Cyber-Informed Engineering Implementation Guide

This Implementation Guide describes the principles of Cyber-Informed Engineering (CIE) and outlines questions that engineering teams should consider during each phase of a system’s lifecycle to effectively employ these principles. It describes what it means to engineer systems in a cyber-informed way, rather than offering a comprehensive, step-by-step process or procedure for CIE implementation. This guide complements—but does not replace—the application of cybersecurity standards or practices currently in place within an organization. Engineers and technicians that design critical energy infrastructure installations can use this Implementation Guide to integrate the 12 principles of CIE into each phase of the engineering lifecycle, from concept to retirement. The guide is aimed at system or design engineers, rather than software engineers or operational cybersecurity practitioners. The engineers who design, build, operate, and maintain the physical infrastructure are best positioned to leverage a system’s engineering design to diminish the severity of cyber attacks or digital technology failures. CIE expands cybersecurity decisions into the engineering space, not by asking engineers to become cyber experts, but by calling on engineers to apply engineering tools and make engineering decisions that improve cybersecurity outcomes. CIE examines the engineering consequences that a sophisticated cyber attacker could achieve and drives engineering changes that may provide deterministic mitigations to limit or eliminate those consequences.

42 ENGINEERING↗

Advancing Nuclear Energy to Support a Net-Zero Future

Seminar for the KEPCO International Nuclear Graduate School (KINGS) in South Korea. The presentation will cover a brief introduction to INL, opportunities for advanced nuclear, and integrated energy systems.

08 HYDROGEN↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

Cybersecurity for Fast Charging EV Infrastructure

The integration of electric vehicles (EVs) into electric grid operations can potentially leave the grid vulnerable to cyberattacks from both legacy and new equipment and protocols, including extreme fast-charging infrastructure. This paper introduces a co-simulation platform to perform cyber vulnerability analysis of EV charging infrastructure and its dependencies on communications and control systems. Grid impact scenarios through linkages to power system simulation tools such as OpenDSS and vehicle infrastructure-specific attack paths are discussed. An adaptive platform that assists with predicting and solving evolving cybersecurity challenges is demonstrated with a cyber-energy emulation that accelerates the analysis of cyberattacks and system behavior.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Design of Defensive Cybersecurity Architectures for High Temperature, Gas-Cooled Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for High Temperature, Gas-Cooled Reactors (HTGRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by-design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar HTGR and describes a DCSA design process using event tree analysis so that the template may be optimized for a given HTGR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of Defensive Cybersecurity Architectures for Sodium-Cooled Fast Reactors

This report presents the design of defensive cybersecurity architectures (DCSAs) for Sodium-Cooled Fast Reactors (SFRs). A DCSA is a cybersecurity design feature that places systems into security zones in a graded approach according to the importance of the functions performed by the systems. DCSA design efforts for advanced reactors may commence as early as the system-level design phase. This design approach is consistent with the draft regulatory guide for advanced reactor cybersecurity programs (DG-5075) and enables advanced reactor designers to consider the effects of security-by design (SeBD) features on their DCSAs. Integration of DCSA design and other cybersecurity activities with the traditional design process as part of a SeBD framework may enable advanced reactor designers to improve the security posture of their plants while reducing implementation and operating costs. This report provides a DCSA template for an exemplar SFR and how the template may be optimized for a given SFR design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Master Services Agreement - Flexible Feeder/Distribution System Support: Cooperative Research and Development (Final Report)

PGE will engage NREL on a broad range of projects related to the integration of distributed energy resources (DERs) into the utility's operations. This portfolio of work could include projects focused on DER adoption models, advanced distribution management system (ADMS) and distributed energy management system (DERMS) design, DER dispatch strategy development, and DER valuation framework development. Additional topics could include long-term energy planning, renewable energy, energy efficiency and demand-side management. As well as technology evaluations and design guidance for building retrofits and new construction projects, energy and energy infrastructure planning, policies, and markets (and their analysis), energy storage, energy security and resilience (including energy system-related cybersecurity), transportation and mobility, technology integration analysis. Additionally, other assistance as requested by PGE consistent with NREL’s expertise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

Integrated Energy Systems Program Management Plan

In 2012, the U.S. Department of Energy (DOE) Office of Nuclear Energy (NE) initiated the Nuclear Energy Enabling Technology Program, which includes the Crosscutting Technology Development (CTD) portfolio of subprograms, to conduct research, development, and demonstration (RD&D) to support existing, new and advanced reactor designs and fuel cycle technologies. This program plan describes the Integrated Energy Systems (IES) Program, an element of the CTD portfolio since 2016 that seeks to improve the economic competitiveness, efficiency and environmental performance of nuclear energy systems by expanding their potential application space beyond electricity and optimizing their utilization in the context of the larger U.S. electric and non-electric energy system.

08 HYDROGEN↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Land-Based Wind Reference Architecture

This report describes a summary and the final deliverables for the Wind Reference Architecture project funded by the Department of Energy's (DOE) Wind Energy Technology Office (WETO). The project objective was to further refine the reference architecture of the existing wind power plant reference architecture developed by Idaho National Laboratory (INL) and Sandia National Laboratories (SNL) by expanding the wind turbine generator (WTG) into a separate individual wind turbine reference architecture. Additional details regarding the wind turbine system and how it integrates with a wind power plant were researched and reflected in the reference architecture. This addition is important because it allows researchers to understand the components and devices in a wind turbine, how they function and how a wind turbine integrates into a wind power plant to be able to perform cybersecurity evaluations on the system. The communication and control systems were the focus while developing this reference architecture to understand the cybersecurity posture of a wind turbine and power plant. The information technology (IT) and operational technology (OT) systems perspective are integral in helping improve the cybersecurity posture by creating a starting point to study how wind energy can be safely designed and deployed in our power grid from an integrated systems standpoint. A holistic wind power plant and turbine reference architecture and simulation was developed and made open-sourced for further research efforts.

17 WIND ENERGY↗

Cyber-Informed Engineering (CIE) Integration into Model- Based Systems Engineering (MBSE)

Engineering design in the field of industrial engineering, such as designing automated factories or warehouses, is critical for the effective operation of facilities. Any design flaws introduced early can result in significant capital expenses to correct. However, early-stage engineering design is inherently complex. The systems are not yet built, requiring designers to integrate various aspects, including digital engineering and cybersecurity, to support virtual representations throughout the design process. In this study, we propose an approach to integrate Cyber-Informed Engineering (CIE) principles into model-based systems engineering (MBSE). This approach facilitates the development of a digital thread for engineering systems, ensuring secure digital artifacts in the design of industrial engineering systems.

42 - ENGINEERING↗

Exploring Large Language Model Agents in Cybersecurity: A Literature Review with Experiments

The accelerated development and integration of large language model (LLM) agents have led researchers and developers to explore their effectiveness in cybersecurity, specifically with penetration testing (pentesting). Recent research efforts have attempted to use LLM agents to automate the process of pentesting because of the cost and time requirements that are required to perform a manual review. However, not all of the tools perform as expected. This paper reviews some of the newest and most popular autonomous pentesting frameworks, highlighting the capabilities and limitations of each one with the goal of providing the components needed to successfully and effectively build an autonomous pentesting agent in the future.

97 MATHEMATICS AND COMPUTING↗

Automation of Vulnerability and Patch Management: Information Extraction, Association, and Optimization

Vulnerability and patch management is an integral part of a robust cybersecurity program, yet it grows increasingly complex due to the sheer amount of data that must be analyzed. Particularly in Operational Technology (OT) environments, analysis must be done manually because of the lack of automated solutions. Additionally, there are many steps in this process, from the initial discovery of the vulnerability to the implementation of its remediation, and each step in the process requires different data in order to be performed effectively. In this work, we provide approaches and strategies to assist operators in industrial or OT environments throughout the vulnerability management cycle. Security advisories provide key information about mitigation strategies, or actions that can be taken when a patch is unavailable or cannot be installed. Details of these strategies are not shared in public vulnerability databases and must be found manually. We approach this problem by designing a solution to automatically identify that information within vendor security advisories and retrieve it for operator use. We start with an approach that requires domain-specific knowledge of certain frequently-seen reference websites. Next, an approach that can work on an arbitrary website but relies on certain keywords. Finally, an approach that uses Natural Language Processing (NLP) methods and does not require specific knowledge or keywords. Each of these approaches is more general than its predecessor; we demonstrate high accuracy for all approaches Advisories also often contain details of affected products in non-standard or natural language formats. While this information can be easily understood when read by an operator, the non-standard format acts as a barrier to effective automation. We provide an approach for the first step in this process: identifying vendors in security advisories and mapping them to a standard framework for representing digital assets and software products. We evaluate five established string similarity algorithms, plus one of our own design that combines string similarity and information theory, on the task of mapping vendors to their corresponding entries in the Common Platform Enumeration (CPE) repository. Our results show that our proposed metric outperforms all others. Due to the constraints on time, finances, and personnel for organizations, Large Language Models (LLMs) may seem like attractive opportunities for security operators to speed up information gathering; however, it is still not clear whether LLMs can handle vulnerability management tasks well. To answer this question, we perform an empirical study of LLMs’ ability to provide consistent, accurate information about vulnerabilities in order to guide organizations in their adoption of LLMs. We observe poor performance for all models tested, suggesting that these models are not well-suited to the consistent retrieval of accurate vulnerability information. Finally, once vulnerabilities have been identified and any additional information has been obtained, operators must decide which remediation actions to implement based on their available resources. This already-complex problem becomes even more so when we consider that a vulnerability may have multiple avenues for remediation. We formulate this scenario as two knapsack problems and provide solutions, which we then compare against several existing strategies for vulnerability prioritization seen in real operational environments.

McClanahan, Kylie↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DEReliction: A Cybersecurity Vulnerability Assessment Methodology for Distributed Energy Resources

With the increasing integration of Distributed Energy Resources (DER) into the electric grid, maintaining grid reliability and resilience requires that these devices remain secure. This paper discusses a cybersecurity vulnerability assessment methodology that incorporates best practices from Sandia National Laboratories, SANS Institute, OWASP Foundation, and other web and Internet of Things (IoT) penetration testing (“pen testing”) programs, courses, and frameworks for assessing the security posture of devices. The methodology involves five sequential steps: (1) Collect Public Information, (2) Extract Hardware Details, (3) Inventory Software Components, (4) Identify Vulnerabilities, and (5) Test Vulnerabilities. Each step uncovers potential weaknesses in both hardware and software components of DER devices, considering adversary tactics, techniques, and procedures (TTPs), and potential attack vectors along the way. The results from the execution of this method on multiple residential- and small commercial-scale photovoltaic (PV) inverters reveled hardware and software vulnerabilities, which highlight the benefit of taking a methodical approach to discover vulnerabilities. While the specific vulnerability details are not shared here, a generalized overview of findings underscore the importance of robust security assessments for DER devices. Adoption of an assessment framework of this kind will identify and mitigate cybersecurity threats and bolster the resilience of DER-integrated electric grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗