Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging Complex Subsurface Structures for Geothermal Exploration at Pirouette Mountain and Eleven-Mile Canyon in Nevada

Accurate imaging of subsurface complex structures with faults is crucial for geothermal exploration because faults are generally the primary conduit of hydrothermal flow. It is very challenging to image geothermal exploration areas because of complex geologic structures with various faults and noisy surface seismic data with strong and coherent ground-roll noise. In addition, fracture zones and most geologic formations behave as anisotropic media for seismic-wave propagation. Properly suppressing ground-roll noise and accounting for subsurface anisotropic properties are essential for high-resolution imaging of subsurface structures and faults for geothermal exploration. We develop a novel wavenumber-adaptive bandpass filter to suppress the ground-roll noise without affecting useful seismic signals. This filter adaptively exploits both characteristics of the lower frequency and the smaller velocity of the ground-roll noise than those of the signals. Consequently, this filter can effectively differentiate the ground-roll noise from the signal. We use our novel filter to attenuate the ground-roll noise in seismic data along five survey lines acquired by the U.S. Navy Geothermal Program Office at Pirouette Mountain and Eleven-Mile Canyon in Nevada, United States. We then apply our novel anisotropic least-squares reverse-time migration algorithm to the resulting data for imaging subsurface structures at the Pirouette Mountain and Eleven-Mile Canyon geothermal exploration areas. The migration method employs an efficient implicit wavefield-separation scheme to reduce image artifacts and improve the image quality. Our results demonstrate that our wavenumber-adaptive bandpass filtering method successfully suppresses the strong and coherent ground-roll noise in the land seismic data, and our anisotropic least-squares reverse-time migration produces high-resolution subsurface images of Pirouette Mountain and Eleven-Mile Canyon, facilitating accurate fault interpretation for geothermal exploration.

15 GEOTHERMAL ENERGY↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Data-driven picosecond X-ray imaging for quantitative plasma-induced shock characterization

Imaging dynamic events, especially shockwave behavior, is key to advancing high-energy-density (HED) research. Recent advances in fourth- and fifth-generation X-ray light sources allow for high-resolution imaging of fast phenomena, but limited beam time necessitates maximizing data acquisition. We present a benchtop-scale pulsed plasma device submerged in liquid heptane, capable of generating dynamic events at rates exceeding 10 Hz, supporting the field’s data-driven goals by producing large, high-quality imaging datasets. Using X-ray phase contrast imaging (XPCI) at the Advanced Photon Source, we imaged weak shockwaves (Mach ~ 1.2) in heptane interacting with plasma-induced cavitation bubbles, causing deviation from Rankine-Hugoniot behavior; to our knowledge, this represents the first direct imaging of such interaction. Our quantitative analysis offers insight into weak shock phenomena and energy-focusing applications in pulsed plasmas. These results highlight the potential for large datasets to advance dynamic HED research at current light source facilities, and have implications for fields such as inertial confinement fusion, plasma-enhanced chemical processing, and biomedical applications.

36 MATERIALS SCIENCE↗

Galaxy Cruise: Deep Insights into Interacting Galaxies in the Local Universe

Abstract We present the first results from GALAXY CRUISE, a community (or citizen) science project based on data from the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP). The current paradigm of galaxy evolution suggests that galaxies grow hierarchically via mergers, but our observational understanding of the role of mergers is still limited. The data from HSC-SSP are ideally suited to improve our understanding with improved identifications of interacting galaxies thanks to the superb depth and image quality of HSC-SSP. We launched a community science project, GALAXY CRUISE, in 2019 and have collected over two million independent classifications of 20686 galaxies at z < 0.2. We first characterize the accuracy of the participants’ classifications and demonstrate that it surpasses previous studies based on shallower imaging data. We then investigate various aspects of interacting galaxies in detail. We show that there is a clear sign of enhanced activities of super-massive black holes and star formation in interacting galaxies compared to those in isolated galaxies. The enhancement seems particularly strong for galaxies undergoing violent mergers. We also show that the mass growth rate inferred from our results is roughly consistent with the observed evolution of the stellar mass function. The second season of GALAXY CRUISE is currently underway and we conclude with future prospects. We make the morphological classification catalog used in this paper publicly available at the GALAXY CRUISE website, which will be particularly useful for machine-learning applications.

Tanaka, Masayuki↗

Hyper Spectral Anomaly Detection

Anomaly detection is a common machine learning (ML) task with growing importance in the fields of imaging, quality assurance, and multiple security related disciplines. Anomaly detection is more difficult than traditional machine learning methods due to the inherent unlabeled nature of the datasets. Existing anomaly detection architectures commonly face challenges with explainability, retaining information related to the relational structure of the data, and false positive rates. Hyperspectral Imaging Anomaly Detection (HSI) is a statistical model that employs vertex and edge weighted graphs to preserve the data’s relationships on different topographical scales. The model is able to generalize from anomaly detection in 2D images to novel datasets related to cyber-security. Furthermore, the use of multi-spectral and other filtering methods results in fewer false positives and increases the explainability of model predictions. When applying HSI to cyber-security datasets, we are able to successfully detect malicious activity with a relatively high degree of accuracy.

97 - MATHEMATICS AND COMPUTING↗

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Super-resolution and segmentation deep learning for breast cancer histopathology image analysis

Traditionally, a high-performance microscope with a large numerical aperture is required to acquire high-resolution images. However, the images’ size is typically tremendous. Therefore, they are not conveniently managed and transferred across a computer network or stored in a limited computer storage system. As a result, image compression is commonly used to reduce image size resulting in poor image resolution. Here, we demonstrate custom convolution neural networks (CNNs) for both super-resolution image enhancement from low-resolution images and characterization of both cells and nuclei from hematoxylin and eosin (H&E) stained breast cancer histopathological images by using a combination of generator and discriminator networks so-called super-resolution generative adversarial network-based on aggregated residual transformation (SRGAN-ResNeXt) to facilitate cancer diagnosis in low resource settings. The results provide high enhancement in image quality where the peak signal-to-noise ratio and structural similarity of our network results are over 30 dB and 0.93, respectively. The derived performance is superior to the results obtained from both the bicubic interpolation and the well-known SRGAN deep-learning methods. In addition, another custom CNN is used to perform image segmentation from the generated high-resolution breast cancer images derived with our model with an average Intersection over Union of 0.869 and an average dice similarity coefficient of 0.893 for the H&E image segmentation results. Finally, we propose the jointly trained SRGAN-ResNeXt and Inception U-net Models, which applied the weights from the individually trained SRGAN-ResNeXt and inception U-net models as the pre-trained weights for transfer learning. The jointly trained model’s results are progressively improved and promising. We anticipate these custom CNNs can help resolve the inaccessibility of advanced microscopes or whole slide imaging (WSI) systems to acquire high-resolution images from low-performance microscopes located in remote-constraint settings.

60 APPLIED LIFE SCIENCES↗

Application of Monte Carlo Algorithms to Cardiac Imaging Reconstruction

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One ofthe main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component,which is particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT,no timing information can be retrieved to locate the primary source photons. Monte Carlo methods allow anevent-by-event simulation of the scattering kinematics, which can be incorporated into a model of the imagingsystem response. This approach was adopted in the late Nineties by several authors, and recently took advantageof the increased computational power made available by high-performance CPUs and GPUs. These recent developmentsenable a fast image reconstruction with improved image quality, compared to deterministic approaches.Deterministic approaches are based on energy-windowing of the detector response, and on the cumulative estimateand subtraction of the scattering component. In this paper, we review the main strategies and algorithms tocorrect the scattering effect in SPECT and focus on Monte Carlo developments, which nowadays allow the threedimensionalreconstruction of SPECT cardiac images in a few seconds.

Pharmacology & Pharmacy↗

Making Invisible Visible: Data-Driven Seismic Inversion With Spatio-Temporally Constrained Data Augmentation

Deep learning and data-driven approaches have shown great potential in scientific domains. The promise of data-driven techniques relies on the availability of a large volume of high-quality training datasets. Due to the high cost of obtaining data through expensive physical experiments, instruments, and simulations, data augmentation techniques for scientific applications have emerged as a new direction for obtaining scientific data recently. However, existing data augmentation techniques originating from computer vision yield physically unacceptable data samples that are not helpful for the domain problems that we are interested in. In this article, we develop new data augmentation techniques based on convolutional neural networks. Specifically, our generative models leverage different physics knowledge (such as governing equations, observable perception, and physics phenomena) to improve the quality of the synthetic data. To validate the effectiveness of our data augmentation techniques, we apply them to solve a subsurface seismic full-waveform inversion using simulated CO 2 leakage data. Our interest is to invert for subsurface velocity models associated with very small CO 2 leakage. We validate the performance of our methods using comprehensive numerical tests. Here via comparison and analysis, we show that data-driven seismic imaging can be significantly enhanced by using our data augmentation techniques. Particularly, the imaging quality has been improved by 15% in test scenarios of general-sized leakage and 17% in small-sized leakage when using an augmented training set obtained with our techniques.

58 GEOSCIENCES↗

Physics constrained unsupervised deep learning for rapid, high resolution scanning coherent diffraction reconstruction

By circumventing the resolution limitations of optics, coherent diffractive imaging (CDI) and ptychography are making their way into scientific fields ranging from X-ray imaging to astronomy. Yet, the need for time consuming iterative phase recovery hampers real-time imaging. While supervised deep learning strategies have increased reconstruction speed, they sacrifice image quality. Furthermore, these methods’ demand for extensive labeled training data is experimentally burdensome. Here, we propose an unsupervised physics-informed neural network reconstruction method, PtychoPINN, that retains the factor of 100-to-1000 speedup of deep learning-based reconstruction while improving reconstruction quality by combining the diffraction forward map with real-space constraints from overlapping measurements. In particular, PtychoPINN gains a factor of 4 in linear resolution and an 8 dB improvement in PSNR while also accruing improvements in generalizability and robustness. This blend of performance and computational efficiency offers exciting prospects for high-resolution real-time imaging in high-throughput environments such as X-ray free electron lasers (XFELs) and diffraction-limited light sources.

97 MATHEMATICS AND COMPUTING↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Machine Learning Approach to Quantitative Analysis of Enamel Microstructure from Scanning Electron Microscopy Images

Dental enamel, the outermost tissue of mammalian teeth, must withstand a lifetime of wear and cyclic contact. To meet this demand, enamel possesses a combination of high hardness and resistance to fracture, properties that are typically mutually exclusive. The impressive damage tolerance has been attributed largely to decussation of the enamel rods, the principal unit of its microstructure. As such, enamel is inspiring the design of next‐generation structural materials. However, quantitative descriptions of the decussated enamel rod microstructure remain limited due to challenges encountered in applying computed tomography and in acquiring quality images appropriate for traditional digital processing methods. Here, a machine learning segmentation method is applied to images of the enamel obtained using scanning electron microscopy to support quantitative analysis of the microstructure. A pretrained convolutional neural network is used to expand the input training image dataset to allow the training of a random forest classifier, which ultimately segments the image with a very small training set ( n = 3 images). A validation of this segmentation method is presented, in addition to its application to calculate relevant microstructural parameters for images of tooth enamel from selected mammalian species. The methodology applied here is equally applicable to other hard tissues.

36 MATERIALS SCIENCE↗

Image-domain DAS 3D VSP elastic transmission tomography

SUMMARY Full-wavefield elastic imaging of active-source seismic data acquired by downhole receivers commonly offers higher-resolution subsurface images in the vicinity of a borehole compared to conventional surface seismic data sets, which can lack higher-frequency wavefield components due to longer travel paths and increased attenuation. An increasingly used approach for downhole acquisition is vertical seismic profiling (VSP), which has become more attractive when coupled with distributed acoustic sensing (DAS) using optical fibres installed in wells. The main difficulty for generating high-quality images with full-wavefield imaging tools for DAS VSP data, though, is the need for an accurate velocity model. To build plausible velocity models using active-source DAS VSP data, we adopt a 3-D image-domain elastic transmission tomography technique, originally developed for surface-recorded passive (microseismic) data, by exchanging the source and receiver positions (i.e. reciprocity) to mimic a passive-seismic surface monitoring scenario. The inversion approach exploits various images for each source constructed through time-reverse imaging (TRI) of downgoing P- and S-wave first-arrival waveforms. The TRI process uses the kinetic term of the (extended) PS energy imaging condition that exhibits sufficient sensitivity to velocity model errors. The method automatically updates the P- and S-wave velocity models to optimize image focusing via adjoint-state inversion. We illustrate the efficacy of the adopted elastic inversion technique using an active-source DAS 3-D VSP field data set acquired in the North Slope of Alaska. The numerical experiments demonstrate that the inverted elastic velocity models can be further used in full-wavefield acoustic/elastic imaging algorithms to obtain accurate subsurface images.

Oren, Can (ORCID:000000019534265X)↗

SINGLE: Atomic-resolution structure identification of nanocrystals by graphene liquid cell EM

Analysis of the three-dimensional (3D) structures of nanocrystals with solution-phase transmission electron microscopy is beginning to reveal their unique physiochemical properties. We developed a “one-particle Brownian 3D reconstruction method” based on imaging of ensembles of colloidal nanocrystals using graphene liquid cell electron microscopy. Projection images of differently rotated nanocrystals are acquired using a direct electron detector with high temporal (<2.5 ms) resolution and analyzed to obtain an ensemble of 3D reconstructions. Here, we introduce computational methods required for successful atomic-resolution 3D reconstruction: (i) tracking of the individual particles throughout the time series, (ii) subtraction of the interfering background of the graphene liquid cell, (iii) identification and rejection of low-quality images, and (iv) tailored strategies for 2D/3D alignment and averaging that differ from those used in biological cryo–electron microscopy. Our developments are made available through the open-source software package SINGLE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MemXCT: Design, Optimization, Scaling, and Reproducibility of X-Ray Tomography Imaging

Here, this work extends our previous research entitled "MemXCT: Memory-centric X-ray CT Reconstruction with Massive Parallelization" that was originally published at SC19 conference (Hidayetoglu et al., 2019) with reproducibility of the computational imaging performance. X-ray computed tomography (XCT) is regularly used at synchrotron light sources to study the internal morphology of materials at high resolution. However, experimental constraints, such as radiation sensitivity, can result in noisy or undersampled measurements. Further, depending on the resolution, sample size and data acquisition rates, the resulting noisy dataset can be in the order of terabytes. Advanced iterative reconstruction techniques can produce high-quality images from noisy measurements, but their computational requirements have made their use an exception rather than the rule. We propose a novel memory-centric approach that avoids redundant computations at the expense of additional memory complexity. We develop a memory-centric iterative reconstruction system, MemXCT, that uses an optimized SpMV implementation with two-level pseudo-Hilbert ordering and multi-stage input buffering. We evaluate MemXCT on various supercomputer architectures involving KNL and GPU. MemXCT can reconstruct a large (11Kx11K) mouse brain tomogram in 10 seconds using 4096 KNL nodes (256K cores). The results presented in our original article at the SC19 were based on large-scale supercomputing resources. The MemXCT application was selected for the Student Cluster Competition (SCC) Reproducibility Challenge and evaluated on a variety of cloud computing resources by universities around the world in the SC20 conference. We summarize the results of the top-ranked SCC Reproducibility Challenge teams and identify the most pertinent measures for ensuring the reproducibility of our experiments in this article.

47 OTHER INSTRUMENTATION↗