Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Icarus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Measurement of Multi-Proton Zero Pion Final States with the NuMI Neutrino Beam at ICARUS

Evidence suggests that charge-parity (CP) symmetry, or the principle that matter and antimatter must obey the same physics, might be violated in neutrino flavor mixing. The next-generation long-baseline experiment DUNE is designed to confirm whether or not neutrinos oscillate differently from antineutrinos. The magnitude of systematic uncertainties contributing to current long-baseline oscillation measurements, if left unimproved, is enough to jeopardize DUNE's ability to measure CP violation. Neutrino cross section measurements on argon targets are an essential input for improving neutrino interaction modelling and reducing the systematic uncertainties before DUNE turns on. The ICARUS experiment at Fermilab is well suited perform such measurements due to the NuMI neutrino beam providing neutrinos at the same energy as DUNE's first oscillation maximum. This work presents a measurement of muon neutrino charged-current interactions with multiple energetic protons and zero final state mesons in ICARUS. Multi-proton topologies are sensitive to contributions from two-particle two hole effects as well as resonant pion production and subsequent absorption via final state interactions (FSI) within the argon nucleus. Single-differential cross sections are measured in lab-frame opening angles and transverse kinematic imbalance variables, characterizing the initial sate momentum sharing between correlated nucleons and strength of FSI in argon.

Smedley, John [Rochester U.] (ORCID:00000002848611↗

ELECTRON SHOWER RECONSTRUCTION IN THE ICARUS EXPERIMENT

This dissertation presents a study in the field of neutrino physics. Neutrinos are fundamental particles that are electrically neutral and have extremely small mass, allowing them to traverse matter with very little interaction. Because of this property, neutrinos are exceptionally difficult to detect. Nevertheless, understanding their behavior is essential for addressing fundamental questions about the origin of the Universe and the properties of matter. This work focuses on the reconstruction of electron showers produced by interactions of electron neutrinos (𝜈𝑒) in the ICARUS experiment, located at the Fermi National Accelerator Laboratory in the United States. ICARUS employs a liquid argon time projection chamber detector, which is capable of recording with high precision the tracks left by particles produced in neutrino interactions. The main objective of this research is to improve the reconstruction algorithms and techniques used to identify and characterize these electron showers, enhancing metrics such as completeness, defined as the fraction of correctly reconstructed signals, and purity, which quantifies how much of the reconstructed signal truly belongs to the candidate event. These improvements are crucial for reducing false positives and increasing the accuracy of electron photon discrimination. Consequently, this work directly contributes to improved neutrino oscillation analyses and to a deeper understanding of neutrino properties.

Salmoria, Gabrieli [Parana Tech. Fed. U., Toledo]↗

Comparing CRT and Pandora Tagged Tracks in ICARUS

The ICARUS Liquid Argon Time Projection Chamber (LArTPC) is used to investigate short-baseline neutrino oscillations and the possible existence of sterile neutrinos. To aid in identifying and rejecting cosmic ray backgrounds, the system is outfitted with external Cosmic Ray Taggers (CRTs). The CRT is able to measure more tracks and at a wider range of angles, useful in further detailing future calibrations. This project compared the most probable values (MPVs) of charge deposition between CRT tagged and TPC tagged tracks. The Y-Z maps of charge scale for both datasets show a strong correlation, not just in their overall structure, but also in how they reflect known detector effects. Both reconstruction paths showed similar structures in their charge distribution, such as less effective wire section or mechanical support, confirming that CRT-tagged tracks, despite being external, respond to the same calibration landscape as Pandora tracks, validating previous Pandora reconstructions and values. Overall, the analysis supports the idea that the CRT tags are a useful addition to ICARUS calibration efforts. Their broad angular range and independence from Pandora reconstruction make them a helpful secondary tool and a potential asset in extending calibration across the detector volume.

Thayer, Abbie [Fermilab; Colorado State U.]↗

First results from the search of $ν_μ$ disappearance with ICARUS

his work presents a search for muon neutrino disappearance signal using the ICARUS detector. ICARUS is currently working as the far detector of the Short-Baseline Neutrino (SBN) program. Its main goal is to investigate the possible oscillation of a sterile neutrino state ($\Delta m^2 \sim \text{eV}^2$), that would drive short baseline oscillations at the scale of L/E $\sim$ km/GeV. Neutrino interactions from the Booster Neutrino Beam (BNB) are investigated, looking for simple final state topology with a single muon and at least one proton (1$\mu$Np). This analysis tests the 3+1 model using the two flavor neutrino approximation, where careful consideration has been given to the systematic uncertainties arising from flux, neutrino interaction, and detector models. No statistically significant $\nu_\mu$ disappearance is observed, hence 90\% C.L. exclusion contours are reported in the $\Delta m^2_{41} - \sin^22\theta_{\mu\mu}$ parameter space.

Artero Pons, Maria [INFN, Padua; U. Padua (main)]↗

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]↗

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

Lessons from commissioning and operations of the ICARUS cryogenic system at Fermilab

Results and lessons from three years of commissioning and operations of the cryogenic and purificationsystems of the ICARUS neutrino detector installed at the Fermilab are described. The detector uses liquid argon stored in two separate containers of about 275 m 3 each. The liquid argon must be kept in very stable thermal conditions, and the contamination of electronegative impurities must be consistently kept at small fractions of parts per billion. Since its fill in early 2020, the detector has been commissioned and then operated in neutrino beams at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The results of operating the cryogenic and purification systems and lessons learned, including challenges in reaching the design electron lifetime in argon bath, operating and servicing liquid nitrogen and argon circulation pumps, argon condensers and purifiers, are described. Plans for future operations and list of recommendations are presented.

43 PARTICLE ACCELERATORS↗

Icarus Revisted: Three Decades of Radar Observations of Asteroids

Three decades after the close encounter of 1566 Icarus, which marked the beginning of asteroid radar astronomy, we had a chance to observe the asteroid afresh by using a more developed radar system, and here we present the results of the study.

Icarus asteroid radar astronomy radar cross sectio↗

The scintillation light detection system of ICARUS-T600: Hardware implementation and early results

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is taking data with the Fermilab Booster Neutrino Beam-line (BNB) in the Short Baseline Neutrino (SBN) program to search for a possible LSND-like sterile neutrino signal. A light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs) deployed behind the TPC wire chambers, has been realized to detect vacuum ultraviolet (VUV) photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray characterization of the Icarus ultrafast x-ray imager

Ultrafast x-ray imagers developed at Sandia National Laboratories are a transformative diagnostic tool in inertial confinement fusion and high energy density physics experiments. The nanosecond time scales on which these devices operate are a regime with little precedent, and applicable characterization procedures are still developing. This paper presents pulsed x-ray characterization of the Icarus imager under a variety of illumination levels and timing modes. Results are presented for linearity of response, absolute sensitivity, variation of response with gate width, and image quality.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overhaul and installation of the ICARUS-T600 liquid argon TPC electronics for the FNAL Short Baseline Neutrino program

The ICARUS T600 liquid argon (LAr) time projection chamber (TPC) underwent a major overhaul at CERN in 2016–2017 to prepare for the operation at FNAL in the Short Baseline Neutrino (SBN) program. This included a major upgrade of the photo-multiplier system and of the TPC wire read-out electronics. The full TPC wire read-out electronics together with the new wire biasing and interconnection scheme are described. The design of a new signal feed-through flange is also a fundamental piece of this overhaul whose major feature is the integration of all electronics components onto the signal flange. Initial functionality tests of the full TPC electronics chain installed in the T600 detector at FNAL are also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of muon neutrino charged-current quasielasticlike cross section using off-axis NuMI beam at ICARUS

This paper presents the first neutrino cross-section measurement from the ICARUS detector at Fermilab, using Neutrinos at the Main Injector (NuMI) beam data collected from two beam operation periods corresponding to 2.5 × 10 20 protons-on-target in neutrino beam mode. The signal is defined by events with no pions produced in the final state, a topology dominated by charged-current quasielasticlike signatures. The measurement is reported as flux-averaged differential cross sections as functions of kinematic variables that provide sensitivity to the complex nuclear effects that often dominate the systematic uncertainty budgets of neutrino oscillation measurements. Specifically, this work reports cross sections in two angular variables—the angle of the outgoing lepton and the opening angle between the lepton and leading proton—and two variables characterizing the kinematic imbalance between the muon and proton in the plane transverse to the incoming neutrino. These results are compared against predictions from a variety of neutrino event generators, with p values calculated between the extracted cross sections and each prediction. Overall, the predictions agree with the data; however, the current budget of uncertainties does not yet provide sufficient discriminating power to favor a specific model.

Abd Alrahman, F. [Houston U.]↗

Online and Offline Monitoring of the ICARUS Detector

In preparation for the launch of the ICARUS -T600 far detector in the Short Baseline Neutrino program, (SBN), it is important to monitor the performance of the detector and quality of the data in real-time. Particularly important to monitor are noise levels of the TPC readout electronics, and the purity of the liquid argon in the TPC, as these can affect the overall sensitivity of the detector to detecting and reconstructing neutrino interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects of Neutrino Cross Section Measurements Using the NuMI off axis at ICARUS [Poster]

ICARUS, a Liquid Argon Time Projection Chamber, will serve as the Far Detector of the short-baseline neutrino program using the Booster beamline at Fermilab. It is 103 mrad off-axis of the NuMI beamline. Prospects for cross-section measurements and the status of the trigger system using the PMT system to collect electron and muon neutrinos from NuMI will be shown. Accurate neutrino cross-section measurements on argon are required for precise measurements of neutrino oscillation physics such as CP- violation and the ordering of the neutrino masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic Background Rejection at the ICARUS [Poster]

ICARUS is on the surface of Earth and is exposed to huge cosmic activity and is the focus for several physics analyses. In summary, the overburden is very effective in reducing the hadrons while fully eliminating the electromagnetic cosmic ray components. Exploiting the information from three sub detectors and benchmarking the method with data is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗