Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASKING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Particle removal challenges with EUV patterned mask for the sub-22nm HP node

The particle removal efficiency (PRE) of cleaning processes diminishes whenever the minimum defect size for a specific technology node becomes smaller. For the sub-22 nm half-pitch (HP) node, it was demonstrated that exposure to high power megasonic up to 200 W/cm{sup 2} did not damage 60 nm wide TaBN absorber lines corresponding to the 16 nm HP node on wafer. An ammonium hydroxide mixture and megasonics removes {ge}50 nm SiO{sub 2} particles with a very high PRE, A sulfuric acid hydrogen peroxide mixture (SPM) in addition to ammonium hydroxide mixture (APM) and megasonic is required to remove {ge}28 nm SiO{sub 2} particles with a high PRE. Time-of-flight secondary ion mass spectroscopy (TOFSIMS) studies show that the presence of O{sub 2} during a vacuum ultraviolet (VUV) ({lambda} = 172 nm) surface conditioning step will result in both surface oxidation and Ru removal, which drastically reduce extreme ultraviolet (EUV) mask life time under multiple cleanings. New EUV mask cleaning processes show negligible or no EUV reflectivity loss and no increase in surface roughness after up to 15 cleaning cycles. Reviewing of defect with a high current density scanning electron microscope (SEM) drastically reduces PRE and deforms SiO{sub 2} particles. 28 nm SiO{sub 2} particles on EUV masks age very fast and will deform over time, Care must be taken when reviewing EUV mask defects by SEM. Potentially new particles should be identified to calibrate short wavelength inspection tools, Based on actinic image review, 50 nm SiO{sub 2} particles on top of the EUV mask will be printed on the wafer.

36 MATERIALS SCIENCE↗

Extreme ultraviolet mask substrate surface roughness effects on lithography patterning

In extreme ultraviolet lithography exposure systems, mask substrate roughness induced scatter contributes to LER at the image plane. In this paper, the impact of mask substrate roughness on image plane speckle is explicitly evaluated. A programmed roughness mask was used to study the correlation between mask roughness metrics and wafer plane aerial image inspection. We find that the roughness measurements by top surface topography profile do not provide complete information on the scatter related speckle that leads to LER at the image plane. We suggest at wavelength characterization by imaging and/or scatter measurements into different frequencies as an alternative for a more comprehensive metrology of the mask substrate/multilayer roughness effects.

36 MATERIALS SCIENCE↗

Beam studies at the SPEAR3 synchrotron using a digital optical mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Management in Nanofiber-Based Face Mask

Face masks are widely used to filter airborne pollutants, especially when particulate matter (PM) pollution has become a serious concern to public health. Here in this paper, the concept of thermal management is introduced into face masks for the first time to enhance the thermal comfort of the user. A system of nanofiber on nanoporous polyethylene (fiber/nanoPE) is developed where the nanofibers with strong PM adhesion ensure high PM capture efficiency (99.6% for PM 2.5 ) with low pressure drop and the nanoPE substrate with high-infrared (IR) transparency (92.1%, weighted based on human body radiation) results in effective radiative cooling. We further demonstrate that by coating nanoPE with a layer of Ag, the fiber/Ag/nanoPE mask shows a high IR reflectance (87.0%) and can be used for warming purposes. These multifunctional face mask designs can be explored for both outdoor and indoor applications to protect people from PM pollutants and simultaneously achieve personal thermal comfort.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-purity Polypropylene from Disposable Face Masks via Solvent-Targeted Recovery and Precipitation

The high use of disposable face masks since the start of COVID-19 has globally generated 4.68–6.24 million tons per year of waste from personal protective equipment. Disposable face masks are generally disposed of in landfills. Polypropylene (PP) is the main component in face masks, which is one of the least recycled plastics but has a high market value. In this work, we extract high-quality PP from face masks using solvent-targeted recovery and precipitation (STRAP) with 90 wt% recovery. N,N-Dimethylacetamide removed the color from the recovered PP to produce a clear high-purity PP, as verified by CIELAB color space. The decolored PP shows similar thermochemical properties and color to virgin PP resin. Here, a techno-economic analysis of the process indicates that high-purity PP recovery can be economically viable at a scale of 5000 tons per year or higher.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated mask creation from a 3D model using Faethm.

We have developed and implemented a method which given a three-dimensional object can infer from topology the two-dimensional masks needed to produce that object with surface micro-machining. The masks produced by this design tool can be generic, process independent masks, or if given process constraints, specific for a target process. This design tool calculates the two-dimensional mask set required to produce a given three-dimensional model by investigating the vertical topology of the model.

36 MATERIALS SCIENCE↗

Face mask integrated with flexible and wearable manganite oxide respiration sensor

Face masks are key personal protective equipment for reducing exposure to viruses and other environmental hazards such as air pollution. Integrating flexible and wearable sensors into face masks can provide valuable insights into personal and public health. The advantages that a breath-monitoring face mask requires, including multi-functional sensing ability and continuous, long-term dynamic breathing process monitoring, have been underdeveloped to date. Here, we design an effective human breath monitoring face mask based on a flexible La 0.7 Sr 0.3 MnO 3 (LSMO)/Mica respiration sensor. The sensor’s capabilities and systematic measurements are investigated under two application scenes, namely clinical monitoring mode and daily monitoring mode, to monitor, recognise, and analyse different human breath status, i.e., cough, normal breath, and deep breath. This sensing system exhibits super-stability and multi-modal capabilities in continuous and long-time monitoring of the human breath. We determine that during monitoring human breath, thermal diffusion in LSMO is responsible for the change of resistance in flexible LSMO/Mica sensor. Both simulated and experimental results demonstrate good discernibility of the flexible LSMO/Mica sensor operating at different breath status. Our work opens a route for the design of novel flexible and wearable electronic devices.

36 MATERIALS SCIENCE↗

Mask-Assisted Seeded Growth of Segmented Metallic Heteronanostructures

Controlling the deposition of exotic metals in the seeded growth of multi-metal nanostructures is challenging. This work describes a seeded growth method assisted by a mask for synthesis of segmented binary or ternary metal nanostructures. Silica is used as a mask to partially block the surface of a seed and a second metal is subsequently deposited on the exposed area, forming a bimetallic heterodimer. The initial demonstration was carried out on a Au seed, followed by deposition of Pd or Pt on the seed. It was found that Pd tends to spread out laterally on the seed while Pt inclines to grow vertically into branched topology on Au. Without removal of the SiO₂ mask, Pt could be further deposited on the unblocked Pd of the Pd-Au dimer to form a Pt-Pd-Au trimer. The mask-assisted seeded growth provides a general strategy to construct segmented metallic nanoarchitectures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Planck CMB anomalies: astrophysical and cosmological secondary effects and the curse of masking

Large-scale anomalies have been reported in CMB data with both WMAP and Planck data. These could be due to foreground residuals and or systematic effects, though their confirmation with Planck data suggests they are not due to a problem in the WMAP or Planck pipelines. If these anomalies are in fact primordial, then understanding their origin is fundamental to either validate the standard model of cosmology or to explore new physics. We investigate three other possible issues: 1) the trade-off between minimising systematics due to foreground contamination (with a conservative mask) and minimising systematics due to masking, 2) astrophysical secondary effects (the kinetic Doppler quadrupole and kinetic Sunyaev-Zel'dovich effect), and 3) secondary cosmological signals (the integrated Sachs-Wolfe effect). We address the masking issue by considering new procedures that use both WMAP and Planck to produce higher quality full-sky maps using the sparsity methodology (LGMCA maps). We show the impact of masking is dominant over that of residual foregrounds, and the LGMCA full-sky maps can be used without further processing to study anomalies. We consider four official Planck PR1 and two LGMCA CMB maps. Analysis of the observed CMB maps shows that only the low quadrupole and quadrupole-octopole alignment seem significant, but that the planar octopole, Axis of Evil, mirror parity and cold spot are not significant in nearly all maps considered. After subtraction of astrophysical and cosmological secondary effects, only the low quadrupole may still be considered anomalous, meaning the significance of only one anomaly is affected by secondary effect subtraction out of six anomalies considered. In the spirit of reproducible research all reconstructed maps and codes will be made available for download here http://www.cosmostat.org/anomaliesCMB.html.

79 ASTRONOMY AND ASTROPHYSICS↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

The Effects of Oxygen Plasma on the Chemical Composition and Morphology of the Ru Capping Layer of the Extreme Ultraviolet (EUV) Mask Blanks

Contamination removal from extreme ultraviolet (EUV) mask surfaces is one of the most important aspects to improve reliability for the next generation of EUV lithography. We report chemical and morphological changes of the ruthenium (Ru) mask surface after oxygen plasma treatment using surface sensitive analytical methods: X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and transmission electron microscopy (TEM). Chemical analysis of the EUV masks shows an increase in the subsurface oxygen concentration, Ru oxidation and surface roughness. XPS spectra at various photoelectron takeoff angles suggest that the EUV mask surface was covered with chemisorbed oxygen after oxygen plasma treatment. It is proposed that the Kirkendall effect is the most plausible mechanism that explains the Ru surface oxidation. The etching rate of the Ru capping layer by oxygen plasma was estimated to be 1.5 {+-} 0.2 {angstrom}/min, based on TEM cross sectional analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly selective etching of silicon nitride to physical-vapor-deposited a-C mask in dual-frequency capacitively coupled CH{sub 2}F{sub 2}/H{sub 2} plasmas

A multilevel resist (MLR) structure can be fabricated based on a very thin amorphous carbon (a-C) layer ( congruent with 80 nm) and Si{sub 3}N{sub 4} hard-mask layer ( congruent with 300 nm). The authors investigated the selective etching of the Si{sub 3}N{sub 4} layer using a physical-vapor-deposited (PVD) a-C mask in a dual-frequency superimposed capacitively coupled plasma etcher by varying the process parameters in the CH{sub 2}F{sub 2}/H{sub 2}/Ar plasmas, viz., the etch gas flow ratio, high-frequency source power (P{sub HF}), and low-frequency source power (P{sub LF}). They found that under certain etch conditions they obtain infinitely high etch selectivities of the Si{sub 3}N{sub 4} layers to the PVD a-C on both the blanket and patterned wafers. The etch gas flow ratio played a critical role in determining the process window for infinitely high Si{sub 3}N{sub 4}/PVD a-C etch selectivity because of the change in the degree of polymerization. The etch results of a patterned ArF photoresisit/bottom antireflective coating/SiO{sub x}/PVD a-C/Si{sub 3}N{sub 4} MLR structure supported the idea of using a very thin PVD a-C layer as an etch-mask layer for the Si{sub 3}N{sub 4} hard-mask pattern with a pattern width of congruent with 80 nm and high aspect ratio of congruent with 5.

36 MATERIALS SCIENCE↗

Zone plate-based extreme ultraviolet mask microscope with through-pellicle imaging capability

Mirror-based and zone plate-based imaging systems are being used in actinic extreme ultraviolet (EUV) reticle review tools. With regard to zone plates, a short working distance is advantageous in terms of the required spectral bandwidth, manufacturability, and potential throughput and imaging performance. Zone plates therefore typically have a short working distance. The industry has adopted the use of an EUV pellicle to protect the photomask. Imaging photomask through-pellicle requires a working distance larger than 2.5 mm. A zone-plate-based EUV mask microscope with a 3-mm working distance has been commissioned at beamline 11.3.2 of the Advanced Light Source. Through-pellicle imaging at an exposure time of 2 s is demonstrated. The instrument achieves an image contrast of 95% on large features on a photomask with a tantalum-based absorber. Imaging down to 45-nm half pitch (mask scale) is demonstrated. A NILS of 2.55 is achieved on 60-nm half-pitch (mask scale) lines and spaces. These results demonstrate that zone-plate-based imaging systems can meet the requirements of an actinic EUV mask review tool in terms of imaging performance and throughput in an instrument compatible with EUV pellicles.

Extreme ultraviolet↗

SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study accrual and patient/provider satisfaction survey collection remain ongoing. This study is supported by VisionRT, Ltd.

60 APPLIED LIFE SCIENCES↗

A Study of the Isolation Region of Planar Superconducting YBCO Structures Formed by the Master Mask Method

Abstract—The development of a new “master mask” method for the manufacture of planar structures based on a high-temperature YBCO superconductor is considered. The method involves the creation of a mask on the blank substrate and, upon deposition of YBCO, the superconducting elements are formed in preset local windows of the mask with isolation regions formed between them. Such growth conditions allow the fabrication of micron-size superconducting elements with excellent electrophysical parameters and a smooth su-rface. The influence of the parameters of the master mask of amorphous cerium oxide on the isolating properties of the resulting isolation regions during the fabrication of planar structures on sapphire and cubic zirconia substrates with epitaxial cerium oxide sublayers has been studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amplitude versus phase effects in extreme ultraviolet lithography mask scattering and imaging

It is well established that extreme ultraviolet (EUV) mask multilayer roughness leads to wafer-plane linewidth roughness (LWR) in the lithography process. Analysis and modeling done to date has assumed, however, that the roughness leading to scatter is primarily a phase effect and that the amplitude can be ignored. Under this assumption, simple scattering measurements can be used to characterize the statistical properties of the mask roughness. Here, we explore the implications of this simplifying assumption by modeling the imaging impacts of the roughness amplitude component as a function of the balance between amplitude and phase induced scatter. In addition to model-based analysis, we also use an EUV microscope to compare experimental through focus data to modeling in order to assess the actual amount of amplitude roughness on a typical EUV multilayer mask. The results indicate that amplitude roughness accounts for less than 1% of the total scatter for typical EUV masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Classified channel masks of the East River, Colorado, U.S.A and areas of floodplain erosion and accretion ranging from 1955 to 2015

This dataset provides four sets of geotiffs used for the mapping and analysis an alluvial floodplain reach of the East River, downstream of Gothic, CO, U.S.A near Crested Butte. The files include binary masks of the river channel at five in intervals from 1955 to 2015. Another set of rasters provide a map of the channel centerline pixels of the river for each date. Also included in the dataset are rasters of the areas of channel change due to migration over 8 time intervals. The masks were generated from aerial and satellite imagery collected on seven dates over a sixty-year timespan: 1955, 1973, 1983, 1990, 2001, 2011, and 2015. The masks were analyzed using the Spatially Continuous Riverbank Erosion and Accretion Measurements (SCREAM) software detailed in Rowland et al. 2016 to create the channel centerlines and the change area rasters. The change masks were generated for the following time periods: 1955-1973; 1955-2015; 1973-1983; 1983-1990; 1990-2001; 2001-2011; 2001-2015; and 2011-2015.

54 ENVIRONMENTAL SCIENCES↗

Masked Photocathode for Photoinjector

In this research note, we propose a scheme to insert a photocathode inside a photoinjector for generating high brightness electron beam. Instead of mounting the photocathode onto the electrode, a masked electrode with small hole is used to shield the photocathode from the accelerating vacuum chamber. Using such a masked photocathode will make the replacement of photocathode material very simple by rotating the photocathode behind the mask into the hole. This will significantly increase the usage lifetime of a photocathode. Furthermore, this also helps reduce the dark current or secondary electron emission from the photocathode. The hole on the mask also provides a transverse cut-off to the Gaussian laser profile which can be beneficial from the beam dynamics point of view.

43 PARTICLE ACCELERATORS↗