector designs and our cross-section analysis demonstrated that our step-index design provided 90% of the range capacity of the ideal spherical index design.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Miniature Coil for Wireless Power and Data Transfer through Aluminum

This paper presents the design and development of miniature coils for wireless power and data transfer through metal. Our coil has a total size of 15 mm × 13 mm × 6 mm. Experimental results demonstrate that we can harvest 440 mW through a 1 mm-thick aluminum plate. Aluminum and stainless-steel barriers of different thicknesses were used to characterize coil performance. Using a pair of the designed coils, we have developed a through-metal communication system to successfully transfer data through a 1 mm-thick aluminum plate. A maximum data rate of 100 bps was achieved using only harvested power. To the best of our knowledge, this is the first report that demonstrates power and data transfer through aluminum using miniature coils.

42 ENGINEERING↗

Environmental study of miniature slip rings

Investigation studied the long term operation of miniature slip ring assembles in high vacuum of space and included the influence of ring, brush, and insulator materials on electrical noise and mechanical wear. Results show that soft metal vapor plating and niobium diselenide miniature slip rings are beneficial.

Radnik, J. L.↗