Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LabVIEW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An experimental investigation of the effectiveness of Ar-CO 2 shielding gas mixture for the wire arc additive process

Wire arc additive manufacturing (AM) is the process by which a large, metallic structure is built layer-by-layer using a welding arc to melt a wire feedstock. A novel opportunity exists to alter the shielding gas composition to fabricate distinct geometrical features without altering the other AM parameters. In this paper, shielding gases with varied concentrations of Argon (Ar) and CO 2 was used to deposit three distinct geometric shapes (walls, infill, and overhang) using a wire-based additive manufacturing system utilizing the gas metal arc welding (GMAW) surface tension transfer (STT) process. Computer-aided design (CAD) models were sliced with a custom-built slicer, and the sliced algorithm was converted into optimal robotic toolpaths. A custom virtual instrument (VI) was built in LabVIEW to compare the temperature profiles on the surface during each deposition process. After each deposition, the geometric features were scanned, and the surface waviness value was evaluated. Tensile and Charpy impact coupons were extracted from the wall geometries in the longitudinal and transverse directions and tested. The results indicated that a higher CO 2 content produced higher melt pool temperatures to an extent, while lower contents of CO 2 resulted in a dimensionally accurate geometry. The data also indicated that the 2%/98% CO 2 /Ar blend produced scatter in tensile strength and the analysis of variance (ANOVA) shows significant difference. However, the intermediate range of CO 2 (5–10%) resulted in uniform tensile properties. Altogether, these results indicate that a 5%/95% CO 2 /Ar blend is the ideal shielding gas for lowering process temperatures and improving mechanical properties in wire arc additive manufacturing using the gas metal arc welding surface tension transfer process. Additionally, varying concentrations of Ar/CO 2 can be used within the same part in order to modify the local properties or process parameters such as strength, toughness, temperature, or dimensional features. This may improve overall manufacturing quality without sacrificing specific properties.

42 ENGINEERING↗

Ppb-level mid-infrared ethane detection based on three measurement schemes using a 3.34-μm continuous-wave interband cascade laser

A ppb-level mid-infrared ethane (C 2 H 6 ) sensor was developed using a continuous-wave, thermoelectrically cooled, distributed feedback interband cascade laser emitting at 3.34 μm and a miniature dense patterned multipass gas cell with a 54.6-m optical path length. The performance of the sensor was investigated using two different techniques based on the tunable interband cascade laser: direct absorption spectroscopy (DAS) and second-harmonic wavelength modulation spectroscopy (2f-WMS). Three measurement schemes, DAS, WMS and quasi-simultaneous DAS and WMS, were realized based on the same optical sensor core. A detection limit of ~7.92 ppbv with a precision of ±30 ppbv for the separate DAS scheme with an averaging time of 1 s and a detection limit of ~1.19 ppbv with a precision of about ±4 ppbv for the separate WMS scheme with a 4-s averaging time were achieved. An Allan–Werle variance analysis indicated that the precisions can be further improved to 777 pptv @ 166 s for the separate DAS scheme and 269 pptv @ 108 s for the WMS scheme, respectively. For the quasi-simultaneous DAS and WMS scheme, both the 2f signal and the direct absorption signal were simultaneously extracted using a LabVIEW platform, and four C 2 H 6 samples (0, 30, 60 and 90 ppbv with nitrogen as the balance gas) were used as the target gases to assess the sensor performance. A detailed comparison of the three measurement schemes is reported. Here, atmospheric C 2 H 6 measurements on the Rice University campus and a field test at a compressed natural gas station in Houston, TX, were conducted to evaluate the performance of the sensor system as a robust and reliable field-deployable sensor system.

47 OTHER INSTRUMENTATION↗

Compact automated apparatus for rapid astatine recovery from nitric acid media: Design, application, and impurity characterization

We report automation of irradiated bismuth target dissolution and astatine recovery from nitric acid media has been achieved at Texas A&M University. This process can be controlled remotely; it does not require any chemical treatment or evaporation of dissolution solution prior to the separation of above-mentioned elements on an extraction chromatography column, making the final product ready within 20 min. The accompanying radio-impurities have been identified and successfully separated from astatine, leading to greater than 99% radiopurity of the desired fractions. The system consists of only one pump and a set of LabVIEW controlled valves, and allows the connection of up to 10 different columns, providing the opportunity to prepare a variety of air dry columns, which can be different column geometries, containing astatine ready for further chemistry or shipment to desired facilities.

42 ENGINEERING↗

Thermal effects of an ICL-based mid-infrared CH 4 sensor within a wide atmospheric temperature range

Here, thermal effects of an interband cascade laser (ICL) based mid-infrared methane (CH 4 ) sensor that uses long-path absorption spectroscopy were studied. The sensor performance in the laboratory at a constant temperature of ~ 25°C was measured for 5 hours and its Allan deviation was ~ 2 ppbv with a 1 s averaging time. A LabVIEW-based simulation program was developed to study thermal effects on infrared absorption and a temperature compensation technique was developed to control such effects. An environmental test chamber was employed to investigate thermal effects that occur in the sensor system with variation of the test chamber temperature between 10 and 30°C. The thermal response of the sensor in a laboratory setting was observed using a 2.1 ppm CH 4 standard gas sample. indoor/outdoor CH 4 measurements were conducted to evaluate the sensor performance within a wide atmospheric temperature range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a pepper pot emittance probe and its application for ECR ion beam studies.

A pepper pot-scintillator screen system has been developed and used to measure the emittance of DC ion beams extracted from a high-intensity permanent magnet ECR ion source. The system includes a fast beam shutter with a minimum dwell time of 18 ms to reduce the degradation of the CsI(Tl) scintillator by DC ion beam irradiation and a CCD camera with a variable shutter speed in the range of 1 {micro}s-65 s. On-line emittance measurements are performed by an application code developed on a LabVIEW platform. The sensitivity of the device is sufficient to measure the emittance of DC ion beams with current densities down to about 100 nA/cm{sup 2}. The emittance of all ion species extracted from the ECR ion source and post-accelerated to an energy of 75-90 keV/charge have been measured downstream of the LEBT. As the mass-to-charge ratio of ion species increases, the normalized RMS emittances in both transverse phase planes decrease from 0.5-1.0 {pi} mm mrad for light ions to 0.05-0.09 {pi} mm mrad for highly charged {sup 209}Bi ions. The dependence of the emittance on ion's mass-to-charge ratio follows very well the dependence expected from beam rotation induced by decreasing ECR axial magnetic field. The measured emittance values cannot be explained by only ion beam rotation for all ion species and the contribution to emittance of ion temperature in plasma, non-linear electric fields and non-linear space charge is comparable or even higher than the contribution of ion beam rotation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental Studies of Light Emission Phenomena in Superconducting RF Cavitites

Experimental studies of light emission phenomena in superconducting RF cavities, which we categorize under the general heading of cavity lights, are described. The cavity lights data, which were obtained using a small CCD video camera, were collected in a series of nine experimental runs ranging from {approx} 1/2 to {approx} 2 h in duration. The video data were recorded on a standard VHS tape. As the runs progressed, additional instrumentation was added. For the last three runs a LabVIEW controlled data acquisition system was included. These runs furnish evidence for several, possibly related, light emission phenomena. The most intriguing of these is what appear to be small luminous objects {le} 1.5 mm in size, freely moving about in the vacuum space, generally without wall contact, as verified by reflections of the tracks in the cavity walls. In addition, on a number of occasions, these objects were observed to bounce off of the cavity walls. The wall-bounce aspect of most of these events was clearly confirmed by pre-bounce and post-bounce reflections concurrent with the tracks. In one of the later runs, a mode of behavior was observed that was qualitatively different from anything observed in the earlier runs. Perhaps the most perplexing aspect of this new mode was the observation of as many as seven luminous objects arrayed in what might be described as a macromolecular formation, coherently moving about in the interior of the cavity for extended periods of time, evidently without any wall contact. It is suggested that these mobile luminous objects are without explanation within the realm of established physics. Some remarks about more exotic theoretical possibilities are made, and future plans are discussed.

43 PARTICLE ACCELERATORS↗

The CDMS II data acquisition system

The Data Acquisition System for the CDMS II dark matter experiment was designed and built when the experiment moved to its new underground installation at the Soudan Lab. The combination of remote operation and increased data load necessitated a completely new design. Elements of the original LabView system remained as stand-alone diagnostic programs, but the main data processing moved to a VME-based system with custom electronics for signal conditioning, trigger formation and buffering. The data rate was increased 100-fold and the automated cryogenic system was linked to the data acquisition. A modular server framework with associated user interfaces was implemented in Java to allow control and monitoring of the entire experiment remotely.

99 GENERAL AND MISCELLANEOUS↗

A flexible data acquisition system architecture for the Nab experiment

Here, the Nab experiment will measure the electron–neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model physics. Using National Instrument’s PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab’s specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at a rate of at least 1 MHz, while reading out a peak signal rate of approximately 2 GB/s. During the commissioning phase of the experiment, the system ran at a sustained readout rate of 400 MB/s of detector signal data originating from roughly 6 kHz L2 triggers, well within the peak performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in the development of wire mesh reactor for coal gasification studies - article no. 084102

In an effort to further understand the coal gasification behavior in entrained-flow gasifiers, a high pressure and high temperature wire mesh reactor with new features was recently built. An advanced LABVIEW-based temperature measurement and control system were adapted. Molybdenum wire mesh with aperture smaller than 70 {mu} m and type D thermocouple were used to enable high carbon conversion ({gt}90%) at temperatures {gt}1000 {sup o}C. Gaseous species from wire mesh reactor were quantified using a high sensitivity gas chromatography. The material balance of coal pyrolysis in wire mesh reactor was demonstrated for the first time by improving the volatile's quantification techniques.

01 COAL, LIGNITE, AND PEAT↗

Automated gas burette system for evolved hydrogen measurements

This paper reports a simple and efficient gas burette system that allows automated determination of evolved gas volume in real time using only temperature and pressure measurements. The system is reliable and has been used successfully to study the hydrogen release kinetics of ammonia borane thermolysis. The system is especially suitable for bench scale studies involving small batches and potentially rapid reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Q-Switched Nd: YAG Laser Micro-Machining System

In this paper, we present the design of a low cost Q-switched Nd: YAG laser micro-machining system for photo masks fabrication. It consists of: Nd:YAG laser source, beam delivery system, X-Y table, PC, The CCD camera and TV monitor. The synchronization between the laser source and the X-Y table is realised by NI PCI-7342, the two axis MID-7602 and LabVIEW based program. The first step of this work consists of engraving continuous and discontinuous lines on a thin film metal with a 100 {mu}m resolution by using the YG 980 Quantel Q-switched Nd:YAG laser.

36 MATERIALS SCIENCE↗

Control system for the Spallation Neutron Source H{sup -} source test facility Allison scanner

Spallation Neutron Source is currently in progress of a multiyear plan to ramp ion beam power to the initial design power of 1.4 MW. Key to reaching this goal is understanding and improving the operation of the H{sup -} ion source. An Allison scanner was installed on the ion source in the test facility to support this improvement. This paper will discuss the hardware and the software control system of the installed Allison scanner. The hardware for the system consists of several parts. The heart of the system is the scanner head, complete with associated bias plates, slits, and signal detector. There are two analog controlled high voltage power supplies to bias the plates in the head, and a motor with associated controller to position the head in the beam. A multifunction data acquisition card reads the signals from the signal detector, as well as supplies the analog voltage control for the power supplies. To synchronize data acquisition with the source, the same timing signal that is used to trigger the source itself is used to trigger data acquisition. Finally, there is an industrial personal computer to control the rest of the hardware. Control software was developed using National Instruments LABVIEW, and consists of two parts: a data acquisition program to control the hardware and a stand alone application for offline user data analysis.

43 PARTICLE ACCELERATORS↗

Design of microcontroller based system for automation of streak camera

A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

Optimization Of A Mass Spectrometry Process

In this paper we present and discuss a system developed in order to optimize the mass spectrometry process of an ion implanter. The system uses a PC to control and display the mass spectrum. The operator interacts with the I/O board, that interfaces with the computer and the ion implanter by a LabVIEW code. Experimental results are shown and the capabilities of the system are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗