Reconciling Heliostat and Solar Panel Wind Loads To Develop a Reduced-Order Model for Heliostat Wind Loads

This work has been carried out as part of the HelioCon Field Deployment subtask, with the aim to distill published literature in papers and standards on heliostat and solar panel wind loads to develop a reduced order model for heliostat wind loads. It is intended to be understood and applied by structural engineers and heliostat designers as inputs to determine wind loads on heliostats due to the underlying derivations and factors that influence the complex structural dynamics and wind-induced behavior of heliostats.

14 SOLAR ENERGY

Thick shell tectonics on one-plate planets - Applications to Mars

Using the zero frequency equations of a self-gravitating elastic spherical shell overlying a strengthless fluid, a theory for stress distribution in thick lithospheric shells on one-plate planets is developed. For both the compensated and flexural modes, stress distributions in lithospheres are reviewed. For compensated modes, surface stresses depend only on surface topography, whereas for flexural modes it is shown that, for long wavelengths, stress trajectories are mainly dependent on the lithospheric lateral density distribution and not on elastic properties. Computational analyses are performed for Mars, and it is found that isostatically compensated models correctly predict the graben structure in the immediate Tharsis region and a flexural loading model is satisfactory in explaining the graben in the regions surrounding Tharsis. A three-stage model for the evolution of Tharsis is hypothesized: isostasy with north-south graben formation on Tharsis, followed by flexural loading and radial graben formation on the perimeter of Tharsis, followed by a last stage of loading with little or no regional deformation.

Banerdt, W. B.

LaRC design analysis report for National Transonic Facility for 9% nickel tunnel shell. Volume 1: Finite difference analysis of cone/cylinder junction

The results of extensive computer (finite element, finite difference and numerical integration), thermal, fatigue, and special analyses of critical portions of a large pressurized, cryogenic wind tunnel (National Transonic Facility) are presented. The computer models, loading and boundary conditions are described. Graphic capability was used to display model geometry, section properties, and stress results. A stress criteria is presented for evaluation of the results of the analyses. Thermal analyses were performed for major critical and typical areas. Fatigue analyses of the entire tunnel circuit are presented.

Ramsey, J. W., Jr.

LaRC design analysis report for National Transonic Facility for 304 stainless steel tunnel shell. Volume 1S: Finite difference analysis of cone/cylinder junction

The results of extensive computer (finite element, finite difference and numerical integration), thermal, fatigue, and special analyses of critical portions of a large pressurized, cryogenic wind tunnel (National Transonic Facility) are presented. The computer models, loading and boundary conditions are described. Graphic capability was used to display model geometry, section properties, and stress results. A stress criteria is presented for evaluation of the results of the analyses. Thermal analyses were performed for major critical and typical areas. Fatigue analyses of the entire tunnel circuit are presented.

Ramsey, J. W., Jr.

Solar Dynamic Power System Fault Diagnosis

The objective of this research is to conduct various fault simulation studies for diagnosing the type and location of faults in the power distribution system. Different types of faults are simulated at different locations within the distribution system and the faulted waveforms are monitored at measurable nodes such as at the output of the DDCU's. These fault signatures are processed using feature extractors such as FFT and wavelet transforms. The extracted features are fed to a clustering based neural network for training and subsequent testing using previously unseen data. Different load models consisting of constant impedance and constant power are used for the loads. Open circuit faults and short circuit faults are studied. It is concluded from present studies that using features extracted from wavelet transforms give better success rates during ANN testing. The trained ANN's are capable of diagnosing fault types and approximate locations in the solar dynamic power distribution system.

Momoh, James A.

Stability and Control Characteristics of a Model of an Aerial Vehicle Supported by Four Ducted Fans

The stability and control characteristics of a simple, lightly loaded model approximately one-third the size of a full-scale vehicle have been investigated by a series of free-flight tests. The model is representative of a type of vertically rising aircraft which would utilize four ducted fans as its sole source of lift and propulsion. The ducts were arranged in a rectangular pattern and were fixed to the airframe so that their axes of revolution were vertical for hovering flight. Control moments were provided by remotely controlled compressed-air jets at the sides and ends of the model. In hovering, the model in its original configuration exhibited divergent oscillations about both the roll and pitch axes. Because these oscillations were of a rather short period., the model was very difficult to control by the use of remote controls only. The model could be completely stabilized by the addition of a sufficient amount of artificial damping. The pitching oscillation was made easier to control by increasing the distance between the forward and rearward pairs of ducts. In forward flight, with the model in its original configuration, the top speed was limited by the development of an uncontrollable pitch-up. Large forward tilt angles were required for trim at the highest speeds attained. With the model rotated so that the shorter axis became the longitudinal axis, the pitch trim problem was found to be less than with the longer axis as the longitudinal axis. The installation of a system of vanes in the slipstream of the forward ducts reduced the tilt angle but increased the power required.

Parlett, Lysle P.

Influence of Strain-Gage Balance Characteristics on the Precision Error of the Drag Coefficient

Improvements and results of a new method are presented that computes a pre-test estimate of the precision error of the drag coefficient of a wind tunnel model. The error estimate is defined as the part of the drag coefficient's precision error that is primarily associated with the precision error of the angle of attack measurement and physical characteristics of the chosen strain-gage balance. The method indirectly describes the precision error of the angle of attack measurement by using an assumed balance gage output variation of one microV/V. The physical characteristics of the balance, on the other hand, are described by partial derivatives of the axial and normal forces with respect to the strain-gage outputs. These derivatives can directly be obtained from the data reduction matrix of the balance. The precision error estimate itself is calculated by applying a simple explicit equation that uses the model reference area, the dynamic pressure, the angle of attack, the coefficients of the linear terms of the data reduction matrix, and the electrical output variation of one microvolt per volt as input. Precision errors at constant angle of attack may be visualized as contour plots by plotting them, for example, versus the Mach number and the total pressure. Characteristics of NASA's MC60E balance are used in combination with the reference area of a generic wind tunnel model in order to demonstrate that error estimates are independent of both the balance load format and the units chosen for the description of balance loads, model reference area, and the dynamic pressure. Finally, experimental data from a wind tunnel test of the Ames Check Standard Model in the NASA Ames 11-foot Transonic Wind Tunnel illustrates the application of the method to real-world test data.

precision error

Hover in-ground-effect testing of a full-scale, tilt-nacelle V/STOL model

A full-scale, tilt-nacelle V/STOL aircraft model was tested in hover at the National Full Scale Aerodynamics Complex (NFAC), NASA Ames Research Center. The model was powered by two TF-34 turbofan engines. It was tested at several ground heights and control deflections. Test technique and test setup were documented. Limited results show that: (1) a small change in control power with ground height was measured, and control power was found to be good over + or - 20 deg of horizontal vane deflection; (2) integrated fuselage undersurface pressures, when compared with the total model loads and measured thrust, defined the effect of the fountain and its related flow field on model forces and moments; and (3) there was no indication of hot gas ingestion during simulated takeoff in calm winds from wheels on deck ground height.

Eshleman, J. E.

Hover in-ground-effect testing of a full-scale, tilt-nacelle V/STOL model

A full-scale, tilt-nacelle V/STOL aircraft model was tested in hover at the National Full Scale Aerodynamics Complex (NFAC), NASA Ames Research Center. The model was powered by two TF-34 turbofan engines. It was tested at several ground heights and control deflections. Test technique and test setup were documented. Limited results show that (1) a small change in control power with ground height was measured, and control power was found to be good over + or - 20 deg of horizontal vane deflection; (2) integrated fuselage undersurface pressures, when compared with the total model loads and measured thrust, defined the effect of the fountain and its related flow field on model forces and moments; and (3) there was no indication of hot gas ingestion during simulated takeoff in calm winds from wheels on deck ground height.

Eshleman, J. E.

Real-time hierarchically distributed processing network interaction simulation

The Telerobot Testbed is a hierarchically distributed processing system which is linked together through a standard, commercial Ethernet. Standard Ethernet systems are primarily designed to manage non-real-time information transfer. Therefore, collisions on the net (i.e., two or more sources attempting to send data at the same time) are managed by randomly rescheduling one of the sources to retransmit at a later time interval. Although acceptable for transmitting noncritical data such as mail, this particular feature is unacceptable for real-time hierarchical command and control systems such as the Telerobot. Data transfer and scheduling simulations, such as token ring, offer solutions to collision management, but do not appropriately characterize real-time data transfer/interactions for robotic systems. Therefore, models like these do not provide a viable simulation environment for understanding real-time network loading. A real-time network loading model is being developed which allows processor-to-processor interactions to be simulated, collisions (and respective probabilities) to be logged, collision-prone areas to be identified, and network control variable adjustments to be reentered as a means of examining and reducing collision-prone regimes that occur in the process of simulating a complete task sequence.

Zimmerman, W. F.

Aggregate data‐driven dynamic modeling of active distribution networks with DERs for voltage stability studies

Abstract Electric distribution networks increasingly host distributed energy resources based on power electronic converter (PEC) toward active distribution networks (ADN). Despite advances in computational capabilities, electromagnetic transient models are limited in scalability because of their reliance on exact data about the distribution system and each of its components. Similarly, the use of the DER_A model, which is intended to examine the combined dynamic behavior of many DERs, is limited by the difficulty in parameterization. There is a need for improved dynamic models of DERs for use in large power system simulations for stability analysis. This paper proposes an aggregate model‐free, data‐driven approach for deriving a dynamic partitioned model (DPM) of ADNs. Detailed residential distribution feeders were first developed, including PEC‐based DERs and composite load models (CMLDs), from which the aggregated DPM was derived. The performance was evaluated through various case studies and validated against the detailed ADN model and state‐of‐the‐art DER_A model with CMLD. The data‐driven DPM achieved a of over 90%, accurately representing the aggregated dynamic behavior of ADNs. Furthermore, the DPM significantly accelerated the simulation process with a computational speedup of 68 times compared to the detailed ADN and a 3.5 times speedup compared to the DER_A CMLD model.

42 ENGINEERING

The design of models for cryogenic wind tunnels

Factors to be considered in the design and fabrication of models for cryogenic wind tunnels include high model loads imposed by the high operating pressures, the mechanical and thermodynamic properties of materials in low temperature environments, and the combination of aerodynamic loads with the thermal environment. Candidate materials are being investigated to establish criteria for cryogenic wind tunnel models and their installation. Data acquired from these tests will be provided to users of the National Transonic Facility.

Gillespie, V. P.

GridLAB-D Technical Support Document: Residential Equivalent Thermal Parameter Model

GridLAB-D is a power distribution systems simulation and analysis tool developed by Pacific Northwest National Laboratory. Although GridLAB-D and its underlying residential load model has been used in a variety of power systems analyses, comprehensive documentation of the derivation of the residential house model has not been formally published. The purpose of this technical support document is to serve as a comprehensive resource for the thermal dynamics modeling and house definition implemented in GridLAB-D. It covers model derivation, parameter definitions, and implementation steps in the codebase.

24 POWER TRANSMISSION AND DISTRIBUTION

Design considerations of the national transonic facility

The inability of existing wind tunnels to provide aerodynamic test data at transonic speeds and flight Reynolds numbers was examined. The proposed transonic facility is a high Reynolds number transonic wind tunnel designed to meet the research and development needs of industry, and the scientific community. The facility employs the cryogenic approach to achieve high transonic Reynolds numbers at acceptable model loads and tunnel power. By using temperature as a test variable, a unique capability to separate scale effects from model aeroelastic effects is provided. The performance envelope of the facility is shown to provide a ten fold increase in transonic Reynolds number capability compared to currently available facilities.

Baals, D. D.

The negative gravity field over the 85 deg E ridge

Two north-south ridges in the basement topography of the Bay of Bengal may be observed on an isopach map at 85 and at 90 deg E. Free-air gravity anomaly profiles across the region show a strong gravity low (about -60 mGal) over the 85 deg E ridge, and a gravity high over the other. Using a simple two-stage loading model, the negative gravity anomaly over the 85 deg E ridge is explained as a direct consequence of sediment loading, and the flexural rigidity of the lithosphere when the ridge was formed is estimated to have been about 180 times less than the flexural rigidity during the sediment loading. An approximate relationship between flexural rigidity and crustal age shows that the 85 deg E ridge was formed on relatively young lithosphere, 5-15 million years old, and that it was buried when the lithosphere was 40-80 million years old. The alteration of the gravity field by a thick layer of sediments may occur in other large sedimentary basins or along continental margins.

Liu, C.-S.

High Fidelity Failure Analysis for a Composite Fuselage Section

A high fidelity delamination failure analysis was developed by combining a local failure analysis with a global full-scale finite element structural analysis to address strength and delamination failure in a single package. The methodology was demonstrated through a local three-dimensional pull-off failure analysis and a geometrically nonlinear structural analysis of a five-foot composite helicopter fuselage section. Pull-off specimens were used to identify potential debonding failure of co-cured skin-stringer/frame fuselage structures. An investigation of the failed pull-off specimens was performed to determine the location of the failure initiation. Three-dimensional strain energy release rate analysis indicates that the delamination initiation and growth is controlled by Mode 1 opening mode. The bending moment at the delamination tip was identified as the crucial factor controlling the failure. The geometrically nonlinear structural analysis of a five-foot composite fuselage section was performed using a detailed finite element model. Loads were applied along the periphery of the subcomponent using displacement fields generated from solutions of a full-vehicle model.

Li, Jain

Energy absorption mechanisms during crack propagation in metal matrix composites

The stress distributions around individual fibers in a unidirectional boron/aluminum composite material subjected to axial and transverse loadings are being studied utilizing a generalized plane strain finite element analysis. This micromechanics analysis was modified to permit the analysis of longitudinal sections, and also to incorporate crack initiation and propagation. The analysis fully models the elastoplastic response of the aluminum matrix, as well as temperature dependent material properties and thermal stress effects. The micromechanics analysis modifications are described, and numerical results are given for both longitudinal and transverse models loaded into the inelastic range, to first failure. Included are initially cracked fiber models.

Murphy, D. P.

Simulation of flight test conditions in the Langley pilot transonic cryogenic tunnel

The theory and advantages of the cryogenic tunnel concept are briefly reviewed. The unique ability to vary temperature independently of pressure and Mach number allows, in addition to large reductions in model loads and tunnel power, the independent determination of Reynolds number, Mach number, and aeroelastic effects on the aerodynamic characteristics of the model. Various combinations of Reynolds number and dynamic pressure are established to represent accurately flight variations of aeroelastic deformation with altitude changes. The consequences of the thermal and caloric imperfections of the test gas under cryogenic conditions were examined and found to be insignificant for operating pressures up to 5 atm. The characteristics of the Langley pilot transonic cryogenic tunnel are described and the results of initial tunnel operation are presented. Tests of a two-dimensional airfoil at a Mach number of 0.85 show identical pressure distributions for a chord Reynolds number of 8,600,000 obtained first at a stagnation pressure of 4.91 atm at a stagnation temperature of 322.0 K and then at a stagnation pressure of 1.19 atm at a stagnation temperature of 116.5 K.

Kilgore, R. A.