Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

EVI-LOCATE User Manual

One of the longest stages in the deployment of electric vehicle supply equipment (EVSE) is the initial planning of the infrastructure itself. Engineers and fleet experts from the National Renewable Energy Laboratory (NREL) have supported dozens of charging infrastructure site plans over the past couple decades, including the generation of site schematics, determinations of electric capacity, and estimates for likely costs. As the market for electric vehicles (EVs) has matured, this approach should no longer require a time and personnel intensive process. In order to shorten the time taken to develop site plans and cost estimates, NREL developed a tool that fleet managers, facility managers, electricians, EVSE installers, and members of the public can use to develop initial schematics and ballpark pricing for charging station installations. The Electric Vehicle Infrastructure - Locally Optimized Charger Assessment Tool and Estimator (EVI-LOCATE) provides a structured and consistent way for users to enter information about their planned EVSE project in a relatively simple web-based format. EVI-LOCATE then calculates electrical equipment capacity, wiring runs, and project costs. It produces a site diagram optimized around surface characteristics with differential trenching costs for softscape such as grass compared to hardscape such as asphalt that can be adjusted by users in the tool. It also stores the resulting site plans and costs in a dashboard for access at a later date, including plan revisions if necessary. This document guides users through the EVI-LOCATE screens and associated questions. It contains tip text boxes throughout on how best to interface with the tool and find additional information or context. The appendices contain the assumptions and calculations underpinning the tool. Much of the information for EVI-LOCATE was gathered through industry engagements with EVSE installers, invoices from completed EVSE installations, Gordian's RS Means construction data, and the General Services Administration blanket purchase agreement for EVSE. For a visual tutorial of the tool, users can watch EVI-LOCATE Step-by-Step Video. The tool itself is available at https://evi-locate.nrel.gov.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Locating Partial Discharges in Power Transformers with Convolutional Iterative Filtering

The most common source of transformer failure is in the insulation, and the most prevalent warning signal for insulation weakness is partial discharge (PD). Locating the positions of these partial discharges would help repair the transformer to prevent failures. This work investigates algorithms that could be deployed to locate the position of a PD event using data from ultra-high frequency (UHF) sensors inside the transformer. These algorithms typically proceed in two steps: first determining the signal arrival time, and then locating the position based on time differences. This paper reviews available methods for each task and then propose new algorithms: a convolutional iterative filter with thresholding (CIFT) to determine the signal arrival time and a reference table of travel times to resolve the source location. The effectiveness of these algorithms are tested with a set of laboratory-triggered PD events and two sets of simulated PD events inside transformers in production use. Tests show the new approach provides more accurate locations than the best-known data analysis algorithms, and the difference is particularly large, 3.7X, when the signal sources are far from sensors.

47 OTHER INSTRUMENTATION↗

Simulated effect of defect volume and location on very high cycle fatigue of laser beam powder bed fused AlSi10Mg

This study quantifies the interaction between volumetric defect location and size on the very high cycle fatigue (VHCF) of laser beam powder bed fused (LB-PBF) AlSi10Mg. Crystal plasticity finite element method (CPFEM) simulations were used to investigate the effects of defect location and size on the driving force for crack initiation. The CPFEM model was calibrated against uniaxial and cyclic experimental data of LB-PBF AlSi10Mg. Defect characteristics were informed by experimental data from the specimens produced in various geometries to create realistic representative volume elements (RVEs) with equivalent volume fractions of defects. By embedding defects of varying sizes and locations within the RVEs, fatigue indicator parameters (FIPs) were calculated to analyze the impact of defects’ characteristics on fatigue performance. Different combinations of defect volume and locations were generated for various microstructure instantiations, providing insight into extreme value fatigue responses. Larger defect volumes located on free surfaces consistently generated the highest FIPs, suggesting defect size and boundary proximity intensify stress concentration effects. RVEs with multiple smaller defects produced lower FIPs than those with single large critical defects. These findings underscore the critical role of defect characteristics on fatigue life, providing a foundation for future predictive modeling in fatigue-sensitive AM applications.

AlSi10Mg↗

Locating Undocumented Wells Using Historical Oil and Gas Exploration Maps: A Case Study in Osage County, Oklahoma

Undocumented oil and gas wells lack reliable information about their locations and characteristics, making them difficult to identify. These wells can result in unanticipated delays and costs in the development of nearby surface and subsurface resources, and, if improperly plugged, can cause contamination. This study leverages historical petroleum exploration maps to locate such wells, focusing on Osage County, Oklahoma. Two sets of early 20th century oil and gas exploration maps by the United States Geological Survey were georeferenced and analyzed using a computer vision model to detect well symbols. The locations of detected wells were compared to the location of known wells in the database from the Bureau of Indian Affairs Osage Agency to identify potential undocumented wells. The analysis yielded over 500 potential undocumented wells, with dry holes constituting the largest fraction. Field verification confirmed the presence of some undocumented wells. Comparison with prior work revealed limited overlap, underscoring the complementary value of historical oil and gas maps for locating undocumented wells. This approach demonstrates the utility of integrating historical cartographic resources with modern geospatial and machine learning techniques to improve the identification and management of undocumented wells.

Energy - Petroleum↗

The effect of gas injection location on a lithium vapor box divertor in NSTX-U

Abstract The lithium vapor box divertor is a proposed divertor design that will minimize contamination of the upstream plasma in a fusion device, while also ensuring protection of the target. In this design lithium is evaporated near the target by high temperature lithium surfaces, dissipating the plasma heat flux. The lithium vapor box has been predicted via the fluid-kinetic code scrape off layer plasma simulator (SOLPS-ITER) to achieve low ( n L i / n e ∼ 0.05) upstream concentrations of lithium and low target heat fluxes. Here we compare two choices of deuterium gas puff location using SOLPS-ITER, the private flux region (PFR) and the common flux region (CFR), and find significant differences in the contamination level required to reach an acceptable target heat flux (defined here as q tar max ⩽ 10 MW m −2 ). Deuterium gas puffing from the PFR is seen to better reduce upstream lithium contamination. The difference in puffing location is seen to cause changes in the upstream flow of lithium ions. The PFR puff, having better access to the separatrix, can better reduce the upstream-directed flow of lithium near the separatrix which is the primary source of contamination due to a large thermal force in this region. Puffing from the CFR, partially due to inefficacy at reducing separatrix lithium flow, has higher lithium concentration within the plasma. Solutions that reduce the heat flux to below 10 MW m −2 have a range of lithium concentrations between n L i / n e ∼ 0.01–0.12 depending on puff intensity, location, evaporator temperature and recycling at the various plasma facing components. The efficacy of the puffs is tested for sensitivity to deuterium recycling coefficient at the target, evaporators, and main chamber walls. A CFR located puff is found to be more dependent on the recycling coefficients used than a PFR located puff. regardless of the set of recycling coefficients chosen, PFR puffing achieves lower lithium contamination than CFR puffing for a given heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LATTE: open-source, high-performance traveltime computation, tomography and source location in acoustic and elastic media

Traveltime-based tomography and source location are fundamental approaches for imaging subsurface structures and understanding the spatiotemporal distribution of seismicity from local to global scales. We present an open-source, high-performance framework integrating eikonal equation solvers and adjoint-state theory for traveltime computation, velocity tomography, source location and joint tomography-location in 2-D/3-D acoustic and elastic media. We introduce novel regularization schemes based on total generalized p-variation, structural similarity and multitask machine learning to enhance the fidelity and interpretability of inverted models and source locations. Key features of our implementation also include the ability to leverage both absolute-difference and double-difference traveltime misfits for high-fidelity velocity tomography and source parameter estimation; support for traveltime computation and inversion in diverse 2-D/3-D scenarios with arbitrary source and receiver distributions; and a perturbation-based optimal step-size estimation method to reduce computational costs. In addition, our implementation employs shared-memory and distributed-memory parallelization to provide an efficient solution for traveltime computation, tomography, and source location. In conclusion, we validate the efficacy and accuracy of our approach through multiple synthetic data examples.

58 GEOSCIENCES↗

A Scoping Study to Determine the Location-Specific WEC Threshold Size for Wave-Powered AUV Recharging

The aim of this study is to determine the threshold wave energy converter (WEC) type and size to charge a fleet of U.S. Navy autonomous underwater vehicles (AUVs) in various geographic locations of interest. The U.S. Navy deploys AUVs in locations around the world that must be charged manually, decreasing their operational endurance and creating operational limitations. Ocean waves are a potential power source that can be converted into electricity using a WEC and stored using a battery. It would be beneficial to develop a WEC that could autonomously charge AUVs offshore. Numerous locations were analyzed to determine the minimum size of a WEC capable of providing sufficient charging power and offering a strategic advantage. By predicting the WEC efficiency (based on empirical equations) and wave resource (based on available data), electrical power generation across numerous WEC types and locations was compared in MATLAB. The generalized process developed here could be used to determine the required size and type of WECs to charge a fleet of AUVs in different locations around the world.

16 TIDAL AND WAVE POWER↗

Biomass yield in a genetically diverse Miscanthus sacchariflorus germplasm panel phenotyped at five locations in Asia, North America, and Europe

Abstract Miscanthus is a high‐yielding bioenergy crop that is broadly adapted to temperate and tropical environments. Commercial cultivation of Miscanthus is predominantly limited to a single sterile triploid clone of Miscanthus × giganteus , a hybrid between Miscanthus sacchariflorus and M. sinensis. To expand the genetic base of M. × giganteus , the substantial diversity within its progenitor species should be used for cultivar improvement and diversification. Here, we phenotyped a diversity panel of 605 M. sacchariflorus from six previously described genetic groups and 27 M. × giganteus genotypes for dry biomass yield and 16 yield‐component traits, in field trials grown over 3 years at one subtropical location (Zhuji, China) and four temperate locations (Foulum, Denmark; Sapporo, Japan; Urbana, Illinois; and Chuncheon, South Korea). There was considerable diversity in yield and yield‐component traits among and within genetic groups of M. sacchariflorus , and across the five locations. Biomass yield of M. sacchariflorus ranged from 0.003 to 34.0 Mg ha −1 in year 3. Variation among the genetic groups was typically greater than within, so selection of genetic group should be an important first step for breeding with M. sacchariflorus . The Yangtze 2x genetic group (=ssp. lutarioriparius ) of M. sacchariflorus had the tallest and thickest culms at all locations tested. Notably, the Yangtze 2x genetic group's exceptional culm length and yield potential were driven primarily by a large number of nodes (>29 nodes culm −1 average over all locations), which was consistent with the especially late flowering of this group. The S Japan 4x, the N China/Korea/Russia 4x, and the N China 2x genetic groups were also promising genetic resources for biomass yield, culm length, and culm thickness, especially for temperate environments. Culm length was the best indicator of yield potential in M. sacchariflorus . These results will inform breeders' selection of M. sacchariflorus genotypes for population improvement and adaptation to target production environments.

59 BASIC BIOLOGICAL SCIENCES↗

Effective sensor location for detection of change in structural dynamic response

This paper investigates the sensitivity of structural system response to the sensor location by investigating consequences of small changes in the location to the structural system response. The paper discusses how maximum observability (based on mode shape and the participation of that mode in the input provided) drives optimal location. The structural responses were investigated in terms of the g-rms response for various low-frequency inputs (pure sinusoids and real-life inputs such as an earthquake and trains). Results were then analyzed in the context of Modal Contributions Factors (MCF) and changes to the Force-to-response Transfer Functions (TRFs). A modal-matching process is first presented using a Matlab TM -based Finite Element Method (FEM) model of a cantilever beam and instrumentation to determine the location of a small mass based on three different criteria. Subsequently, the structural response is investigated using experiments and the FEM model. The accelerometer of small mass (at 1/3 height) was moved up or down to obtain changes in the structural response (TRF) to various realistic low-frequency inputs. Modal Contribution Factor (MCF) and derivative (slope) of the associated mode-shapes were correlated to the observed changes in TRFs. Results show how optimal sensor locations for detecting change in structural response can be based on the MCFs and the associated mode-shapes.

Woodall, J.↗

Locating Operational Events of the Cooling Tower of a Nuclear Reactor with a Very Local Seismic Network

Geolocation of emergent seismic signals is challenging at close distances. Here, we used three-component data from a seismic network and a targeted experiment at a research nuclear reactor to locate seismic sources. Utilizing known events collected during the targeted experiment, we were able to infer source locations with seismic amplitudes and polarization characteristics of the data. Although the resolution of the source location is not perfect, the seismic amplitudes and polarization analysis offer useful constraints. For the known events, the source region inferred with our analysis includes the true source locations. Synthetic tests indicate the resolution is largely due to limited data coverage and measurement uncertainties because the synthetic tests show similar results compared with the field data. We identified the source of the unknown event through spectrum cross correlation between the signals from the known events and an unknown event. Our findings were confirmed by operational staff at the facility. When the propagation medium properties (i.e., seismic velocity and quality factor for attenuation) are known, our analysis can be applied to continuous data from a seismic array to infer both source amplitude and location. If the medium properties are not known, a targeted experiment can be conducted to estimate them.

58 GEOSCIENCES↗

Facility Location Optimization Model for COVID-19 Resources

In response to anticipated resource shortfalls related to the treatment and testing of COVID-19, many communities are planning to build additional facilities to increase capacity. These facilities include field hospitals, testing centers, mobile manufacturing units, and distribution centers. In many cases, these facilities are intended to be temporary and are designed to meet an immediate need. When deciding where to place new facilities many factors need to be considered, including the feasibility of potential locations, existing resource availability, anticipated demand, and accessibility between patients and the new facility. In this project, a facility location optimization model was developed to integrate these key pieces of information to help decision makers identify the best place, or places, to build a facility to meet anticipated resource demands. The facility location optimization model uses the location of existing resources and the anticipated resource demand at each location to minimize the distance a patient must travel to get to the resource they need. The optimization formulation is presented below. The model was designed to operate at the county scale, where patients are grouped per county. This assumption can be modified to integrate other scales or include individual patients.

60 APPLIED LIFE SCIENCES↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid AI-ML and FE-based Digital Twin Predictive Modeling Framework for a PWR Coolant System Components: Updates on Multi-Time-Series-3D-Location Dependent Usages Factor Prediction

The long-term operation (LTO) of nuclear power plants (NPP) beyond their original design life of 40 years can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition, the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Requiring frequent NDE inspections may lead to frequent NPP shutdowns which can lead to power outages and additional NDE inspection cost-related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing a more digital approach such as using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. The DT framework is based on limited experimental data, Artificial-intelligence (AI)-Machine-Learning (ML) and multiphysics-computationalmechanics such as finite element- (FE) based models. Given the real-time thermal-hydraulic process measurements from several existing plant sensors, the overall goal of the DT framework is to predict the cumulative usages factors or equivalent fatigue lives in real time and at any random 3D location of the components. This includes inaccessible locations such as inside the thickness or location of a component. This prediction can be at thousands to millions of 3D point clouds or locations like conventional FE-based models, but without running an FE model in real time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Seismoacoustic Source Location: Acoustic Approach

Seismic waves and infrasound are key technologies in the International Monitoring System (IMS) to monitor explosive events in the solid Earth and atmosphere. Energetic man-made or natural events (e.g., chemical/nuclear explosions, volcanic eruptions, and earthquakes) near the Earth’s surface produce both ground motion and atmospheric pressure disturbances which propagate as seismic waves and infrasound, respectively. Seismic waves have been generally used to detect and identify underground and near-surface events (Myers, et. al., 2007), and infrasound are sensitive to events near the surface or in the atmosphere (Modrak et. al., 2010). Due to their different sensitivities to events, they can complement to each other to improve the event detection and discrimination. The framework of joint seismoacoustic event location has recently reviewed by theoretical research (Koch and Arrowsmith, 2019). Although the early applications showed promising results to improve the accuracy of event location, their application were still limited to a small set of events selected to prove the concepts, and practical capability of the method for operational purpose is not fully evaluated with data. Our final goal is to apply the method of seismoacoustic event location to a larger set of events and evaluate its applicability for operational event location in practice. To that end, we focus on developing and verifying acoustic source location method in this study.

58 GEOSCIENCES↗

AquaPV: Regulatory and Environmental Considerations for Floating Photovoltaic Projects Located on Federally Controlled Reservoirs in the United States

To meet the nation's decarbonization goals, the U.S. Department of Energy's Solar Futures study forecasts that installed solar photovoltaic (PV) capacity must increase nearly tenfold, from 80 gigawatts (GW) in 2020 to approximately 760 GW cumulative installed capacity by 2035. Ground-mounted PV is expected to dominate future solar deployment and will require more than 3.5 million acres of land to meet annual demand projections (of nearly 45 GW) by 2030. However, various competing demands for land (e.g., agricultural production, conservation) and high land acquisition costs in specific locations could be challenges to meeting future PV demand solely with ground-mounted PV deployment. Floating photovoltaics (FPV) may be an alternative in locations where ground-mounted PV is not feasible and aid in reaching the nation's PV deployment and decarbonization goals. FPV is a newer siting approach in which a PV array is affixed to a floating apparatus and sited on a water body like a reservoir behind a dam. FPV systems may be stand-alone or co-located at new or existing hydroelectric facilities or pumped storage hydropower (PSH) facility reservoirs. Co-located FPV systems may or may not be operationally paired and work in tandem with the hydroelectric or PSH facility. This report provides novel analysis to understand the opportunities and challenges associated with developing stand-alone and co-located FPV projects on reservoirs in the United States. Specifically, the report explores potential environmental and energy benefits and environmental impacts associated with the siting, construction, and operation of FPV projects. The report also identifies and analyzes U.S. federal- and state-issued permits and authorizations required by federal laws to understand the licensing pathways and regulatory requirements for FPV projects sited on reservoirs licensed by the Federal Energy Regulatory Commission and on powered and non-powered reservoirs owned by the Bureau of Reclamation or U.S. Army Corps of Engineers.

13 HYDRO ENERGY↗

The Integration and Mapping of an Open-Source National Well Resource to Inform Geologic Carbon Storage Site Selection and Risk Prevention: The CO2-Locate Database

Geologic carbon storage (GCS) offers a way to capture and permanently store CO₂ from fossil fuel operations in underground geologic structures, aiding in the transition to a carbon-neutral energy economy. However, CO₂ injection sites can experience gas leakage through existing wells that penetrate storage reservoirs, making knowledge of well locations and characteristics crucial for permitting, infrastructure reusability, and risk assessment in GCS. Currently, public wellbore data from state, federal, and tribal entities are inconsistent and fragmented, with gaps and redundancies. To address this, the National Energy Technology Laboratory (NETL) developed CO2-Locate, an open-source, geospatial database and online application. CO2-Locate integrates over 50 data sources from federal, state, and tribal entities, creating a standardized national well database. Funded by the Bipartisan Infrastructure Law, the database is publicly available through the Energy Data eXchange (EDX) and viewable via the CO2-Locate web mapping application. This tool allows users to query, filter, and visualize well data to support GCS planning, permitting, and risk assessments. This presentation covers the methods used to create CO2-Locate, including data acquisition, processing, attribute mapping, and integration, much of which is automated for future updates. The web mapping application and its role in GCS site selection will also be discussed.

Tetteh, Daniel A.↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗