Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Durable and Versatile Immobilized Carbonic Anhydrase on Textile Structured Packing for CO 2 Capture

High-performance carbon dioxide (CO 2 )-capture technologies with low environmental impact are necessary to combat the current climate change crisis. Durable and versatile “drop-in-ready” textile structured packings with covalently immobilized carbonic anhydrase (CA) were created as efficient, easy to handle catalysts for CO 2 absorption in benign solvents. The hydrophilic textile structure itself contributed high surface area and superior liquid transport properties to promote gas-liquid reactions that were further enhanced by the presence of CA, leading to excellent CO 2 absorption efficiencies in lab-scale tests. Mechanistic investigations revealed that CO 2 capture efficiency depended primarily on immobilized enzymes at or near the surface, whereas polymer entrapped enzymes were more protected from external stressors than those exposed at the surface, providing strategies to optimize performance and durability. Textile packing with covalently attached enzyme aggregates retained 100% of the initial 66.7% CO 2 capture efficiency over 71-day longevity testing and retained 85% of the initial capture efficiency after 1-year of ambient dry storage. Subsequent stable performance in a 500 h continuous liquid flow scrubber test emphasized the material robustness. Biocatalytic textile packings performed well with different desirable solvents and across wide CO 2 concentration ranges that are critical for CO 2 capture from coal and natural gas-fired power plants, from natural gas and biogas for fuel upgrading, and directly from air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Compressible foam electrode

A foam electrode comprising surface treatment by the steps of: 1) impregnating soft compressible polymeric foams with a conductive coating via sequential infiltration synthesis and 2) functionalizing the chemically altered voids with an ultrathin redox coating to enhance capacitive deionization (CDI). The redox coating will allow treated foam to absorb ions under the application of a bias, and mechanical compression/decompression. The CDI apparatus uses the void volume of the foam in the uncompressed state to flow liquids through it while the compressed state is used to enhance desalination by limiting the diffusion pathways for the ions to find an adsorption surface.

Young, Matthias John↗

Modular, disposable 3D printed microfluidic membrane system for separation and purification

The present disclosure relates to a membrane extraction apparatus for extracting a component from a first liquid. The apparatus may incorporate a housing comprised of first and second mating housing halves, with each housing half having an open faced channel formed therein such that the channels at least partially overlay one another when the two housing halves are secured together. A membrane filter is disposed between the two housing halves to overlay the open faced channels. The membrane filter extracts the component from the first liquid and transfers the component into the second liquid as the first and second liquids flow through the first and second housing halves.

Servis, Anna G.↗

Method and apparatus for desalinating water

This disclosure concerns a system and a method for removing dissolved solids from liquids. Specific implementations concern desalinating water. The system may comprise a blower, such as a thermal fan/compressor, configured to atomize a solid-bearing liquid to produce a hot, humid gas containing dissolved solids; a gas-solid separator configured to receive hot, humid gas containing entrained dissolved solids from the blower to separate the solids from the humid gas and to transmit the humid gas with solids removed through an exit port; a heater configured to heat the hot, humid gas received from the exit port of the gas-solid separator; and a condenser configured to receive heated humid gas from the heater and to condense solids-free liquid therefrom. The thermal fan/compressor may comprise a plurality of nozzles with outlets positioned adjacent atomization apertures across which a solid-bearing liquid flows and through which gas exiting the nozzles passes.

Abbasi, Bahman↗

Investigation of countercurrent flow profile and liquid holdup in random packed column with local CFD data

Liquid holdup and mass transfer area are critical parameters used in packed column design and CO 2 capture efficiency prediction. Compared to experimental methods, 3D computational fluid dynamics (CFD) can provide high-resolution data for studying countercurrent flow hydrodynamics in a packed column. In this paper, a framework was established for modeling the liquid–gas countercurrent flow in a random packed column with pall rings. Besides the column-averaged information, the radial pall ring distribution, velocity, and liquid holdup profiles are obtained in the simulations. The radial two-phase velocity and liquid holdup profiles show significant fluctuations caused by the non-uniform pall ring distribution. The entrance effect and wall influence are also observed in the packed column. By using local countercurrent flow information, the packing specific area $a_p$ and liquid velocity $u_L$ range are significantly expanded for liquid holdup hL prediction. This enables us to develop the liquid holdup correlation with one packing size and six CFD runs only. The proposed power law of the liquid holdup correlation $h_L~u_L^{0.44}$ indicates the random packed column falls in a viscous to turbulent transition regime with a Reynolds Number range of [6.7–40.2]. The derived liquid holdup correlation is in good agreement with existing correlations that are developed using the column-averaged experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical investigation of two-dimensional buoyancy-driven eddies in liquid metal magnetohydrodynamic flows in breeding blankets *

Abstract Lead–lithium flows are key features in the design of tokamak breeding blanket concepts such as the dual-coolant lead–lithium (DCLL). Since they flow under magnetic fields, they are affected by magnetohydrodynamic (MHD) effects. The neutron flux originating in the tokamak plasma heats the breeding blanket channels in a non-uniform manner, inducing buoyancy forces in the liquid metal. Buoyancy may become a source of quasi-two-dimensional (Q2D) turbulence, and the appearance of eddies may affect the transport of heat and tritium across the blanket. Blankets characterized by high-speed liquid metal flows (such as DCLL) will need ceramic insulating walls to reduce the MHD-related pressure drop in the channels. In our simulations, we have used the Q2D model proposed by Sommeria and Moreau (SM82) which is especially suitable for modeling electrically insulating channel flows. On top of that, we have modelled buoyancy forces in the momentum equation using the Oberbeck–Boussinesq approximation. In this work, we include a validation of the implemented Q2D model in buoyancy-driven cases and identify a thermohydraulic configuration that promotes the generation of eddies and the accumulation of tritium. We also show the results provided by our post-processing tool based on the bi-dimensional fast Fourier transform for eddy detection and characterization. We complete our investigation by performing an initial assessment of how eddies can accumulate tritium in the breeding blanket. We conclude by discussing the relevance of preventing accumulation of tritium within the blanket and suggest a possible solution.

Suarez, Daniel (ORCID:0000000251740100)↗

Dam-Break Flow Measurements of Liquid–Granular Mixtures in a Channelized Reservoir

Dam-break flows of granular materials exhibit a complex non-Newtonian rheology, which is strongly influenced by various factors, such as the characteristics of the granular material, the degree of initial compaction, and saturation level of the granular matrix. Specially adapted nonintrusive techniques are required to investigate these flows in the laboratory. This paper investigated the nonintrusive technique of image analysis. The methodologies used in the measurement of bulk flow parameters, such as flow depth, front velocity, and flow rate, and the extraction of detailed flow characteristics such as velocity profiles, were discussed in the context of a series of granular dam-break flow experiments. These experiments were performed under three types of initial conditions: dry, saturated (water filling the pore space), and submerged (a layer of saturated granular material submerged under water) using four types of granular materials—PET pellets, crushed walnut shells, urea, and sand—with grain sizes ranging from 200 μm to 2.9 mm. High-speed cameras were used to capture the evolution and local properties of the flow, such as velocity fields using particle image velocimetry (PIV). Bulk properties of the flow were obtained by tracking the surface profile of the granular matrix and the water table. The extracted profiles were used to measure the evolution of the volume of the granular matrix and the fluid phase separately upstream and downstream of the gate, which allowed measuring the dilatancy (increase in pore space). The study showed that the image analysis techniques are versatile and can be adapted to measure different flow parameters in a variety of granular flows to better understand and analyze their complex behavior. Finally, the advantages and drawbacks of each image analysis technique were discussed and best-practice recommendations were provided.

42 ENGINEERING↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Laminar drag reduction in microchannels with liquid infused textured surfaces

Liquid infused surfaces (LIS) achieve non-wetting properties through asperity structures containing pockets of a lubricating liquid rather than air. Although studies have demonstrated several potential applications of LIS, the effect of liquid infused texture on the flow of liquid in microchannels has not been systematically addressed. The present work focuses on the effect of liquid-infused texture geometry and the infused liquid properties on the flow characteristics of a bulk fluid in rectangular and round microchannel geometries. Considering four different textured geometries of transverse ridges, longitudinal ridges, in-lined square posts and staggered squares, a detailed parametric study is presented to assess the resulting drag reduction and friction factor, expressed in terms of the Poiseuille number, on the flow in microchannels. The effect of geometrical parameters is investigated for different asperity solid fraction (Φ s ), asperity height (h s ) and channel thickness (H) or tube diameter (D), while the effect of the infused fluid is studied in terms of a ratio of its viscosity relative to the viscosity of the flowing bulk fluid. Based on the results of the parametric study an extension of the conventional Moody diagram for non-wetting surfaces is developed. Finally, a design of experiments study is conducted to relate the drag reduction and Poiseuille number to the various governing parameters, using which conditions that maximize drag reduction are identified.

42 ENGINEERING↗

Feasibility of X-ray scattering for tracer-free liquid-phase thermometry for multiphase flows

The feasibility of liquid temperature measurements using X-ray scattering is investigated for liquids with varying properties (water, ethanol, and n-dodecane) on beamline 7-BM at the Advanced Photon Source at Argonne National Laboratory. The temperature is inferred through the change in the scattering pattern from the liquid as a function of temperature using partial least squares regression. An accuracy of ~98% or higher was achieved enabling measurements for a wide range of applications.

42 ENGINEERING↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TEMPO allegro: liquid catholyte redoxmers for nonaqueous redox flow batteries

Redoxmers are organic active molecules storing energy in redox flow batteries (RFBs). Liquid redoxmers represent an extreme scenario where maximum concentration may be achieved by minimizing supporting solvents, thus maximizing the energy density of RFBs. Herein, a series of (2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO)-based high potential (catholyte) liquid redoxmers, TEMPO-EG1, TEMPO-EG2, and TEMPO-EG3, were developed by incorporating polyethylene glycol (PEG) chains. Such modifications not only afford dramatic physical changes from solid to liquid and full miscibility in acetonitrile, but also impact the redox behavior. DFT calculations indicate that the incorporated PEG chains impact the charge distribution, which may account for the electrochemical changes. Importantly, compared to our previous liquid catholytes, the new redoxmers exhibit lower viscosity, which is desired for enhancing high concentration cycling performance. Furthermore, by using a hybrid flow cell, TEMPO-EG1 demonstrated more than 70% capacity retention over 100 cycles at 0.1 M and 66% capacity retention at 0.5 M, affording excellent cyclability at various concentrations. The study exemplifies how molecular engineering tuned the rheological properties of redoxmers, such as viscosity, to improve the high concentration cycling performance of RFBs, which may represent a promising avenue for a high energy density and low-cost flow battery system.

25 ENERGY STORAGE↗