Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEAKAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building.The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference.Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five isomers of the PFT PDCH (mtPDCH, pcPDCH, otPDCH, mcPDCH, and ptPDCH). These isomers were quantified in the low concentration samples in the Alpha test and in all samples in the Bravo test.The best estimates of UI (Rui) for the four zones are provided in Table ES-1. For the CB, this estimate averages the four tracers at the four elevations. For the CR, this estimate uses the four sampling units located in the Control Room.

54 ENVIRONMENTAL SCIENCES↗

Reduced-Order Model for Leakage Through an Open Wellbore from the Reservoir due to Carbon Dioxide Injection

Potential CO 2 leakage through existing open wellbores is one of the most significant hazards that need to be addressed in geologic carbon sequestration (GCS) projects. In the framework of the National Risk Assessment Partnership (NRAP) which requires fast computations for uncertainty analysis, rigorous simulation of the coupled wellbore-reservoir system is not practical. We have developed a 7,200-point look-up table reduced-order model (ROM) for estimating the potential leakage rate up open wellbores in response to CO 2 injection nearby. The ROM is based on coupled simulations using T2Well/ECO2H which was run repeatedly for representative conditions relevant to NRAP to create a look-up table response-surface ROM. The ROM applies to a wellbore that fully penetrates a 20-m thick reservoir that is used for CO 2 storage. The radially symmetric reservoir is assumed to have initially uniform pressure, temperature, gas saturation, and brine salinity, and it is assumed these conditions are held constant at the far-field boundary (100 m away from the wellbore). In such a system, the leakage can quickly reach quasi-steady state. The ROM table can be used to estimate both the free-phase CO 2 and brine leakage rates through an open well as a function of wellbore and reservoir conditions. Results show that injection-induced pressure and reservoir gas saturation play important roles in controlling leakage. Caution must be used in the application of this ROM because well leakage is formally transient and the ROM lookup table was populated using quasi-steady simulation output after 1000 time steps which may correspond to different physical times for the various parameter combinations of the coupled wellbore-reservoir system.

54 ENVIRONMENTAL SCIENCES↗

NRAP Recommended Practices for Containment Assurance and Leakage Risk Quantification

This report presents recommendations for quantitatively assessing and managing leakage risk and effective containment assurance at geologic carbon storage (GCS) sites, amidst uncertainty in site characteristics and performance. These recommended practices are a product of the U.S. Department of Energy’s (DOE) Office of Fossil Energy and Carbon Management’s National Risk Assessment Partnership (NRAP)—a multi-year collaborative research effort of Lawrence Berkeley National Laboratory, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, National Energy Technology Laboratory, and Pacific Northwest National Laboratory. These recommended practices are organized as a set of conceptual workflows that correspond with the stages of the GCS project lifecycle. They consider aspects of site characterization, quantification of potential leakage, assessing the spatial extent of potential environmental impacts, optimizing monitoring design for detection of potential leakage, evaluation of concordance between monitored and forecasted reservoir response, assessing conformance with expected/accepted performance, and determination of the timeline over which risk of impactful leakage can be expected to abate. These conceptual workflows are intended to aid stakeholders in making risk management decisions at GCS sites and to support development of sound, risk-based justifications for characterizing the subsurface, defining area of potential leakage impact, designing site monitoring plans, selecting leakage risk management/mitigation alternatives, and estimating site closure timelines.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those found in for the pressure station approach. Walker and Dickerhoff also included estimates of DeltaQ test repeatability based on the results of field tests where two houses were tested multiple times. The two houses were quite leaky (20-25 Air Changes per Hour at 50Pa (0.2 in. water) (ACH50)) and were located in the San Francisco Bay area. One house was tested on a calm day and the other on a very windy day. Results were also presented for two additional houses that were tested by other researchers in Minneapolis, MN and Madison, WI, that had very tight envelopes (1.8 and 2.5 ACH50). These tight houses had internal duct systems and were tested without operating the central blower--sometimes referred to as control tests. The standard deviations between the multiple tests for all four houses were found to be about 1% of the envelope air flow at 50 Pa (0.2 in. water) (Q50) that led to the suggestion of this as a rule of thumb for estimating DeltaQ uncertainty. Because DeltaQ is based on measuring envelope air flows it makes sense for uncertainty to scale with envelope leakage. However, these tests were on a limited data set and one of the objectives of the current study is to increase the number of tested houses. This study focuses on answering two questions: (1) What is the uncertainty associated with changes in weather (primarily wind) conditions during DeltaQ testing? (2) How can these uncertainties be reduced? The first question is addressing issues of repeatability. To study this five houses were tested as many times as possible over a day. Weather data was recorded on-site--including the local windspeed. The result from these five houses were combined with the two Bay Area homes from the previous studies. The variability of the tests (represented by the standard deviation) is the repeatability of the test method for that house under the prevailing weather conditions. Because the testing was performed over a day a wide range of wind speeds was achieved following typical diurnal variations of low wind in the early morning and greatest winds in the late afternoon/early evening. Typically about ten tests were performed in each house. To answer the second question, different data analysis techniques were investigated that looked at averaging techniques, elimination of outliers, limiting leak pressures, etc. in order to minimize the influence of changing wind conditions during the test. The objective was to find a reasonable compromise between test precision and robustness--because many of the changes to the analysis to make the test more robust limit its ability to examine wide ranges of pressures and leakage flows. A secondary goal of this study is to show that DeltaQ uncertainties are acceptable for testing low leakage systems. Therefore houses with low duct leakage were deliberately chosen to be tested.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient High-Pressure Turbine Leakage Technology Report

The leakage test program was one of such supporting technology programs structured to provide guidance to the Energy Efficient Engine High Pressure Turbine Component Design Effort. Leakage reduction techniques were identified and evaluated. Test models were used to simulate component leak paths and to evaluate leakage reduction techniques. These models simulated the blade/disk attachment, the vane inner platform attachment, and the vane outer platform attachment combined with the blade outer airseal. Disk blade attachment testing indicated that leakage in this area could be reduced to very low levels by paying careful attention to the tolerances along the contact surface between the blade vibration damper and the blade platform contact surface. The aim of feather seal testing was to achieve a goal for an effective leakage gap of one mil (.001 inch) per inch of feather seal length. Results indicated that effective gaps even below the goal level were achievable by (1) maintaining close tolerances between feather seals and their slots to minimize end gaps and limit seal rotation, (2) avoiding feather seal overlap, and (3) minimizing feather seal intersections. W seals were shown to be effective leakage control devices. Wire rope, in its present state of development, was shown not to be an effective sealing concept for application to the component design.

Gardner, W. B.↗

The SSME seal test program: Leakage tests for helically-grooved seals

Helically grooved annular seal configurations were tested in highly turbulent flow to determine if reduced leakage and enhanced stability would result from the pumping action of the seal. It was found that: (1) leakage of a helically grooved seals decreases with running speed; (2) leakage reduction due to increased running speed is greater at lower values of R sub a; (3) an asymptote for leakage reduction is indicated with increasing running speed; (4) leakage is reduced by reducing the ridge (minimum) and average clearances; (5) leakage increases with increasing pitch angles and with increasing groove depth. Plain seals with smooth rotors and stators will leak more than a helically grooved seal. It was also found that plain seals with a rough rotor and a rough stator leak less than a properly designed helically grooved seal. A properly designed helically grooved seal consumes at least twice as much power as a conventional annular seal.

Childs, D. W.↗

Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

Lueders, Kathy↗

Nonlinear Acoustics Used To Reduce Leakage Flow

Leakage and wear are two fundamental problems in all traditional turbine seals that contribute to an engine's inefficiency. The solutions to seal leakage and wear conflict in the conventional design space. Reducing the clearance between the seal and rotating shaft reduces leakage but increases wear because of increased contact incidents. Increasing the clearance to reduce the contact between parts reduces wear but increases parasitic leakage. The goal of this effort is to develop a seal that restricts leakage flow using acoustic pressure while operating in a noncontacting manner, thereby increasing life. In 1996, Dr. Timothy Lucas announced his discovery of a method to produce shock-free high-amplitude pressure waves. For the first time, the formation of large acoustic pressures was possible using dissonant resonators. A pre-prototype acoustic seal developed at the NASA Glenn Research Center exploits this fundamental acoustic discovery: a specially shaped cavity oscillated at the contained fluid's resonant frequency produces high-amplitude acoustic pressure waves of a magnitude approaching those required of today's seals. While the original researchers are continuing their development of acoustic pumps, refrigeration compressors, and electronic thermal management systems using this technology, the goal of researchers at Glenn is to apply these acoustic principles to a revolutionary sealing device. When the acoustic resonator shape is optimized for the sealing device, the flow from a high-pressure cavity to a low-pressure cavity will be restricted by a series of high-amplitude standing pressure waves of higher pressure than the pressure to be sealed. Since the sealing resonator cavity will not touch the adjacent sealing structures, seal wear will be eliminated, improving system life. Under a cooperative agreement between Glenn and the Ohio Aerospace Institute (OAI), an acoustic-based pre-prototype seal was demonstrated for the first time. A pressurized cavity was attached to one end of the resonator while the other end remained open to ambient pressure. Measurements were taken at several values of applied pressure with the assembly stationary, oscillated at an off-resonance frequency, and then oscillated on-resonance. The three cases show that the flow through the conical resonator can be reduced by oscillating the resonator at the resonance frequency of the air contained within the cavity. The results are currently being compared with results obtained from a commercial computational fluid dynamics code. The objective is to improve the design through numerical simulation before fabricating a next-generation prototype sealing device. Future work is aimed at implementing acoustic seal design improvements to further reduce the leakage flow rate through the device and at reducing the device's overall size.

Daniels, Christopher C.↗

Effect of Post-HALT Annealing on Leakage Currents in Solid Tantalum Capacitors

Degradation of leakage currents is often observed during life testing of tantalum capacitors and is sometimes attributed to the field-induced crystallization in amorphous anodic tantalum pentoxide dielectrics. However, degradation of leakage currents and the possibility of annealing of degraded capacitors have not been investigated yet. In this work the effect of annealing after highly accelerated life testing (HALT) on leakage currents in various types of solid tantalum capacitors was analyzed. Variations of leakage currents with time during annealing at temperatures from 125 oC to 180 oC, thermally stimulated depolarization (TSD) currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. Annealing resulted in a gradual decrease of leakage currents and restored their initial values. Repeat HALT after annealing resulted in reproducible degradation of leakage currents. The observed results are explained based on ionic charge instability (drift/diffusion of oxygen vacancies) in the tantalum pentoxide dielectrics using a modified Schottky conduction mechanism.

Teverovsky, Alexander↗

Effects of Double-Leakage Tip Clearance Flow on the Performance of a Compressor Stage with a Large Rotor Tip Gap

Effects of a large rotor tip gap on the performance of a one and half stage axial compressor are investigated in detail with a numerical simulation based on LES and available PIV data. The current paper studies the main flow physics, including why and how the loss generation is increased with the large rotor tip gap. The present study reveals that when the tip gap becomes large, tip clearance fluid goes over the tip clearance core vortex and enters into the next blade's tip gap, which is called double-leakage tip clearance flow. As the tip clearance flow enters into the adjacent blade's tip gap, a vortex rope with a lower pressure core is generated. This vortex rope breaks up the tip clearance core vortex of the adjacent blade, resulting in a large additional mixing. This double-leakage tip clearance flow occurs at all operating conditions, from design flow to near stall condition, with the large tip gap for the current compressor stage. The double-leakage tip clearance flow, its interaction with the tip clearance core vortex of the adjacent blade, and the resulting large mixing loss are the main flow mechanism of the large rotor tip gap in the compressor. When the tip clearance is smaller, flow near the end wall follows more closely with the main passage flow and this double-leakage tip clearance flow does not happen near the design flow condition for the current compressor stage. When the compressor with a large tip gap operates at near stall operation, a strong vortex rope is generated near the leading edge due to the double-leakage flow. Part of this vortex separates from the path of the tip clearance core vortex and travels from the suction side of the blade toward the pressure side of the blade. This vortex is generated periodically at near stall operation with a large tip gap. As the vortex travels from the suction side to the pressure side of the blade, a large fluctuation of local pressure forces blade vibration. Nonsynchronous blade vibration occurs due to this vortex as the frequency of this vortex generation is not the same as the rotor. The present investigation confirms that this vortex is a part of separated tip clearance vortex, which is caused by the double-leakage tip clearance flow.

flow↗

Testing Rod Seal Leakage of a 700 HP Reciprocating Compressor

Methane emissions from reciprocating compressors in the U.S. natural gas industry account for over 72.4 Bcf per year according to a 2006 statement by the United States Environmental Protection Agency. Methane also has a global warming potential 50 times greater than carbon monoxide. Reciprocating compressors are the machinery type with the highest contribution to methane emissions at natural gas transmissions stations. The largest contributing factor comes from the sealing components in the packing components around the piston rod. SwRI, therefore, designed and setup a test loop to perform baseline packing leakage measurements on a four stage 700 HP JGT/4 compressor. The goal was to improve upon current packing leakage models and to compare new seals vs. used seals. The test loop design is described including the limits of operation. The Data Acquisition System (DAQ), including data measurements, is also fully described. The project shows the results of the commissioning process that verified the operation of all the components. Once the loop was commissioned, SwRI performed baseline packing leakage for multiple pressure ratios on each of the four stages of the compressor. The data was collected to develop an analytical model of the packing leakage. Finally, similar testing was performed after replacing the typical rod seal packing with used packing. The used packing leakage was compared to the baseline packing leakage.

03 NATURAL GAS↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of iteration strategies for a practical implementation of a higher order transverse leakage approximation

Transverse integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming in this approach is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In previous work, an improved, consistent quadratic leakage approximation was formulated, which derived from the class of higher order nodal methods developed some years ago. In this paper a number of iteration schemes are developed around this consistent quadratic leakage approximation which yield accurate node average results in much improved calculational times. The developed consistent leakage approximation is extended in this work via a number of numerical schemes, the most promising of which results from utilizing the consistent leakage approximation as a correction method to the standard quadratic leakage approximation. Numerical results are demonstrated on a set of benchmark problems, such as the 3D IAEA LWR and MOX C5 problems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reduced order models for prediction of groundwater quality impacts from CO₂ and brine leakage

A careful assessment of the risk associated with geologic CO₂ storage is critical to the deployment of large-scale storage projects. A potential risk is the deterioration of groundwater quality caused by the leakage of CO₂ and brine leakage from deep subsurface reservoirs. In probabilistic risk assessment studies, numerical modeling is the primary tool employed to assess risk. However, the application of traditional numerical models to fully evaluate the impact of CO₂ leakage on groundwater can be computationally complex, demanding large processing times and resources, and involving large uncertainties. As an alternative, reduced order models (ROMs) can be used as highly efficient surrogates for the complex process-based numerical models. In this study, we represent the complex hydrogeological and geochemical conditions in a heterogeneous aquifer and subsequent risk by developing and using two separate ROMs. The first ROM is derived from a model that accounts for the heterogeneous flow and transport conditions in the presence of complex leakage functions for CO₂ and brine. The second ROM is obtained from models that feature similar, but simplified flow and transport conditions, and allow for a more complex representation of all relevant geochemical reactions. To quantify possible impacts to groundwater aquifers, the basic risk metric is taken as the aquifer volume in which the water quality of the aquifer may be affected by an underlying CO₂ storage project. The integration of the two ROMs provides an estimate of the impacted aquifer volume taking into account uncertainties in flow, transport and chemical conditions. These two ROMs can be linked in a comprehensive system level model for quantitative risk assessment of the deep storage reservoir, wellbore leakage, and shallow aquifer impacts to assess the collective risk of CO₂ storage projects.

54 ENVIRONMENTAL SCIENCES↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Toward extreme high-temperature supercritical CO 2 power cycles: Leakage characterization of ceramic 3D-printed heat exchangers

We report future supercritical carbon dioxide (sCO 2 ) Brayton power cycles demand high-performance gas-to-gas heat exchangers (HXs) operating under extreme temperature and pressure conditions at which most existing superalloy materials fail to function safely. Ceramic HXs are deemed excellent candidates for advanced sCO 2 power plants as they can withstand high-temperature working environments. Particularly, ceramic 3D printing enables compact HX topologies employing complex and efficient heat transfer features. However, ceramic 3D-printed walls separating hot and cold flow streams are susceptible to a through-plane leakage inherent to a powder-based manufacturing process, including ceramic 3D printing. A potential leakage through ceramic separating walls poses a significant challenge in developing reliable ceramic 3D-printed HXs and could deteriorate thermal performance. In this study, various parameters, including feedstock slurry, 3D-printing direction, and post-processing conditions, are considered, for the first time, to characterize the argon gas leakage rate associated with alumina 3D-printed parts. Three 3D-printed ceramic structures of flat plates, curved tubes, and small-scale plate-and-frame HXs with various thicknesses are systematically studied to determine powder and ceramic 3D-printing conditions to eliminate the through-plane leakage. The results showed that an alumina 3D-printed plate with a thickness of 0.75 mm demonstrates a permeability of 6 x 10 -4 milli-darcy. An alumina 3D-printed tube with a wall thickness of 0.9 mm revealed a permeability of 9.6 x 10 -7 milli-darcy. Furthermore, leakage test results of functional 3D-printed modules showed a dependency on the 3D-printing direction. Particularly, alumina cell-scale HXs employing 1.5-mm-thick horizontal and vertical 3D-printed separating walls demonstrated impermeability and gas permeability of 7.2 x 10 -5 millidarcy, respectively. Insights gained from the present study facilitate the development of complex ceramic 3D-printed HXs and other balance of plant components for next-generation high-temperature high-pressure sCO 2 power cycles.

36 MATERIALS SCIENCE↗

An experimental and numerical study of wellbore leakage mitigation using pH-triggered polymer gelant

The potential leakage of hydrocarbon fluids or carbon dioxide from subsurface formations is a primary concern in wellbore integrity, oil and gas production, and CO 2 storage. Leaky wells with fractured cement or debonded microannuli are common sources of subsurface fluid leakage. The hydrocarbon fluid or CO 2 can migrate through such pathways to shallower formations and ultimately to surface. Cement fractures may have apertures on the order of microns, which are difficult to seal with typical workover techniques. A material that provides low viscosity during the injection but much higher viscosity after injection, with a minimum pressure gradient to yield flow at the target zone, is a potentially effective approach to seal the leakage pathways through cement fractures. pH-triggered polymers are such a material: aqueous solutions with low viscosity at low pH, containing pH-sensitive microgels which viscosify upon neutralization to become highly swollen gels with substantial yield stress that can block fluid flow. For the wellbore leakage application, the large alkalinity of wellbore cement provides the required neutralization. Our coreflood and rheological experiments show that pH-triggered polymer sealants such as polyacrylic acid polymer provide a robust seal if the process is properly designed; however, its long-term applicability depends on the dynamic geochemical environment of the wellbore. The process comprises three stages: (1) injection of a chelating agent as the preflush to ensure a favorable environment for the polymer gel, (2) injection of polymer solution, and (3) shut-in for the polymer gelation. A systematic study was done to understand the conditions under which the polymer gel remains stable and effectively seals the leakage pathways. A numerical model, based on polymer rheological properties and governing mechanisms observed in the laboratory experiments, was developed to simulate the reactive flow and transport of pH-triggered polymers in narrow fractures. Comparison with experiments shows a generally good agreement, despite the relative simplicity of the model. The numerical model was used to investigate further the underlying mechanisms of the process. The results can be used to design effectively the remediation process for a known fracture aperture size of the target zone.

42 ENGINEERING↗

Using temperature and flow fields to detect gas leakage from canisters containing spent nuclear fuel: Applications to RAMM-TM

The multi-physics STAR-CCM+ code has been used to simulate the temperature and flow fields in canister gas leakage experiments conducted by using a 1/4.5-scale model storage cask. The simulations were conducted at Argonne National Laboratory’s Laboratory Computing Resource Center, utilizing high-performance computing resources. Development of STAR-CCM+ simulation models for the 1/4.5-scale model cask is described herein, followed by validation of the simulation results against experimental data. Canister depressurization and thermal response during gas leakage are discussed, along with analyses of the leakage path and allowable leakage rate. The insights gained from the STAR-CCM+ simulations and leakage analyses will help guide future experiments and actual industry applications of Argonne’s Remote Area Modular Monitoring system for canister surface temperature measurement (RAMM-TM) to enable effective aging management of spent fuel during extended dry storage, as well as help reduce risks to public safety and health and protect the environment.

Canister gas leakage↗