Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IRRADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

ORNL Post-irradiation Examination (LAMDA) Final Report on Characterization of Irradiated Grade 92 Ferritic-Martensitic Steels

Irradiation effects on ferritic-martensitic steel Grade 92 were investigated in this project. Samples from two heats of Grade 92, i.e., G92-2b and NF616, were selected, which were irradiated in the High Flux Isotope Reactor (HFIR) and the Advanced Test Reactor (ATR), respectively. Samples from two heats of ferriticmartensitic steel T91, irradiated in the ATR, were also selected as references for the Grade 92 samples. The selected G92-2b samples were irradiated to 0.5–14.7 displacements per atom (dpa) at two temperature regimes: 400–497 °C and 683–720°C. The selection of the high irradiation temperatures up to ~720°C is to test the performance at such upper bound temperatures, which would provide insights for the upper bound applicable temperature for Grade 92. The selected NF616 and T91 samples were irradiated to 3–8.2 dpa at 292–448°C. Except for T91 heat2 samples in 3-mm diameter discs, all the other selected samples are of type SS-J2 miniature tensile specimens. Two Nuclear Science User Facilities (NSUF), i.e., the Irradiated Materials Examination and Testing (IMET) hot cell facility and the Low Activation Materials Design and Analysis (LAMDA) facility, were used in the Post-Irradiation Examination (PIE) activities for the selected samples, which include: Tensile tests at room temperature (IMET); Fractography of the tensile fracture surfaces (LAMDA: scanning electron microscopy and energy; dispersive spectroscopy); Vickers hardness measurements (LAMDA); and Microstructural characterization (LAMDA: electron backscatter diffraction, focused-ion beam, and transmission electron microscopy).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STEM imaging of irradiation induced defects in Eurofer97 steel variants irradiated in the EUROfusion collaboration

Ten exploratory variants of Eurofer97 reduced activation ferritic martensitic (RAFM) steel were irradiated in HFIR to ~2.94 – 32.4 dpa, 300±30 °C as a part of the EUROfusion collaboration. The irradiations were performed in rabbit capsules. ES21-22 capsule were used for irradiating SS-J3 tensile samples while M4CVN bend bar samples were irradiated in ES31-35 capsules. The mechanical properties and multi-length scale characterization of the microstructures of these ten steels, designated as H, I, P, J, K, L, M, N, O, P and reference E, in the nonirradiated form was reported in "Mechanical properties and microstructure characterization of unirradiated Eurofer-97 steel variants for the EUROfusion project, ORNL/SPR-2018/882," while their irradiated properties and some microstructure analysis was reported in "Post-irradiation examination of Eurofer97 steel variants irradiated to 2.5 dpa, ~300 °C in HFIR for the EUROfusion program, ORNL/SPR-2020/1440." Here, additional microstructures using TEM/STEM and STEM-EDX of the irradiated steels is presented. Characterization was performed at the Low Activation Materials Development and Analysis (LAMDA) laboratory.

36 MATERIALS SCIENCE↗

Irradiation And Post-Irradiation Examination Plan For A709

The Advanced Materials and Manufacturing Technologies program is proposing a neutron irradiation campaign for alloy 709 (A709) plate product developed by the Advanced Reactor Technologies program. This irradiation campaign will support the deployment of A709 (included welded components) by providing data of engineering importance, such as data that can be used for establishing end-of-life design parameters and knockdown factors for irradiated materials properties versus properties for non-irradiated material. It will also advance the scientific understanding of A709 irradiation behaviors and material property evolution, which is vital for deploying A709 components into reactors with different neutron spectra, neutron fluxes, and irradiation temperatures as well as accelerating the deployment of new product forms and weld procedures. This document presents the plan for the neutron irradiation and post-irradiation examination for A709 and the scientific and technical basis for the plan.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Estimate of Changes in the Sun's Total Irradiance Caused by UV Irradiance Variations from 1874 to 1988

Enhanced emission from bright solar faculae is a source of significant variation in the sun's total irradiance. Relative to the emission from the quiet sun, facular emission is known to be considerably greater at UV wavelengths than at visible wavelengths. Determining the spectral dependence of facular emission is of interest for the physical insight this may provide to the origin of the sun's irradiance variations. It is also of interest because solar radiation at lambda less than 300 nm is almost totally absorbed in the Earth's atmosphere. Depending on the magnitude of the UV irradiance variations, changes in the sun's irradiance that penetrates to the Earth's surface may not be equivalent to total irradiance variations measured above the Earth's atmosphere. Using an empirical model of total irradiance variations which accounts separately for changes caused by bright faculae from those associated with dark sunspots, the contribution of UV irradiance variations to changes in the sun's total irradiance is estimated during solar cycles 12 to 21.

Lean, J.↗

A quantitative study of retention and release of deuterium and tritium during irradiation of y-LiAlO2 pellets

This study reports on the quantification of deuterium in ion-irradiated gamma-LiAlO2 pellets as a function of dose and temperature. The gamma-LiAlO2 pellets were sequentially irradiated with He+ and D2+ ions to the same fluences of 5E16, 1E17 and 2E17 He++D+/cm2 at 188 K. Additional irradiation was performed to 1E17, 2E17 and 4E17 He++D+/cm2 at 573 K. A set of the pellets irradiated at 188 K was shipped and stored at low temperatures from 80 to 132 K and characterized using time-of-flight secondary ion mass spectrometry at ~173 K. The deuterium depth profiles show a Gaussian-like distribution in the low-temperature pellets. The total deuterium retention is found to be directly proportional to the ion fluence. About 27 at.% of the implanted deuterium atoms were released from the pellet irradiated to 2E17 He++D+/cm2 at 188 K during storage at room temperature for ~1 month. Retention of the trapped or bound deuterium during ion irradiation at 573 K increases initially with ion fluence and tends to saturate at a high fluence. The amount of the released deuterium is observed to be quantitatively consistent with that of the released tritium from similar standard pellets during neutron irradiation at 573 K.

Deuterium retention and release, ion irradiation, ↗

Fission product distribution in irradiated safety-tested and as-irradiated AGR-2 TRISO particles

In this work, two tristructural isotropic (TRISO)-coated nuclear fuel particles were examined by electron probe microanalysis (EPMA) as part of the Advanced Gas Reactor program. The compacts’ average irradiation temperatures ranged from approximately 1260 to 1290 °C. One particle was examined in the as-irradiated condition, while the other was subject to 1600 °C post-irradiation safety testing. This study was undertaken to test a newly-developed EPMA technique to determine fission product masses in TRISO particles on a layer-by-layer basis, and to compare fission product distributions between an as-irradiated and safety-tested particle. Fission product concentration profiles were collected along two radii in each particle, with measured concentrations used to compute the fission product mass in each TRISO particle layer. These measured masses were then compared to those predicted from ORIGEN modeling calculations. Data collected from these measurements show that for these two particles, masses determined via EPMA were within ± 20% of the calculated masses for the rare-earth elements, Mo, Zr, Cs, I, and Pd. Elements that tend to be less homogeneously distributed include Sr, Te, Eu, Ag, and possibly Ba. Measured Ag masses differed by more than 40% from the calculated mass. Lanthanides other than Eu remain primarily within the fuel kernel in the as-irradiated particle but in the safety-tested particle these element masses were divided approximately equally between the kernel and kernel periphery. In both particles, the majority of Sr and Eu accumulated in the carbon-rich kernel periphery, although in the safety-tested particle, Sr and Eu accumulated farther from the fuel kernel than occurred with irradiation alone. A greater mass fraction of mobile elements, such as Cs and I accumulated in the buffer and IPyC in the safety-tested particle as compared to the as-irradiated particle. When fully developed and tested, this mass balance approach to TRISO particle analysis has the potential to provide insight into fuel behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation test and post irradiation examination of the high burnup HTGR fuel - 18491

In order to examine irradiation performance of the new Tri-structural Isotropic (TRISO) fuel for the High Temperature Gas-cooled Reactor (HTGR) at the burnup around 100 GWd/t, a capsule irradiation test was conducted by WWR-K research reactor in the Institute of Nuclear Physics (INP) of Kazakhstan. The irradiated TRISO fuel was designed by Japan Atomic Energy Agency (JAEA) and fabricated in basis of the HTTR fuel technology in Japan. The fractional release of fission gas from the fuel during the irradiation shows good agreement with the predicted one released from as-fabricated failed TRISO fuel. It was suggested that unexpected additional fuel failure would not occur during the irradiation up to 100 GWd/t. In addition, the post-irradiation examination (PIE) with the irradiated fuel is planned to qualify TRISO fuel integrity and upgrade HTGR fuel design for further burnup extension. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Revealing irradiation damage along with the entire damage range in ion-irradiated SiC/SiC composites using Raman spectroscopy

We present that incorporating Raman spectroscopy with transverse lift-out specimens is demonstrated to effectively characterize depth-dependent ion-irradiation damage in nuclear ceramics, such as SiC/SiC composites irradiated up to 1, 10 and 50 displacements per atom (dpa) at 350 °C using 10 MeV Au ions. Raman spectroscopy reveals irradiation-induced structural disorder saturation in both SiC-fiber and SiC-matrix at doses as low as 1 dpa, despite vastly different microstructures, inferred from similar longitudinal optical (LO) and transverse optical (TO) phonon peak shifts. Diamond (D) and graphitic (G) peaks from SiC-fibers disappear under irradiation, revealing irradiation-induced carbon packet loss. The irradiation-induced carbon packet loss is also verified by conducting TEM on same FIB foils used for Raman spectroscopy. In a previous study, the irradiation-induced SiC-fiber shrinkage is known to occur due to carbon packet loss in fibers.

36 MATERIALS SCIENCE↗

Irradiation Programs and Test Plans to Assess High-Fluence Irradiation Assisted Stress Corrosion Cracking Susceptibility.

. Irradiation assisted stress corrosion cracking (IASCC) is a known issue in current reactors. In a 60 year lifetime, reactor core internals may experience fluence levels up to 15 dpa for boiling water reactors (BWR) and 100+ dpa for pressurized water reactors (PWR). To support a safe operation of our fleet of reactors and maintain their economic viability it is important to be able to predict any evolution of material behaviors as reactors age and therefore fluence accumulated by reactor core component increases. For PWR reactors, the difficulty to predict high fluence behavior comes from the fact that there is not a consensus of the mechanism of IASCC and that little data is available. It is however possible to use the current state of knowledge on the evolution of irradiated microstructure and on the processes that influences IASCC to emit hypotheses. This report identifies several potential changes in microstructure and proposes to identify their potential impact of IASCC. The susceptibility of a component to high fluence IASCC is considered to not only depends on the intrinsic IASCC susceptibility of the component due to radiation effects on the material but to also be related to the evolution of the loading history of the material and interaction with the environment as total fluence increases. Single variation type experiments are proposed to be performed with materials that are representative of PWR condition and with materials irradiated in other conditions. To address the lack of IASCC propagation and initiation data generated with material irradiated in PWR condition, it is proposed to investigate the effect of spectrum and flux rate on the evolution of microstructure. A long term irradiation, aimed to generate a well-controlled irradiation history on a set on selected materials is also proposed for consideration. For BWR, the study of available data permitted to identify an area of concern for long term performance of component. The efficiency of hydrogen water chemistry mitigation technology may decrease as fluence increases for high-stress intensity factors. This report describes a program plan to determine the efficiency of hydrogen water chemistry as a function of the stress intensity factor applied and fluence. The use of existing, available, materials and the generation of additional materials via irradiation in a research reactor are considered.

36 MATERIALS SCIENCE↗

Development of a MOOSE-based crystal plasticity model with irradiation defect evolution for irradiation creep in 316

Irradiation creep and irradiation swelling are two of the lifetime limiting factors for structural materials in nuclear reactors. These mechanical effects are driven by irradiation defect evolution and the interaction of those defects with dislocations in the microstructure. We present here a coupled cluster dynamics – crystal plasticity approach to model irradiation swelling and creep behavior in 316 SS. The time-dependent evolution of irradiation defects is calculated with a cluster dynamics approach and passed to the crystal plasticity model to compute the dislocation evolution. We show the impact of the irradiation defect evolution on the stress state in the material, which drives inelastic deformation through dislocation motion. The inelastic deformation in the 316 SS is dependent on the dose rate, where the inelastic deformation driven by the early-stage irradiation defect evolution determines the mechanical behavior of the 316 SS.

316 Stainless Steels↗

Standardization of accelerator irradiation procedures for simulation of neutron induced damage in reactor structural materials

Self-ion irradiation is widely used as a method to simulate neutron damage in reactor structural materials. Accelerator-based simulation of void swelling, however, introduces a number of neutron-atypical features which require careful data extraction and in some cases introduction of innovative irradiation techniques to alleviate these issues. We briefly summarize three such atypical features: defect imbalance effects, pulsed beam effects, and carbon contamination. The latter issue has just been recently recognized as being relevant to simulation of void swelling and is discussed here in greater detail. It is shown that carbon ions are entrained in the ion beam by Coulomb force drag and accelerated toward the target surface. Beam-contaminant interactions are modeled using molecular dynamics simulation. By applying a multiple beam deflection technique, carbon and other contaminants can be effectively filtered out, as demonstrated in an irradiation of HT-9 alloy by 3.5 MeV Fe ions.

Environmental Molecular Sciences Laboratory↗

Multiscale characterization of irradiation behaviour of ion-irradiated SiC/SiC composites

Here, the irradiation tolerance of SiC/SiC composites was studied using 10 MeV Au ion irradiations at 350 °C, for surface doses between 1 and 50 displacements per atom (dpa). Atomic force microscopy and optical profilometry revealed irradiation-induced axial and radial shrinkage of SiC-fibers. At 50 dpa, net fiber shrinkage reached 2.8 ± 0.3%. We conclude that the primary cause of SiC-fiber shrinkage in SiC/SiC composites is the irradiation-induced loss of pre-existing carbon packets, which had occupied 2–3% fiber volume in unirradiated state. A compelling evidence of the carbon packet loss was revealed using a combination of state-of-art conventional transmission electron microscopy (TEM), high resolution TEM, energy-filtered TEM and electron energy loss spectroscopy. Additionally, the carbon packet volume fraction decreased with increasing dose, reaching near-complete loss after 50 dpa. Carbon packet loss was further confirmed using Raman spectroscopy where the carbon D and G peaks disappeared after irradiation. In contrast, irradiation-induced swelling of 1 ± 0.5% was observed in the matrix after 50 dpa. The study also shows that up to 50 dpa, the multilayer pyrolytic-carbon (PyC) interface in the composite is highly irradiation tolerant as it maintained its morphology, graphitic nature and showed no signs of amorphization. Additionally, Raman spectroscopy revealed a saturation of TEM invisible disorder at 1 dpa for both ultra-fine grains of the fiber and the larger SiC-matrix grains. However, TEM visible extended defect formation such as dislocation loops were only detected in the larger matrix grains, thereby revealing a potential role of grain size on defect accumulation in SiC.

36 MATERIALS SCIENCE↗

Characterization of high energy Xe ion irradiation effects in single crystal molybdenum with depth-resolved synchrotron microbeam diffraction

Microbeam X-ray diffraction experiments were conducted at beam line 34-ID of the Advanced Photon Source (APS) on fission fragment energy Xe heavy ion irradiated single crystal Molybdenum (Mo). Lattice strain measurements were obtained with a depth resolution of 0.7 mu m, which is critical in resolving the peculiar heterogeneity of irradiation damage associated with heavy ion irradiation. Q-space diffraction peak shift measurements were correlated with lattice strain induced by the ion irradiations. Transmission electron microscopy (TEM) characterizations were performed on the as-irradiated materials as well. Nanometer sized Xe bubble microstructures were observed via TEM. Molecular Dynamics (MD) simulations were performed to help interpret the lattice strain measurement results from the experiment. This study showed that the irradiation effects by fission fragment energy Xe ion irradiations can be collaboratively understood with the depth resolved X-ray diffraction and TEM measurements under the assistance of MD simulations. (c) 2015 Elsevier B.V. All rights reserved.

Yun, Di (ORCID:0000000297673214)↗

First elevated-temperature performance testing of coated particle fuel compacts from the AGR-1 irradiation experiment

In the AGR-1 irradiation experiment, 72 coated-particle fuel compacts were taken to a peak burnup of 19.5% fissions per initial metal atom with no in-pile failures. This paper discusses the first post-irradiation test of these mixed uranium oxide/uranium carbide fuel compacts at elevated temperature to examine the fuel performance under a simulated depressurized conduction cooldown event. A compact was heated for 400 h at 1600 degrees C. Release of 85Kr was monitored throughout the furnace test as an indicator of coating failure, while other fission product releases from the compact were periodically measured by capturing them on exchangeable, water-cooled deposition cups. No coating failure was detected during the furnace test, and this result was verified by subsequent electrolytic deconsolidation and acid leaching of the compact, which showed that all SiC layers were still intact. However, the deposition cups recovered significant quantities of silver, europium, and strontium. Based on comparison of calculated compact inventories at the end of irradiation versus analysis of these fission products released to the deposition cups and furnace internals, the minimum estimated fractional losses from the compact during the furnace test were 1.9 x 10-2 for silver, 1.4 x 10-3 for europium, and 1.1 x 10-5 for strontium. Other post-irradiation examination of AGR-1 compacts indicates that similar fractions of europium and silver may have already been released by the intact coated particles during irradiation, and it is therefore likely that the detected fission products released from the compact in this 1600 degrees C furnace test were from residual fission products in the matrix. Gamma analysis of coated particles deconsolidated from the compact after the heating test revealed that silver content within each particle varied considerably; a result that is probably not related to the furnace test, because it has also been observed in other as-irradiated AGR-1 compacts. X-ray imaging of selected particles was performed to examine the internal microstructure. This examination revealed variable irradiation performance of the coating layers, but sufficient statistical sampling is not yet available to identify any possible correlation to variation in individual particle fission product retention.

99 GENERAL AND MISCELLANEOUS↗

Design Studies for the Optimization of 238 Pu Production in NpO 2 Targets Irradiated at the High Flux Isotope Reactor

Efforts to reestablish a domestic 238 Pu production capability in support of National Aeronautics and Space Administration mission objectives are ongoing throughout the U.S. Department of Energy complex. The Plutonium-238 Supply Project (PSP) was initiated in response to a report published by the National Research Council in 2011 stating that “without a restart of 238 Pu production, it will be impossible for the United States, or any other country, to conduct certain important types of planetary missions after this decade.” The PSP is targeting a sustained, constant production rate of 1.5 kg/year of heat source PuO 2 for several years. Design and optimization studies of 237 Np-bearing targets are underway at Oak Ridge National Laboratory (ORNL). It is anticipated that targets will be irradiated in ORNL’s High Flux Isotope Reactor (HFIR) and in the Advanced Test Reactor (ATR) at Idaho National Laboratory. A variety of target materials, containments, arrangements, and irradiation histories have been analyzed, and the results indicate that a sufficient quantity of 238 Pu can be produced in HFIR and ATR to fulfill the PSP’s constant production rate target. This paper focuses on the design and optimization of new target configurations containing pellets that are (1) ~93% of the theoretical density of NpO 2 , (2) loaded into pins of cladding materials that can be handled as solid waste following postirradiation 238 Pu recovery operations, (3) irradiated in various vertical experiment facility (VXF) locations in the HFIR permanent beryllium reflector, and (4) rotated within and/or moved to another VXF location following each HFIR operational cycle to maximize 238Pu production and minimize peak heat generation rates.

07 ISOTOPE AND RADIATION SOURCES↗