Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Level Waste Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact of Permanganate Oxidation of Glycolate on Corrosion of the Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT), Transfer-line and Waste Tank Materials of Construction (MoC)

Savannah River Remediation (SRR) is evaluating the use of glycolic acid to replace formic acid as an alternate reductant for the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS). The replacement is aimed at reducing facility hazards, improving pH stability and rheological control, and lowering off gas production. Glycolate, which is the product that may remain, can also be carried downstream to High-Level Waste and Low-Level Waste facilities. Complete oxidation of glycolate and other organic species from the Sludge Receipt and Adjustment Tank (SRAT) may be necessary to minimize thermolytic hydrogen generation that can cause flammability issues. The glycolate oxidation may be performed in the Recycle Collection Tank (RCT). The RCT heel would be adjusted with sodium hydroxide to maintain the solution caustic and sodium nitrite as corrosion inhibitor prior to the addition of condensate that can be from the contents of the Slurry Mix Evaporator Condensate Tank (SMECT) or Offgas Condensate Tank (OGCT). The RCT tank collects the waste to be transferred via the Low Point Pump Pit – Recycle Pump Tank (LPPP-RPT) through a jacketed transfer-line to the Tank Farm facility. Scoping studies were performed to evaluate an oxidizing agent and sodium permanganate was selected as the best option for glycolate destruction. Testing was recommended to determine the impact on the Materials of Construction (MoC) due to the addition of sodium permanganate. The targeted concentration of sodium permanganate used equated to a 7:1 molar permanganate to glycolate ratio (nominally 0.002 M permanganate). However, to conservatively maximize the permanganate corrosivity, in some cases no glycolate was added.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air and radon pathways screenings methodologies for the next revision of the E-area PA

The strategic plan for the next E-Area Low-Level Waste Facility Performance Assessment includes recommended changes to the screening criteria used to reduce the number of radioisotopes that are to be considered in the air and radon pathways incorporated into the GoldSim® atmospheric release model (ARM). For the air pathway, a revised screening methodology was developed based on refinement of previous E-Area PA screening approaches and consideration of the strategic plan recommendations. The revised methodology has three sequential screening steps for each radioisotope: (1) volatility test using the Periodic Table of the Elements, (2) stability test based on half-life, and (3) stability test based on volatility as measured by the Henry’s Law constant for the assumed dominant gaseous species or vapor pressure in the case of tritiated water. Of the 1252 radioisotopes listed in the International Commission on Radiological Protection Publication 107, only the 10 that satisfied all three steps of the revised screening methodology will be included in the ARM. They are: Ar-37, Ar-39, Ar-42, C-14, H-3, Hg-194, Hg-203, Kr-81, Kr-85, and Xe-127. For the radon pathway, a revised screening methodology was developed that also has three sequential steps: (1) identify all decay chains that terminate at Rn-222, (2) screen out parents that decay through U-238 because of its 4.5-billion-year primordial half-life, and (3) eliminate remaining parents whose half-life is shorter than one day. Of the 86 possible decay chains leading to Rn-222, six decay chains consist of 15 unique radioisotopes that will be incorporated into the ARM. The 15 radioisotopes are: U-238, Th-234, Pa-234m, Pu-238, U-234, Th-230, Ra-226, Cf-246, Cm-242, Am-242m, Am-242, Np-238, Np-234, Pa-230, and Rn-222.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unreviewed Disposal Question Evaluation: Impact of New Information since 2008 PA on Current Low-Level Solid Waste Operations

Solid low-level waste disposal operations are controlled in part by an E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA) that was completed by the Savannah River National Laboratory (SRNL) in 2008 (WSRC 2008). Since this baseline analysis, new information pertinent to disposal operations has been identified as a natural outcome of ongoing PA maintenance activities and continuous improvement in model simulation techniques (Flach 2013). An Unreviewed Disposal Question (UDQ) Screening (Attachment 1) has been initiated regarding the continued ability of the ELLWF to meet Department of Energy (DOE) Order 435.1 performance objectives in light of new PA items and data identified since completion of the original UDQ Evaluation (UDQE). The present UDQE assesses the ability of Solid Waste (SW) to meet performance objectives by estimating the influence of new information items on a recent sum-of-fractions (SOF) snapshot for each currently active E-Area low-level waste disposal unit. A final SOF, as impacted by this new information, is projected based on the assumptions that the current disposal limits, Waste Information Tracking System (WITS) administrative controls, and waste stream composition remain unchanged through disposal unit operational closure (Year 2025). Revision 1 of this UDQE addresses the following new PA items and data identified since completion of the original UDQE report in 2013: New K d values for iodine, radium and uranium; Elimination of cellulose degradation product (CDP) factors; Updated radionuclide data; Changes in transport behavior of mobile radionuclides; Potential delay in interim closure beyond 2025; and Component-in-grout (CIG) plume interaction correction. Consideration of new information relative to the 2008 PA baseline generally indicates greater confidence that PA performance objectives will be met than indicated by current SOF metrics. For SLIT9, the previous prohibition of non-crushable containers in revision 0 of this UDQE has rendered the projected final SOF for SLIT9 less than the WITS Admin Limit. With respect to future disposal unit operations in the East Slit Trench Group, consideration of new information for Slit Trench#14 (SLIT14) reduced the current SOF for the limiting All-Pathways 200-1000 year period (AP2) by an order of magnitude and by one quarter for the Beta-Gamma 12-100 year period (BG2) pathway. On the balance, updates to K{sub d} values and dose factors and elimination of CDP factors (generally favorable) more than compensated for the detrimental impact of a more rigorous treatment of plume dispersion. These observations suggest that future operations in the East Slit Trench Group can be conducted with higher confidence using current inventory limits, and that limits could be increased if desired for future low-level waste disposal units. The same general conclusion applies to future ST’s in the West Slit Trench Group based on the Impacted Final SOFs for existing ST’s in that area.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed NRCDA Groundwater Pathway Conceptual Model

As requested by Solid Waste Management (SWM), this report documents the Savannah River National Laboratory’s (SRNL’s) evaluation of updated Naval Reactor waste container and inventory projections and proposes a Naval Reactor Component Disposal Area (NRCDA) groundwater (GW) pathway modeling approach for the next E-Area Low-Level Waste Facility (LLWF) Performance Assessment (PA). Two areas within the E-Area LLWF are used as disposal sites for reactor components from the U.S. Navy. Currently, components arrive by rail and are moved by crane to the 643-26E at-grade gravel disposal pad. Prior to operational closure, reactor components were stored and ultimately disposed in-place on the 643-7E NRCDA (Wilhite and Flach 2004). Naval Reactor (NR) waste is comprised of highly radioactive components consisting of activated corrosion-resistant metal alloy contained within welded thick steel casks, and auxiliary equipment primarily contaminated with Activated Corrosion Products (sometimes referred to as “crud” by the U.S. Navy) at low levels and contained within thinner-walled bolted containers. The 643-7E disposal pad, which contains 41 casks and has an interim soil cover, is closed to future receipts. The latest NR waste projections for the 643-26E disposal pad are substantially different from the original estimates due to a change in reactor maintenance. The original estimate was for 50 heavily shielded, welded casks and 50 thinner-walled bolted containers (primarily shield blocks). Currently, NR Programs project 33 heavily shielded, welded casks, of which 31 are already in-place on the 643-26E pad, and 381 thinner-walled bolted containers. In addition to new waste form projections, there have been changes in facility layout and closure plans as well as PA modeling improvements. This report documents these changes as well as key NRCDA recommendations from the 2015 PA Strategic Plan (Butcher 2016).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

E-Area Vault Concrete Material Property And Vault Durability/Degradation Projection Recommendations

Subsequent to the 2008 E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA) (WSRC 2008), two additional E-Area vault concrete property testing programs have been conducted (Dixon and Phifer 2010 and SIMCO 2011a) and two additional E-Area vault concrete durability modeling projections have been made (Langton 2009 and SIMCO 2012). All the information/data from these reports has been evaluated and consolidated herein by the Savannah River National Laboratory (SRNL) at the request of Solid Waste Management (SWM) to produce E-Area vault concrete hydraulic and physical property data and vault durability/degradation projection recommendations that are adequately justified for use within associated Special Analyses (SAs) and future PA updates. The Low Activity Waste (LAW) and Intermediate Level (IL) Vaults structural degradation predictions produced by Carey 2006 and Peregoy 2006, respectively, which were used as the basis for the 2008 ELLWF PA, remain valid based upon the results of the E-Area vault concrete durability simulations reported by Langton 2009 and those reported by SIMCO 2012. Therefore revised structural degradation predictions are not required so long as the mean thickness of the closure cap overlying the vaults is no greater than that assumed within Carey 2006 and Peregoy 2006. For the LAW Vault structural degradation prediction (Carey 2006), the mean thickness of the overlying closure cap was taken as nine feet. For the IL Vault structural degradation prediction (Peregoy 2006), the mean thickness of the overlying closure cap was taken as eight feet. The mean closure cap thicknesses as described here for both E-Area Vaults will be included as a key input and assumption (I&A) in the next revision to the closure plan for the ELLWF (Phifer et al. 2009). In addition, it has been identified as new input to the PA model to be assessed in the ongoing update to the new PA Information UDQE (Flach 2013). Once the UDQE is approved, the SWM Key I&A database will be updated with this new information.

36 MATERIALS SCIENCE↗

Conceptual Modeling Framework for E-Area PA HELP Infiltration Model Simulations

A conceptual modeling framework based on the proposed E-Area Low-Level Waste Facility (LLWF) closure cap design is presented for conducting Hydrologic Evaluation of Landfill Performance (HELP) model simulations of intact and subsided cap infiltration scenarios for the next E-Area Performance Assessment (PA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revised Guidelines for using Cellulose Degradation Product-Impacted Kd Values for Performance Assessments and Composite Analyses

Cellulosic materials include wood, paper, rags, and cardboard products. These materials are co-disposed with radiological waste at the Savannah River Site's (SRS) E-Area Low-Level Waste Facility (ELLWF). Cellulosic materials readily degrade in the environment to form cellulose degradation products (CDP) that will partition to the sediment or remain mobile in the groundwater. Savannah River National Lab (SRNL) has conducted studies to estimate the impact of CDP on radionuclide sorption to SRS sediments (Kd values). It was found that CDP impact on radionuclide sorption varies with radionuclide and CDP concentration. Furthermore, it was found that the amount of carbon (C) in the system could increase or decrease Kd values with respect to the base case of when no CDP was added. Throughout the expected pH range of the ELLWF, a low concentration of CDP in the system would increase Kd values (because C would sorb to the sediment and provide more exchange sites for radionuclides to sorb), whereas greater concentrations of CDP (≥20 mg/L C) would decrease Kd values (because C would remain in solution and complex the radionuclide and not permit the radionuclide to sorb to the sediment). A review of >230 dissolved organic carbon (DOC) groundwater concentrations in the Old Radioactive Waste Burial Ground (ORWBG) at the SRS indicated that the average DOC concentration, a gross measure of CDP, was 5 mg/L C. At approximately this DOC concentration, the laboratory studies demonstrated that no anions (Tc, I, or Se) or cations (Ni, Sr, Ce, Eu, Zr, or Th) have decreased sorption in the presence of carbon (an analogue for CDP).

09 BIOMASS FUELS↗

Special Analysis for Slit Trench Disposal of the Reactor Process Heat Exchangers

The Savannah River National Laboratory (SRNL), in response to a request from Solid Waste Management (SWM), conducted a Special Analysis (SA) to evaluate the performance of nineteen heat exchangers that are to be disposed in the E-Area low level waste facility Slit Trench 9 (ST 9). Although these nineteen heat exchangers were never decontaminated, the majority of the radionuclides in the heat exchanger inventory list were determined to be acceptable for burial because they are less than the 'generic' waste form inventory limits given in the 2008 Performance Assessment (PA) (WSRC, 2008). However, as generic waste, the H-3 and C-14 inventories resulted in unacceptable sum-of-fractions (SOFs). Initial scoping analyses performed by SRNL indicated that if alterations were made to certain external nozzles to mitigate various potential leak paths, acceptable SOFs could be achieved through the use of a 'Special' waste form. This SA provides the technical basis for this new 'Special' waste form and provides the inventory limits for H-3 and C-14 for these nineteen heat exchangers such that the nineteen heat exchangers can be disposed in ST 9. This 'Special' waste form is limited to these nineteen heat exchangers in ST 9 and applies for H-3 and C-14, which are designated as H-3X and C-14X, respectively. The SA follows the same methodology used in the 2008 PA and the 2008 SA except for the modeling enhancements noted below. Infiltration rates above the heat exchangers are identical to those used in the 2008 PA; however, flow through the heat exchangers is unique. Because it is unknown exactly how sealed heat exchanger openings will perform and how surface and embedded contaminants will be released, multiple base cases or scenarios were established to investigate a set of performances. Each scenario consists of flow options (based on the performance of sealed openings) and a near-field release of contaminants (based on corrosion and diffusion performance). Two disposal configurations were analyzed where heat exchangers were assumed to be disposed four across and five lengthwise (the 4x5 configuration, with one empty) and three across and seven lengthwise (the 3x7 configuration, with two empty). A large range of conditions was considered. For example, peak well concentrations at the 100-m boundary for H-3 are shown in Figure ES-1 for a wide range of configurations (i.e. release mechanism and degree of sealing options). The maximum contaminant level (MCL) and a 10% SOF goal for H-3 are also shown. The 10% goal was based on an estimated volume fraction that these nineteen heat exchangers would consume in ST 9 and was solely used for scoping purposes to assess disposal feasibility and sealing requirements. Because various line breaks and poor sealing greatly exceeded that 10% goal, the determination was made that mitigating activities were needed, such as protection from line breaks and better sealing. An initial set of scenarios was run to assess the requirements for sealing the heat exchanger openings and the need to ensure that the sealed heat exchangers stayed sealed during transit and disposal operations. After discovering that such mitigating activities were required, additional scenarios were run that included the mitigating activities. Scenarios deemed to have a very low probability of occurrence were excluded from consideration for calculating inventory limits (for example, those scenarios that assumed an instantaneous release of contaminants along with poor sealing). The SA used the most recent K d values for the C-14 analyses and the most recent Dose Conversion Factors for H-3 and C-14 which have been updated since the 2008 PA was issued. This SA took into account the location and the disposal timing of these heat exchangers. The disposal location is within a small area of the overall Slit Trench unit (about 6% of the total) and is behind a line that is 200 ft from the down-gradient edge of ST 9. The disposal timing is assumed to be after July 1, 2012 (because disposals cannot occur until this document is approved and mitigating activities are completed) which means that the disposal occurs after the first time period for the 2008 PA beta-gamma pathway (that time period is from December 1995 until December 2007), thus that pathway time period is not considered. Table ES-1 provides new 'Special' waste form groundwater pathway inventory limits for C-14X and H-3X in the heat exchangers. Inventory limits for generic C-14 and H-3 in the West Slit Trenches are included for comparison. The lowest limit for generic C-14 is 1.9E-1 Ci, while for C-14X it is 2.7E0, an increase of more than 14 times. Because time windows are employed, at later times C-14X exhibits lower limits than those for generic C-14 because with its smaller K d the C-14 moves much faster. The lowest limit for generic H-3 is 3.6E0 Ci, while for H-3X it is 1.7E3, an increase of almost 500 times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dose Calculation Methodology and Data for Solid Waste Performance Assessment and Composite Analysis at the Savannah River Site

This report provides a detailed description of the methodology developed to perform dose calculations for E-Area Low Level Waste Facility Performance Assessments and Savannah River Site Composite Analyses. Chapters 2 – 8 give a complete set of equations to be used to calculate dose for individual exposure pathways. The first set of dose scenarios assume that a member of the public establishes residence near the waste site and uses contaminated groundwater or contaminated surface water for personal consumption and to irrigate a garden and pasture where produce and farm animals are raised. Products from the garden and farm animals are used for personal consumption. This scenario applies to both E-Area Performance Assessments and Savannah River Site Composite Analyses. General dose exposure pathways for the resident farmer scenario are: 1. Ingestion pathways described in Chapter 2, 2. Inhalation pathways described in Chapter 3, 3. External exposure pathways described in Chapter 4, and 4. Recreational pathways described in Chapter 5 (Composite Analysis only). Doses from all of the above pathways are directly related to the contaminant concentration in the water. Additional dose scenarios considered for E-Area Performance Assessment assume that an inadvertent intruder encroaches on the waste disposal site after loss of institutional control. General dose exposure pathways considered for the inadvertent intruder are: 1. Ingestion pathways described in Chapter 6, 2. Inhalation pathways described in Chapter 7, and 3. External exposure pathways described in Chapter 8. Doses from all of the intruder pathways are directly related to the contaminant concentration in the buried waste. Special dose considerations related to human consumption of meat and dairy, and treatment of tritium in dose calculations are discussed in Chapter 9. Chapter 10 describes an Excel database named “Radionuclide, Element and Dose Parameter Data Package” that has been created to provide a system for maintaining the data required to perform radionuclide transport and dose calculations. This data includes: Isotope physical parameters and radioactive decay data needed for both transport and dose calculations, Isotope-specific dose coefficients and soil shielding factors associated with exposure pathways, Radionuclide drinking water concentration limits either published by the Environmental Protection Agency or derived from internal dose coefficients to meet the groundwater protection requirements in Department of Energy Order 435.1, Element-specific bio-transfer factors used in dose calculations, Dose equations and values of physical parameters and human factors used in dose calculations, and Key physical constants used in dose calculations.

54 ENVIRONMENTAL SCIENCES↗

Impact of Different Vegetative Cover Scenarios on Infiltration Rates for the E-Area PA Intact Case

This memorandum addresses the effects of vegetative cover type (bamboo versus Bahia grass) and the timing of pine tree intrusion on intact infiltration rate for the proposed E-Area Low-Level Waste Facility (LLWF) closure cap system. It builds upon earlier reports whose purpose is to lay the foundation for the infiltration data package that will be assembled during the next revision of the E-Area LLWF Performance Assessment (PA).

54 ENVIRONMENTAL SCIENCES↗

GoldSim® Aquifer Model Calibration and Plume Interaction

The E-Area Low-Level Waste Facility (ELLWF) Probabilistic Aquifer Model (PAM) utilizes GoldSim ® Monte Carlo simulation software (GTG, 2017) to evaluate the transport of a tracer species as it travels from the water table below the disposal unit footprint, through the aquifer, to the Point of Assessment (POA) at the 100-meter boundary. This report documents the development and calibration of PAM as well as the implementation of plume interaction. PAM is a key component of the effort to include uncertainty quantification and sensitivity analysis (UQSA) in the next revision of the E-Area Performance Assessment (PA), considering recommendations from the 2015 PA strategic planning team outlined by Butcher and Phifer (2016). The Aquifer Model and associated optimized geometric parameters will be implemented in the future GoldSim® (GS) system model that will simulate subsurface flow and radionuclide transport from the ground surface to the 100-meter POA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intact Infiltration Model Design Check for E-Area LLWF

A design check will be performed on the infiltration-rate time profile for the intact case for the proposed E-Area Low-Level Waste Facility (LLWF) final closure cap design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subsidence Infiltration Model Design Check for E-Area LLWF

A design check will be performed on the revised Python-based probabilistic subsidence infiltration model for the proposed E-Area Low-Level Waste Facility (LLWF) final closure cap design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

E-Area LLWF Final Closure Cap Design – Constructability Evaluation Criteria for the Plot 8 and NR07E Disposal Areas

SRNS Design Engineering has been asked to complete a constructability evaluation of the proposed final closure cap designs for the Plot 8 (Engineered Trenches ET07, ET08, and ET09) and 643-7E NRCDA (NR07E) disposal areas located outside the original E-Area Low-Level Waste Facility (ELLWF) footprint. This memorandum presents the guidelines and criteria for the constructability evaluation. A new conceptual design for the ELLWF closure cap is not requested at this time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GSA Aquifer Cutouts for E-Area PA Revision Transport Simulations

The 2018 General Separations Area (GSA) aquifer model is dissected into four refined cutouts for aquifer transport in preparation for the next E-Area Low-Level Waste Facility (LLWF) Performance Assessment (PA) revision. The recommended refined horizontal and vertical grid sizes are 20 ft and 3 ft, respectively. The horizontal resolution appropriately represents longitudinal dispersion with dispersivity of 15.4 ft. Four cutouts (i.e., West, Center, East 1, and East 2) are selected to adequately contain tracer plumes emanating from disposal units expected in the E-Area LLWF. For feasible computation, each cutout is refined to mesh sizes much less than the PORFLOW limit of 1,024,000 nodes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safety Functions and Features, Events and Processes for the E-Area Performance Assessment

The DOE Technical Standard, “Disposal Authorization Statement and Tank Closure Documentation,” (DOE 2017) recommends the use of safety functions and features, events and processes (FEPs) to support development of conceptual models and identification of scenarios to be considered in a performance assessment (PA). The FEP process provides a means to describe how a PA considers and addresses the factors that could influence the performance of key barriers. Understanding the roles of barriers in terms of limiting migration helps to focus on how changes in the system could lead to a situation where those roles cannot be fulfilled and there is the potential for compromised performance. The FEPs screening and review process was used to identify FEPs that are relevant for the EArea Low-Level Waste Facility (LLWF) and specifically those FEPs that could have a detrimental impact on the effectiveness of a given safety function. For this PA, a default list of FEPs developed at the International Atomic Energy Agency (IAEA 2004) and an approach implemented for PAs at the Hanford and Idaho sites (Mehta et al. 2016, DOE-ID 2019) are used to identify processes and events that could influence the effectiveness of a given safety function for the E-Area LLWF (e.g., subsidence can impact the safety function of the cover system and lead to increased infiltration). The Hanford and Idaho PAs represent two of the most recent applications of this approach. The PA evaluates the potential impacts of changes in performance of different features of the system and demonstrates that the safety functions represent multiple and redundant barriers. Barrier analyses, assuming a safety function is not present, also test the robustness of the system in the event of the loss of one or more safety functions. Such evaluations also support a qualitative illustration of the concept of defense in depth. The safety concept for closure of the E-Area LLWF (generically referred to as “E-Area”) encompasses a variety of different features (i.e., administrative controls, natural site features, and engineered barriers) that reduce the potential impacts on human health and the environment from the residual waste that will remain after closure. These features can be represented as a collection of safety functions acting independently and as a system to provide for overall safety. In some applications, there have been attempts to assign numerical expectations to specific safety functions, but that is not the intent in this case. The concept of safety functions is used more qualitatively in two ways for this PA: 1. To illustrate the robustness of the E-Area design, operational practices and closure approach by documenting features that are and are not credited in different modeling cases. 2. To identify the roles of the different features and potential processes and events that could compromise the performance of safety features and need to be considered when developing the modeling approach. This report addresses both safety functions and FEPs for the E-Area PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comoparison of Slit Trench and Engineered Trench 3D Vadose Zone Conceptual Models

In the next revision of the E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA), radionuclide groundwater transport from slit (ST) and engineered trenches (ET) will be simulated using 3-dimensional PORFLOW models representing the vadose zone. In total, the conceptual framework will aim to model 29 total trenches with a degree of conservatism that provides a high level of confidence in meeting performance objectives. The implementation of generic conceptual models allows for a reasonable number of simulation scenarios, thereby reducing the chances of errors and enabling a better one-to-one comparison between the results, while still capturing the most important features of each trench. The current investigation seeks to understand if a generic trench model based on the general ET footprint can justifiably be used for representing both STs and ETs while maintaining a reasonable degree of conservatism. In this process, the groundwater transport of several key radionuclides was simulated for both ET and ST geometries and the flux-to-the-water-table profiles were compared. For all radionuclides simulated, the ET geometry is shown to be conservative (i.e., produces the highest peak flux to the water table).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗