Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress towards 28 GHz operations at the Facility for Rare Isotope Beams (FRIB)

This paper provides an overview on the design, operational parameters as well as recent development and recent performance, of the superconducting electron cyclotron resonance (ECR) ion source at the Facility for Rare Isotope Beams (FRIB). The ion source has been used in support of beam operations since the end of 2022 and was designed to operate at 28 GHz and be capable of delivering high intensity uranium beams to help support beam delivery of up to a final beam power of 400 kW. Currently operating at up to 20 kW many primary beams have been developed and routinely used with the superconducting ECR including uranium. Initially operated at 18 GHz, the ion source has now been coupled to a 28 GHz gyrotron and high intensity beams have been demonstrated ahead of the facility planned power ramp up. text with the article abstract. Replace this text with the article abstract.

Machicoane, G. A. [Michigan State University, East↗

Delivery of H - / H + Beams to Area A

We explore the relative merits of transporting the beam from the H + ion source and from the H - ion source to Area-A for low current applications. Transporting the H - beam to Area-A using the laser neutralization approach has some risk associated with it and will require some development. Alternative method of delivering H - beam to Area-A includes replacing LDBM00 bending magnet with kicker for sharing beam between Line D and modified Line A. Transporting the H + beam to Area-A will have significant impact on the operation the IPF facility and maintaining high pulse rate to IPF will require major modifications to the transition region of the accelerator and Drift Tube Linac.

43 PARTICLE ACCELERATORS↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Neutron generator based on intense lithium beam driver

We are proposing a compact neutron generator based on a Li beam driver. The proposed neutron generator comprises a laser ion source, a radio-frequency quadrupole linear accelerator (RFQ linac), a drift tube linac, and a target containing protons. In the generator, the lithium ion is used as a projectile instead of protons to utilize the kinematic focusing technique. The technique enables us to enhance the neutron flux without increasing the beam energy, which is important to develop a clean compact neutron generator. Moreover, the combination of a laser ion source and a RFQ linac with the direct plasma injection scheme will provide several tens of mA of a fully ionized lithium beam, which is much higher than that of conventional heavy ion sources comparable with proton drivers. Neutrons are generated by the nuclear reaction of the lithium ions and protons in the beam target. In this paper, we reported the current status of the development. For RFQ, we designed the RFQ rods to accelerate 40 mA of 7Li3+. We fabricated and installed the rods into a cavity, and, as a first test, accelerated 10 mA of C6+ successfully.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Study on ion current density of different species in laser produced plasma in a solenoid magnet

A solenoid magnetic field along the expanding laser-produced plasma is an essential technique of the laser ion source. The solenoid field can increase ion beam current at beam extraction point by a factor of 2 to over 100 by confining moving laser produced plasma in transverse direction. This technique is used everywhere from development lab to operational machine for user operation. However, the motion of ions in laser produced plasma is not fully understood. In this study, we experimentally investigated the motion of ions in a solenoid magnet (inner diameter 102 mm, coil length 1980 mm) for Al, Fe, and Ta targets. Using the following three conditions: full solenoid bore, a φ51 mm collimator on the solenoid axis, and a thin-wall φ51 mm tube at the bottom of the solenoid, we found that extracting ions at off-axis position (20~30 mm from the solenoid axis in this study) can enhance ion intensity by a factor of three or more. We continue to investigate ion motion in a solenoid field to develop better laser ion source design.

43 PARTICLE ACCELERATORS↗

Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Salt Effects on Li-Ion Exchange Kinetics of Na 2 Mg 2 P 3 O 9 N: Systematic In Situ Synchrotron Diffraction Studies

The kinetics and thermodynamics of solid-state ion exchange of Li+ into Na2Mg2P3O9N were investigated using in situ synchrotron X-ray diffraction methods for a series of Li-containing salts, allowing systematic trends with general applicability to ion exchange reactions to be elucidated. The collection of data for a wide range of reaction conditions was enabled through the use of a novel multiwell sample environment which leverages the ability of the synchrotron beamline to rapidly (similar to 1 s) collect high-quality data suitable for monitoring reaction progress. From these data, it was possible to resolve the influence of salt choice and salt concentration on the ion exchange reaction kinetics. Furthermore, by carrying out experiments at different temperatures, initial estimates of activation energies were obtained. It was generally found that the ion exchange reaction kinetics strongly depended on the salt chosen as the ion source rather than being primarily determined by the ion mobility of the ceramic.

Cosby, Monty R.↗

High Brightness High Duty Factor Negative Ion Beam Injector [Slides]

The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.

43 PARTICLE ACCELERATORS↗

Diagnostics for multiple frequency heating and investigation of underlying processes

The development of new facilities routinely challenges ion source designers to build and operate sources that can achieve ever higher beam intensities and energies. As shown in this work, electron cyclotron resonance ion sources have proven to be extremely capable in meeting these challenges through the production of intense beams of medium and high-charge state ions. As performance boundaries are pushed, source stability becomes an issue as does the technology required to meet the challenge. Multiple frequency heating, the simultaneous use of two or more plasma heating frequencies, is a powerful tool in meeting the simultaneous need of intensity and stability. Relatively straightforward to utilize, the technique has been employed at numerous facilities to increase beam current and achievable charge state while also stabilizing the plasma. Its application has expanded the operational boundaries of existing and next generation sources, demonstrating that these devices have not yet achieved their full operational potential. To better understand the underlying physics, the diagnostics used to probe the source operational boundaries and the plasma properties have become increasingly sophisticated. In concert with detailed modeling, they are beginning to provide insight into the heating mechanism and, with that, the prospect of future advances.

47 OTHER INSTRUMENTATION↗

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Electromagnetic Radioisotope Separator for Methods Development, Testing, and Training

The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.

07 ISOTOPE AND RADIATION SOURCES↗

Impurity transport in PISCES-RF

Linear plasma devices (LPD) utilizing a helicon plasma source, a high density light ion source, can generate impurities due to progressive erosion of the radio frequency (RF) transmission window caused by rectified sheath voltage. These source-born impurities can entrain and be transported by the plasma toward a target, affecting plasma-material interaction studies. Earlier work on material testing in Prototype-Materials Plasma Exposure eXperiment at ORNL revealed significant source impurity deposition on downstream targets. However, using a similar RF source, no target impurity deposition is observed in Plasma Interaction Surface Component Experimental Station (PISCES)-RF despite evidence of RF window erosion in the source region, thereby motivating the present work. Experimentally, using various magnetic field configurations upstream of the PISCES-RF plasma source and seeding titanium (Ti) impurities at various axial locations, impurity transport and deposition along the machine axis were investigated. It was found that Ti deposition was localized to the side of the plasma source where the Ti impurity was seeded. In contrast, aluminum (Al) deposition, originating from the sputtering of the helicon window, occurred predominantly upstream of the plasma source, suggesting an asymmetry in the axial transport of eroded RF window material. These observations suggest a stagnation of the parallel plasma flow immediately downstream of the plasma source, with impurity ions remaining unmagnetized near the source upstream. Al deposition in magnetic field-free regions in PISCES-RF indicates that sputtered Al impurities likely remained neutral due to their large ionization mean-free path under PISCES-RF conditions. Plasma modeling and simulation supported this, indicating that Al-neutrals transport toward the helicon source upstream for low electron density cases. It was found that the Larmor radius of the Al ions was greater than the plasma radius towards the source upstream and remained weakly magnetized in PISCES-RF, meaning that plasma source-born impurities are not efficiently entrained in the plasma flow. These findings provide critical insights into impurity transport in helicon plasma-based LPDs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the DIII-D co/counter off-axis neutral beam injected power and ability to balance injected torque

DIII-D has undergone a major upgrade and successfully injected high power off-axis neutral beams (~4 MW) in both co-current and counter-current directions. This capability of high power co/counter steerable off-axis neutral beams on a major tokamak opens a unique parameter space of broad pressure and current profiles for high beta steady-state advanced tokamak (AT) scenarios, while retaining the ability to balance the injected torque for low rotation studies. This co/counter off-axis neutral beam capability is being used to validate physics-based energetic particle and thermal transport models for designing next-step facilities based on the steady-state AT approach. This paper reports on the critical evaluation of the transmitted power and energetic ion population produced by this heating and current drive system, which is assessed through visible imaging, neutron measurements and rotation profile measurements at balanced torque. Minimal losses of neutral beam power have been achieved by optimizing the strongly focused ion sources required to pass through the aperture. Tilting of the ion source has been guided by fast visible imaging and resulted in neutral beam injection along the design centerline with empirical characterization of each beam's divergence derived from the imaging data and used in the NUBEAM description of the beam injection. Through exclusive power injection of each neutral beam into MHD quiescent plasmas across a range of neutral beam voltage, perveance and plasma current we conclude that a modest reduction (~10%–15%) of transmitted power compared to on-axis, standard focus has been incurred. We report corrections that more accurately represent the injected power. Good ability to balance the neutral beam torque has been demonstrated by injecting the new off-axis counter injecting beam against the existing off-axis co-injected beam in 2.0 T, 1.0 MA, MHD quiescent L-mode plasmas. Furthermore, the torque balance studies verify the ability to operate with balanced injection, which is critical for achieving low torque and low rotation operation for physics studies and in ITER demonstration discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Magnetized Electron Source For Ion Beam Cooling

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility would augment the existing ion/proton facility with an electron accelerator. Thomas Jefferson National Accelerator Facility (JLab) plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require cooling of the ion beams in order to reach the luminosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunched-beam cooling, while JLab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions, such as flat beam klystrons and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high-performance injectors for electron cooling is limited, the market for high-frequency RF sources and compact X-ray systems is con- siderable. Thus, the design methodologies developed in this project have a wide range of applicability. In Phase I of this SBIR project, Xelera Research LLC performed simulations and calcu- lations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and tech- niques that are applicable not only to specific machine designs but to other applications requiring magnetized injectors as well. In this Phase II SBIR project, Xelera Research LLC, in collaboration with a team at JLab, designed, built, and tested a thermionic elec- tron source for driving a magnetized electron cooler in a future electron-ion collider project. This device was delivered to JLab in July 2019 and achieved first beam in December 2019.

43 PARTICLE ACCELERATORS↗

Growth of Highly Transparent Amorphous Carbon Films Using Beam Plasma Source

A single beam plasma source was used to deposit hydrogenated amorphous carbon (a-C:H) coatings at room temperature. Using methane source gas, a-C:H coatings were deposited at different radio frequency (RF) power to fabricate transparent and durable coatings. The film deposition rate was almost linearly proportional to the ion source power. Hydrogenated amorphous carbon films of ~100 nm thickness appeared to be highly transparent from UV to the infrared range with a transmittance of ~90% and optical bandgap of ~3.7 eV. The coatings also possess desirable mechanical properties with Young’s modulus of ~78 GPa and density of ~1.9 g/cm3. The combined material properties of high transmittance and high durability make the ion-source-deposited a-C:H coatings attractive for many applications.

36 MATERIALS SCIENCE↗

High-Resolution Laser Spectroscopy on the Hyperfine Structure of 255Fm (𝑍=100)

We report on high-resolution laser spectroscopy of 255Fm (𝑇1/2=20 h), one of the heaviest nuclides available from reactor breeding. The hyperfine structures in two different atomic ground-state transitions at 398.4 nm and 398.2 nm were probed by in-source laser spectroscopy at the RISIKO mass separator in Mainz, using the perpendicularly illuminated laser ion source and trap (PI-LIST) high-resolution ion source. Experimental results were combined with hyperfine fields from various atomic ab initio calculations, in particular using multiconfiguration Dirac-Hartree-Fock theory, as implemented in grasp18. In this manner, the nuclear magnetic dipole and electric quadrupole moments were derived to be 𝜇=−0.75⁢(5) 𝜇N and 𝑄s=+5.84⁢(13) eb, respectively. The magnetic moment indicates occupation of the 𝜈⁢7/2⁢[613] Nilsson orbital, while the large quadrupole moment confirms strong, stable prolate deformation consistent with systematics in the heavy actinides. Comparisons with available expectation values from nuclear theory show good agreement, providing a stringent benchmark for the used theoretical models. These results revise earlier data and establish 255Fm as a reference isotope for future high-resolution studies.

Ezold, Julie [ORNL] (ORCID:0000000250550022)↗