Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Iodide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.

Apollo 17 mission Report. Supplement 6: Calibration results for gamma ray spectrometer sodium iodide crystal

A major difficulty in medium energy gamma-ray remote sensing spectroscopy and astronomy measurements was the high rate of unwanted background resulting from the following major sources: (1) prompt secondary gamma-rays produced by cosmic-ray interactions in satellite materials; (2) direct charged-particle counts; (3) radioactivity induced in the detector materials by cosmic-ray and trapped protons; (4) radioactivity induced in detector materials by the planetary (e.g., earth or moon) albedo neutron flux; (5) radioactivity induced in the detector materials by the interaction of secondary neutrons produced throughout the spacecraft by cosmic-ray and trapped proton interactions; (6) radioactivity induced in spacecraft materials by the mechanisms outlined in 3, 4, and 5; and (7) natural radioactivity in spacecraft and detector materials. The purpose of this experiment was to obtain information on effects 3, 4, and 5, and from this information start developing calculational methods for predicting the background induced in the crystal detector in order to correct the Apollo gamma-ray spectrometer data for this interference.

Dyer, C.

Radioactivity observed in the sodium iodide gamma-ray spectrometer returned on the Apollo 17 mission

In order to obtain information on radioactive background induced in the Apollo 15 and 16 gamma-ray spectrometers (7 cm x 7 cm NaI) by particle irradiation during spaceflight, and identical detector was flown and returned to earth on the Apollo 17 mission. The induced radioactivity was monitored both internally and externally from one and a half hours after splashdown. When used in conjunction with a computation scheme for estimating induced activation from calculated trapped proton and cosmic-ray fluences, these results show an important contribution resulting from both thermal and energetic neutrons produced in the heavy spacecraft by cosmic-ray interactions.

Dyer, C. S.

The specific light output of cesium iodide crystals

Large area ion chambers for a high energy cosmic ray experiment, scintillating plastic fibers as light pipes for a cosmic ray hodoscope, and an evaluation of clad scintillating light pipes were considered.

Gregory, J. C.

Performance of photomultiplier tubes and sodium iodide scintillation detector systems

The performance of photomultiplier tubes (PMT's) and scintillation detector systems incorporating 50.8 by 1.27 cm NaI (T l) crystals was investigated to determine the characteristics of the photomultiplier tubes and optimize the detector geometry for the Burst and Transient Source Experiment on the Gamma Ray Observatory. Background information on performance characteristics of PMT's and NaI (T l) detectors is provided, procedures for measurement of relevant parameters are specified, and results of these measurements are presented.

Meegan, C. A.

A High Resolution Spectroscopic Study of the Nu2 Band of Hydrogen Sulfide and the 1-0 Band of Hydrogen Iodide

A tunable diode laser spectrometer was constructed and used to study: (1) the effects of centrifugal distortion on the transition frequencies and strengths of the nu sub 2 band of H2S, and (2) nuclear quadrupole hyperfine structure in the 1-0 band of HI. A total of 126 line frequencies and 94 line strengths in the nu sub 2 band of H2S were measured. The average accuracy of the line frequency measurements was + or - 0.0016 cm. The line strengths were measured to an average accuracy of about 3 percent. The effect of the finite spectral width of the diode laser on the measurement of line strengths is discussed. The observed H2S line frequencies were fit to Watson's AS and NS reduced Hamiltonian in both the Ir and IIIr coordinate representations in order to determine the best set of rotation distortion constants for the upper state of the nu sub 2 band. Comparisons of the observed line strengths in this band to rigid rotor line strengths are also presented. Nuclear quadrupole hyperfine structure in the low J lines of the 1-0 band of HI was observed. The upper vibrational state nuclear quadrupole coupling constant, determined from the observed splittings, was -1850 MHz + or - 12 MHz or 1.2 percent + or - 0.7 percent larger than the ground state coupling constant.

Strow, L. L.

Position measurements for heavy ion beams using a sodium iodide scintillator

A 50 cm diameter, 1.7 cm thick disc of NaI scintillator has been mounted to permit edge viewing by four photomultipliers. Energetic heavy ions passing through the scintillator at different positions cause a variation in the division of light among the photomultipliers. A performance close to the expected limit for 670 MeV/n neon has been achieved. Calculations of expected response using an optical model agree well with the measurements.

Buffington, A.

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.

Atmospheric methyl iodide /CH3I/

It is found that atmospheric concentrations of CH3I are not greater than about 3 pptv over most of the earth's surface and drop to less than half this value above the boundary layer, suggesting that the compound is not likely to play such important roles, on a global scale, as the destruction of tropospheric O3 and free radicals and the increasing of the NO2/NO ratio and hydroxyl radical densities. It is hypothesized that a large portion of the global CH3I comes from oceanic regions of high biomass productivity, where the compound may play a key role in local atmospheric chemistry. Attention is given to CH3I measurement uncertainties with regard to global distribution, sources, and sinks.

Rasmussen, R. A.

Room-temperature mercuric iodide spectrometry for low-energy X-rays

A discussion of the limits of energy resolution in different energy ranges is given. The energy resolution of a spectrometer is analyzed in terms of the parameters characterizing the crystal, the detector, and the amplification electronics. A high-resolution room-temperature HgI2 spectrometry system was used to measure low-energy X-ray fluorescence spectra. For the MgK-alpha X-ray line the measured resolution was 245 eV (fwhm); the electronic noise linewidth of the system was 225 eV. Alpha-particles were used to excite X-ray fluorescence from low-Z elements separately or in combination. The shape of the photopeaks in the spectra is discussed.

Kusmiss, J. H.

Advances in the development of encapsulants for mercuric iodide X-ray detectors

Advances in the development of protective impermeable encapsulants with high transparency to ultra-low-energy X-rays for use on HgI2 X-ray detectors are reported. Various X-ray fluorescence spectra from coated detectors are presented. The X-ray absorption in the encapsulants has been analyzed using characteristic radiation from various elements. Results suggest that low-energy cutoffs for the detectors are not determined solely by the encapsulating coatings presently employed but are also influenced by the front electrode and surface effects, which can affect the local electric field or the surface recombination velocity. An energy resolution of 182 eV (FWHM) has been achieved for Ni L lines at 850 eV. Improved detector sensitivity to X-ray energies under 700 eV is demonstrated.

Iwanczyk, J. S.

Comparison of the Effects of Iodine and Iodide on Thyroid Function in Humans

The present experiment in humans failed to confirm the differential effect of I(sub 2) on maintenance of serum T(sub 4) concentrations relative to the effects of I(-) that was observed in prior experiments in rats. The reaction of I(sub 2) with metabolites of thyroid hormones in the intestine that appears responsible for this effect in rats probably also exists at some level in humans. The present results suggest that the concentrations of such metabolites in the human intestinal tract are too small to significantly affect circulating concentration of T(sub 4). However, based on the elevations in TSH, there should be some concern over the potential impacts of chronic consumption of iodine in drinking water.

Robison, Linda M.

Thermophysical Property Measurements of Indium Iodide Crystals

InI single crystals are a promising room temperature detector material for X-rays and γ-rays. To improve crystal growth of the material by simulations, knowledge of thermophysical properties is essential, and since InI is orthorhombic, the anisotropy has to be taken into account. The temperature dependence of several thermophysical properties have been measured for InI, including the anisotropic thermal expansion, specific heat, and the thermal diffusivity in the b direction. The anisotropic thermal expansion coefficients, determined by X-ray diffraction, were α11=1.03·10-5 K-1, α22= 3.77·10-5 K-1, and α33 = 6.26·10-5 K-1. The specific heat, measured by DSC, was 0.226 J g-1 K-1 at 335K, with a temperature dependence of 9.582·10-5 J g-1 K-2. In the course of the X-ray diffraction and DSC measurements, it was shown that supposed phase changes, reported in older literature, are actually not phase changes but oxidation effects. The thermal diffusivity in the b direction, measured by the Xenon Flash method, was 0.288·10-6 m2s-1 at RT, decreasing to 0.253·10-6 m2 s-1 at 450K. In addition, the volume increase upon melting and the thermal expansion of the melt have been determined.

Martin Volz