Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Dependence of divertor turbulence on plasma density and current in TCV

To reliably predict the distribution of heat and particle fluxes at the target plates of tokamaks, a comprehensive understanding of turbulence throughout the entire Scrape-Off-Layer (SOL) is imperative. This study examines divertor turbulence systematically across a broad parameter range on the TCV tokamak, including variations in magnetic field direction, plasma current I p ∈ [140,320] kA, edge safety factor q 95 ∈ [2.6,4.7] and Greenwald fraction f G ∈ [0.18,0.6]. The TCV X-point Gas Puff Imaging (GPI) system is used to measure 2D filament properties in the inner and outer divertor region. The fluctuation levels in the divertor are found to strongly increase with density (to 80% over most of the SOL) while remaining insensitive to I p . The previously identified divertor-localized filaments (DLF), located on the bad curvature side of the outer divertor leg, are found to be a common feature on TCV, while no filaments are observed in the PFR. DLFs are present over most of the parameter space and in both field directions. However, they are absent, or appear only closer to the target, for sufficiently large Λ div ≳ 10 or q 95 ≳ 3.7. Across both I p and f G scans, some clear trends with Λ div are found for divertor filament sizes and velocities, and with target fall-off lengths of density and heat flux profiles at the outer target. This study provides important experimental insights to turbulent transport in the divertor also for comparison with self-consistent, turbulence simulations and extrapolation to future reactor conditions.

cross-field transport↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Chandra Discovery of a Candidate Hyperluminous X-Ray Source in MCG+11-11-032

We present a multiwavelength analysis of MCG+11-11-032, a nearby active galactic nucleus (AGN), with a unique classification as being both a binary and a dual AGN candidate. With new Chandra observations, we aim to resolve any dual AGN system via imaging data and search for signs of a binary AGN via analysis of the X-ray spectrum. Analyzing the Chandra spectrum, we find no evidence of the previously suggested double-peaked Fe Kα lines; the spectrum is instead best fit by an absorbed power law with a single Fe Kα line, as well as an additional line centered at ≈7.5 keV. The Chandra observation reveals faint, soft, and extended X-ray emission, possibly linked to low-level nuclear outflows. Further analysis shows evidence for a compact hard source—MCG+11-11-032 X2—located 3.″3 from the primary AGN. Modeling MCG+11-11-032 X2 as a compact source, we find that it is relatively luminous (L2–10 keV=1.5−0.5+0.9×1041erg s$^{−1}$), and the location is coincident with a compact and off-nuclear source resolved in Hubble Space Telescope infrared (F105W) and optical (F621M, F547M) bands. Pairing our X-ray results with a 144 MHz radio detection at the host galaxy location, we observe X-ray and radio properties similar to those of ESO 243-49 HLX-1, suggesting that MCG+11-11-032 X2 may be a hyperluminous X-ray source. This detection with Chandra highlights the importance of a high-resolution X-ray imager as well as how previous binary AGN candidates detected with large-aperture instruments can benefit from high-resolution follow-up. Future spatially resolved optical spectra, and deeper X-ray observations, can better constrain the origin of MCG+11-11-032 X2.

79 ASTRONOMY AND ASTROPHYSICS↗

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY↗

Image Reconstruction from Sparse-view Data Acquired with Portable X-ray Devices

• Portable X-ray systems enable on-site 3D imaging for non-invasive inspection of suspicious packages and explosives. • Existing reconstruction algorithms (e.g., FDK or Feldkamp, Davis and Kress) require hundreds of projections over 360 degrees. • Sparse-view scan reduces scanning time and setup effort, making it ideal for field use in time&#x2;critical scenarios. • Existing reconstruction algorithms introduce severe artifacts when applied to sparse-view data. • We developed a total variation (TV)-based optimization algorithm for yielding 3D images from sparse-view data collected with our portable X-ray imaging system.

Xia, Dan [University of Chicago, Chicago, IL]↗

Quantitative radiography for determining density fluctuations in HED experiments

We have developed a method to extract density fluctuation measurements from x-ray radiographs of high-energy density (HED) instability growth and turbulence experiments. We use this information to calculate density fluctuation statistics for constraining the performance of turbulent mix models in HED systems. The density calculation combines image filtering, removal of systemic effects such as backlighter variation, calculation of transmission across multiple materials, and use of tracer materials to generate an approximate single-material density field. From the density map, we calculate both average density and a variance-like moment b (density-specific-volume covariance), which we compare to our models. We infer both quantities from a single image, which is significantly more information than the historic single scalar mix width measurements. We also develop a method of analyzing simulation outputs that incorporate both the density fluctuation metric from a turbulence model and the bulk material maps from the hydrodynamic code. This analysis helps address the question of how to initialize the simulations for best comparison to data from systems with large separations of scale in the mixing perturbation initial condition. We find that our data analysis method yields 1D average density and b curves with similar morphology and amplitudes as those from preliminary simulation comparisons.

47 OTHER INSTRUMENTATION↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

Quantum Light Imaging of the Plant Root─Rhizobacteria─System Using iLOV Fluorescence

It has been demonstrated recently that the use of specific quantum states of light for two-photon microscopy can lead to a substantial reduction of the intensity of light needed for the imaging of biological objects. This opens new ways to better understand the delicate mechanisms of the interactions of living organisms in the rhizosphere on an extended time scale without optical damage or alteration of their native behavior. Herein, we report a successful realization of entangled two-photon excited fluorescence microscopy of wheat plant roots and a set of biological samples, including purified iLOV protein, bacterial cells expressing iLOV, and combination of these under an extremely low excitation intensity. The entangled two-photon coupling strength of iLOV was modeled using electronic structure calculations which demonstrated that the FMN chromophore in the iLOV protein has an entangled two-photon absorption (ETPA) cross section that is large enough for imaging using weak quantum light for fluorescence excitation. Successful imaging of plant-associated Pantoea sp. YR343 cells expressing iLOV validates the feasibility of using iLOV as a molecular label for characterizing plant-microbe interactions based on entangled photon imaging. In conclusion, the results demonstrate the advantageous use of entangled photon imaging under noninvasive and nondestructive conditions.

Varnavksi, Oleg [Univ. of Michigan, Ann Arbor, MI ↗

Ghost imaging second harmonic generation microscopy

A system and methods for ghost imaging second harmonic generation microscopy. Imaging data is collected in parallel, providing faster imagine reconstruction and enabling reconstruction in scattering environments. Ghost imaging, split light beam interacting with a target and a second light beam unimpeded and not required to pass through the same background. A second harmonic generation image is reconstructed from the detected photons.

Wiederrecht, Gary P.↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Sparse-Data Deep Learning Strategies for Radiographic Non-Destructive Testing

Radiography is an imaging technique used in a variety of applications, such as medical diagnosis, airport security, and nondestructive testing. We present a deep learning system for extracting information from radiographic images. We perform various prediction tasks using our system, including material classification and regression on the dimensions of a given object that is being radiographed. Our system is designed to address the sparse-data issue for radiographic nondestructive testing applications. It uses a radiographic simulation tool for synthetic data augmentation, and it uses transfer learning with a pre-trained convolutional neural network model. Using this system, our preliminary results indicate that the object geometry regression task saw an improvement of 70% in the R-squared value when using a multi-regime model. In addition, we increase the performance of the object material classification tasks by utilizing data from different imaging systems. In particular, using neutron imaging improved the material classification accuracy by 20% when compared to x-ray imaging.

convolutional neural networks↗

A unified large language model–based framework for heterogeneous PV image diagnosis

With advances in imaging technologies, modern photovoltaic (PV) systems generate large volumes of heterogeneous image data, including visible, electroluminescence (EL), and infrared (IR) images. Existing PV image analysis models, particularly deep learning approaches, are typically task-specific and lack cross-modality generalization. To address this limitation, this paper proposes an open-source large language model (LLM)–based unified framework for heterogeneous PV image diagnostics. Through task-aware diagnostic prompting, the framework enables analysis of visible, EL, and IR images within a single pipeline, supporting both zero-shot and few-shot inference and binary and multiclass classification. It is compatible with state-of-the-art multimodal LLMs, including ChatGPT, Gemini, Claude, Qwen, and CLIP. The framework is evaluated on PV module condition classification (clean, soiling, snow, hail, and bird droppings) using visible images, cell crack detection using EL images, and hotspot detection using IR images. GPT-5.1 in few-shot mode achieves the best performance, with classification accuracy exceeding 97.3%. Open-source models such as Qwen and CLIP also deliver competitive results on visible images (around 90% accuracy), though their performance is more limited on EL and IR modalities. On the full ELPV dataset, the framework achieves 83.5% zero-shot accuracy, within 2.8% of the supervised CNN baseline, confirming scalability to larger benchmarks. Practical aspects such as reproducibility, response latency, and confidence estimation are systematically analyzed. The framework operates across PV image modalities without modality- or task-specific training, making it well suited as a rapid pre-screening tool to support downstream detailed diagnostics. A benchmark dataset of diverse labeled PV images is also released.

Li, Baojie↗

Leveraging a Neural Network-Enhanced Reproducing Kernel Particle Method for Multiphysics Degradation Modeling of Energy Storage Materials

Energy storage materials exhibit strong electro-chemo-mechanical coupling and highly anisotropic material properties, contributing to the formation and propagation of micro-cracking during charge/discharge cycling and resulting in reduced performance and service life. A coupled electro-chemo-mechanical reproducing kernel particle method (RKPM) formulation has been developed to analyze this system. With microstructural images supplied by the National Renewable Energy Laboratory (NREL), pixel-based model construction by RKPM is used to represent the complex material microstructures that dictate the coupled physics of these systems. Traditional electro-chemo-mechanical models rely on mesh-based finite element methods, which can lead to difficulties in meshing such complex geometries and capturing crack propagation due to mesh dependency. Here, a neural network-enhanced reproducing kernel particle method (NN-RKPM) [1, 2] is introduced to effectively model damage and crack propagation in the material microstructures; the location, orientation, and solution transition near a localization are automatically captured by superimposed block-level NN optimizations. This NN enrichment approach allows for effective modeling of localizations via a fixed background discretization, relieving tedious efforts for adaptive refinement in traditional mesh-based methods. Applications to the heterogeneous microstructures of Li-ion battery cathodes will be presented to demonstrate the effectiveness of the proposed methods. NN-RKPM is additionally used to inform how crack opening and closure in turn affect the coupled chemical equations and material microstructure. Reference: [1] Baek, J., Chen, J. S., Susuki, K., "Neural Network enhanced Reproducing Kernel Particle Method for Modeling Localizations," International Journal for Numerical Methods in Engineering, Vol. 123, pp 4422-4454, https://doi.org/10.1002/nme.7040, 2022. [2] Baek, J., Chen, J. S., "A Neural Network-Based Enrichment of Reproducing Kernel Approximation for Modeling Brittle Fracture", Computer Methods in Applied Mechanics and Engineering Vol. 410, 116590, 2024.

degradation↗

Multiphysics Degradation Modeling of Energy Storage Materials via RKPM with a Neural Network-Enhancement

In energy storage materials, strong electrochemical-mechanical coupling and highly anisotropic material properties contribute to the formation and propagation of micro-cracking during charge/discharge cycling, resulting in reduced performance and service life. A coupled electro-chemo-mechanical reproducing kernel particle method (RKPM) formulation is developed, and a patch-test is formulated to certify optimal convergence of the proposed RKPM method for the coupled physics system. With microstructural images supplied by the National Renewable Energy Laboratory (NREL), pixel-based model construction by RKPM is then used to represent the complex material microstructures for modeling the coupled physics of these systems. Further, a neural network-enhanced reproducing kernel particle method (NN-RKPM) [1, 2] is introduced to effectively model damage and crack propagation in the material microstructures; the location, orientation, and solution transition near a localization are automatically captured by superimposed block-level NN optimizations. This NN enrichment approach allows for effective modeling of localizations via a fixed background discretization, relieving tedious efforts for adaptive refinement in traditional mesh-based methods. Applications to the heterogeneous microstructures of Li-ion battery cathodes will be presented to demonstrate the effectiveness of the proposed methods. Reference: [1] Baek, J., Chen, J. S., Susuki, K., "Neural Network enhanced Reproducing Kernel Particle Method for Modeling Localizations," International Journal for Numerical Methods in Engineering, Vol. 123, pp 4422-4454, https://doi.org/10.1002/nme.7040, 2022. [2] Baek, J., Chen, J. S., "A Neural Network-Based Enrichment of Reproducing Kernel Approximation for Modeling Brittle Fracture", Computer Methods in Applied Mechanics and Engineering Vol. 410, 116590, 2024.

electro-chemo-mechanical coupling↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗