Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion Exchange Capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hanford Tank Waste Matrix Impact on Ion Exchange Performance Using Crystalline Silicotitanate

The removal of radiocesium from Hanford tank waste supernate is a critical step in preparing feed for low-activity waste immobilization. This study evaluated cesium ion exchange performance using crystalline silicotitanate (CST) media in a series of tests designed to evaluate the influence of waste matrix variability on capacity and kinetics. Tank waste supernate subsampled from five Hanford double-shell tanks encompassed a range of sodium, hydroxide, nitrate, and nitrite concentrations in order to assess the impact of feed variability on the performance of the ion exchange system. Both equilibrium and dynamic ion exchange tests were conducted to quantify cesium distribution coefficients and breakthrough behavior under prototypic operating conditions. Results indicated that effective cesium capacity varied by up to a factor of five across the matrices tested, with higher sodium concentrations significantly reducing uptake. Kinetic behavior was similarly matrix-dependent, with solution viscosity contributing to a twofold variation in mass-transfer rates. These results demonstrate the strong dependence of CST ion exchange performance on waste composition and must be incorporated into predictive models for future treatment system design and optimization.

Westesen, Amy M.↗

Properties of a Novel Ion-Exchange Film

A new ion-exchange material (based on polyacrylic acid) and some of its analytical applications have been reported. This paper contains data on the ion-exchange properties of the film form of the material and its potential application to the decontamination of waste water and drinking water. The film has a high exchange capacity of 5 to 6 meq/g and a pK(sub a) of 5.7. The calcium form is the most effective for removing metal ions from solution, and the optimum pH range is between 5 and 7. The exchange rates are slower for the film than for bead and powder forms of the ion-exchange material; otherwise, the properties are similar. The film is effective when hard water solutions are employed and also when metal ions are in the complex matrix of waste water from electroplating. The film can be used in flow systems having a flow channel large enough to allow passage of turbid solutions.

Street, Kenneth W.↗

Properties of a Novel Ion-Exchange Film

A new ion-exchange material (based on polyacrylic acid) and some of its analytical applications have been reported. This paper contains data on the ion-exchange properties of the film form of the material and its potential application to the decontamination of waste water and drinking water. The film has a high exchange capacity of 5 to 6 meq/g and a pK(sub a) of 5.7. The calcium form is the most effective for removing metal ions from solution, and the optimum pH range is between 5 and 7. The exchange rates are slower for the film than for bead and powder forms of the ion-exchange material; otherwise, the properties are similar. The film is effective when hard water solutions are employed and also when metal ions are in the complex matrix of waste water from electroplating. The film can be used in flow systems having a flow channel large enough to allow passage of turbid solutions.

Street, Kenneth W.↗

Mechanism of Lithium Ion Exchange Into Spinel Manganese Oxide

Lithium manganese oxide (LMO) is an effective absorbent for lithium recovery from brines, characterized by its high adsorption capacity, excellent regeneration performance, and selectivity. Here, this study investigates the mechanisms of material degradation during lithium loading and unloading in LMO, employing a combination of time‐resolved Raman spectroscopy, X‐ray diffraction, and X‐ray photoelectron spectroscopy. Key findings reveal that the A 1g vibrational mode wavenumber shifts from 635 cm −1 at the onset of lithium ion exchange to 656 cm −1 after 12 min, indicating local symmetry loss and manganese (Mn) loss during lithium intercalation. The proposed lithium exchange mechanism involves initial occupation of tetrahedral interstitial voids, followed by migration into interstitial sites between Mn octahedral sites. Computational modeling suggests that the loss of symmetry in MnO cubane‐like groups occurs as lithium migrates, significantly affecting the Raman spectra. Importantly, the study demonstrates that after 100 cycles of lithium/hydrogen loading, a 24% loss in Mn is observed, which correlates with decreased structural stability; however, the structural integrity of LMO is enhanced when subjected to multiple cycles without complete loading. Here, these insights contribute to the understanding of LMO's performance in lithium recovery applications and highlight potential strategies to optimize its use in future technologies.

15 GEOTHERMAL ENERGY↗

Boosting the Low-Temperature Performance of Graphite Anodes by Creating an Electrochemically Active Interface

Graphite is the major anode material used in commercial lithium-ion batteries (LIBs). However, the sluggish ion-transfer kinetics associated with graphite anodes significantly restrict the operation of LIBs over a wide temperature. This is primarily due to their low reversible capacity and the substantial overpotential exhibited under low-temperature conditions. To address this limitation, we demonstrate herein an approach that involves grafting an electrochemically active lithium benzenesulfonate layer onto a graphite surface through a typical reduction reaction of diazonium cations, followed by ion exchange process. This surface modification reduces the charge transfer resistance of graphite anodes, leading to an excellent reversible capacity of ~150 mAh g –1 at low-temperatures (-20 °C, 0.1C). Electrochemical impedance spectroscopy indicates that both desolvation of the lithium ions outside the graphite, and lithium diffusion within the solid electrolyte interphase and graphite lattice are two crucial rate-limiting steps during the Li (de)lithiation, with the latter dominating during the low-temperature operation. In conclusion, these findings demonstrate a facile method for enhancing the low-temperature performance of graphite through surface modification and provide valuable insights into fundamental understandings that can guide the future design of better -low-temperature graphite anodes.

25 ENERGY STORAGE↗

Exploring Phosphonium‐Based Anion Exchange Polymers for Moisture Swing Direct Air Capture of Carbon Dioxide

This study explores the performance and stability of ammonium and phosphonium-based polymeric ionic liquids (PILs) with methyl and butyl substituents in moisture-swing direct air capture of CO 2 . The polymers are synthesized with chloride counterions, followed by ion exchange to the bicarbonate ion, and tests for CO 2 capture capacity and stability under cyclic wet–dry conditions. The phosphonium polymer with methyl substituents [PVBT-MeP] demonstrates the highest CO 2 capture capacity at ≈510 µmol g⁻¹, attributed to minimal steric hindrance and stronger ion pairing with bicarbonate. However, oxidative degradation is detected by 31 P NMR spectroscopy after the moisture swing experiment, with the appearance of a phosphine oxide peak at 61.28 ppm, which indicates phosphorus oxidation as the primary degradation pathway. In contrast, the ammonium polymer with butyl substituents [PVBT-BuN] exhibits the highest stability, showing no degradation over five moisture swing cycles. Additional stability experiments in 0.5 m KHCO 3 solutions reveal no degradation for any PIL, suggesting that oxidative degradation is driven by dynamic acid-base reactions during the moisture swing cycles in the air. Furthermore, these findings reveal the potential of phosphonium-based PILs for moisture-swing direct air capture, achieving high capacity while highlighting the need for optimized stability through counterion and structural design.

36 MATERIALS SCIENCE↗

Treatment bed microbiological control

The effects of microbial fouling on treatment bed (TB) performance are being studied. Fouling of activated carbon (AC) and ion exchange resins (IEX) by live and devitalized bacteria can cause decreased capacity for selected sorbates with AC and IEX TB. More data are needed on organic species removal in the trace region of solute sorption isotherms. TB colonization was prevented by nonclassical chemical disinfectant compositions (quaternary ammonium resins) applied in suitable configurations. Recently, the protection of carbon beds via direct disinfectant impregnation has shown promise. Effects (of impregnation) upon bed sorption/removal characteristics are to be studied with representative contaminants. The potential need to remove solutes added or produced during water disinfection and/or TB microbiological control must be investigated.

Janauer, Gilbert E.↗

Zeolitic Imidazole Framework Decorated Substrates for Lead Removal From Water

Lead contamination in water supplies necessitates efficient and mechanistically understood removal strategies. Zeolitic imidazole frameworks (ZIFs) are promising adsorbents; however, ZIF-67 (Co-based) is more susceptible to hydrolysis than its zinc analogue ZIF-8, raising questions about stability during metal uptake. In this study, we systematically compare ZIF-8 and ZIF-67 under controlled pH conditions and evaluate how substrate anchoring influences hydrolytic stability and Pb 2+ adsorption behavior. By integrating adsorption capacity measurements, kinetic analysis, metal-node leaching data, and structural characterization, we distinguish ion exchange from framework degradation and clarify the temporal interplay between adsorption and hydrolysis. Although ZIF-67 exhibits greater hydrolytic sensitivity, coordination with phosphoryl-bearing Mucor hiemalis membranes significantly reduces Co 2+ leaching and enhances structural retention. Under the optimized conditions (pH 5), ZIF-67@Mucor achieves a maximum Pb 2+ adsorption capacity of 867 mg g −1 . These findings demonstrate that substrate-dependent stabilization enables controlled exploitation of ZIF reactivity for aqueous metal remediation.

Adsorption↗

Copper-Exchanged Zeolite L Traps Oxygen

Brief series of simple chemical treatments found to enhance ability of zeolite to remove oxygen from mixture of gases. Thermally stable up to 700 degrees C and has high specific surface area which provides high capacity for adsorption of gases. To increase ability to adsorb oxygen selectively, copper added by ion exchange, and copper-exchanged zeolite reduced with hydrogen. As result, copper dispersed atomically on inner surfaces of zeolite, making it highly reactive to oxygen, even at room temperature. Reactivity to oxygen even greater at higher temperatures.

Sharma, Pramod K.↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly

The urine processor assembly (UPA) on the International Space Station (ISS) recovers water from urine via a vacuum distillation process. The distillation occurs in a rotating distillation assembly (DA) where the urine is heated and subjected to sub-ambient pressure. As water is removed, the original organics, salts, and minerals in the urine become more concentrated and result in urine brine. Eventually, water removal will concentrate the urine brine to super saturation of individual constituents, and precipitation occurs. Under typical UPA DA operating conditions, calcium sulfate or gypsum is the first chemical to precipitate in substantial quantity. During preflight testing with ground urine, the UPA achieved 85% water recovery without precipitation. However, on ISS, it is possible that crewmember urine can be significantly more concentrated relative to urine from ground donors. As a result, gypsum precipitated in the DA when operating at water recovery rates at or near 85%, causing the failure and subsequent re14 NASA Tech Briefs, September 2013 placement of the DA. Later investigations have demonstrated that an excess of calcium and sulfate will cause precipitation at water recovery rates greater than 70%. The source of the excess calcium is likely physiological in nature, via crewmembers' bone loss, while the excess sulfate is primarily due to the sulfuric acid component of the urine pretreatment. To prevent gypsum precipitation in the UPA, the Precipitation Prevention Project (PPP) team has focused on removing the calcium ion from pretreated urine, using ion exchange resins as calcium removal agents. The selectivity and effectiveness of ion exchange resins are determined by such factors as the mobility of the liquid phase through the polymer matrix, the density of functional groups, type of functional groups bound to the matrix, and the chemical characteristics of the liquid phase (pH, oxidation potential, and ionic strength). Previous experience with ion exchange resins has demonstrated that the most effective implementation for an ion exchange resin is a cartridge, or column, in which the resin is contained. Based on the results of equilibrium and sub-scale dynamic column testing, a possible solution for mitigating the calcium precipitation issue on the ISS has been identified. From an original pool of 13 ion exchange resins, two candidates have been identified that demonstrate substantial calcium removal on the sub-scale. The dramatic reduction in resin performance from published calcium uptake demonstrates the need for thorough evaluation of resins at the low pH and strong oxidizing environment present in the UPA. Chemical variations in the influent (calcium concentrations and pretreatment dosing) appear to have a noticeable impact on the calcium capacity of the resin. Low calcium concentrations and high pretreatment dosing will likely result in a decrease in calcium capacity. Conversely, low pre trea t - ment dosing will likely result in an increase in calcium capacity. In contrast, investigations at a variety of flow rates, length-to-diameter ratios, resin volumes, and flow regimes (continuous versus pulsed) show that changes in physical parameters do not have substantial impacts on resin performance in the very low specific velocity ranges of interest. This result is particularly useful because most commercial applications at higher specific velocities do show a relatively strong relationship between flow and capacity. The lack of a strong relationship will allow more flexibility in the implementation of an ion exchange bed for flight. Verification of subscale tests with flight-scale resin beds is recommended prior to implementation in the on-orbit UPA.

Mitchell, Julie↗

Lead Removal From Synthetic Leachate Matrices by a Novel Ion-Exchange Material

This report discusses the application of a novel polyacrylate-based ion-exchange material (IEM) for the removal of lead (Pb) ions from water. Preliminary testing includes the establishment of the operating pH range, capacity information, and the effect of calcium and anions in the matrix. Batch testing with powder indicates slightly different optimal operational conditions from those used for column testing. The ion exchanger is excellent for removing lead from aqueous solutions.

Street, Kenneth W., Jr.↗

Rational Construction of Porous Metal–Organic Frameworks for Uranium(VI) Extraction: The Strong Periodic Tendency with a Metal Node

Although metal-organic frameworks (MOFs) have been reported as important porous materials for the potential utility in metal ion separation, coordinating the functionality, structure, and component of MOFs remains a great challenge. Herein, a series of anionic rare earth MOFs (RE-MOFs) were synthesized via a solvothermal template reaction and for the first time explored for uranium(VI) capture from an acidic medium. The unusually high extraction capacity of UO2 2 + (e.g., 538 mg U per g of Y-MOF) was achieved through ion-exchange with the concomitant release of Me 2 NH 2 + , during which the uranium(VI) extraction in the series of isostructural RE-MOFs was found to be highly sensitive to the ionic radii of the metal nodes. That is, the uranium(VI) adsorption capacities continuously increased as the ionic radii decreased. Finally, in-depth mechanism insight was obtained from molecular dynamics simulations, suggesting that both the accessible pore volume of the MOFs and hydrogen-bonding interactions contribute to the strong periodic tendency of uranium(VI) extraction.

36 MATERIALS SCIENCE↗

Unlocking High Capacity and Fast Na + Diffusion of H x CrS 2 by Proton-Exchange Pretreatment

This study presents a new material, “H x CrS 2 " (denotes approximate composition) formed by proton-exchange of NaCrS 2 which has a measured capacity of 728 mAh g -1 with significant improvements to capacity retention, sustaining over 700 mAh g -1 during cycling experiments. This is the highest reported capacity for a transition metal sulfide electrode and outperforms the most promising proposed sodium anodes to date. H x CrS 2 exhibits a biphasic structure featuring alternating crystalline and amorphous lamella on the scale of a few nanometers. This unique structural motif enables reversible access to Cr redox in the material resulting in higher capacities than seen in the parent structure which features only S redox. In conclusion, pretreatment by proton-exchange offers a route to materials such as H x CrS 2 which provide fast diffusion and high capacities for sodium-ion batteries.

25 ENERGY STORAGE↗

Ion Exchange Processes for CO 2 Mineralization Using Industrial Waste Streams: Pilot Plant Demonstration and Life Cycle Assessment

Abstract An attractive technique for removing CO 2 from the environment is sequestration within stable carbonate solids (e. g., calcite). However, continuous addition of alkalinity is required to achieve favorable conditions for carbonate precipitation (pH>8) from aqueous streams containing dissolved CO 2 (pH<4.5) and Ca 2+ ions. In this study, a pH‐swing process using ion exchange was demonstrated to process 300 L of produced water brine per day for CO 2 mineralization. Proton titration capacities were quantified for aqueous streams in equilibrium with gas streams at various concentrations of CO 2 (pCO 2 =0.03–0.20 atm) and at various flow rates (0.5–2.0 L min −1 ). Energy intensities for the process were determined to be between 30 and 65 kWh per tonne of CO 2 sequestered depending on the composition of the brine stream. A life cycle assessment was performed to analyze the net carbon emissions of the technology which indicated a net CO 2 reduction for pCO 2 ≥0.12 atm (−0.06–−0.39 kg CO 2 e per kg precipitated CaCO 3 ) utilizing calcium‐rich brines. The results from this study indicate the ion exchange process can be used as a scalable method to provide alkalinity necessary for the capture and storage of CO 2 in Ca‐rich waste streams.

Chemistry↗

Ultra-low concentration terbium (Tb) adsorption on garlic peels biosorbent and its application for $\mathrm{Nd}$-$\mathrm{Fe}$-$\mathrm{B}$ scraps recovery

Motivated by the strategic value of middle-heavy rare earth elements (MHREEs), we proposed a bio-adsorption method to recover ultra-low concentration terbium (Tb(Ⅲ)) from industrial wastewater that originated from the Nd-Fe-B scraps recovery process. It could be found that Tb(Ⅲ) ions as low as 5.34 ng·mL -1 (ppb) could be adsorbed onto Ca(Ⅱ)-modified garlic peels (Ca-GP) within 10 min with the adsorption efficiency of 99.2% at pH 3.5. The adsorption behavior of Tb(Ⅲ) onto Ca-GP conformed the Langmuir isotherm model and pseudo-second-order kinetic model. Attenuated total reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS) and density-functional theory (DFT) calculations results showed that Tb(Ⅲ) ions could be ion-exchanged with cations in Ca-GP such as Ca(Ⅱ) and -COOH. In application, column experiment results showed that the maximum bed adsorption capacity for Tb, praseodymium (Pr), neodymium (Nd), dysprosium (Dy), and Total rare earth elements (REEs) ions calculated by the Thomas model was 0.06, 3.50, 9.65, 7.34, and 27.37 µg·g -1 , respectively, with the initial concentration of 0.37 ng·mL -1 Tb, 20 ng·mL -1 Pr, 44 ng·mL -1 Nd, 67 ng·mL -1 Dy and 170 ng·mL -1 total REEs ions of actual solutions (below the solubility of rare-earth hydroxide). Here this manuscript thus provided a novel cost-effective and efficient approach to the enrichment and recovery of MHREEs from ultra-low concentration REEs ions-containing solutions.

54 ENVIRONMENTAL SCIENCES↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Measurement of Crossover and Interfacial Resistance of Ion-Exchange Membranes in All-Vanadium Redox Flow Batteries

Among various components commonly used in redox flow batteries (RFBs), the separator plays a significant role, influencing resistance to current as well as capacity decay via unintended crossover. It is well-established that the ohmic overpotential is dominated by the membrane and interfacial resistance in most aqueous RFBs. The ultimate goal of engineering membranes is to improve the ionic conductivity while keeping crossover at a minimum. One of the major issues yet to be addressed is the contribution of interfacial phenomena in the influence of ionic and water transport through the membrane. In this work, we have utilized a novel experimental system capable of measuring the ionic crossover in real-time to quantify the permeability of ionic species. Specifically, we have focused on quantifying the contributions from the interfacial resistance to ionic crossover. The trade-off between the mass and ionic transport impedance caused by the interface of the membranes has been addressed. The MacMullin number has been quantified for a series of electrolyte configurations and a correlation between the ionic conductivity of the contacting electrolyte and the Nafion® membrane has been established. The performance of individual ion-exchange membranes along with a stack of various separators have been explored. We have found that utilizing a stack of membranes is significantly beneficial in reducing the electroactive species crossover in redox flow batteries compared to a single membrane of the same fold thickness. For example, we have demonstrated that the utilization of five layers of Nafion ® 211 membrane reduces the crossover by 37% while only increasing the area-specific resistance (ASR) by 15% compared to a single layer Nafion ® 115 membrane. Therefore, the influence of interfacial impedance in reducing the vanadium ion crossover is substantially higher compared to a corresponding increase in ASR, indicating that mass and ohmic interfacial resistances are dissimilar. We have expanded our analysis to a combination of commercially available ion-exchange membranes and provided a design chart for membrane selection based on the application of interest (short duration/high-performance vs. long-term durability). The results of this study provide a deeper insight into the optimization of all-vanadium redox flow batteries (VRFBs).

UV/Vis spectroscopy↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs- 137. The TCCR project is currently focused on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently prepared CST media batches (9120-B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗