Cost and Performance of PC and IGCC Plants for a Range of Carbon Dioxide Capture - Rev. 1
The objective of this study was to establish the cost and performance for a range of carbon dioxide (CO 2 ) capture levels for new supercritical (SC) pulverized coal (PC) and integrated gasification combined cycle (IGCC) power plants. The SC PC cases (Case 1 series) utilize Fluor’s Econamine FG Plus SM process for post-combustion CO 2 capture via temperature swing absorption with a 30 wt% monoethanolamine (MEA) solution as the chemical solvent. The IGCC cases (Case 2 series) employ a slurry-fed, entrained-flow General Electric Energy (GEE) gasifier and leverage UOP’s (formerly Universal Oil Products) two-stage Selexol™ process for bulk CO 2 capture and selective hydrogen sulfide (H 2 S) removal via pressure swing absorption. The Selexol™ process uses dimethyl ether of polyethylene glycol (DEPG) as a physical solvent for pre-combustion capture.