Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

Behavioral and Population Data-Driven Distribution System Load Modeling

Distribution system residential load modeling and analysis for different geographic areas within a utility or an independent system operator territory are critical for enabling small-scale, aggregated distributed energy resources to participate in grid services under Federal Energy Regulatory Commission Order No. 2222 [1]. In this study, we develop a methodology of modeling residential load profiles in different geographic areas with a focus on human behavior impact. First, we construct a behavior-based load profile model leveraging state-of-the-art appliance models. We simulate human activity and occupancy using Markov chain Monte Carlo methods calibrated with the American Time Use Survey data set. Second, we link our model with cleaned Current Population Survey data from the U.S. Census Bureau. Finally, we populate two sets of 500 households using California and Texas census data, respectively, to perform an initial analysis of the load in different geographic areas with various group features (e.g., different income levels). To distinguish the effect of population behavior differences on aggregated load, we simulate load profiles for both sets assuming fixed physical household parameters and weather data. Analysis shows that average daily load profiles vary significantly by income and income dependency varies by locality.

American Time Use Survey↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arctic Black Carbon Loading and Profile Using the Single-Particle Soot Photometer (SP2) Field Campaign Report

One of the major issues confronting aerosol climate simulations of the Arctic and Antarctic cryospheres is the lack of detailed data on the vertical and spatial distribution of aerosols with which to test these models. This is due, in part, to the inherent difficulty of conducting such measurements in extreme environments. However given the pronounced sensitivity of the polar regions to radiative balance perturbations, it is incumbent upon our community to better understand and quantify these perturbations, and their unique feedbacks, so that robust model predictions of this region can be realized. One class of under-measured radiative forcing agents in the polar region is the absorbing aerosol—black carbon and brown carbon. Black carbon (BC; also referred to as light-absorbing carbon [LAC], refractory black carbon [rBC], and soot) is second only to CO2 as a positive forcing agent. Roughly 60% of BC emissions can be attributed to anthropogenic sources (fossil fuel combustion and open-pit cooking), with the remaining fraction being due to biomass burning. Brown carbon (BrC), a major component of biomass burning, collectively refers to non-BC carbonaceous aerosols that typically possess minimal light absorption at visible wavelengths but exhibit pronounced light absorption in the near-ultraviolet (UV) spectrum. Both species can be sourced locally or be remotely transported to the Arctic region and are expected to perturb the radiative balance. The work conducted in this field campaign addresses one of the more glaring deficiencies currently limiting improved quantification of the impact of BC radiative forcing in the cryosphere: the paucity of data on the vertical and spatial distributions of BC. By expanding the Gulfstream aircraft (G-1) payload for the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility-sponsored ACME-V campaign to include the Single-Particle Soot Photometer (SP2)) and leveraging the ACME-V campaign’s deployment within the Arctic Circle during the summer of 2015 (Deadhorse, Alaska [70° 12' 20" N, 148° 30' 42" W]), the truly unique opportunity presented itself to acquire profile data on BC loading at little additional cost. Since the SP2 is a particle-resolved measurement, the resulting data set provides refractory black carbon (rBC) mass loadings, size and mass distributions, and rBC-containing particle mixing state, all of which are expected to readily find value in the modeling community. As part of the ACME-V (http://www.arm.gov/campaigns/aaf2014armacmev) campaign, CO, CO2, and CH4 were also measured, providing the unique opportunity for carbon closure. We will also work closely with modelers who require such data and expect this collaboration will lead directly to a better understanding of the climate impacts of BC in the Arctic. The primary measurement objective was to acquire airborne data on the vertical and spatial distributions of refractory black carbon (rBC) loading, size and mass distribution, and particle mixing state. The primary scientific objective was to provide a targeted data set of rBC particle distributions to better understand and constrain the impact of black carbon radiative forcing in the cryosphere. The SP2-based data set during this campaign is available in the DOE-ARM archive (http://www.arm.gov/campaigns/aaf2015abclp).

54 ENVIRONMENTAL SCIENCES↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transportation Electrification Load Development For a Renewable Future Analysis

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

02 PETROLEUM↗

Measurement of heat load density profile on acceleration grid in MeV-class negative ion accelerator

To understand the physics of the negative ion extraction/acceleration, the heat load density profile on the acceleration grid has been firstly measured in the ITER prototype accelerator where the negative ions are accelerated to 1 MeV with five acceleration stages. In order to clarify the profile, the peripheries around the apertures on the acceleration grid were separated into thermally insulated 34 blocks with thermocouples. The spatial resolution is as low as 3 mm and small enough to measure the tail of the beam profile with a beam diameter of ∼16 mm. It was found that there were two peaks of heat load density around the aperture. These two peaks were also clarified to be caused by the intercepted negative ions and secondary electrons from detailed investigation by changing the beam optics and gas density profile. This is the first experimental result, which is useful to understand the trajectories of these particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protecting Customer Privacy Through Distributed Energy Resource Anonymization

Due to their stochastic nature, the increase of Renewable Energy Resources (RERs) as a primary source of energy for power grids creates challenges regarding the reliability and resilience of the system. In order to combat these obstacles, expansion of Distributed Energy Resources (DERs) and their participation in Demand Response (DR) programs is necessary. Widespread participation requires prioritizing customer privacy and addressing concerns that may arise regarding communication between DERs and the Grid Service Provider (GSP). This paper discusses the use of flow reservation resources to split the operating cycles of DER load profiles into unique phases. The splitting of phases increases anonymization of the DERs by making it more difficult to determine the individual characteristics of the device. We discuss an example of this using simulated DER load profile data and examine the resulting effectiveness by using a machine learning algorithm for classification, called Support Vector Machine (SVM).

Distributed Energy Resource, Anonymization, Renewa↗

Adjustments and Uncertainty Quantification for SLS Aerodynamic Sectional Loads

This paper presents a method for adjusting sectional loads to match target values for integrated force and moment coefficients. In a typical application, the sectional load profile for one flight condition is calculated from Computational Fluid Dynamics (CFD) while the integrated forces and moments are measured in a wind tunnel experiment. These two methods do not generally result in identical predictions, and this leads to an inherent inconsistency between different data products. This paper aims to provide a procedure to remove that inconsistency. A sectional load profile for a launch vehicle splits the rocket into slices along its length and calculates the aerodynamic loading on each slice, which leads to a one-dimensional aerodynamic load profile that is used for structural analysis. Adjusting sectional loads, also known as line loads, is a nontrivial matter due to several consistency constraints. For example, the adjusted sectional normal force profile must be consistent with both the integrated normal force and pitching moment. To avoid such inconsistency issues, this paper presents a method using a Proper Orthogonal Decomposition (POD) to generate basis functions to adjust the sectional load profiles. As a corollary, this correction method enables the creation of an uncertainty quantification for sectional loads that is consistent with the dispersed integrated force and moment database and its uncertainty quantification. Several extensions to this technique, such as applying the method to the surface pressures, are considered.

Quantification↗

Data-Driven Load Diversity and Variability Modeling for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents a data-driven load modeling methodology for distribution system quasi-static time-series (QSTS) simulation considering both diversity and variability characteristics of distribution loads. Based on our previous work in [1]-[2], a variability library and diversity library have been established based on the realistic high-resolution data collected from actual utility feeders. Given the load profile for the start-of-circuit load of a feeder, the loads on the feeder nodes can be modeled with both diversity and variability instead of being directly scaled from the substation load profile according to the distribution allocation factors. With diversified load models, the load-induced impact on the feeder operation characteristics, such as voltage ramp and regulator operations, can be better considered in QSTS simulation. The proposed modeling methodology has been tested on both the IEEE 123-bus feeder and an actual utility feeder model, and the simulation results have demonstrated the merits of deploying the proposed load modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Load Diversity and Variability Modeling for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents a data-driven load modeling methodology for distribution system quasi-static time-series (QSTS) simulation considering both diversity and variability characteristics of distribution loads. Based on our previous work in [1]-[2], a variability library and diversity library have been established based on the realistic high-resolution data collected from actual utility feeders. Given the load profile for the start-of-circuit load of a feeder, the loads on the feeder nodes can be modeled with both diversity and variability instead of being directly scaled from the substation load profile according to the distribution allocation factors. With diversified load models, the load-induced impact on the feeder operation characteristics, such as voltage ramp and regulator operations, can be better considered in QSTS simulation. The proposed modeling methodology has been tested on both the IEEE 123-bus feeder and an actual utility feeder model, and the simulation results have demonstrated the merits of deploying the proposed load modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-life high performance fuel cell program

A multihundred kilowatt Regenerative Fuel Cell for use in a space station is envisioned. Three 0.508 sq ft (471.9 cm) active area multicell stacks were assembled and endurance tested. The long term performance stability of the platinum on carbon catalyst configuration suitability of the lightweight graphite electrolyte reservoir plate, the stability of the free standing butyl bonded potassium titanate matrix structure, and the long life potential of a hybrid polysulfone cell edge frame construction were demonstrated. A 18,000 hour demonstration test of multicell stack to a continuous cyclical load profile was conducted. A total of 12,000 cycles was completed, confirming the ability of the alkaline fuel cell to operate to a load profile simulating Regenerative Fuel Cell operation. An orbiter production hydrogen recirculation pump employed in support of the cyclical load profile test completed 13,000 hours of maintenance free operation. Laboratory endurance tests demonstrated the suitability of the butyl bonded potassium matrix, perforated nickel foil electrode substrates, and carbon ribbed substrate anode for use in the alkaline fuel cell. Corrosion testing of materials at 250 F (121.1 C) in 42% wgt. potassium identified ceria, zirconia, strontium titanate, strontium zirconate and lithium cobaltate as candidate matrix materials.

Martin, R. E.↗

Controller for thermostatically controlled loads

A system and method of controlling aggregated thermostatically controlled appliances (TCAs) for demand response is disclosed. A targeted load profile is formulated and a forecasted load profile is generated. The TCAs within an "on" or "off" control group are prioritized based on their operating temperatures. The "on" or "off" status of the TCAs is determined. Command signals are sent to turn on or turn off the TCAs.

25 ENERGY STORAGE↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Preventive Power Outage Estimation Based on A Novel Scenario Clustering Strategy: Preprint

The increasing occurrence of extreme weather events is challenging the power grid operation. In front of the extreme weather, the system operator is responsible for estimating the power outage and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The predicted vulnerable lines of an outage prediction model tool are utilized to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers the schedule of repair crews and mobile energy resources. Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative ones for straightforward analysis. Finally, case studies on a distribution system evaluate the damage level brought by extreme weather and verify the effectiveness of the proposed scenario clustering strategy.

mobile energy resources↗

Generation of Composite Load Protection Profiles for Reliable System Operation

A correct representation of the dynamic load is vital for power system planning and operation. In a composite load model, different motor types have different protection schemes. In addition, motor types vary significantly in different building type. Existing load models are inadequate to handle the growing importance of protective devices in buildings. This work proposed a methodology to generate composite protection profiles in one-hour interval in one year, for different commercial buildings in representative cities from different climate zones. This work can be used to develop the composite protection model, and to study the aggregated performance of the protection of all the motor loads in the composite load model.

protection model, Composite load model, Commercial↗

Optimized Renewable Energy Integration for EV High-Power Dynamic Wireless Charging Systems

Dynamic wireless charging for electric vehicles is an emerging technology to reduce on-board battery size and extend driving range. Due to its unique characteristic of vehicle-speed-related pulse-like load profile, the high-power dynamic wireless charging system (DWCS) introduces high stress to the utility grid. In this paper, an optimization model for renewable energy integration in the DWCS is proposed to mitigate the grid impact and minimize the operation costs of the whole system. As the load profile of DWCS is related to the traffic volume and various approaching vehicle speeds, the annual average daily traffic data and a stochastic model are used to develop 24-hour load profile of DWCS. To find a tradeoff between grid impact mitigation and operation costs minimization, relationships among power demand from power grid, photovoltaic (PV) capacity, wind energy (WE) capacity and energy storage (ES) capacity are analyzed, and the optimization objective and constraints are developed. Numerical simulation results demonstrate that energy storage integration can greatly mitigate the grid impact of DWCS, and optimal ratio of PV and WE can significantly reduce the operation cost of DWCS.

Zeng, Rong↗