Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEV RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Bremsstrahlung {gamma}-ray generation by electrons from gas jets irradiated by laser pulses for radiographic testing

Electron generation from a gas jet irradiated by low energy femtosecond laser pulses is studied experimentally as a promising source of radiation for radioisotope-free {gamma}-ray imaging systems. The calculated yield of {gamma}-rays in the 0.5-2 MeV range, produced by low-average-power lasers and gas targets, exceeds the yields from solid tape targets up to 60 times. In addition, an effect of quasi-mono energetic electrons on {gamma}-ray imaging is also discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Degradation mechanism of Ni-based superalloy under extreme irradiation environments

This report is a description of various materials (in particular, Rene N4) and their resilience under chemical, physical, and radioactive changes caused by heavy ion irradiation in the MeV range. The following conclusions were reached: the γ' precipitates become fully disordered at a dose of 0.3 dpa: the γ' precipitates partially dissolve after irradiation up to 75 dpa, and the chemical intermixing mainly originates from thermal spike effects; and combining effects of defect clusters, disordering and dissolution determine the evolution of hardness. This work is relevant to materials challenges for Gen IV reactors.

36 MATERIALS SCIENCE↗

N=2 ICRH of H majority plasmas in JET-ILW

Heating single ion species plasmas with ICRF is a challenging task: Fundamental ion cyclotron heating (w = w{sub ci}) suffers from the adverse polarization of the RF electric fields near the majority cyclotron resonance while second harmonic heating (w = 2w{sub ci}) typically requires pre-heating of the plasma ions to become efficient. Recently, w = 2w{sub ci} ICRF heating was tested in JET-ILW hydrogen plasmas in the absence of neutral beam injection (L-mode). Despite the lack of pre-heating, up to 6MW of ICRF power were coupled to the plasma leading to a transition to H-mode for P{sub ICRH}>5MW in most discharges. Heating efficiencies between 0.65-0.85 were achieved as a combination of the low magnetic field adopted (enhanced finite Larmor radius effects) and the deliberate slow rise of the ICRF power, allowing time for a fast ion population to gradually build-up leading to a systematic increase of the wave absorptivity. Although fast ion tails are a common feature of harmonic ICRF heating, the N=2 majority heating features moderate tail energies (<500keV) except at very low plasma densities (n{sub e0}<3x10{sup 19}/m{sup 3}), where fast H tails in the MeV range developed and fast ion losses became significant, leading to enhanced plasma wall interaction. The main results of these experiments will be reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-Induced Cavities and Solitons in Overcritical Hydrogen Plasma

A picosecond CO{sub 2} laser was used successfully in a number of experiments exploring advanced methods of particle acceleration. Proton acceleration from gas-jet plasma exemplifies another advantage of employing the increase in laser wavelength from the optical to the mid-IR region. Recent theoretical- and experimental-studies of ion acceleration from laser-generated plasma point to better ways to control the ion beam's energy when plasma approaches the critical density. Studying this regime with solid-state lasers is problematic due to the dearth of plasma sources at the critical electron density {approx}10{sup 21} cm{sup -3}, corresponding to laser wavelength {lambda} = 1 {mu}m. CO{sub 2} laser offers a solution. The CO{sub 2} laser's 10 {mu}m wavelength shifts the critical plasma density to 10{sup 19} cm{sup -3}, a value attainable with gas jets. Capitalizing on this approach, we focused a circular polarized 1-TW CO{sub 2} laser beam onto a hydrogen gas jet and observed a monoenergetic proton beam in the 1-2 MeV range. Simultaneously, we optically probed the laser/plasma interaction region with visible light, revealing holes bored by radiation pressure, as well as quasi-stationary soliton-like plasma formations. Our findings from 2D PIC simulations agree with experimental results and aid in their interpretation.

08 HYDROGEN↗

Dips in the diffuse supernova neutrino background

Scalar (fermion) dark matter with mass in the MeV range coupled to ordinary neutrinos and another fermion (scalar) is motivated by scenarios that establish a link between radiatively generated neutrino masses and the dark matter relic density. With such a coupling, cosmic supernova neutrinos, on their way to us, could resonantly interact with the background dark matter particles, giving rise to a dip in their redshift-integrated spectra. Current and future neutrino detectors, such as Super-Kamiokande, LENA and Hyper-Kamiokande, could be able to detect this distortion.

79 ASTRONOMY AND ASTROPHYSICS↗

Biological cell irradiation at ultrahigh dose rate employing laser driven protons

The ultrashort duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen's University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 10{sup 9}Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4{+-}0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source.

60 APPLIED LIFE SCIENCES↗

Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Neutrons for Science Facility at SPIRAL-2

The ''Neutrons for Science''(NFS) facility will be a component of SPIRAL-2, the future accelerator dedicated to the production of very intense radioactive ion beams, under construction at GANIL in Caen (France). NFS will be composed of a pulsed neutron beam for in-flight measurements and irradiation stations for cross-section measurements and material studies. Continuous and quasi-monokinetic energy spectra will be available at NFS respectively produced by the interaction of deuteron beam on thick a Be converter and by the {sup 7}Li(p,n) reaction on a thin converter. The flux at NFS will be up to 2 orders of magnitude higher than those of other existing time-of-flight facilities in the 1 MeV to 40 MeV range. NFS will be a very powerful tool for physics and fundamental research as well as applications like the transmutation of nuclear waste, design of future fission and fusion reactors, nuclear medicine or test and development of new detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results on cell irradiation with laser-driven protons on the TARANIS system

The ultra short duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen’s University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 10{sup 9} Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live, cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4±0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status of the heavy ion beam probe system in the Large Helical Device

A heavy ion beam probe (HIBP) system has been installed into the Large Helical Device (LHD) to measure the spatial profile of the plasma potential and density fluctuations. The optimization of the HIBP system, especially the beam injector, is described. The negative ion beam is required for the MeV beam production in a tandem accelerator. A sputter-type heavy negative ion source has been developed as an intense Au{sup -} beam source to produce Au{sup +} beams with energy in the MeV range. The extraction electrodes and the Einzel lens system of the ion source have been designed taking into account the beam optics, and installed into the real machine. Throughout the plasma diagnostics on LHD experiments, the consumptions of vaporized caesium and gold target are being characterized for practical operations. In addition, the experimental charge fractions are compared with the theoretical fractions for understanding the charge-changing behavior of Au{sup -} ions and optimizing the fraction of Au{sup +} ions at the exit of the tandem accelerator of the HIBP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EFFECT OF COHERENT STRUCTURES ON ENERGETIC PARTICLE INTENSITY IN THE SOLAR WIND AT 1 AU

We present results from an analysis of Advanced Composition Explorer (ACE) observations of energetic particles in the 0.047–4.78 MeV range associated with shocks and discontinuities in the solar wind. Previous work found a strong correlation between coherent structures and energetic particles measured by ACE/EPAM. Coherent structures are identified using the Partial Variance of Increments (PVI) method, which is essentially a normalized vector increment. The correlation was based on a superposed epoch analysis using over 12 years of data. Here, we examine many individual high-PVI events to better understand this association emphasizing intervals selected from data with shock neighborhoods removed. We find that in many cases the local maximum in PVI is in a region of rising or falling energetic particle intensity, which suggests that magnetic discontinuities may act as barriers inhibiting the motion of energetic particles across them.

79 ASTRONOMY AND ASTROPHYSICS↗

Prompt directional detection of galactic supernova by combining large liquid scintillator neutrino detectors

Core-collapse supernovae produce an intense burst of electron antineutrinos in the few-tens-of-MeV range. Several Large Liquid Scintillator-based Detectors (LLSD) are currently operated worldwide, being very effective for low energy antineutrino detection through the Inverse Beta Decay (IBD) process. In this article, we develop a procedure for the prompt extraction of the supernova location by revisiting the details of IBD kinematics over the broad energy range of supernova neutrinos. Combining all current scintillator-based detector, we show that one can locate a canonical supernova at 10 kpc with an accuracy of 45 degrees (68% C.L.). After the addition of the next generation of scintillator-based detectors, the accuracy could reach 12 degrees (68% C.L.), therefore reaching the performances of the large water Čerenkov neutrino detectors. We also discuss a possible improvement of the SuperNova Early Warning System (SNEWS) inter-experiment network with the implementation of a directionality information in each experiment. Finally, we discuss the possibility to constrain the neutrino energy spectrum as well as the mass of the newly born neutron star with the LLSD data.

79 ASTRONOMY AND ASTROPHYSICS↗

Metrology, applications and methods with high energy CT systems

The increase of Computed Tomography (CT) as an applicable metrology and Non Destructive Testing (NDT) method raises interest on developing the application fields to larger objects, which were rarely used in the past due to their requirements on the imaging system. Especially the classical X-ray generation techniques based on standard equipment restricted the applications of CT to typical material penetration lengths of only a few cm of steel. Even with accelerator technology that offers a suitable way to overcome these restrictions just the 2D radioscopy technique found a widespread application. Beside the production and detection of photons in the MeV range itself, the achievable image quality is limited using standard detectors due to the dominating absorption effect of Compton Scattering at high energies. Especially for CT reconstruction purposes these effects have to be considered on the development path from 2D to 3D imaging. Most High Energy CT applications are therefore based on line detectors shielding scattered radiation to a maximum with an increase in imaging quality but with time consuming large volume scan capabilities. In this contribution we present the High-Energy X-ray Imaging project at the Fraunhofer Development Centre for X-ray Technology with the characterization and the potential of the CT-system according to metrological and other application capabilities.

43 PARTICLE ACCELERATORS↗

Hydrogen decoration of radiation damage induced defect structures

The defect complexes that are formed when protons with energies in the MeV-range were implanted into high-purity silicon were investigated. After implantation, the samples were annealed at 400 °C or 450 °C for times ranging between 15 minutes and 30 hours. The resistivity of the samples was then analyzed by Spreading Resistance Profiling (SRP). The resistivity shows minima where there is a high carrier concentration and it is possible to extract the carrier concentration from the resistivity data. Initially, there is a large peak in the carrier concentration at the implantation depth where most of the hydrogen is concentrated. For longer anneals, this peak widens as the hydrogen diffuses away from the implantation depth. Following the changes in resistivity as a function of annealing time allows us to characterize the diffusion of hydrogen through these samples. Differences in the diffusion were observed depending on whether the silicon was grown by the magnetic Czochralski (m:Cz) method or the Float zone (Fz) method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of imaging plates to electrons between 40 and 180 MeV

This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d’Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Land-surface studies with a directional neutron detector.

Direct measurements of cosmic-ray neutron intensity were recorded with a neutron scatter camera developed at SNL. The instrument used in this work is a prototype originally designed for nuclear non-proliferation work, but in this project it was used to characterize the response of ambient neutrons in the 0.5-10 MeV range to water located on or above the land surface. Ambient neutron intensity near the land surface responds strongly to the presence of water, suggesting the possibility of an indirect method for monitoring soil water content, snow water equivalent depth, or canopy intercepted water. For environmental measurements the major advantage of measuring neutrons with the scatter camera is the limited (60{sup o}) field of view that can be obtained, which allows observations to be conducted at a previously unattainable spatial scales. This work is intended to provide new measurements of directional fluxes which can be used in the design of new instruments for passively and noninvasively observing land-surface water. Through measurements and neutron transport modeling we have demonstrated that such a technique is feasible.

54 ENVIRONMENTAL SCIENCES↗

Si film separation obtained by high energy proton implantation

High energy protons implantation in the 1-1.5 MeV range can be used to detach free-standing thin silicon films with thickness between 15 and 30 {mu}m. Recently, we showed that Si orientation has a strong effect on the layer separation threshold fluence and efficiency. While complete delamination of (111)Si films is achieved, (100)Si films separation is more challenging due to blistering phenomena or partial separation of the implanted layer. In this work, we study the fracture mechanism in (100) and (111)Si after high energy implantation in order to understand the origin of such a behavior. We notably point out that fracture precursor defects, i.e. the platelets, preferentially form on (111) planes, as a consequence of the low strain level in the damaged region in our implantation conditions. Fracture therefore propagates easily in (111)Si, while it requires higher fluence to overcome unfavorable precursors orientation and propagate in (100)Si.

36 MATERIALS SCIENCE↗