Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mass spectrometry in structural and stereochemical problems. CXCIX.

Electron-impact induced fragmentations of o-, m-, and p-hydroxyalkylphenones and their trimethylsilyl (TMS) ethers are studied by means of high-resolution mass spectrometry, metastable defocusing, and deuterium labeling of the TMS ether derivatives. A markedly increased methyl radical loss from the o-TMS ether is attributed to a proximity effect. Minor fragmentation was observed with m- and p-isomers. Significantly intense doubly-charged ions were formed from ketonic cleavage and by the loss of a TMS methyl radical. The sequence of fragmentation was found to depend on the size of the alkyl group attached to the ketone carbonyl.

Smith, G. G.↗

Development of mass spectrometric techniques applicable to the search for organic matter in the lunar crust

Data processing techniques were developed to measure with high precision and sensitivity the line spectra produced by a high resolution mass spectrometer. The most important aspect of this phase was the interfacing of a modified precision microphotometer-comparator with a computer and the improvement of existing software to serve the special needs of the investigation of lunar samples. In addition, a gas-chromatograph mass spectrometer system was interfaced with the same computer to allow continuous recording of mass spectra on a gas chromatographic effluent and efficient evaluation of the resulting data. These techniques were then used to detect and identify organic compounds present in the samples returned by the Apollo 11 and 12 missions.

Biemann, K.↗

Isotopic composition of cosmic ray nuclei with Z greater than or equal to 10

Results of measurements of the isotopic composition of Z greater than or equal to 10 cosmic ray nuclei using a new technique employing a combination of Cerenkov and total energy counters. An effective mass resolution of about 0.4 AMU is obtained for particles with energies between 400 and 500 MeV/nuc and charges between 12 and 16. The preliminary mass distribution of nuclei with charges from 12 to 28 is presented and discussed.

Webber, W. R.↗

A Cerenkov-delta E-Cerenkov detector for high energy cosmic ray isotopes and an accelerator study of Ar-40 and Fe-56 fragmentation

A high energy cosmic ray detector--the High Energy Isotope Spectrometer Telescope (HEIST) is described. It is a large area (0.25 m(swp 2) SR) balloon borne isotope spectrometer designed to make high resolution measurements of isotopes in the element range from neon to nickel (10 Z 28) at energies of about 2 GeV/nucleon. HEIST determines the mass of individual nuclei by measuring both the change in the Lorentz factor (delta gamma) that results from traversing the NaI stack, and the energy loss (delta E) in the stack. Since the total energy of an isotope is given by E = (gamma M), the mass M can be determined by M = delta E/delta, gamma. The instrument is designed to achieve a typical mass resolution of 0.2 amu. The isotopic composition of the fragments from the breakup of high energy An-40 and Fe-56 nuclei are measured experimentally. Isotope yields are compared with calculated yields based on semi-empirical cross-section formulae.

Lau, K. H.↗

Bevalac studies of magnet Cerenkov spectroscopy

The attempt was made to identify the various contributions to the velocity resolution of Cerenkov detectors such as might be used in Astromag, to measure the magnitude of these contributions and assess their effect on the mass resolution of an isotope spectrometer for Astromag, and to perform Bevalac tests of magnet/Cerenkov spectroscopy. A first version of a new 5 in. photomultiplier tube was also tested that is designed for use in large magnetic fields.

Source record↗

Water Storage Trends in High Mountain Asia

Changes in terrestrial water storage (TWS) in High Mountain Asia (HMA) could have major societal impacts, as the region’s large reservoirs of glaciers, snow, and groundwater provide a freshwater source to more than one billion people. We seek to quantify and close the budget of secular changes in TWS over the span of the GRACE satellite mission (2003–2016). To assess the TWS trend budget we consider a new high-resolution mass trend product determined directly from GRACE L1B data, glacier mass balance derived from Digital Elevation Models (DEMs), groundwater variability determined from confined and unconfined well observations, and terrestrial water budget estimates from a suite of land surface model simulations with the NASA Land Information System (LIS). This effort is successful at closing the aggregated TWS trend budget over the entire HMA region, the glaciated portion of HMA, and the Indus and Ganges basins, where the full-region trends are primarily due to the glacier mass balance and groundwater signals. Additionally, we investigate the closure of TWS trends at individual 1-arc-degree mascons (area ≈12,000 km2); a significant improvement in spatial resolution over previous analyses of GRACE-derived trends. This mascon-level analysis reveals locations where the TWS trends are well-explained by the independent datasets, as well as regions where they are not; identifying specific geographic areas where additional data and model improvements are needed. The accurate characterization of total TWS trends and its components presented here is critical to understanding the complex dynamics of the region, and is a necessary step toward projecting future water mass changes in HMA.

Bryant D Loomis↗

SPIRIT - A high resolution cosmic ray isotope spectrometer for Spacelab

An instrument to measure the isotopic abundances of cosmic ray nuclei with Z in the range 20-30 and A in the range 40-70 has been conceived. The instrument, named SPIRIT (Superconducting Passive Iron Isotope Telescope), will have the mass resolution (sigma less than 0.15 amu) and collecting power (151 sq m ster h for a 10 day flight) to detect and convincingly resolve isotopes as rare as 0.5% of the total abundance of each element. Both range and magnetic rigidity are measured by following tracks through an array of sheets of CR-39, a sensitive new track-recording plastic, which had been kept in fixed position at uniform temperature within the uniform field region of a large superconducting magnet.

Tarle, G.↗

Cosmic ray isotope resolution obtained using a new Cerenkov-total energy telescope

The details of a recent measurement of the cosmic ray isotopic composition of Z equals or exceeds 10 nuclei are given, using a new technique combining a Cerenkov and total energy counter. In terms of sigma, the characteristic width of a Gaussian distribution of mass measurement, values of mass resolution have been obtained ranging from about 0.4 AMU at a Z about 14, to about 0.8 AMU at a Z about 26, using the Cerenkov-total energy (C x E) technique. It is customary to claim that two equal Gaussian distributions may be resolved for values of sigma less than 0.4 x the separation of their means. With these criteria isotopes separated by delta A = 2 are being resolved up to a Z about 26 using the C x E technique. An important source of error in these measurements is the determination of the mass of each of the isotopes on an absolute scale.

Webber, W. R.↗

Ammonia 15N/14N Isotope Ratio in the Jovian Atmosphere

Data from the Galileo Probe Mass Spectrometer has been used to derive the N-15/N-14 isotope ratio in ammonia at Jupiter. Although the mass spectral interference from the water contribution to 18 amu makes an accurate derivation of the (N-15)H3/(N-14)H3 ratio difficult from measurements of the singly ionized signals at 18 and 17 amu, this interference is not present in the doubly charged 8.5 and 9.0 amu signals from (N-14)H3++ and (N-15)H3++ respectively. Although the count rate from the 9 amu signal is low during the direct sampling of the atmosphere, the ammonia signal was considerably enhanced during the first enrichment cell (EC1) experiment that measured gas sampled between 0.8 and 2.8 bar. Count rates at 9 amu in the EC1 experiment reach 60/second and measure ammonia sampled from 0.88 to 2.8 bar. In the EC1 measurements the 8.5 amu signal is not measured directly, but can be calculated from the ammonia contribution to 17 amu and the ratio of NH3 ions of a double to single charged observed during a high resolution mass scan taken near the end of the descent. The high resolution scan gives this ratio from ammonia sampled much deeper in the atmosphere. These results are described and compared with Infrared Space Observatory-Short Wavelength Spectrometer (ISO-SWS) observations that give this ratio at 400 mbar.

Mahaffy, P.R.↗

Small Business Innovations (Mass Microbalance)

Femtometrics of Costa Mesa, CA, developed the Model 200-1 SAW Mass Microbalance under a NASA Small Business Innovation Research (SBIR) contract with Langley Research Center. The product is described as "the next generation of aerosol mass microbalance technology," because a new type of sensor, the Surface Acoustic Wave (SAW) piezoelectric crystal, offers mass resolution two orders of magnitude greater than the Quartz Crystal Microbalance cascade impactor (QCM) (used at Langley since 1979 for collection and measurement of aerosol particles in the upper atmosphere). The Model 200-1 SAW Mass Microbalance, which provides a 400-fold increase in mass sensitivity per unit area over the QCM, can be used for real-time particle monitoring in clean rooms, measuring chemical vapors in very low concentrations, measuring target chemicals in the stratosphere and in industry as a toxic vapor monitor.

Source record↗

High resolution measurements of galactic cosmic-ray neon, magnesium, and silicon isotopes

High-resolution measurements of the abundances of individual isotopes of neon, magnesium and silicon in galactic cosmic rays are reported. The Caltech Heavy Isotope Spectrometer Telescope on board the ISEE 3 spacecraft was used to obtain measurements in the range 30 to 180 MeV/n at an rms mass resolution of 0.20 amu. Results indicate excesses of Ne-22 as well as Mg-25 and Mg-26 in galactic cosmic rays with respect to their solar system abundances. Calculations of the effects of interstellar propagation and solar modulation on cosmic-ray isotope abundances also imply an Mg-25 + Mg-26 cosmic ray source fraction significantly greater than the solar system fraction, and it is suggested that the cosmic ray source material and solar system material were synthesized under different conditions.

Mewaldt, R. A.↗

Enabling the Next Generation of Spaceborne Quadrupole Mass Spectrometers

The quadrupole mass spectrometer (QMS) has over 30 years of spaceflight heritage in making important neutral gas and low energy ion observations. Given their geometrical constraints, these instruments are currently operated at the extreme limit of their capabilities. However, a technique called higher order auxiliary excitation provides a set of novel, robust, electronics-based solutions for improving the performance of these sensors. By driving the quadrupole rods with an additional frequency nearly twice that of the normal RF operating frequency, substantially increased abundance sensitivity, maximum attainable mass resolution, and peak stability can be achieved through operation of voltage scan lines through the center of formed upper stability islands. Such improvements are modeled using numerical simulations of ion trajectories in a quadrupole field with and without applied higher order auxiliary excitation. When compared to a traditional QMS with a mass range up to 500Da, sensors can be designed with the same precision electronics to have expected mass ranges beyond 1500Da with a power increase of less than twice that of its heritage implementations.

Gershman, D. J.↗

Cosmic Ray-Air Shower Measurement from Space

A feasibility study has been initiated to observe from space the highest energy cosmic rays above 1021 eV. A satellite observatory concept, the Maximum-energy Auger (Air)-Shower Satellite (MASS), is recently renamed as the Orbital Wide-angle Collector (OWL) by taking its unique feature of using a very wide field-of-view (FOV) optics. A huge array of imaging devices (about 10(exp 6) pixels) is required to detect and record fluorescent light profiles of cosmic ray cascades in the atmosphere. The FOV of MASS could extend to as large as about 60 in. diameter, which views (500 - 1000 km) of earth's surface and more than 300 - 1000 cosmic ray events per year could be observed above 1020 eV. From far above the atmosphere, the MASS/OWL satellite should be capable of observing events at all angles including near horizontal tracks, and would have considerable aperture for high energy photon and neutrino observation. With a large aperture and the spatial and temporal resolution, MASS could determine the energy spectrum, the mass composition, and arrival anisotropy of cosmic rays from 1020 eV to 1022 eV; a region hitherto not explored by ground-based detectors such as the Fly's Eye and air-shower arrays. MASS/OWL's ability to identify cosmic neutrinos and gamma rays may help providing evidence for the theory which attributes the above cut-off cosmic ray flux to the decay of topological defects. Very wide FOV optics system of MASS/OWL with a large array of imaging devices is applicable to observe other atmospheric phenomena including upper atmospheric lightning. The wide FOV MASS optics being developed can also improve ground-based gamma-ray observatories by allowing simultaneous observation of many gamma ray sources located at different constellations.

Takahashi, Yoshiyuki↗

An X-Ray Spectroscopic Search For Dark Matter And Unidentified Line Signatures In The Perseus Cluster With Hitomi

The reported detection of a 3.5 keV emission signal in the Perseus cluster core by Bulbulet al. (2014, ApJ, 789, 13) was ruled out at high confidence in analysis conducted by Aharonian et al. (2017, ApJ, 837, L15) of X-ray spectra at 5 eV energy resolution obtained with the Hitomi observatory Soft X-ray Spectrometer (SXS). Using the same data, we search the full 2–12 keV SXS energy band for previously unidentified emission and absorption features. No significant unidentified line emission or absorption is found. Line flux upper limits (1σper resolution element) vary with photon energy and assumed intrinsic width, decreasing from∼100 at 2 keV to<10 photons cm−2s−1sr−1over most of the 5–10 keV energy range for a Gaussian line with Doppler broadening of 640 kms−1. Limits for narrower and broader lines have a similar energy dependence and are systematically smaller and larger, respectively. These line flux limits are used to constrain the decay rate of hypothetical dark matter candidates. For the sterile neutrino decay rate, we place new constraints over the mass range of 4–24 keV with mass resolution better than any previous X-ray analysis. Additionally, the accuracy of relevant thermal spectral models and atomic data are evaluated. The Perseus cluster spectra may be described by a composite of multi-temperature thermal and active galactic nuclei (AGN) power-law continua. Superposed on these, a few line emission signals possibly originating from unmodeled atomic processes (including SiXIV and FeXXV)are marginally detected and tabulated. Comparisons with previous X-ray upper limits and future prospects for dark matter searches using high-energy resolution spectroscopy are discussed.

Takayuki Tamura↗

Negative Ion Chemistry in the Coma of Comet 1P/Halley

Negative ions (anions) were identified in the coma of comet 1P/Halley from in-situ measurements performed by the Giotto spacecraft in 1986. These anions were detected with masses in the range 7-110 amu, but with insufficient mass resolution to permit unambiguous identification. We present details of a new chemical-hydrodynamic model for the coma of comet Halley that includes - for the first time - atomic and molecular anions, in addition to a comprehensive hydrocarbon chemistry. Anion number densities arc calculated as a function of radius in the coma, and compared with the Giotto results. Important anion production mechanisms arc found to include radiative electron attachment, polar photodissociation, dissociative electron attachment, and proton transfer. The polyyne anions C4H(-) and C6H(-) arc found to be likely candidates to explain the Giotto anion mass spectrum in the range 49-73 amu. Thc CN(-) anion probably makes a significant contribution to the mass spectrum at 26 amu. Larger carbon-chain anions such as C8H(1) can explain the peak near 100 amu provided there is a source of large carbon-chain-bearing molecules from the cometary nucleus.

Cordiner, M. A.↗

Cosmic ray isotope abundances from chromium to nickel

IRIS, a telescope consisting of a large-area precision Cerenkov detector, scintillators, spark chambers, and a passive stack of Lexan polycarbonate track detectors, was exposed to the primary cosmic radiation for 6.6 sq m sr hr in a balloon flight in 1976. This measurement has yielded the isotopic composition of the iron-group elements Cr, Mn, Fe, and Ni with an average mass resolution of 0.65 amu for the energies 320-500 MeV per amu at the detector. This experiment places the most severe constraints to date on deviation from solar-system composition of the source of the cosmic radiation. Upper limits of 10 percent are placed on the ratios Fe-54/Fe-56 and Fe-58/Fe-56, which are inconsistent with large departures from solar system source composition reported by other workers. The isotopic measurements of Fe and Ni preclude the possibility that these cosmic rays were produced in a single e-process zone. The mean mass of Mn is less than 55, indicating the presence of electron-capture species produced by spallation.

Tarle, G.↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗

VIPER’s Mass Spectrometer observing lunar operations (MSolo)

The Volatiles Investigating Polar Exploration Rover (VIPER) is a lunar volatiles detection and measurement mission that will land on Mons Mouton near Nobile crater, close to the Moon’s south pole. One of the analytical instruments embedded within the rover is the Mass Spectrometer observing lunar operations (MSolo) instrument. VIPER’s data will ultimately be used to create lunar water resource maps that may enable a sustained presence on the lunar surface. As VIPER navigates several kilometers of terrain, its onboard analytical instrumentation will characterize the presence of volatiles along the traverse path and identify candidate locations for drilling. Upon selection of a drilling site, the rover will position itself and deploy an auguring, percussive drill down to a meter depth. Upon extraction, regolith cuttings captured by the auger are deposited on the surface; an activity that will initiate the release of any volatile gases that are subsequently detected and quantified by MSolo. MSolo is designed to identify low-molecular-weight volatiles (between m/z 1-100) with unit mass resolution. Volatiles of interest include D/H and O18/O16 bearing species, including possible water contained within the lunar regolith. MSolo is a modified, commercial off-the-shelf (COTS) system, meaning the instrument is based on a commercially available unit that has been ruggedized for space applications.

MSolo↗