Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact of Resonant Magnetic Perturbations on the Toroidal Location of the Runaway Electron Final Loss Strike Point

It is demonstrated that the peak toroidal impact phase of the post-disruption runaway electrons (REs) can be varied shot-to-shot by means of applied static non-axisymmetric (3D) magnetic fields, or resonant magnetic perturbations (RMPs). In the experiments, high-current (500 kA), purged RE plateaus (i.e. low impurity post-disruption plasmas with current carried completely by REs) were terminated on the DIII-D tokamak center post (CP). The global toroidal impact peak of the REs appears to be dominantly set by the toroidal phase of a wall-locked tearing mode, typically (m/n) = (2/1), but sometimes (m/n) = (3/2). In the absence of external RMP, the locked mode reliably locks close to a preferred toroidal phase Φ ≃ 75◦ probably set by intrinsic error fields. With applied RMP, the locked mode and RE impact phase is pushed to a new location. When the tearing mode is (m/n) = (2/1), the phase is well controlled and tracks the applied RMP phase, but in the case of an (m/n) = (3/2) tearing mode, the new phase location is not well controlled. These results could have application in ITER and other fusion power plant (FPP) - sized tokamaks as a method for spreading disruption first wall damage from REs

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range

In several low-field Nuclear Magnetic Resonance (LF-NMR) and surface nuclear magnetic resonance applications, i.e., in the frequency range of kHz, high sensitivity magnetic field detectors are needed. Usually, low-T{sub c} superconducting quantum interference devices (SQUIDs) with a high field sensitivity of about 1 fT/Hz{sup 1/2} are employed as detectors. Considering the flux trapping and operational difficulties associated with low-T{sub c} SQUIDs, we designed and fabricated liquid-nitrogen-cooled Cu coils for NMR detection in the kHz range. A cooled coil system consisting of a 9-cm diameter Cu coil and a low noise preamplifier was systematically investigated and reached a sensitivity of 2 fT/Hz{sup 1/2} at 77 K, which is 3 times better compared to the sensitivity at 300 K. A Q-switch circuit as an essential element for damping the ringing effects of the pickup coil was developed to acquire free induction decay signals of a water sample with minimum loss of signal. Our studies demonstrate that cooled Cu coils, if designed properly, can provide a comparable sensitivity to low-T{sub c} SQUIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of toroidal torque by non-resonant magnetic perturbations in tokamaks for resonant transport regimes using a Hamiltonian approach

Toroidal torque generated by neoclassical viscosity caused by external non-resonant, non-axisymmetric perturbations has a significant influence on toroidal plasma rotation in tokamaks. In this article, a derivation for the expressions of toroidal torque and radial transport in resonant regimes is provided within quasilinear theory in canonical action-angle variables. The proposed approach treats all low-collisional quasilinear resonant neoclassical toroidal viscosity regimes including superbanana-plateau and drift-orbit resonances in a unified way and allows for magnetic drift in all regimes. It is valid for perturbations on toroidally symmetric flux surfaces of the unperturbed equilibrium without specific assumptions on geometry or aspect ratio. The resulting expressions are shown to match the existing analytical results in the large aspect ratio limit. Numerical results from the newly developed code NEO-RT are compared to calculations by the quasilinear version of the code NEO-2 at low collisionalities. The importance of the magnetic shear term in the magnetic drift frequency and a significant effect of the magnetic drift on drift-orbit resonances are demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of signal-to-noise ratio in the in vivo{sup 31}P magnetic resonance spectra of the human brain

The main problem in {sup 31}P magnetic resonance spectroscopy is a low signal-to-noise ratio (SNR) of spectra acquired with clinical magnetic resonance imaging (MRI) scanners. Using spin-spin phosphorus-proton ({sup 31}P-{sup 1}H) decoupling and heteronuclear Overhauser effect and taking into account the effect of the longitudinal relaxation time T{sub 1} on the SNR, the method for localization and excitation of the region of interest (Image Selected in vivo Spectroscopy pulse sequence) was optimized to increase the SNR in the {sup 31}P magnetic resonance spectra of the human brain to ~50% without increasing signal acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Roadmap on nanoscale magnetic resonance imaging

Abstract The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

Budakian, Raffi↗

Identification of preferred multimodal ligand‐binding regions on IgG1 F C using nuclear magnetic resonance and molecular dynamics simulations

Abstract In this study, the binding of multimodal chromatographic ligands to the IgG1 F C domain were studied using nuclear magnetic resonance and molecular dynamics simulations. Nuclear magnetic resonance experiments carried out with chromatographic ligands and a perdeuterated 15 N‐labeled F C domain indicated that while single‐mode ion exchange ligands interacted very weakly throughout the F C surface, multimodal ligands containing negatively charged and aromatic moieties interacted with specific clusters of residues with relatively high affinity, forming distinct binding regions on the F C . The multimodal ligand‐binding sites on the F C were concentrated in the hinge region and near the interface of the C H 2 and C H 3 domains. Furthermore, the multimodal binding sites were primarily composed of positively charged, polar, and aliphatic residues in these regions, with histidine residues exhibiting some of the strongest binding affinities with the multimodal ligand. Interestingly, comparison of protein surface property data with ligand interaction sites indicated that the patch analysis on F C corroborated molecular‐level binding information obtained from the nuclear magnetic resonance experiments. Finally, molecular dynamics simulation results were shown to be qualitatively consistent with the nuclear magnetic resonance results and to provide further insights into the binding mechanisms. An important contribution to multimodal ligand‐F C binding in these preferred regions was shown to be electrostatic interactions and π–π stacking of surface‐exposed histidines with the ligands. This combined biophysical and simulation approach has provided a deeper molecular‐level understanding of multimodal ligand–F C interactions and sets the stage for future analyses of even more complex biotherapeutics.

Gudhka, Ronak B.↗

The Effect of the Polarization Characteristics of Probe Light on the Signal of Optically Detected Magnetic Resonance in Magnetometric and Gyroscopic Quantum Sensors

We consider the effect of the polarization characteristics of probe light on the signal of optically detected magnetic resonance in quantum sensors, including quantum magnetometers based on the phenomenon of electron paramagnetic resonance and quantum gyroscopes employing both the electron and nuclear magnetic resonance. Relationships between the magnetic resonance signal magnitude and parameters of the optical system elements, which are based on the Stokes–Mueller formalism, are derived and verified. It is found that the main destructive influence in the signal in a standard two-beam scheme is produced by phase delays introduced by both metallic and dielectric mirrors. Methods for compensation of this destructive influence are proposed and verified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Contributed Review: Nuclear magnetic resonance core analysis at 0.3 T

Nuclear magnetic resonance (NMR) provides a powerful toolbox for petrophysical characterization of reservoir core plugs and fluids in the laboratory. Previously, there has been considerable focus on low field magnet technology for well log calibration. Now there is renewed interest in the study of reservoir samples using stronger magnets to complement these standard NMR measurements. Here, the capabilities of an imaging magnet with a field strength of 0.3 T (corresponding to 12.9 MHz for proton) are reviewed in the context of reservoir core analysis. Quantitative estimates of porosity (saturation) and pore size distributions are obtained under favorable conditions (e.g., in carbonates), with the added advantage of multidimensional imaging, detection of lower gyromagnetic ratio nuclei, and short probe recovery times that make the system suitable for shale studies. Intermediate field instruments provide quantitative porosity maps of rock plugs that cannot be obtained using high field medical scanners due to the field-dependent susceptibility contrast in the porous medium. Example data are presented that highlight the potential applications of an intermediate field imaging instrument as a complement to low field instruments in core analysis and for materials science studies in general.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing Field Distortion in Magnetic Resonance Imaging

A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

Eom, Byeong Ho↗

Magnetic structure of Nd in NdFeAsO studied by x-ray resonant magnetic scattering

The magnetic structure of Nd in NdFeAsO compound has been explored by x-ray resonant magnetic scattering at the Nd L 2 edge ( E = 6.725 keV) at 1.7 ≤ T ≤ 15 K. At T = 1.7 K we find that the Nd moments are aligned along the crystallographic c direction with the (1, 0, 0) propagation vector, and are arranged antiferromagnetically along the a direction and ferromagnetically along the b and c directions. At 1.7 < T ≤ 15 K, we observe an unusual temperature dependence of the magnetic Bragg peaks that appear differently at Q = ( h , 0 , l ) and ( 0 , k , l ) . From the changes of magnetic intensities and our representation analysis, we find that the Nd moments are reoriented toward the a direction with a gradual decrease of the moment component in the c direction with increasing temperature. We postulate that the reorientation of the Nd moment is due to a strong interplay with the Fe moment which is fully ordered in this temperature range.

36 MATERIALS SCIENCE↗

Anvil cell gasket design for high pressure nuclear magnetic resonance experiments beyond 30 GPa

Nuclear magnetic resonance (NMR) experiments are reported at up to 30.5 GPa of pressure using radiofrequency (RF) micro-coils with anvil cell designs. These are the highest pressures ever reported with NMR, and are made possible through an improved gasket design based on nano-crystalline powders embedded in epoxy resin. Cubic boron-nitride (c-BN), corundum (α-Al{sub 2}O{sub 3}), or diamond based composites have been tested, also in NMR experiments. These composite gaskets lose about 1/2 of their initial height up to 30.5 GPa, allowing for larger sample quantities and preventing damages to the RF micro-coils compared to precipitation hardened CuBe gaskets. It is shown that NMR shift and resolution are less affected by the composite gaskets as compared to the more magnetic CuBe. The sensitivity can be as high as at normal pressure. The new, inexpensive, and simple to engineer gaskets are thus superior for NMR experiments at high pressures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The morphology of C–S–H: Lessons from {sup 1}H nuclear magnetic resonance relaxometry

{sup 1}H nuclear magnetic resonance has been applied to cement pastes, and in particular calcium silicate hydrate (C–S–H), for the characterisation of porosity and pore water interactions for over three decades. However, there is now renewed interest in the method, given that it has been shown to be non-invasive, non-destructive and fully quantitative. It is possible to make measurements of pore size distribution, specific surface area, C–S–H density and water fraction and water dynamics over 6 orders of magnitude from nano- to milli-seconds. This information comes in easily applied experiments that are increasingly well understood, on widely available equipment. This contribution describes the basic experiments for a cement audience new to the field and reviews three decades of work. It concludes with a summary of the current state of understanding of cement pore morphology from the perspective of {sup 1}H NMR.

36 MATERIALS SCIENCE↗

Effects of hydrogenation on non-radiative defects in GaNP and GaNAs alloys: An optically detected magnetic resonance study

Photoluminescence and optically detected magnetic resonance techniques are utilized to study defect properties of GaNP and GaNAs alloys subjected to post-growth hydrogenation by low-energy sub-threshold ion beam irradiation. It is found that in GaNP H incorporation leads to activation of new defects, which has a Ga interstitial (Ga{sub i}) atom at its core and may also involve a H atom as a partner. The observed activation critically depends on the presence of N in the alloy, as it does not occur in GaP with a low level of N doping. In sharp contrast, in GaNAs hydrogen is found to efficiently passivate Ga{sub i}-related defects present in the as-grown material. A possible mechanism responsible for the observed difference in the H behavior in GaNP and GaNAs is discussed.

36 MATERIALS SCIENCE↗

Effect of Gold Marker Seeds on Magnetic Resonance Spectroscopy of the Prostate

Purpose: Magnetic resonance stereoscopic imaging (MRSI) of the prostate is an emerging technique that may enhance targeting and assessment in radiotherapy. Current practices in radiotherapy invariably involve image guidance. Gold seed fiducial markers are often used to perform daily prostate localization. If MRSI is to be used in targeting prostate cancer and therapy assessment, the impact of gold seeds on MRSI must be investigated. The purpose of this study was to quantify the effects of gold seeds on the quality of MRSI data acquired in phantom experiments. Methods and Materials: A cylindrical plastic phantom with a spherical cavity 10 centimeters in diameter wss filled with water solution containing choline, creatine, and citrate. A gold seed fiducial marker was put near the center of the phantom mounted on a plastic stem. Spectra were acquired at 1.5 Tesla by use of a clinical MRSI sequence. The ratios of choline + creatine to citrate (CC/Ci) were compared in the presence and absence of gold seeds. Spectra in the vicinity of the gold seed were analyzed. Results: The maximum coefficient of variation of CC/Ci induced by the gold seed was found to be 10% in phantom experiments at 1.5 T. Conclusion: MRSI can be used in prostate radiotherapy in the presence of gold seed markers. Gold seeds cause small effects (in the order of the standard deviation) on the ratio of the metabolite's CC/Ci in the phantom study done on a 1.5-T scanner. It is expected that gold seed markers will have similar negligible effect on spectra from prostate patients. The maximum of 10% of variation in CC/Ci found in the phantom study also sets a limit on the threshold accuracy of CC/Ci values for deciding whether the tissue characterized by a local spectrum is considered malignant and whether it is a candidate for local boost in radiotherapy dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operando nuclear magnetic resonance rotor insert

A magic angle sample spinning nuclear magnetic resonance system including a housing, a cryogenic fluid in the housing, a magnet in the housing, a probe in the housing, a magic angle sample spinning insert in the probe, a sample battery in the magic angle sample spinning insert, a photovoltaic cell in the magic angle sample spinning insert wherein the photovoltaic cell is connected to the sample battery, an optic fiber operatively connected to the photovoltaic cell, and a laser operatively connected to the optic fiber wherein the laser provides power to charge the sample battery during the magic angle sample spinning nuclear magnetic resonance.

Marple, Maxwell↗

A 4 K cryogenic probe for use in magnetic resonance force microscopy experiments

The detailed design of a mechanically detected nuclear magnetic resonance probe using the SPAM (Springiness Preservation by Aligning Magnetization) geometry, operating at 4 K, in vacuum, and a several-Tesla magnetic field is described. The probe head is vibration-isolated well enough from the environment by a three-spring suspension system that the cantilever achieves thermal equilibrium with the environment without the aid of eddy current damping. The probe uses an ultra-soft Si cantilever with a Ni sphere attached to its tip, and magnetic resonance is registered as a change in the resonant frequency of the driven cantilever. The RF system uses frequency sweeps for adiabatic rapid passage using a 500 μm diameter RF coil wound around a sapphire rod. The RF coil and optical fiber of the interferometer used to sense the cantilever's position are both located with respect to the cantilever using a Garbini micropositioner, and the sample stage is mounted on an Attocube nanopositioner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗