Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MAGNETIC PUMPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

CAWSES November 7-8, 2004, Superstorm: Complex Solar and Interplanetary Features in the Post-Solar Maximum Phase

The complex interplanetary structures during 7 to 8 Nov 2004 are analyzed to identify their properties as well as resultant geomagnetic effects and the solar origins. Three fast forward shocks, three directional discontinuities and two reverse waves were detected and analyzed in detail. The three fast forward shocks 'pump' up the interplanetary magnetic field from a value of approx.4 nT to ~44 nT. However, the fields after the shocks were northward, and magnetic storms did not result. The three ram pressure increases were associated with major sudden impulses (SI + s) at Earth. A magnetic cloud followed the third forward shock and the southward Bz associated with the latter was responsible for the superstorm. Two reverse waves were detected, one at the edge and one near the center of the magnetic cloud (MC). It is suspected that these 'waves' were once reverse shocks which were becoming evanescent when they propagated into the low plasma beta MC. The second reverse wave caused a decrease in the southward component of the IMF and initiated the storm recovery phase. It is determined that flares located at large longitudinal distances from the subsolar point were the most likely causes of the first two shocks without associated magnetic clouds. It is thus unlikely that the shocks were 'blast waves' or that magnetic reconnection eroded away the two associated MCs. This interplanetary/solar event is an example of the extremely complex magnetic storms which can occur in the post-solar maximum phase.

solar flares

Online Oxide Contamination Measurement and Purification Demonstration

Liquid metal sodium-potassium (NaK) has advantageous thermodynamic properties indicating its use as a fission reactor coolant for a surface (lunar, martian) power system. A major area of concern for fission reactor cooling systems is system corrosion due to oxygen contaminants at the high operating temperatures experienced. A small-scale, approximately 4-L capacity, simulated fission reactor cooling system employing NaK as a coolant was fabricated and tested with the goal of demonstrating a noninvasive oxygen detection and purification system. In order to generate prototypical conditions in the simulated cooling system, several system components were designed, fabricated, and tested. These major components were a fully-sealed, magnetically-coupled mechanical NaK pump, a graphite element heated reservoir, a plugging indicator system, and a cold trap. All system components were successfully demonstrated at a maximum system flow rate of approximately 150 cc/s at temperatures up to 550 C. Coolant purification was accomplished using a cold trap before and after plugging operations which showed a relative reduction in oxygen content.

Bradley, D. E.

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee

Automating the Study of Microbial Adaptation Dynamics on and off the ISS

The International Space Station (ISS) not only serves as a unique environment for humans, but also the microorganisms that join alongside. Many microbes present on the spacecraft arrive via humans, and as they interact with different surfaces they begin to inhabit those locations. Much like how human health has shown to be impacted by these extreme environments, microbial viability and response to stress also changes. Experimental evolution (EE) can aid in studying how microbes’ growth and activity changes within the ISS environments by applying controlled stressors to microbial cultures and monitoring their response over generations. EE studies are commonly done manually in laboratories, but, with multiple environmental variables to measure and adjust, it becomes highly labor-intensive, prone to human error, and challenging to scale. A multipurpose automated EE system named the AADEC has been developed to address these problems. This system integrates multiple sensors into a single fluidic chamber using UV-C flux, temperature, and media composition as stressors. AADEC contains five sensors: oxidation-reduction potential, electrical conductivity, pH, dissolved oxygen, and optical density. On their own, each is able to provide certain information on growth rate or metabolism; together, they show in detail how stressors affect life. AADEC studies can be conducted on Earth and repeated aboard the ISS to see how behavior changes when exposed to space mission stressors such as microgravity and radiation. AADEC’s auxiliary systems include peristaltic pumps for media exchange, magnetic rods for agitation, and a Raspberry Pi microprocessor to monitor, store, and adjust stressor levels real-time. This allows researchers to gather information within rapid generations, data and accuracy which is challenging to achieve through manual studies. With further miniaturization and automation, such as a more robust single-piece fluidics card, AADEC has the potential to be developed as a spacecraft payload. Support: NASA Ames CIF Award

Automating

Enhanced spin pumping in heterostructures of coupled ferrimagnetic garnets

Spin pumping has significant implications for spintronics, providing a mechanism to manipulate and transport spins for information processing. Understanding and harnessing spin currents through spin pumping is critical for the development of efficient spintronic devices. The use of a magnetic insulator with low damping enhances the signal-to-noise ratio in crucial experiments such as spin-torque ferromagnetic resonance (FMR) and spin pumping. A magnetic insulator coupled with a heavy metal or quantum material offers a more straightforward model system, especially when investigating spin-charge interconversion processes to greater accuracy. This simplicity arises from the absence of unwanted effects caused by conduction electrons unlike in ferromagnetic metals. Here, we investigate the spin pumping in coupled ferrimagnetic (FiM) Y 3 Fe 5 O 12 (YIG)/Tm 3 Fe 5 O 12 (TmIG) bilayers combined with heavy-metal (Pt) using the inverse spin Hall effect. It is observed that magnon transmission occurs at both of the FiMs FMR positions. The enhancement of spin pumping voltage (V sp ) in the FiM garnet heterostructures is observed. The plausible reason might be the interfacial exchange coupling between FiMs. The modulation of V sp is achieved by tuning the bilayer structure. Further, the spin mixing conductance for these coupled systems is found to be ≈ 10 18 m –2 . Furthermore, our findings describe a coupled FiM system for the investigation of magnon coupling providing opportunities for magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Preliminary design of a Primary Loop Pump Assembly (PLPA), using electromagnetic pumps

A preliminary design study of flight-type dc conduction-permanent magnetic, ac helical induction, and ac linear induction pumps for circulating 883 K (1130 F) NaK at 9.1 kg/sec (20 lb/sec) is described. Various electromagnetic pump geometrics are evaluated against hydraulic performance, and the effects of multiple windings and numbers of pumps per assembly on overall reliability were determined. The methods used in the electrical-hydraulic, stress, and thermal analysis are discussed, and the high temperature electrical materials selected for the application are listed.

Moss, T. A.

Rotary blood pump

A blood pump that comprises a pump housing having a blood flow path therethrough, a blood inlet, and a blood outlet; a stator mounted to the pump housing, the stator having a stator field winding for producing a stator magnetic field; a flow straightener located within the pump housing, and comprising a flow straightener hub and at least one flow straightener blade attached to the flow straightener hub; a rotor mounted within the pump housing for rotation in response to the stator magnetic field, the rotor comprising an inducer and an impeller; the inducer being located downstream of the flow straightener, and comprising an inducer hub and at least one inducer blade attached to the inducer hub; the impeller being located downstream of the inducer, and comprising an impeller hub and at least one impeller blade attached to the impeller hub; and preferably also comprising a diffuser downstream of the impeller, the diffuser comprising a diffuser hub and at least one diffuser blade. Blood flow stagnation and clot formation within the pump are minimized by, among other things, providing the inducer hub with a diameter greater than the diameter of the flow straightener hub; by optimizing the axial spacing between the flow straightener hub and the inducer hub, and between the impeller hub and the diffuser hub; by optimizing the inlet angle of the diffuser blades; and by providing fillets or curved transitions between the upstream end of the inducer hub and the shaft mounted therein, and between the impeller hub and the shaft mounted therein.

Benkowski, Robert J.

Growth and characterization of ferromagnetic Ga 2 O 3 :(Cr, Mn)

The goal of this Exploratory Express project was to explore the possibility of tunable ferromagnetism in Mn or Cr incorporated epitaxial Ga 2 O 3 films. Tunability of magnetic properties can enable novel applications in spintronics, quantum computing, and magnetism-based logics by allowing control of magnetism down to the nanoscale. Carriers (electrons or holes) mediated ferromagnetic ordering in semiconductor can lead to tunable ferromagnetism by leveraging the tunability of carrier density with doping level, gate electric field, or optical pumping of the carriers. The magnetic ions (Cr or Mn) in Ga 2 O 3 act as localized spin centers which can potentially be magnetically coupled through conduction electrons to enable ferromagnetic ordering. Here we investigated tunable ferromagnetism in beta Ga 2 O 3 semiconductor host with various n-doping levels by incorporating 2.4 atomic percent Mn or Cr. The R&D approach involved growth of epitaxial Ga 2 O 3 film on sapphire or Ga 2 O 3 substrate, implantation of Mn or Cr ions, annealing of the samples post implantation, and magnetic measurements. We studied magnetic behavior of Mn:Ga 2 O 3 as a function of different n-doping levels and various annealing temperatures. The vibrating sample magnetometry (VSM) measurement exhibited strong ferromagnetic signals from the annealed Mn:Ga 2 O 3 sample with n-doping level of 5E19 cm -3 . This ferromagnetic behavior disappears from Mn:Ga 2 O 3 when the n-doping level is reduced to 5E16 cm -3 . Although these results are to be further verified by other measurement schemes due to the observation of background ferromagnetism from the growth substrate, these results indicate the possibility of tunable ferromagnetism in Mn:Ga 2 O 3 mediated by conduction electrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James

Advances in cryogenic engineering. Vols. 35A & 35B - Proceedings of the 1989 Cryogenic Engineering Conference, University of California, Los Angeles, July 24-28, 1989

The book presents a review of literature on superfluid helium, together with papers under the topics on heat and mass transfer in He II; applications of He II for cooling superconducting devices in space; heat transfer to liquid helium and liquid nitrogen; multilayer insulation; applications of superconductivity, including topics on magnets and other devices, magnet stability and coil protection, and cryogenic techniques; and refrigeration for electronics. Other topics discussed include refrigeration of superconducting systems; the expanders, cold compressors, and pumps for liquid helium; dilution refrigerators; magnetic refrigerators; pulse tube refrigerators; cryocoolers for space applications; properties of cryogenic fluids; cryogenic instrumentation; hyperconducting devices (cryogenic magnets); cryogenic applications in space science and technology and in transportation; and miscellaneous cryogenic techniques and applications.

Fast, R. W.

The practical use of magnetic cooling

Paramagnetic cycles for low temperature superconducting magnet cooling, discussing refrigerator, cryogenic pumps, regenerators and adjustable heat source and sink

Brown, G. V.

NASA atomic hydrogen standards program - An update

Some of the design features of NASA hydrogen masers are discussed including the large hydrogen source bulb, the palladium purified, the state selector, the replaceable pumps, the small entrance stem, magnetic shields, the elongated storage bulb, the aluminum cavity, the electronics package, and the autotuner. Attention is also given to the reliability and operating life of these hydrogen atomic standards.

Reinhardt, V. S.

Independent gain and bandwidth control of a traveling wave maser

An X-band traveling wave maser of the folded-comb type is presented, with two figure-eight coils for gain and bandwidth control. One figure-eight coil covers the full lengths of the comb structure for bandwidth adjustment of an external magnetic field. The other coil covers a central half of the comb structure for independent gain adjustment of the external magnetic field. The half of each figure-eight coil at the turn around end of the comb structure is oriented to aid the external magnetic field, and the half of each coil at the input-output end of the comb structure is oriented to buck the external magnetic field. The maser is pumped in the push-push mode with two different frequencies.

Trowbridge, D. L.

Interstellar bullets - H2O masers and Herbig-Haro objects

The paper considers the energy input to H2O masers in a dense molecular cloud and analyzes the response time scales for both collisional and radiative pump models. Specific mechanisms for magnetic energy input are given. The evolution of dense H2O maser clouds is studied in the environment of a young pre-main-sequence star that has developed an appreciable supersonic wind. It is shown that compact clouds can be ejected at high velocity to distances of order 1 pc. It is suggested that these clouds (referred to as interstellar bullets) might explain the phenomena of Herbig-Haro objects and high-velocity gas motions observed near compact infrared objects.

Norman, C.

X-band, low-noise, traveling-wave maser

The development and performance of X-band traveling-wave maser (TWM) systems with effective input noise temperature of 3.5 K and bandwidths varying from 65 to 108 MHz is discussed. These TWMs are used on the 64-meter antennas at Deep Space Stations 14, 43 and 63 at 8420 MHz to meet the requirements of the Voyager-Saturn encounter. The TWMs use shortened and cooled signal input waveguide to reduce noise and are equipped with superconducting magnets and solid-state pump sources to provide the required stability performance.

Trowbridge, D. L.

Magnetospheric dynamo processes

Three processes are examined whereby an effective electromotive force and energy input arise in circuits of magnetospheric currents, even in the absence of time-varying magnetic fields. The first involves currents on 'open' field lines, linking the ionosphere with the solar wind, and it underscores the role of polarization currents. The second may exist on the current filament observed in the vicinity of Jupiter's satellite Io. The third may operate along the high-latitude boundary of the earth's magnetic tail, from where it pumps energy into the plasma sheet.

Stern, D. P.

Reciprocating magnetic refrigerator employing tandem porous matrices within a reciprocating displacer

Disclosed is a method and apparatus for a magnetic refrigeration system. A continuously reciprocating displacer houses at least a pair of paramagnetic substances each of which is alternately driven into and out of a magnetic field. Two separate bidirectional pumping systems flow helium gas through the displacer and through both paramagnetic substances to create heat exchange conditions at two separate temperature extremes.

Johnson, D. L.