Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

All-optical, Microwave-free NV-Diamond Magnetometer for Weak Magnetic Field Environments

Sensitive nitrogen-vacancy (NV) magnetometry typically requires a bias field to lift the spin level degeneracy and has commonly utilized microwave sources to selectively manipulate the sensor's spin state. However, this external bias field and microwave sources may perturb the sample of interest or be incompatible with operational conditions. Here, we demonstrate an all-optical, microwave-free NV-diamond magnetometer in the presence of weak or no bias magnetic field (<20 G). We experimentally measure photoluminescence spectra using diamonds with varying NV concentrations; and numerically simulate matching features due to cross-relaxation between NVs. Our results pave the way towards a sensitive probe to study magnetic systems that can be disrupted by microwave signals and can only tolerate weak bias magnetic field.

Ung, Kristine↗

All-optical, Microwave-free NV-Diamond Magnetometer for High Magnetic Field Environment

Nitrogen vacancy (NV) magnetometry has commonly utilized microwave sources to manipulate the sensor's spin state. However, this technique becomes technically challenging under an environment with a Tesla-scale magnetic field or extreme conditions that prohibit the usage of microwave. By leveraging the effect that an off-axis magnetic field to the NV axis quenches its emitted photoluminescence, we present an all-optical, microwave-free broadband quantum diamond magnetometer. We demonstrate magnetic sensing over an extended bias magnetic field range — beyond the ground-state level anti-crossing (GSLAC) region — with a more integrated design.

Zheng, Xiechen↗

High-Field Quantum Diamond Magnetometers for Fusion Diagnostics (Final Technical Report)

Summary of research performed to enable all-optical quantum diamond magnetometers for fusion diagnostics, including: the physical mechanisms enabling all-optical photoluminescence contrast as a function of magnetic field magnitude and direction for dense ensembles of nitrogen vacancy (NV) centers in diamond; the characterization and optimization of NV-diamond material; and related investigations and student training.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atomic magnetometer

An atomic magnetometer is disclosed which uses a pump light beam at a D1 or D2 transition of an alkali metal vapor to magnetically polarize the vapor in a heated cell, and a probe light beam at a different D2 or D1 transition to sense the magnetic field via a polarization rotation of the probe light beam. The pump and probe light beams are both directed along substantially the same optical path through an optical waveplate and through the heated cell to an optical filter which blocks the pump light beam while transmitting the probe light beam to one or more photodetectors which generate electrical signals to sense the magnetic field. The optical waveplate functions as a quarter waveplate to circularly polarize the pump light beam, and as a half waveplate to maintain the probe light beam linearly polarized.

47 OTHER INSTRUMENTATION↗

Optical atomic magnetometer

An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.

47 OTHER INSTRUMENTATION↗

Optically transduced MEMS magnetometer

MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

47 OTHER INSTRUMENTATION↗

Optical atomic magnetometer

An optical atomic magnetometers is provided operating on the principles of nonlinear magneto-optical rotation. An atomic vapor is optically pumped using linearly polarized modulated light. The vapor is then probed using a non-modulated linearly polarized light beam. The resulting modulation in polarization angle of the probe light is detected and used in a feedback loop to induce self-oscillation at the resonant frequency.

43 PARTICLE ACCELERATORS↗

Atomic magnetometer with multiple spatial channels

An atomic magnetometer includes an atomic vapor cell, an optical system conformed to transmit pump radiation and probe radiation through the vapor cell, and an optical detection system arranged to receive and detect probe radiation after it exits the vapor cell. Improvements in the separation of spatial channels are achieved by using a a diffractive optical element arranged to divide at least the pump radiation into a plurality of separate diffracted beams that traverse the vapor cell.

47 OTHER INSTRUMENTATION↗

Deployment of magnetometers to monitor stray magnetic fields near the PROSPECT detector

PROSPECT is a reactor antineutrino experiment located in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. PROSPECT’s primary goals are to probe short-baseline oscillations and perform a precise measurement of the U-235 reactor antineutrino spectrum. The detector consists of 154 segmented cells filled with 6Li-doped liquid scintillator. Each segment holds two PMTs, one on each end of the cell. The PMTs can be exposed to stray magnetic fields from superconducting magnets operating on the experiment hall one floor below the detector. The monitoring of the magnetic fields is an important part of our background characterization as the magnetic fields can directly influence the energy measurement. This study presents the characterization and monitoring of stray magnetic fields using triple axis magnetometers near the detector.

Gilbert, Corey E.↗

Micro-imaging with an atomic magnetometer and flux guide

Micro-imaging may be performed with an ultra-sensitive atomic magnetometer (AM) and an array of flux guides (FGs). The array of FGs may be configured to act as a magnetic lens that expands microscopic magnetic distribution to match dimensions of the AM. A plurality of single channel AMs may be combined into an array, or the AM may include an array of photodetectors, to realize multi-channel operation.

47 OTHER INSTRUMENTATION↗

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment’s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]↗

Nanoscale magnetic field mapping with a single spin scanning probe magnetometer

We demonstrate quantitative magnetic field mapping with nanoscale resolution, by applying a lock-in technique on the electron spin resonance frequency of a single nitrogen-vacancy defect placed at the apex of an atomic force microscope tip. In addition, we report an all-optical magnetic imaging technique which is sensitive to large off-axis magnetic fields, thus extending the operation range of diamond-based magnetometry. Both techniques are illustrated by using a magnetic hard disk as a test sample. Owing to the non-perturbing and quantitative nature of the magnetic probe, this work should open up numerous perspectives in nanomagnetism and spintronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗