Low two-level-system noise in hydrogenated amorphous silicon

At sub-Kelvin temperatures, two-level systems (TLSs) present in amorphous dielectrics source a permittivity noise, degrading the performance of a wide range of devices using superconductive resonators such as qubits or kinetic inductance detectors. We report here on measurements of TLS noise in hydrogenated amorphous silicon (a-Si:H) films deposited by plasma-enhanced chemical vapor deposition in superconductive lumped element resonators using parallel-plate capacitors. In conclusion, the TLS noise results presented in this article for two recipes of a-Si:H improve on the best results achieved in the literature by a factor >5 for a-Si:H and other amorphous dielectrics and are comparable to those observed for resonators deposited on crystalline dielectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Development of a High-Resolution, Single-Photon X-Ray Detector

Research on the development of a low-temperature, magnetic bolometer for x-ray detection is reported. The principal accomplishments during the first phase of this research are as follows. (1) We have constructed SQUID magnetometers and detected both 122 keV and 6 keV x-rays in relatively larger metallic samples with high quantum efficiency. (2) The magnetic properties of a metal sample with localized paramagnetic spins have been measured and found to agree with theoretical expectations. (3) The size of the magnetic response of the sample to x-rays is in agreement with predictions based on the properties of the sample and sensitivity of the magnetometer, supporting the prediction that a resolution of 1 eV at 10 keV should be achievable.

Seidel, George M.↗

Chemochromic Hydrogen Leak Detectors

At NASA, hydrogen safety is a key concern for space shuttle processing. Leaks of any level must be quickly recognized and addressed due to hydrogen s lower explosion limit. Chemo - chromic devices have been developed to detect hydrogen gas in several embodiments. Because hydrogen is odorless and colorless and poses an explosion hazard, there is an emerging need for sensors to quickly and accurately detect low levels of leaking hydrogen in fuel cells and other advanced energy- generating systems in which hydrogen is used as fuel. The device incorporates a chemo - chromic pigment into a base polymer. The article can reversibly or irreversibly change color upon exposure to hydrogen. The irreversible pigment changes color from a light beige to a dark gray. The sensitivity of the pigment can be tailored to its application by altering its exposure to gas through the incorporation of one or more additives or polymer matrix. Furthermore, through the incorporation of insulating additives, the chemochromic sensor can operate at cryogenic temperatures as low as 78 K. A chemochromic detector of this type can be manufactured into any feasible polymer part including injection molded plastic parts, fiber-spun textiles, or extruded tapes. The detectors are simple, inexpensive, portable, and do not require an external power source. The chemochromic detectors were installed and removed easily at the KSC launch pad without need for special expertise. These detectors may require an external monitor such as the human eye, camera, or electronic detector; however, they could be left in place, unmonitored, and examined later for color change to determine whether there had been exposure to hydrogen. In one type of envisioned application, chemochromic detectors would be fabricated as outer layers (e.g., casings or coatings) on high-pressure hydrogen storage tanks and other components of hydrogen-handling systems to provide visible indications of hydrogen leaks caused by fatigue failures or other failures in those systems. In another type of envisioned application, chemochromic detectors of this type could be optoelectronically instrumented for monitoring to provide measured digital indications of color changes indicative of the presence of hydrogen.

Roberson, Luke↗

Design and Development of the CubeSat Infrared Atmospheric Sounder (CIRAS

The CubeSat Infrared Atmospheric Sounder (CIRAS) is a NASA Earth Science Technology Office (ESTO) sponsored mission to demonstrate key technologies used in very high spectral resolution infrared remote sensing of Earth’s atmosphere from space. CIRAS was awarded under the ESTO In-flight Validation of Earth Science Technologies (InVEST) program in 2015 and is currently under development at NASA JPL with key subsystems being developed by industry. CIRAS incorporates key new instrument technologies including a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The second key technology is an MWIR Grating Spectrometer (MGS) designed to provide imaging spectroscopy for atmospheric sounding in a CubeSat volume. The MGS is under development by Ball Aerospace with the grating and slit developed by JPL. The third key technology is an infrared blackbody fabricated with JPL’s black silicon to have very high emissivity in a flat plate construction. JPL will also develop the mechanical, electronic and thermal subsystems for CIRAS, while the spacecraft will be a 6U CubeSat developed by Blue Canyon Technologies. This paper provides an overview of the design and acquisition approach, and provides a status of the current development.

Vengel, Tony↗

Technology Development in Support of Hyperspectral Infrared Atmospheric Sounding in a CubeSat

Hyperspectral infrared sounding in a CubeSat will provide a new dimension to the current suite of IR sounders by allowing measurements at multiple times of day and enabling formation flying of IR sounders for new data products such as Atmospheric Motion Vector (AMV) winds. This paper focuses on technology development during the CubeSat Infrared Atmospheric Sounder (CIRAS) project sponsored by the NASA Earth Science Technology Office (ESTO), and coincident studies by the NOAA Office of Projects, Planning, and Analysis (OPPA). The CIRAS approach incorporates key new instrument technologies developed at JPL’s Microdevices Lab (MDL) including a 2D array of High Operating Temperature Barrier Infrared Detector (HOT-BIRD) material, selected for its high uniformity, low cost, low noise and higher operating temperatures than traditional materials. The second key technology is an MWIR Grating Spectrometer (MGS) designed by Ball Aerospace with a JPL MDL slit and immersion grating to provide hyperspectral infrared imaging in a CubeSat volume. The third key technology is a blackbody calibration target fabricated with MDL’s black silicon to have very high emissivity in a flat plate construction. JPL has completed design and breadboard of the mechanical, electronic and thermal subsystems for CIRAS payload including a HOT-BIRD FPA, with filters in a dewar and a breadboard of the electronics and scan mirror assembly. Blue Canyon Technologies, developer of the CIRAS 6U CubeSat, completed the Final Design Review for the spacecraft.

Yee, Karl↗

Progress Toward a Compact 0.05 K Magnet Refrigerator Operating from 10 K

Much of the most interesting information regarding our universe is hidden in the sub-millimeter, infrared, and x-rays bands of the spectrum, to which our atmosphere is largely opaque. Thus, missions exploring these bands are a very important part of NASA s Space Science program. Coincidentally, the most sensitive detectors in these spectral regions operate at extremely low temperatures, typically 0.05 - 0.10 K. Generally these temperatures will be achieved using magnetic refrigerators, also know as Adiabatic Demagnetization Refrigerators, or ADRs. Current ADRs, such as the one used in the XRS-II instrument on the Astro-E2 satellite, use a single-stage to cool detectors from 1.3 K to 0.06 K. The ADR is designed so that it can absorb the heat on the detector stage for at least 24 hours before it must stop, warm up to the helium bath temperature (1.3 K), and dump the accumulated heat. Future detector arrays will be much larger and will have higher heat dissipation. Furthermore, future missions will use mechanical cryocoolers to provide upper stage cooling, but they can only reach 4 - 10 K. Trying to scale heavy (-15 kg) single stage ADRs up to the higher heat loads and higher heat rejection temperatures required leads to unacceptably large systems. The GSFC Cryogenics Branch has developed the Continuous ADR (CADR) to solve this problem. The CADR consists of a series of ADR stages that sequentially pass heat from the load up to the high temperature heat sink. The stage connected to the load remains at a constant temperature. The continuous stage effectively decouples detector operation from ADR operation, allowing the ADR stages to be cycled much more rapidly. Rapid cycling leads to higher cooling power density. The cascading, multistage arrangement allows the magnetic refrigerant of each stage to be optimized for its own temperature swing. In the past year, we have made good progress toward a 0.05 to 10K system. A four-stage system that operates from 4.2 K was demonstrated. Magnetic shielding was added to eliminate inter-stage coupling. Improvements were made to superconducting and passive gas-gap heat switches. A second type of passive gas gap switch, one meant for use at higher temperature, was demonstrated. The presentation will focus primarily on these recent design improvements, and on the challenges that remain on the progress toward a system that will operate from 10 K or higher.

Canavan, Edgar↗

Cryogenic and low temperature heat pipe/cooler studies for spacecraft application

The prime purpose of the present work is to examine cryogenic heat pipe/cooler feasibility in the 80 to 100 K temperature range and in the regimes of operation required for NASA spacecraft. Present requirements within these regimes are (1) cooling load of less than 1 to 2 watt per cooler, (2) small detector/heat pipe interface area, and (3) high system reliability and long lifetime operations. The cooling capacity of practical radiant coolers is very low in this temperature range, and very temperature sensitive. Detector performance is also strongly dependent on temperatures in this regime. It is, therefore important to understand the interplay of the heat pipe and its effects on overall system performance.

Sherman, A.↗

NASA Tech Briefs, October 2004

Topics include: Relative-Motion Sensors and Actuators for Two Optical Tables; Improved Position Sensor for Feedback Control of Levitation; Compact Tactile Sensors for Robot Fingers; Improved Ion-Channel Biosensors; Suspended-Patch Antenna With Inverted, EM-Coupled Feed; System Would Predictively Preempt Traffic Lights for Emergency Vehicles; Optical Position Encoders for High or Low Temperatures; Inter-Valence-Subband/Conduction-Band-Transport IR Detectors; Additional Drive Circuitry for Piezoelectric Screw Motors; Software for Use with Optoelectronic Measuring Tool; Coordinating Shared Activities; Software Reduces Radio-Interference Effects in Radar Data; Using Iron to Treat Chlorohydrocarbon-Contaminated Soil; Thermally Insulating, Kinematic Tensioned-Fiber Suspension; Back Actuators for Segmented Mirrors and Other Applications; Mechanism for Self-Reacted Friction Stir Welding; Lightweight Exoskeletons with Controllable Actuators; Miniature Robotic Submarine for Exploring Harsh Environments; Electron-Spin Filters Based on the Rashba Effect; Diffusion-Cooled Tantalum Hot-Electron Bolometer Mixers; Tunable Optical True-Time Delay Devices Would Exploit EIT; Fast Query-Optimized Kernel-Machine Classification; Indentured Parts List Maintenance and Part Assembly Capture Tool - IMPACT; An Architecture for Controlling Multiple Robots; Progress in Fabrication of Rocket Combustion Chambers by VPS; CHEM-Based Self-Deploying Spacecraft Radar Antennas; Scalable Multiprocessor for High-Speed Computing in Space; and Simple Systems for Detecting Spacecraft Meteoroid Punctures.

Source record↗

Vertical gradient freeze growth of detector grade CdZnTeSe single crystals

Here, we report the growth of detector grade Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) single crystals, a recently discovered quaternary semiconductor for room temperature radiation detection, by a vertical gradient freeze (VGF) method. VGF is a comparatively low-temperature growth method and avoids relative motion between the heater and the ampoule containing the precursor materials which minimizes any thermal drift or temperature fluctuations. As a result, CZTS single crystals with superior charge transport properties has been obtained. Growth of detector-grade CZTS single crystals using VGF method has not been reported yet. X-ray spectroscopy based elemental analysis showed that the grown crystals demonstrated the desired stoichiometry required for high resolution radiation detection. Planar detectors fabricated by deposition of gold contacts (~0.07 cm 2 ) demonstrated high bulk resistivity ~10 10 Ω-cm and a very low leakage current density of 2.8 × 10 –8 A/cm 2 at a bias of 100 V when measured at room temperature. The detectors showed excellent radiation response with 100 % charge collection efficiency when exposed to 5486 keV alpha particles. The electron mobility-lifetime (μτ) product was measured to be 3 × 10 –3 cm 2 /V using a single polarity Hecht analysis which is at par with the recently reported values measured in CZTS grown using conventional Bridgman or travelling heater method. The electron mobility has been calculated to be 964 cm 2 V –1 s –1 using a time-of-flight (TOF) method, a substantial improvement over that obtained from conventionally grown CZTS single crystals.

36 MATERIALS SCIENCE↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test chamber for low-background IR focal plane testing

A unique and versatile vacuum chamber has been designed for JPL's IR Focal Plane Technology Group. This chamber is equipped with multiple ports for cryogen and electrical vacuum feedthroughs, pumping units, vacuum gages, sources, and detector camera heads. The design incorporates a liquid-nitrogen-cooled optical table and radiation shield for low-background IR detector testing. Focal planes can be tested at temperatures ranging from 300 K to that of liquid helium. This paper describes the design and construction of this low-background IR focal plane test chamber and discusses some of its distinctive features. An analysis of the test chamber's performance is also presented.

Staller, Craig↗

Tuning the Superconducting Transition Temperature of Co-sputtered Iridium and Platinum Films

A superconducting film with a tunable low transition temperature (Tc) is required in high-resolution Transition-Edge Sensor (TES) detectors, which have applications including dark matter detection, low threshold coherent elastic neutrino nucleus scattering measurement, and X-ray spectroscopy. We have been investigating a new approach to tune the Tc of superconducting thin films fabricated by co-sputtering Iridium and Platinum. The effects of Pt concentration and deposition parameters on the films' structural, electrical, and superconducting properties have been studied. AFM and XRD techniques and low temperature resistance measurements have been utilized for film characterization. By varying the Pt concentration and deposition parameters when co-sputtering, we have successfully achieved controllable tuning of Tc in the range of 30-200 mK. The experimental results demonstrate co-sputtering as a viable method for controlling the Tc of Ir-based thin films that can be applied to fabricating high-resolution TESs.

Yefremenko, V. G.↗

Gain stability of Hamamatsu R5912-MOD photomultipliers at low temperature

The Photon Detection System (PDS) is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 PhotoMultiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operating at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu R5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70 °C, although this temperature is rather higher than that of the liquid Argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the isophot detector development

ISOPHOT is one of the four focal plane experiments of the European Space Agency's Infrared Space Observatory (ISO). Scheduled for a 1993 launch, it will operate extrinsic silicon and germanium photoconductors at low temperature and low background during the longer than 18 month mission. These detectors cover the wavelength range from 2.5 to 200 microns and are used as single elements and in arrays. A cryogenic preamplifier was developed to read out a total number of 223 detector pixels.

Wolf, J.↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

Besser, P. J.↗

On Certain New Methodology for Reducing Sensor and Readout Electronics Circuitry Noise in Digital Domain

NASA Hubble Space Telescope (HST) and upcoming cosmology science missions carry instruments with multiple focal planes populated with many large sensor detector arrays. These sensors are passively cooled to low temperatures for low-level light (L3) and near-infrared (NIR) signal detection, and the sensor readout electronics circuitry must perform at extremely low noise levels to enable new required science measurements. Because we are at the technological edge of enhanced performance for sensors and readout electronics circuitry, as determined by thermal noise level at given temperature in analog domain, we must find new ways of further compensating for the noise in the signal digital domain. To facilitate this new approach, state-of-the-art sensors are augmented at their array hardware boundaries by non-illuminated reference pixels, which can be used to reduce noise attributed to sensors. There are a few proposed methodologies of processing in the digital domain the information carried by reference pixels, as employed by the Hubble Space Telescope and the James Webb Space Telescope Projects. These methods involve using spatial and temporal statistical parameters derived from boundary reference pixel information to enhance the active (non-reference) pixel signals. To make a step beyond this heritage methodology, we apply the NASA-developed technology known as the Hilbert- Huang Transform Data Processing System (HHT-DPS) for reference pixel information processing and its utilization in reconfigurable hardware on-board a spaceflight instrument or post-processing on the ground. The methodology examines signal processing for a 2-D domain, in which high-variance components of the thermal noise are carried by both active and reference pixels, similar to that in processing of low-voltage differential signals and subtraction of a single analog reference pixel from all active pixels on the sensor. Heritage methods using the aforementioned statistical parameters in the digital domain (such as statistical averaging of the reference pixels themselves) zeroes out the high-variance components, and the counterpart components in the active pixels remain uncorrected. This paper describes how the new methodology was demonstrated through analysis of fast-varying noise components using the Hilbert-Huang Transform Data Processing System tool (HHT-DPS) developed at NASA and the high-level programming language MATLAB (Trademark of MathWorks Inc.), as well as alternative methods for correcting for the high-variance noise component, using an HgCdTe sensor data. The NASA Hubble Space Telescope data post-processing, as well as future deep-space cosmology projects on-board instrument data processing from all the sensor channels, would benefit from this effort.

Kizhner, Semion↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.