Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTHERMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

On the Isothermality of Solar Plasmas

Recent measurements have shown that the quiet unstructured solar corona observed at the solar limb is close to isothermal, at a temperature that does not appear to change over wide areas or with time. Some in dividual active loop structures have also been found to be nearly iso thermal both along their axis and across their cross-section. Even a complex active region observed at the solar limb has been found to be composed of three distinct isothermal plasmas. If confirmed, these r esults would pose formidable challenges to the current theoretical understanding of the thermal structure and heating of the solar corona. For example, no current theoretical model can explain the excess dens ities and lifetimes of many observed loops if the loops are in fact i sothermal. All of these measurements are based on the so-called emiss ion measure (EM) diagnostic technique that is applied to a set of opt ically thin lines under the assumption of isothermal plasma. It provi des simultaneous measurement of both the temperature and EM. However, no study has ever been carried out to quantify the uncertainties in the technique and to rigorously assess its ability to discriminate bet ween isothermal and multithermal plasmas. Such a study is the topic o f the present work. We define a formal measure of the uncertainty in the EM diagnostic technique that can easily be applied to real data. We here apply it to synthetic data based on a variety of assumed plas ma thermal distributions, and develop a method to quantitatively asse ss the degree of multithermality of a plasma.

Landi, E.↗

Simulating Thermal Cycling and Isothermal Deformation Response of Polycrystalline NiTi

A microstructure-based FEM model that couples crystal plasticity, crystallographic descriptions of the B2-B19' martensitic phase transformation, and anisotropic elasticity is used to simulate thermal cycling and isothermal deformation in polycrystalline NiTi (49.9at% Ni). The model inputs include anisotropic elastic properties, polycrystalline texture, DSC data, and a subset of isothermal deformation and load-biased thermal cycling data. A key experimental trend is captured.namely, the transformation strain during thermal cycling is predicted to reach a peak with increasing bias stress, due to the onset of plasticity at larger bias stress. Plasticity induces internal stress that affects both thermal cycling and isothermal deformation responses. Affected thermal cycling features include hysteretic width, two-way shape memory effect, and evolution of texture with increasing bias stress. Affected isothermal deformation features include increased hardening during loading and retained martensite after unloading. These trends are not captured by microstructural models that lack plasticity, nor are they all captured in a robust manner by phenomenological approaches. Despite this advance in microstructural modeling, quantitative differences exist, such as underprediction of open loop strain during thermal cycling.

Manchiraju, Sivom↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Addressing spreading pressure dependence of real adsorbed solution theory with generalized Langmuir isotherm

This work addresses spreading pressure dependence of Real Adsorbed Solution Theory (RAST) for mixed-gas adsorption equilibria using generalized Langmuir (gL) isotherm. Considering vacant sites as an integral part of competitive multicomponent adsorption on a constant adsorbent surface area, the gL isotherm properly accounts for surface heterogeneity and loading, adsorbate composition, and temperature dependence. We show the spreading pressure dependence of adsorbate activity coefficient expression in the RAST framework can be generated from the gL isotherm. The procedure is illustrated with a spreading pressure dependent adsorption Nonrandom Furthermore, two-Liquid activity coefficient model, and the results are validated for ten binary mixed-gas adsorption equilibria systems including two highly nonideal azeotropic systems.

42 ENGINEERING↗

Continuous on-sun solar thermochemical hydrogen production via an isothermal redox cycle

Solar thermochemical hydrogen production from water is a path towards a carbon-free sustainable hydrogen economy. Here, isothermal on-sun hydrogen production is demonstrated using active iron aluminate (hercynite) particles contained in dual fluidized bed reactors. The two fluidized beds were held in a single cavity solar receiver that was heated with a 10 kW high flux solar furnace. During 8 h of on-sun testing, 5.3 L of H 2 were generated with an average productivity of 597 umol H 2 /g using an intermittent process with optimized redox cycle times. Redox cycling was performed isothermally and continuously with equivalent oxidation and reduction times producing 547 umol H2/g over two cycles. These results show excellent agreement with the H 2 production measured in an 800X scaled-down electrically heated laboratory stagnation flow reactor and surpass on-sun H 2 production of current benchmark materials. The effect of environmental variability on the incident solar radiation and hydrogen production is evaluated during on-sun testing. Finally, a discussion of the important factors for scalability of the process to commercial applications is provided, highlighting the importance of robust containment and active materials. This work links current materials research and development with commercial implementation in an on-sun process and demonstrates the viability of solar thermochemical hydrogen production that leverages continuous isothermal redox cycling.

08 HYDROGEN↗

A new adsorption model based on generalized van der Waals partition function for the description of all types of adsorption isotherms

A new adsorption model is proposed based on the Generalized van der Waals partition function by introducing the concept of attractive region, which integrates the effects of the adsorption sites of adsorbent and represents pore space where adsorbates concentrate. A theoretical expression for the chemical potential of adsorbates in the attractive region is derived and used to calculate the adsorbate density in each attractive region. The model can generate all the six types of isotherms classified by the International Union of Pure and Applied Chemistry (IUPAC) report including those with hysteresis and is easy to use. It is a generalized model that can be applied to various types of porous materials. With the fitted parameters, the model can predict the adsorption isotherms even for adsorbents with wide pore size distributions. It also well captures the isotherm-type transition as temperature changes and can estimate the hysteresis when capillary condensation exists.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature dependence of the sorption isotherms of cement-based materials: Heat of sorption and Clausius-Clapeyron formula

In the field of radioactive waste management the concrete structures are expected to undergo significant heating due to the waste thermal power and significant drying (in the French design, the temperature is not expected to exceed 80 deg. C). The durability assessment of such structures thus requires the knowledge of the evolution of the water vapour sorption properties versus temperature. The latter can be easily estimated using the Clausius-Clapeyron (CC) equation: the approach presented hereafter requires the knowledge of the isosteric heat of adsorption and one desorption isotherm (at ambient or any other temperature). Moreover, it is shown that using the CC equation and the desorption isotherms at two different temperatures, it is possible to estimate accurately the desorption isotherm at any other temperature.

36 MATERIALS SCIENCE↗

A review on nearly isothermal compression technology

Compressors can be described as the heart of a vapor compression refrigeration system, circulating the working fluid in the system. Significant benefits can be gained from improving its efficiency since energy consumption is responsible for almost the entire system's power input. An effort has been made to achieve isothermal compression through liquid refrigerant injection or inter-stage cooling in refrigeration systems. In recent years, much effort has been invested into isothermal compression technology for air compressors or compressed air energy storage systems with the rise of renewable energy. Here, this work has explored the advancements made in this area and categorized them to discuss the benefits, limitations, and tradeoffs. Evidently, increasing heat transfer area is a significant aid in improving heat transfer, resulting in better isothermal compression. However, liquid pistons open more avenues for this to be pursued, and therefore, are limited to air compression applications. In addition, water injection proved to be the most effective among the methods. Finally, there is a need for more experimental research on refrigeration applications and the field is still in its infancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CO 2 Sorption in Moisture Swing Anion Exchange Resins for Direct Air Capture: Experimental Isotherm Determination and Modeling

Moisture swing (MS) sorption is a promising direct air capture (DAC) technology to achieve negative CO 2 emissions and counter global warming. Here, in this study, MS CO 2 sorption in a model MS sorbent, IRA900, was investigated. IRA900 is a macroporous commercial strong-base anion exchange resin (AER) with quaternary ammonium functional groups. A rigorous CO 2 desorption process was developed to desorb all CO 2 from the sample and obtain CO 2 sorption isotherms as a function of relative humidity, CO 2 partial pressure, and temperature. CO 2 sorption increased with decreasing relative humidity, decreasing temperature, and increasing CO 2 partial pressure. Remarkably, the total CO 2 uptake from the sorption isotherms matched the ion exchange capacity (IEC) of the material, suggesting a stoichiometry of one CO 2 molecule reacting per active site. An isotherm model for CO 2 sorption starting with empty sorption sites (i.e., with the AER in the OH – form) described the experimental data well, supporting the hypothesis that the bicarbonate-loaded AER fully unloaded to the OH – state following rigorous CO 2 desorption. CO 2 sorption kinetics were studied, and carbon diffusion coefficients were estimated as a function of %RH and CO 2 partial pressure. Overall, this study provides a roadmap for the systematic evaluation of MS CO 2 DAC materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of moisture on adsorption isotherms and adsorption capacities of CO{sub 2} on coals

The effect of moisture on the adsorption isotherms and adsorption capacities of CO{sub 2} on Argonne Premium coals has been investigated. In some experiments a small hysteresis was observed between the adsorption and desorption isotherms. The hysteresis was absent or negligible for high-rank and as-received coals but was discernible for lower rank and dried coals. An equation that accounted for the volumetric changes when an adsorbate alters the structure of an adsorbent was employed to interpret the data. The best-fit solutions indicate that the coal volume decreases upon drying. The microscopic shrinkage estimated using helium expansion was greater than the shrinkage reported using the bed-height technique. The microscopic shrinkage was 5-10% for low-moisture medium and high-rank coals and up to 40% for low-rank coals having higher moisture contents. The CO{sub 2} swelling of coals during adsorption isotherm measurements was estimated to be about the same as the shrinkage that occurred during the moisture loss. The adsorption capacity, isosteric heat of adsorption, average pore size, and surface area of the as-received (moist) and dried Argonne coals were estimated after accounting for the volume changes. The isosteric heat of adsorption of CO{sub 2} was found to be between 23 and 25 kJ/mol for as-received coals and between 25 and 27 kJ/mol for dried coals, regardless of the rank. The degree of drying was shown to affect the adsorption capacity and the calculated surface area. For dried coals, the adsorption capacity showed the typical 'U-shape' dependence on rank whereas the as-received coals displayed a more linear dependence. A relationship is proposed to quantify the effect of moisture on the adsorption capacity. The mechanism of CO{sub 2} adsorption on moist coals and the implications of the lower adsorption capacity of wet coals to coal seam sequestration of CO{sub 2} are presented. 70 refs., 12 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Humidity scanning quartz crystal microbalance with dissipation monitoring setup for determination of sorption-desorption isotherms and rheological changes

A new method to determine water sorption-desorption isotherms with high resolution in the complete range of water activities (relative humidities) is presented. The method is based on quartz crystal microbalance with dissipation monitoring (QCM-D). The QCM-D is equipped with a humidity module in which the sample film is kept in air with controlled humidity. The experimental setup allows for continuous scanning of the relative humidity from either dry to humid conditions or vice versa. The amount of water sorbed or desorbed from the sample is determined from the resonance frequencies of the coated quartz sensor, via analysis of the overtone dependence. In addition, the method allows for characterization of hydration induced changes of the rheological properties from the dissipation data, which is closely connected to the viscoelasticity of the film. The accuracy of the humidity scanning setup is confirmed in control experiments. Sorption-desorption isotherms of pig gastric mucin and lysozyme, obtained by the new method, show good agreement with previous results. Finally, we show that the deposition technique used to coat the quartz sensor influences the QCM-D data and how this issue can be used to obtain further information on the effect of hydration. In particular, we demonstrate that spin-coating represents an attractive alternative to obtain sorption-desorption isotherms, while drop-coating provides additional information on changes of the rheological properties during hydration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isotherm measurements of high-pressure metal hydrides for hydrogen compressors

Hydrogen absorption and desorption isotherms have been measured for several metal hydride alloys identified as possible candidates in the high-pressure (i.e. >80 MPa) stage of a two-stage hydrogen compressor. The isotherms were obtained using two independent Sieverts volumetric test systems built specifically for measuring hydrogen absorption and desorption parameters from 0.10 to 100 MPa. The results obtained enabled us to identify the alloy Ti 0.8 Zr 0.2 Fe 1.6 V 0.4 as the most viable of the candidates investigated for use in the high-pressure stage of a prototype two-stage 80+ MPa compressor, as it produced the highest desorption pressures at moderate temperatures. Issues and challenges in determining reliable isotherms at pressures >50 MPa are also described.

08 HYDROGEN↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

Development of a HEX-Z Partially Homogenized Benchmark Model for the FFTF Isothermal Physics Measurements

A series of isothermal physics measurements were performed as part of an acceptance testing program for the Fast Flux Test Facility (FFTF). A HEX-Z partially-homogenized benchmark model of the FFTF fully-loaded core configuration was developed for evaluation of these measurements. Evaluated measurements include the critical eigenvalue of the fully-loaded core, two neutron spectra, 32 reactivity effects measurements, an isothermal temperature coefficient, and low-energy gamma and electron spectra. Dominant uncertainties in the critical configuration include the placement of radial shielding around the core, reactor core assembly pitch, composition of the stainless steel components, plutonium content in the fuel pellets, and boron content in the absorber pellets. Calculations of criticality, reactivity effects measurements, and the isothermal temperature coefficient using MCNP5 and ENDF/B-VII.0 cross sections with the benchmark model are in good agreement with the benchmark experiment measurements. There is only some correlation between calculated and measured spectral measurements; homogenization of many of the core components may have impacted computational assessment of these measurements. This benchmark evaluation has been added to the IRPhEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Enhancement of the Transcritical CO2 Cycle with a Near-Isothermal Liquid Piston Compression by an Ejector

This study investigates the use of an ejector in a transcritical CO2 cycle employing a near-isothermal liquid piston compressor, with the objective of mitigating refrigerant degassing in mineral oil. While the liquid piston compressor demonstrated high isothermal efficiency (˜90%), overall cycle performance was limited by CO2 degassing during chamber pressure fluctuations. A thermodynamic model was developed to compare baseline and ejector-assisted cycles, incorporating solubility correlations, entrainment ratio characteristics, and a degassing correction factor. Results indicate that the ejector increased suction pressure and reduced CO2–oil solubility variation, which improved refrigerant intake and reduced degassing losses. Despite these benefits, the ejector-assisted cycle showed a lower coefficient of performance (COP) than the baseline. Possible contributing factors include the limited marginal benefit of pressure reduction in a highly efficient isothermal compressor, reduced effectiveness of the separator due to the use of a suction-line heat exchanger in both cycles, and uncertainties in the solubility data under transient conditions. These findings suggest that degassing mitigation is essential for realizing the potential of liquid piston compression, but ejector integration alone is unlikely to enhance COP. Future work should focus on ejector optimization, improved oil–refrigerant management, introducing less-soluble working liquids, and experimental validation under realistic operating conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Isothermal Compressed Air Energy Storage to Support Renewable Energy Production

This project develops and demonstrates a megawatt (MW)-scale Energy Storage System that employs compressed air as the storage medium. An isothermal compressed air energy storage (ICAESTM) system rated for 1 MW or more will be demonstrated in a full-scale prototype unit. Breakthrough costeffectiveness will be achieved through the use of proprietary methods for isothermal gas cycling and staged gas expansion implemented using industrially mature, readily-available components. The ICAES approach uses an electrically driven mechanical system to raise air to high pressure for storage in low-cost pressure vessels, pipeline, or lined-rock cavern (LRC). This air is later expanded through the same mechanical system to drive the electric motor as a generator. The approach incorporates two key efficiency-enhancing innovations: (1) isothermal (constant temperature) gas cycling, which is achieved by mixing liquid with air (via spray or foam) to exchange heat with air undergoing compression or expansion; and (2) a novel, staged gas-expansion scheme that allows the drivetrain to operate at constant power while still allowing the stored gas to work over its entire pressure range. The ICAES system will be scalable, non-toxic, and cost-effective, making it suitable for firming renewables and for other grid applications.

25 ENERGY STORAGE↗