Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Charged Track Reconstruction for GlueX at Jefferson Lab

The GlueX detector currently under construction at Jefferson Lab is a large acceptance device designed to facilitate the search for hybrid mesons. In order to accomplish this program, both photons and charged particles need to be reconstructed with high efficiency. Forward-going charged particles are detected in the Forward Drift Chambers while tracks exiting the target at angles greater than ?20 degrees are detected in the Central Drift Chamber. Hits in both sets of detectors are associated into track segments that are linked together to form track candidates. These candidates are fit using the Kalman Filter formalism. The track reconstruction sequence from track finding through track fitting will be described. Single-track efficiencies and resolutions will be presented. Results for simulated events containing multiple charged particles relevant for the GlueX physics program will also be presented.

Taylor, Simon↗

AI Applications to Physics Experiments at Jefferson Lab

We survey how AI/ML is being deployed across Jefferson Lab's experimental and accelerator programs. In EPSCI, Hydra applies computer vision to automate real-time data-quality monitoring across all four experimental halls, replacing manual inspection of hundreds to thousands of histograms per shift. AIEC (AI Experiment Controls) uses ML to stabilize drift chamber gains and is now part of standard CEBAF production running, while AI Optimized Polarization (AIOP) targets autonomous control of polarized targets and photon beam angular alignment. In CASA, cavity fault classification models identify faulted cavities and trip types from waveform data with ~85% and ~78% agreement to labeled data, respectively, and are deployed in production; a separate effort applies LLMs and hybrid search to make the CEBAF operations logbook AI-ready. QCD-focused work includes transformer- and GAN-based generative models for particle-level event simulation, with distributed GAN training scaling studies on Polaris. Additional efforts span ML-on-FPGA for the EIC and a new Data Science Department coordinating anomaly detection, uncertainty quantification, and HPC-scalable ML lab-wide. Collectively, these projects illustrate AI's growing role in improving efficiency across JLab's nuclear physics mission.

Mei, Xinxin [Thomas Jefferson National Accelerator↗

Overview of the Jefferson Lab 12 GeV Experimental Program in Halls A,B, and C

The 11 GeV beam energy available in experimental Halls A, B, and C as part of the Jefferson Lab 12 GeV Upgrade, combined with the new equipment in those halls will provide a rich and diverse physics program. This program includes inclusive measurements used to constrain polarized and unpolarized quark distributions in nucleons, exclusive reactions to access nucleon and meson form factors and GPDs, semi-inclusive measurements aimed at constraining TMDs, as well as measurements from nuclei to provide further insight into the origins of Short Range Correlations and the EMC Effect. The experimental equipment was designed with the above program in mind and the three halls provide complementary capabilities. Magnetic focusing spectrometers in Hall C (the new SHMS and existing HMS) will provide precision separated and unseparated cross section measurements and ratios. The new large acceptance CLAS12 spectrometer in Hall B enables measurements over broad regions of phase space. In Hall A, the new SBS spectrometer, used in conjunction with the existing HRS or Big Bite spectrometers will provide access to very large Q2 and allow for measurements requiring both high luminosity and large acceptance. This talk will give an overview of the upcoming experimental program in Halls A,B, and C, in particular highlighting synergies between the hall programs, which will allow Jefferson Lab to maximize the science output its 12 GeV program.

Gaskell, David↗

Resonance Electroexcitations at High Momentum Transfers with Jefferson Lab at 22 GeV

Studies of nucleon resonance electroexcitation amplitudes are providing insight into many facets of strong QCD dynamics. These amplitudes have become available from the analyses of exclusive electroproduction experiments at Jefferson Lab with CLAS in the range of momentum transfers up to 5 GeV and are currently extended to momentum transfers up to 10 GeV by measurements with CLAS12. A 22-GeV upgrade of CEBAF at Jefferson Lab will offer unique opportunities to explore momentum transfers up to 30 GeV corresponding to the full range of distances where nucleon resonance states are generated in strong QCD. These studies can shed light on the emergence of the dominant part of hadron mass.

Achenbach, Patrick [Thomas Jefferson National Acce↗

Boosting Deuteron Polarization in HD Targets: Experience of moving spins between H and D with RF methods during the E06-101 experiment at Jefferson Lab

Solid HDice targets are polarized by bringing the HD crystal to thermal equilibrium at low temperature and high magnetic field, typically 10-20 mK and 15 Tesla, at Jefferson Lab. In this regime, due to its smaller magnetic moment, the resulting polarization for D is always at least three times smaller than for H. The controlled amount of polarizing catalysts, o-H2 and p-D2, used in the process of reaching a frozen-spin state, further limit the maximum achievable D polarization. Nonetheless, H and D polarizations can be transferred from one to the other by connecting the H and D sub-states of the HD system with RF. In a large target, the RF power needed for such transitions is effectively limited by non-uniformities in the RF field. High efficiency transfers can require substantial RF power levels, and a tuned-RF circuit is needed to prevent large temperature excursions of the holding cryostat. In this paper, we compare the advantages and limitations of two different RF transfer methods to increase D polarization, Forbidden Adiabatic and Saturated Forbidden RF Transitions. The experience with the HD targets used during the recently completed E06-101 experiment in Hall-B of Jefferson Lab is discussed.

Wei, Xiangdong↗

A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Measurement of the Ar ( e , e ' p ) and Ti ( e , e ' p ) cross sections in Jefferson Lab Hall A

The E12-14-012 experiment, performed in Jefferson Lab Hall A, has collected exclusive electron-scattering data ( e , e ' p ) in parallel kinematics using natural argon and natural titanium targets. In this study we report the first results of the analysis of the data set corresponding to beam energy 2222 GeV, electron scattering angle 21 . 5 ° , and proton emission angle – 50 ° . The differential cross sections, measured with ≈ 4 % uncertainty, have been studied as a function of missing energy and missing momentum, and compared to the results of Monte Carlo simulations, obtained from a model based on the distorted-wave impulse approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

CEBAF at Jefferson Lab

The U.S. and international nuclear physics community uses Jefferson Lab's state-of-the-art Continuous Electron Beam Accelerator Facility or CEBAF to conduct world-class fundamental research. The Lab supports more than 1,250 visiting researchers from more than 200 institutions.

Source record↗

A Solid Polarized Target Development Facility at Jefferson Lab

Solid polarized targets are a crucial tool used in scattering experiments to investigate different properties of the nucleon. The equipment used to produce, measure, and maintain conditions for the polarized material is complex in comparison to nonpolarized targets. This, in combination with the frequency of polarized experiments run at Jefferson Lab, limits the opportunity to refine and build upon experience gained from previously constructed targets. To address this, the Jefferson Lab Target Group has begun the construction of a permanent facility dedicated to creating and testing material for Dynamic Nuclear Polarization. The design elements and manufacture of the test cryostat along with the incorporation of other DNP associated equipment will be presented.

Brock, James [Thomas Jefferson National Accelerato↗

Nucleon Spin - Results from Jefferson Lab

Over thirty years after the first experiments probed the spin structure of the nucleon, the pace of experimental and theoretical exploration of this subject keeps increasing. During its fifteen-year run with beam energies up to 6 GeV, Jefferson Lab has made many important contributions to this field - from measurements of the inclusive spin structure functions of the proton and the neutron over a wide kinematic range to seminal experiments accessing the three-dimensional nucleon spin structure through Generalized Parton Distributions and Transverse Momentum Dependent structure functions. An even brighter future lies ahead - after the 12 GeV upgrade, Jefferson Lab will completely map the spin-dependent parton distribution functions for all quark flavors in the valence region. In this talk, I will present an overview of this program, with special emphasis on recent and forthcoming results from the 6 GeV run and a glimpse of the future program with 12 GeV.

Kuhn, Sebastian↗

Design and commissioning of an e-beam irradiation beamline at the Upgraded Injector Test Facility at Jefferson Lab

We report the Upgraded Injector Test Facility (UITF) at Jefferson Lab is a continuous-wave superconducting linear accelerator capable of providing an electron beam with energy up to 10 MeV. A beamline for electron-beam irradiation has been designed, installed and successfully commissioned at this facility, aimed at the degradation study of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) in wastewater treatment. A solenoid with a peak axial magnetic field of up to 0.28 T and a set of raster coils were used to obtain a Gaussian beam profile with a transverse standard deviation of ~ 15.0 mm at the target location. Monte-Carlo simulations using FLUKA were carried out to calculate the total absorbed dose and the dose distribution in the sample volume inside the target cell. The simulations were benchmarked experimentally by dosimetry mapping using optichromic dosimeters. The results of the irradiation experiments showed a ~ 95% reduction of 1,4-dioxane in ultra-pure water for a dose of 1 kGy, demonstrating the potential of electron-beam irradiation towards addressing growing challenges in environmental remediation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A

The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0 p -shell region of nuclei such as the hypernuclei produced in electroproduction on 9 Be, 12 C and 16 O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. Here, measurable strength with sub-MeV energy resolution was recorded for the core-excited states of $^{12}_{Λ}$B. A high-quality$^{16}_{Λ}N hypernuclear spectrum was likewise obtained. A first measurement of the Λ binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 ± 0.16 MeV. Similarly, the first$^{9}_{Λ}Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Λ separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been observed that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the γ-ray spectroscopy technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance characteristics of Jefferson Lab's new SRF infrastructure

In the past two years, Jefferson Lab has reconfigured and renovated its SRF support infrastructure as part of the Technology and Engineering Development Facility project, TEDF. The most significant changes are in the cleanroom and chemistry facilities. We report the initial characterization data on the new ultra-pure water systems, cleanroom facilities, describe the reconfiguration of existing facilities and also opportunities for flexible growth presented by the new arrangement.

Reece, Charles E.↗

Nucleon Tomography Studies at Jefferson Lab

Protons and neutrons, are the building blocks of atomic nuclei. They constitute over 99 percent of the mass of the matter in the visible universe. A fundamental challenge of modern nuclear physics is to understand the structure of these constituents. The 12 GeV Upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab and the construction of state-of-the-art detector systems make it a unique facility in the world to address this challenge. Electron scattering is a superb experimental tool to study the internal structure of nucleons at differing distance scales, as the resolving power of the probe can be varied. The CEBAF Upgrade was completed in September 2017 and the new generation of experiments has started. These experiments will enable a collaboration of scientists from around the world to perform precise experiments of exclusive processes covering a large range in kinematics to effectively engage in nuclear imaging, revealing hidden aspects of its internal structure, and providing insight into quark confinement forces in the nucleon, one of the greatest mysteries of modern physics. The Generalized Parton Distributions (GPDs) provide the theoretical framework to interpret the experimental data in terms of 3-dimensional imaging. In addition, recent development demonstrated that the GPD formalism enables access to the nucleon's Gravitational Form Factors that encode its mechanical properties. We will focus on the study of the Deeply Virtual Compton Scattering (DVCS), the most effective way to access GPDs. We will review the landscape of both theory and experiment, and discuss the latest results from Jefferson Lab at 6 GeV in comparison with results from other facilities, and present a first look at the new experiments with the 12 GeV Upgrade.

Elouadrhiri, Latifa↗

Final Results from the Jefferson Lab Qweak Experiment and Constraints on Physics Beyond the Standard Model

The $Q_{weak}$ $\vec{e}p$ elastic scattering experiment used to extract an asymmetry at $Q^2$ = 0.0248 $GeV^2$ will be described. The final result was -226.5 ± 9.3 ppb- the most precise ep asymmetry ever measured. Some of the backgrounds and corrections applied in the experiment will be explained and quantified, and some of the experimental challenges will be described. Several methods used to extract consistent values of the proton's weak charge $Q^p_w$ from our asymmetry measurement will be outlined. We also show the multi-TeV mass reach for beyond-the-Standard-Model physics obtained from our determination of the proton's weak charge, and discuss our sensitivity to specific examples of new physics like compositeness. From the proton's weak charge, a result for the fundamental standard model parameter $sin^2θ_W$ is obtained at the energy scale of our experiment. We compare that to the few other determinations of $sin^2θ_W$ available in the literature, as well as the predicted behaviour based on SM input.

Smith, Gregory↗

Detailed study of Short Range Correlations at Jefferson Lab

The force which holds the nucleus together has been under intense study for many decades. The nuclear shell model, which plays a central role in these investigations, has been very successful in reproducing low energy measurements, but is insufficient to predict medium energy results. The discrepancy is believed to originate from short range correlations, i.e. overlapping nucleons in the nucleus which briefly create densities close to those in neutron stars. Using an electron beam, these features of the nucleus can be isolated and studied at kinematics where xbj>1. In order to present the new results from Jefferson Lab, we will first highlight what has happened in the field over the last decade. We will also discuss the goals of the future related measurements scheduled to run at Jefferson Lab after the 12 GeV upgrade.

Solvignon, Patricia↗