Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Long stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Structural load control during construction

The topics are presented in viewgraph form and include the following: examples of high transient loadings on large space structures; energy absorbing/load limiting strut research objectives; scope of research on energy absorbing struts to date; energy characteristics of cantilevered trusses with a tip load; ten bay long resilient truss example; stored energy characteristics of one meter deep truss; energy absorbing potential for 10-bay 5-meter deep truss; schematic of energy absorbing strut; linear load and motion control actuator; rigid body response of a solar array to the shuttle thruster pressure impingement; solar array piecewise linear response; solar array characteristics; solar array tip deflection and required actuator stroke; solar array response from finite element analysis; 12 bay energy absorbing test bed dynamics; and new AERO-Lab with 12-bay test beam.

Mikulas, Martin↗

Dynamics of the inlet system of a four-stroke engine

Tests were run on a single-cylinder and a multicylinder four-stroke engine in order to determine the effect of the dynamics of the inlet system upon indicated mean effective pressure. Tests on the single-cylinder engine were made at various speeds, inlet valve timings, and inlet pipe lengths. These tests indicated that the indicated mean effective pressure could be raised considerably at any one speed by the use of a suitably long inlet pipe. Tests at other speeds with this length of pipe showed higher indicated mean effective pressure than with a very short pipe, although not so high as could be obtained with the pipe length adjusted for each speed. A general relation was discovered between optimum time of inlet valve closing and pipe length; namely, that longer pipes require later inlet valve closing in order to be fully effective. Tests were also made on three cylinders connected to a single pipe. With this arrangement, increased volumetric efficiency at low speed was obtainable by using a long pipe, but only with a sacrifice of volumetric efficiency at high speed. Volumetric efficiency at high speed was progressively lower as the pipe length was increased.

ENGINES-CHRYSLER↗

Effect of gravity opientation on the thermal performance of Stirling-type pulse tube cryocoolers

This paper extends the investigation of angular orientation effects to the refrigeration performance of high frequency (-40 Hz) Stirling-type pulse tube cryocoolers typical of those used in long-life space applications. Strong orientation effects on the performance of such cryocoolers have recently been observed during system-level testing of both linear and U-tube type pulse tubes. To quantify the angular dependency effects, data have been gathered on both U-tube and linear type pulse tubes of two different manufacturers as a function of orientation angle, cold-tip temperature, and compressor stroke.

angular dependency↗

Orthostatic Hypotension After Long-Duration Space Flight: NASA's Experiences from the International Space Station

Our laboratory previously reported that the incidence of orthostatic hypotension (OH) was greater after long- than short-duration spaceflight in astronauts who participated in Mir Space Station and Space Shuttle missions. To confirm and extend these findings, we retrospectively examined tilt test data from International Space Station (ISS) and Shuttle astronauts. We anticipated that the proportion of ISS astronauts experiencing OH would be high on landing day and the number of days to recover greater after long- than short-duration missions. Methods: Twenty ISS and 66 Shuttle astronauts participated in 10-min 80? head-up tilt tests 10 d before launch (L-10), on landing day (R+0) or 1 d after landing (R+1). Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. Many astronauts repeated the test 3 d (R+3) after landing. Fisher?s Exact Test was used to compare the ability of ISS and Shuttle astronauts to complete the tilt test on R+0. Cox regression was used to identify cardiovascular parameters that were associated with test completion across all tests, and mixed model analysis was used to compare the change and recovery rates between ISS and Shuttle astronauts. In these analyses, ISS data from R+0 and R+1 were pooled to provide sufficient statistical power. Results: The proportion of astronauts who completed the tilt test on R+0 without OH was less in ISS than in Shuttle astronauts (p=0.03). On R+0, only 2 of 6 ISS astronauts completed the test compared to 53 of 66 (80%) Shuttle astronauts. However, 8 of 9 ISS astronauts completed the test on R+1. On R+3, 13 of 15 (87%) of the ISS and 19 of 19 (100%) of the Shuttle astronauts completed the 10-min test. An index comprised of stroke volume and diastolic blood pressure provided a very good prediction of overall tilt survival. This index was altered by spaceflight similarly for both groups soon after landing (pooled R+0 and R+ 1), but ISS astronauts did not recover at the same rate as Shuttle astronauts (p=0.007). Conclusions: The proportion of ISS astronauts who could not complete the tilt test on R+0 due to OH (4 of 6) is similar to that reported in astronauts who flew on Mir (5 of 6). Further, cardiovascular parameters most closely associated with OH recover more slowly after long- compared to short-duration spaceflight.

Lee, Stuart M. C.↗

Time-Sequenced Flow Field Prediction in an Optima Spark-Ignition Direct-Injection Engine Using Bidirectional Recurrent Neural Network (bi-RNN) with Long Short-Term Memory

To further improve the energy conversion efficiency of internal combustion engine, the transient and complex air flow movement inside the cylinder needs to be better understood and controlled. Although the in-cylinder flow fields are highly stochastic with strong cycle-to-cycle fluctuations, machine learning can still provide an efficient way to learn and regress the complex flow movement process inside the cylinder. In this work, a bidirectional recurrent neural network (bi-RNN) model with long short-term memory was applied to predict the in-cylinder flow fields at different time steps using training data from mull-cycle particle image velocimetry (PIV) measurements. To evaluate the agreement between the true and predicted flow fields, structure and magnitude comparison indices are calculated both globally and locally. The comparison results show that the bi-RNN model can accurately predict the bulk flow and vortex motions from early intake stroke to compression stroke. This work demonstrates that the machine learning model has the potential to predict the underlying dynamics of the interaction between in-cylinder flows and provides a reliable way to improve temporal resolution in PIV flow data to better reveal transient in-cylinder flow features.

Bi-RNN model↗

Global Premature Mortality By Dust and Pollution PM 2.5 Estimated From Aerosol Reanalysis of the Modern-Era Retrospective Analysis for Research and Applications, Version 2

This study quantifies global premature deaths attributable to long-term exposure of ambient PM 2.5 , or PM 2.5 -attributable mortality, by dust and pollution sources. We used NASA’s Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA-2) aerosol reanalysis product for PM 2.5 and the cause-specific relative risk (RR) from the integrated exposure-response (IER) model to estimate global PM2.5-attributable mortality for five causes of deaths, namely ischaemic heart disease (IHD), cerebrovascular disease (CEV) or stroke, lung cancer (LC), chronic obstructive pulmonary disease (COPD), and acute lower respiratory infection (ALRI). The estimated yearly global PM 2.5 -attributable mortality in 2019 amounts to 2.89 (1.38–4.48) millions, which is composed of 1.19 (0.73–1.84) million from IHD, 1.01 (0.35–1.55) million from CEV, 0.29 (0.11–0.48) million from COPD, 0.23 (0.14–0.33) million from ALRI, and 0.17 (0.04–0.28) million from LC (the numbers in parentheses represent the estimated mortality range due corresponding to RR spread at the 95% confidence interval). The mortality counts vary with geopolitical regions substantially, with the highest number of deaths occurring in Asia. China and India account for 40% and 23% of the global PM 2.5 -attributable deaths, respectively. In terms of sources of PM 2.5 , about 22% of the global all-cause PM 2.5 -attributable deaths are caused by desert dust. The largest dust attribution is 37% for ALRI. The relative contributions of dust and pollution sources vary with the causes of deaths and geographical regions. Enforcing air pollution regulations to transfer areas from PM 2.5 nonattainment to PM2.5 attainment can have great health benefits. Being attainable with the United States air quality standard (AQS) of 15 μg/m 3 globally would have avoided nearly 40% or 1.2 million premature deaths. The most recent update of PM 2.5 guideline from 10 to 5 μg/m 3 by the World Health Organization (WHO) would potentially save additional one million lives. Our study highlights the importance of distinguishing aerodynamic size from geometric size in accurately assessing the global health burden of PM 2.5 and particularly for dust. A use of geometric size in diagnosing dust PM 2.5 from the model simulation, a common approach in current health burden assessment, could overestimate the PM 2.5 level in the dust belt by 40–170%, leading to an overestimate of global all-cause mortality by 1 million or 32%.

PM2.5↗

Electromagnetic power of lightning superbolts from Earth to space

Lightning superbolts are the most powerful and rare lightning events with intense optical emission, first identified from space. Superbolt events occurred in 2010-2018 could be localized by extracting the high energy tail of the lightning stroke signals measured by the very low frequency ground stations of the World-Wide Lightning Location Network. Here, we report electromagnetic observations of superbolts from space using Van Allen Probes satellite measurements, and ground measurements, and with two events measured both from ground and space. From burst-triggered measurements, we compute electric and magnetic power spectral density for very low frequency waves driven by superbolts, both on Earth and transmitted into space, demonstrating that superbolts transmit 10-1000 times more powerful very low frequency waves into space than typical strokes and revealing that their extreme nature is observed in space. We find several properties of superbolts that notably differ from most lightning flashes; a more symmetric first ground-wave peak due to a longer rise time, larger peak current, weaker decay of electromagnetic power density in space with distance, and a power mostly confined in the very low frequency range. Their signal is absent in space during day times and is received with a long-time delay on the Van Allen Probes. These results have implications for our understanding of lightning and superbolts, for ionosphere-magnetosphere wave transmission, wave propagation in space, and remote sensing of extreme events.

79 ASTRONOMY AND ASTROPHYSICS↗

The Unit of Lightning

For the past century, scientists have made quantitative measurements of lightning discharges. In the process, they refined the definition of a lightning unit, or basic quantum of lightning, in order to base it on observable parameters. Although many components of a lightning discharge have been identified, lightning usually occur in groups of discharges or pulses that, although complex, can be organized into units of flashes. This unit definition is based mainly on measurements of lightning from electric field, video, and ground flash lightning locating networks. More recent instrumentation with various combinations of high sensitivity, high temporal, or high spatial resolution often measure signals produced by lightning that do not cleanly divide into flashes. The data from these systems indicate the need or a more fundamental unit for lightning. Such a unit would be of benefit for both basic understanding of lightning and comparing lightning information between instruments. Without a common lightning unit definition, intercomparisons are difficult. For an example, the Lightning Detection And Ranging system (LDAR) at Kennedy Space Center (KSC) have detected ,flash' rates as high as 600 per minute while analysis based on the Advanced Ground Based Field Mill network (AGBFM) detect only 33 "flashes" per minute in the same area and time periods. The satellite based Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) sometimes see single "flashes" that last longer than 10 seconds. Such long duration flashes are not found in electric field records or ground strike location system data sets. The unit of lightning should be based on the fundamental components of the lightning discharge. This should make the unit as generally applicable as possible. For example, studies of NO(x) production by lightning depend on parameters of the individual lightning channels and not the summary flash characteristics. For such studies, the best unit of lightning may be closer to the classical stroke in the electric field data sets, flash in the LDAR data sets, and group in the OTD/LIS data sets. For this type of study, however, more than just the stroke count information is needed. In this paper, we will outline the current definitions of the unit of lightning and propose new basic definitions for the unit of lightning. Since different instruments detect lightning in different ways and different studies may need almost mutually exclusive aspects of the lightning discharge, there may not be a single definition of the unit of lightning that can be applied to all systems and all studies. However, common components can be found since all instrumentation are detecting aspects of the same phenomenon.

Mach, Douglas M.↗

Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997-2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18-90) years with mean follow-up of 15 (range, 0-61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Challenges of Designing a 13-Hz High-Load Vibration Isolation System with Tight Volume Constraints: Lessons Learned and Path Forward

This paper describes the design of a passive isolation system using D-struts (Registered TradeMark) to isolate an optical payload from aircraft-borne jitter with challenging stroke per volume requirements. It discusses the use of viscoelastic-coated D-struts® that meet the customer performance and outgassing specification, NASA-1124. The result was a relatively soft isolation system, (where the first mode was 13 Hz), with each individual strut capable of withstanding loads on the order of magnitude of 623 N (140 lbf), weighing less than 910 g (2 lbm), fitting in a volume 5.1 cm (2 inches) in diameter and 12-cm (4.7-inches) long and capable of performing up to 1000 Hz without nonlinearities.

Dearing, Stella↗

...And the Beats Keep Runnin Runnin (In Space)

Introduction: This case series describes the medical clearance of NASA astronauts after diagnosis of atrial fibrillation seeking to fly to the International Space Station (ISS). BACKGROUND: Atrial fibrillation is the most common sustained arrhythmia with increasing incidence with age and is associated with increased lifetime risk of stroke. Treatment may consist of pharmacologic rate control and anticoagulation. Although it is not yet known how spaceflight modifies risk of cardioembolic event or adverse treatment effects, these can have significant impact on mission and crew health for spaceflight and granting a medical waiver for flight is a complex, case-by-case consideration. Case Presentation: We reviewed all records of waivers granted by NASA for atrial fibrillation and flutter, and identified 6 cases (4 short-duration [<18 days] and 2 long-duration missions [>60 days]) where waiver was granted with subsequent spaceflight. DISCUSSION: NASA has approved astronauts with a history of atrial fibrillation or flutter for flight following an appropriate medical evaluation. With the high prevalence of atrial fibrillation in the general population, we anticipate that consideration of medical waiver will become increasingly common as commercial spaceflight grows. These cases provide a potential framework for risk assessment and management of this population, to balance potential risk modification inherent in the microgravity environment against implications to crew performance, mission success, and personal health of spaceflight participants

Space Medicine↗

Cleaner Cooking: Exploring Tools to Measure and Understand the Long-term Adoption and Environmental Significance of Cookstoves in India

About 40% of the world’s population, or roughly 3 billion people, rely on solid biomass fuels like coal, wood, dung, and crop residues to cook and meet their household energy needs. This outdated energy system has severe social, health, and environmental implications. Women are disproportionately affected as they predominantly bear the burden of cooking and collecting fuelwood, which exacerbates the “time poverty” trap that restricts them from participating in economic and educational activities. Exposure to indoor solid fuel combustion, also known as household air pollution, is responsible for 3-4 million premature deaths per year and is a leading risk factor for chronic obstructive pulmonary disease, childhood pneumonia, stroke, ischemic heart disease, and lung cancer. Solid-fuel cooking contributes to 16% of global ambient air pollution, emitting CO 2 and other climate-forcing pollutants like carbon monoxide, black carbon, and methane.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Minute-by-Minute Cardiovascular Measurements During Tilt Tests to Strengthen Inference on the Effect of Long-Duration Space Flight on Orthostatic Hypotension

Typical methodology for evaluating the effects of spaceflight on orthostatic hypotension (OH) has been survival analysis of tolerance times from 80 head-up tilt tests. However when scheduled test durations are short, there may not be enough failures to allow survival analysis to adequately estimate and compare the effects of flight phase (e.g. pre-flight, number of days post-flight), flight duration, and their interaction, as well as interactions with effects of interventions or countermeasures. The problem is exacerbated in the presence of a repeated measures design, in which subjects participate in tilt tests during various flight phases. Here we show how it is possible to dramatically improve the efficiency of statistical inference in this setting by making use of the additional information contained in minute-by-minute observations of cardiovascular parameters thought to be reflective of progression towards presyncope during tilt testing. Methods: We retrospectively examined operational tilt test (OTT; 10 -min 80 head-up tilt) data from 20 International Space Station (ISS) and 66 Shuttle astronauts 10 d before launch (L-10), on landing day (R+0) and during recovery (R+1, R+3, R+6-10) depending on the level of participation. Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. In addition to OTT survival time, 8 cardiovascular parameters (CP: heart rate, systolic, diastolic, and mean arterial blood pressure, pulse pressure, stroke volume, cardiac output, and total peripheral resistance) that might be predictive of progression towards presyncope were measured every minute of each OTT. Statistical analysis was predicated on a two ]stage model of causation. In the first stage, flight duration and time from landing affect the astronauts' degree of OH, which is manifested in the time trends and variation of the above CPs during OTTs. In the second stage, the behavior of these parameters directly affects OTT survival time. Actual analysis proceeded in the opposite direction. First we identified those CPs or linear combinations that best predicted OTT survival regardless of what spaceflight conditions led to OTT completion or presyncope. From these, we calculated a summary statistic (one per OTT) that best predicted survival. We then used mixed ]model regression analysis to relate changes in the summary statistic to flight phase and duration. Inference on the effects of phase, duration, and their interaction on OH follows directly from this second analysis. Results: A linear combination (W) of diastolic blood pressure (DBP) and stroke volume (SV) was found to be the best predictor of OTT survival using the complete data set of minute-by-minute observations of CPs for each OTT. Furthermore, the log-transformed standard deviation of W (Z = log SW) was found to be a strong predictor of survival in the reduced data set consisting of one observation per OTT. In other words, this measure of variability of W during an OTT was the best indicator of whether or not the subject could complete the 10-min test, with higher variability (i.e. higher values of Z) being associated with greater probability of failure. In the mixed-model regression analysis where Z was now treated as a outcome with flight phase and duration groups (ISS and STS) as predictors, we found that there was a significantly more variability in W (higher values of Z) for both groups at R+0, but with no evidence of an interaction until R+3, when the ISS group still had inflated variability, but not the STS group. Conclusions: Variability of the cardiovascular index W recovers more slowly after long-compared to short-duration spaceflight. Since high variability of W has also been shown to be predictive of OTT failure, a primary manifestation of OH, a logical conclusion is that recovery from OH also is slower after long-duration compared to short-duration spaceflights.

Feiveson, Alan H.↗

Single-fraction Radiosurgery for Presumed Intracranial Meningiomas: Efficacy and Complications From a 22-Year Experience

Purpose: To define the rate of tumor control and factors associated with radiation-related complications after single-fraction radiosurgery (SRS) for patients with imaging defined intracranial meningiomas. Materials and Methods: Retrospective review of 251 patients (192 women, 59 men) having SRS for imaging-defined intracranial meningiomas between 1990 and 2008. Excluded were patients with radiation-induced tumors, meningiomatosis, or neurofibromatosis. The mean patient age was 58.6 {+-} 13.4 years. The majority of tumors involved the skull base/tentorium (n = 210, 83.7%). The mean treatment volume was 7.7 {+-} 6.2 cm{sup 3}; the mean tumor margin dose was 15.8 {+-} 2.0 Gy. Follow-up (mean, 62.9 {+-} 43.9 months) was censored at last evaluation (n = 224), death (n = 22), or tumor resection (n = 5). Results: No patient died from tumor progression or radiation-related complications. Tumor size decreased in 181 patients (72.1%) and was unchanged in 67 patients (26.7%). Three patients (1.2%) had in-field tumor progression noted at 28, 145, and 150 months, respectively. No patient had a marginal tumor progression. The 3- and 10-year local control rate was 99.4%. One patient had distant tumor progression at 105 months and underwent repeat SRS. Thirty-one patients (12.4%) had either temporary (n = 8, 3.2%) or permanent (n = 23, 9.2%) symptomatic radiation-related complications including cranial nerve deficits (n = 14), headaches (n = 5), hemiparesis (n = 5), new/worsened seizure (n = 4), cyst-formation (n = 1), hemifacial spasm (n = 1), and stroke (n = 1). The 1- and 5-year complication rates were 8.3% and 11.5%, respectively. Radiation-related complications were associated with convexity/falx tumors (HR = 2.8, 95% CI 1.3-6.1, p = 0.009) and increasing tumor volume (HR = 1.05, 95% CI 1.0-1.1, p = 0.04) on multivariate analysis. No patient developed a radiation-induced tumor. Conclusions: Single-fraction SRS at the used dose range provides a high rate of tumor control for patients with imaging defined intracranial meningiomas. However, treatment failures were noted after 10 years emphasizing the need for long-term imaging follow-up after meningioma SRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MIT's interferometer CST testbed

The MIT Space Engineering Research Center (SERC) has developed a controlled structures technology (CST) testbed based on one design for a space-based optical interferometer. The role of the testbed is to provide a versatile platform for experimental investigation and discovery of CST approaches. In particular, it will serve as the focus for experimental verification of CSI methodologies and control strategies at SERC. The testbed program has an emphasis on experimental CST--incorporating a broad suite of actuators and sensors, active struts, system identification, passive damping, active mirror mounts, and precision component characterization. The SERC testbed represents a one-tenth scaled version of an optical interferometer concept based on an inherently rigid tetrahedral configuration with collecting apertures on one face. The testbed consists of six 3.5 meter long truss legs joined at four vertices and is suspended with attachment points at three vertices. Each aluminum leg has a 0.2 m by 0.2 m by 0.25 m triangular cross-section. The structure has a first flexible mode at 31 Hz and has over 50 global modes below 200 Hz. The stiff tetrahedral design differs from similar testbeds (such as the JPL Phase B) in that the structural topology is closed. The tetrahedral design minimizes structural deflections at the vertices (site of optical components for maximum baseline) resulting in reduced stroke requirements for isolation and pointing of optics. Typical total light path length stability goals are on the order of lambda/20, with a wavelength of light, lambda, of roughly 500 nanometers. It is expected that active structural control will be necessary to achieve this goal in the presence of disturbances.

Hyde, Tupper↗

Peak Oxygen Uptake during and after Long-duration Space Flight

Aerobic capacity (VO2peak) previously has not been measured during or after long-duration spaceflight. PURPOSE: To measure VO2peak and submaximal exercise responses during and after International Space Station (ISS) missions. METHODS: Astronauts (9 M, 5 F: 49 +/- 5 yr, 175 +/- 7 cm, 77.2 +/- 15.1 kg, 40.6 +/- 6.4 mL/kg/min [mean +/-SD]) performed graded peak cycle tests ~90 days before spaceflight, 15 d (FD15) after launch and every ~30 d thereafter during flight, and 1 (R+1), 10 (R+10), and 30 d (R+30) after landing. Oxygen consumption (VO2) and heart rate (HR) were measured from rest to peak exercise, while cardiac output (Q), stroke volume (SV), and arterial-venous oxygen difference (a-vO2diff) were measured only during rest and submaximal exercise. Data were analyzed using mixed-model linear regression. Body mass contributed significantly to statistical models, and thus results are reported as modeled estimates for an average subject. RESULTS: Early inflight (FD15) VO2peak was 17% lower (95% CI = - 22%, -13%) than preflight. VO2peak increased during spaceflight (0.001 L/min/d, P = 0.02) but did not return to preflight levels. On R+1 VO2peak was 15% (95% CI = -19%, -10%) lower than preflight but recovered to within 2% of preflight by R+30 (95% CI = -6%, +3%). Peak HR was not significantly different from preflight at any time. Inflight submaximal VO2 and a-vO2diff were generally lower than preflight, but the Q vs. VO2 slope was unchanged. In contrast, the SV vs. VO2 slope was lower (P < 0.001), primarily due to elevated SV at rest, and the HR vs. VO2 slope was greater (P < 0.001), largely due to elevated HR during more intense exercise. On R+1 although the relationships between VO2 and Q, SV, and HR were not statistically different than preflight, resting and submaximal exercise SV was lower (P < 0.001), resting and submaximal exercise HR was higher (P < 0.002), and a-vO2diff was unchanged. HR and SV returned to preflight levels by R+30. CONCLUSION: In the average astronaut VO2peak was reduced during spaceflight and immediately after landing but factors contributing to lower VO2peak may be different during spaceflight and recovery. Maintaining Q while VO2 is reduced inflight may be suggestive of an elevated blood flow to vascular beds other than exercising muscles, but decreased SV after flight likely reduces Q at peak exertion.

Moore, Alan D., Jr.↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Expansion Thermal Switch for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the thermal switch (TS) operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center including the pre-vibe thermal vacuum cycle test, vibration test, post-vibe thermal vacuum cycle test, and long duration thermal vacuum cycle test. The pre- and post-vibe thermal cycle and the long duration cycle test tested to hot and cold plateau initial temperatures of 40 °C, and -173 °C, respectively. The pre- and post-vibe tests required plateau holds of at least 2 hours, whereas the long duration cycle test required plateau holds of at least 20 hours. The tests each used a rate of temperature change of < 2 °C/min when transitioning between plateaus. The data collected from each thermal test is compared to show the operation of the TS both before and after the vibration test to GEVS levels, and throughout the long duration cycle test. From the data collected, the total conductance through the TS interfaces is calculated for both on (TS closed – during hot plateau) and off (TS open – during cold plateau) configurations, and the turndown ratio is also calculated. Challenges and lessons learned from the testing are also discussed.

thermal control technology↗

Intracranial Effects of Intermittent Lower Body Negative Pressure with Head Down Tilt Bed Rest: Comparison to Upright Posture

INTRODUCTION Spaceflight-associated neuro-ocular syndrome (SANS) affects a majority of astronauts during long-duration spaceflight. SANS is hypothesized to result from an unrelenting headward fluid shift that occurs in the microgravity environment. Altered intracranial structure and physiology documented in spaceflight and head-down tilt (HDT) experiments(1, 2) are also theorized to be related to chronic headward fluid shift and thereby can provide an independent quantitative assessment related to this mechanism. As a potential countermeasure, lower body negative pressure (LBNP) applied in the supine posture has shown efficacy in reducing headward fluid shift(3). However, it remains unknown if intermittent LBNP simulating daily upright posture fluid redistribution can mitigate SANS and intracranial changes associated with long-duration spaceflight. The goal of this study was to quantify the effects of daily application of LBNP or daily exposure to the upright posture on intracranial structure and physiology during long-term HDT in order to evaluate the potential efficacy of LBNP as a countermeasure to SANS. METHODS 22 healthy volunteers (11 men; 11 women; mean age = 35 years (SD=9.2)(age range = 24 to 52 years); mean BMI = 24.0 kg/m2 (SD=2.8)) completed an MRI study performed at the German Aerospace Facility in Cologne, Germany. Strict six-degree head-down tilt (HDT) bedrest was used as a spaceflight analog to induce a continuous headward fluid shift for 30 days. The subjects were divided equally into two groups of interventions: 1) LBNP for 3-hour sessions twice daily and 2) seated position for 3-hour sessions twice daily. Interventions were divided into morning and afternoon sessions for both groups. The LBNP intervention was maintained at 25 mmHg  2 mmHg. Pulse-gated MRI phase-contrast flow imaging was used to quantify cerebral artery stroke volume (CASV) and peak-to-peak cerebral spinal fluid (CSF) velocity (CSFVp-p) within the cerebral aqueduct. A 3D T1-MPRAGE sequence was used to quantify volumetric changes of the brain and intracranial CSF spaces using MRI Cloud software. MRI acquisitions were obtained at baseline (BDC, supine posture), 15 days into HDT (HDT15), 29 days into HDT (HDT29), and 12 days after recovery (R12, supine posture). The data were analyzed by a mixed model, which included intervention, time (four nominal levels BDC, HDT15, HDT29, R12), and intervention-time interaction as the fixed effects and included subject as a random effect. RESULTS Compared to BDC there was no statistically significant difference in CASV and CSFVp-p during HDT except for CASV at HDT29 (seated group) where there was a 1.7 mL (12%) decrease (P<0.01). Compared to BDC there was a statistically significant increase in intracranial volume (ICV; ICV = white matter + gray matter + CSF) for both interventions at HDT15 (Δ13 mL, 0.9 % (LBNP group); Δ15 mL, 1.0%, (seated group)) and HDT29 (Δ19 mL, 1.2%, (LBNP group); Δ23 mL, 1.5%) (seated group)) (All Ps<.001). Compared to baseline, lateral ventricular volume increased at HDT15 (Δ0.9 mL, 5.5%) and HDT29 (Δ1.8 mL, 10%)) for LBNP only (P=.001 for each). During HDT, white matter volume remained stable compared to baseline for both interventions. There were no significant intervention effects in the overall response to HDT (All Ps >.2). CONCLUSION LBNP had a similar response to the seated posture during 29 days of HDT. Although there was an increase in ICV and lateral ventricular volume with HDT there was no change in intracranial physiological parameters with LBNP suggesting an overall diminished response to the long-term effects of HDT. The lack of any significant increase in white matter volume during HDT with LBNP suggests maintenance of cerebral interstitial fluid transport. Final conclusions are pending the data collection for the control group (no intervention) which will be completed in 2023.

Larry A Kramer↗