Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IODINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

In situ reductive dissolution to remove Iodine-129 from aquifer sediments

The use of an aqueous reductant (Na-dithionite) with pH buffer (K-carbonate, pH 12) was evaluated in this laboratory study as a potential remedial approach for removing Fe oxide associated iodine and enhancing pump-and-treat extraction from iodine-contaminated sediments in the unconfined aquifer in the 200 West Area of the Hanford site. X-ray fluorescence data of untreated sediment indicated that iodine was largely associated with Fe (i.e., incorporated into Fe oxides), however, XANES data was inconclusive as to valence state. During groundwater leaching, aqueous and adsorbed iodine was quickly released, then additional iodine was slowly released potentially from dissolution of one or more surface phases. The Na-dithionite treatment removed greater iodine mass (2.9x) at a faster rate (1 to 4 orders of magnitude) compared to leaching with groundwater alone. Iron extractions for untreated and treated sediments showed a decrease in Fe(III)-oxides, which likely released iodine to aqueous solution. Solid phase inorganic carbon and aqueous Ca and Mg analysis further confirmed that significant calcite dissolution did not occur in these experiments meaning these phases did not release significant iodine. Although it was expected that, after treatment, 127 I concentrations would eventually be lower than untreated sediments, leaching experiments showed continued, elevated iodine concentrations for treated samples over 750 hours. Stop flow events during 1-D column leaching suggested that some iodide precipitated within the first few pore volumes. In the survey of metals during leaching, some silver was detected which could have been solubilized by the elevated pH of initial Na-dithionite injection. Then, silver (or other metals) could have subsequently precipitated with iodide during the initial stop flow event forming a slowly dissolving source. Although significantly greater iodine is removed with treatment, the long-term leaching needs to be investigated further as it may limit dithionite treatment at the field scale.

54 ENVIRONMENTAL SCIENCES↗

Adsorption of Iodine and Tritium from UNF Reprocessing Off-Gas Streams

The need to control emissions of the gaseous radionuclides to the air during nuclear fuel recycling is widely recognized. Gaseous radionuclides can partition to off-gas streams emanating from the various individual processes used in the recycle plant, such as from the mechanical head end (shear), tritium pretreatment, fuel dissolver, vessel vents, cell ventilation, and conversion operations. In traditional recycle plants, the bulk of the four primary volatile fission products (i.e., {sup 3}H, {sup 14}C, {sup 85}Kr, and {sup 129}I) is released in the head-end processes, for example, the dissolution process. The usual off-gas treatment sequence of operations targets removal of tritium (as {sup 3}HHO), iodine, carbon (as {sup 14}CO{sub 2}), and the noble gases, in that order. Water and iodine are captured first because the other species are relatively unimpeded by the sorbents used for water and iodine, so they flow downstream to additional treatment processes. Water and iodine do react with one another, and many techniques used to collect one of these species also collect some fraction of the other. It is quite desirable to sequester the iodine and water separately because the tritiated water may be disposed of as a low level waste. If not cleanly separated, contamination of the low-level waste by iodine may elevate its classification to high-level waste and result in greater costs for disposal. The proposed sorption sequence was tested in the laboratory. Use of a second column of AgZ permits the detection of breakthrough from the primary AgZ column while protecting the downstream 3AMS column from collecting iodine. (This arrangement is equivalent to enabling intra-column sampling of the primary column.) Neutron activation analysis of the 3AMS revealed that iodine was below, or at, the level of detection. The results successfully demonstrated that iodine can be sequestered in the AgZ while the water is collected free of iodine in the 3AMS column. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soil Iodine Determination in Deccan Syneclise, India: Implications for Near Surface Geochemical Hydrocarbon Prospecting

The association of iodine with organic matter in sedimentary basins is well documented. High iodine concentration in soils overlying oil and gas fields and areas with hydrocarbon microseepage has been observed and used as a geochemical exploratory tool for hydrocarbons in a few studies. In this study, we measure iodine concentration in soil samples collected from parts of Deccan Syneclise in the west central India to investigate its potential application as a geochemical indicator for hydrocarbons. The Deccan Syneclise consists of rifted depositional sites with Gondwana-Mesozoic sediments up to 3.5 km concealed under the Deccan Traps and is considered prospective for hydrocarbons. The concentration of iodine in soil samples is determined using ICP-MS and the values range between 1.1 and 19.3 ppm. High iodine values are characteristic of the northern part of the sampled region. The total organic carbon (TOC) content of the soil samples range between 0.1 and 1.3%. The TOC correlates poorly with the soil iodine (r{sup 2} < 1), indicating a lack of association of iodine with the surficial organic matter and the possibility of interaction between the seeping hydrocarbons and soil iodine. Further, the distribution pattern of iodine compares well with two surface geochemical indicators: the adsorbed light gaseous hydrocarbons (methane through butane) and the propane-oxidizing bacterial populations in the soil. The integration of geochemical observations show the occurrence of elevated values in the northern part of the study area, which is also coincident with the presence of exposed dyke swarms that probably serve as conduits for hydrocarbon microseepage. The corroboration of iodine with existing geological, geophysical, and geochemical data suggests its efficacy as one of the potential tool in surface geochemical exploration of hydrocarbons. Our study supports Deccan Syneclise to be promising in terms of its hydrocarbon prospects.

58 GEOSCIENCES↗

Factors associated with serum thyroglobulin in a Ukrainian cohort exposed to iodine-131 from the accident at the Chernobyl Nuclear Plant

Background: Serum thyroglobulin (Tg) is associated with the presence of thyroid disease and has been proposed as a biomarker of iodine status. Few studies have examined factors related to serum Tg in populations environmentally exposed to ionizing radiation and living in regions with endemic mild-to-moderate iodine deficiency. Methods: We screened 10,430 individuals who were living in Ukraine and under 18 years of age at the time of the 1986 Chernobyl Nuclear Power Plant accident for thyroid disease from 2001 to 2003. We estimated the percent change (PC) in serum Tg associated with demographic factors, iodine-131 thyroid dose, and indicators of thyroid structure and function using linear regression. We also examined these relationships for individuals with and without indications of thyroid abnormality. Results: Mean and median serum Tg levels were higher among participants with abnormal thyroid structure/function. Percent change in serum Tg increased among females, smokers and with older age (p-values<0.001), and Tg increased with increasing thyroid volume, and serum thyrotropin (p-values for trend<0.001). We found no evidence of significant associations between iodine-131 thyroid dose and Tg. Serum Tg levels were inversely associated with iodized salt intake (PC=−7.90, 95% confidence interval: −12.08, −3.52), and over the range of urinary iodine concentration, the odds of having elevated serum Tg showed a U-shaped curve with elevated Tg at low and high urinary iodine concentrations. Conclusion: Serum Tg may be a useful indicator of population iodine status and a non-specific biomarker of structural and functional thyroid abnormalities in epidemiological studies. - Highlights: • We evaluated serum thyroglobulin (Tg) in 10,430 irradiated, mostly iodine deficient Ukrainians. • Tg levels were higher among subjects with abnormal thyroid structure/function. • Increased Tg was associated with increasing age, thyroid volume and thyrotropin levels. • The odds of elevated Tg showed a U-shaped curve over categories of dietary iodine status. • Serum Tg is a useful indicator of population iodine status and thyroid abnormalities.

54 ENVIRONMENTAL SCIENCES↗

Estimation of iodine nutrition and thyroid function status in late-gestation pregnant women in the United States: Development and application of a population-based pregnancy model

Previously, a deterministic biologically-based dose-response (BBDR) pregnancy model was developed to evaluate moderate thyroid axis disturbances with and without thyroid-active chemical exposure in a near-term pregnant woman and fetus. In the current study, the existing BBDR model was adapted to include a wider functional range of iodine nutrition, including more severe iodine deficiency conditions, and to incorporate empirically the effects of homeostatic mechanisms. The extended model was further developed into a population-based model and was constructed using a Monte Carlo-based probabilistic framework. In order to characterize total (T4) and free (fT4) thyroxine levels for a given iodine status at the population-level, the distribution of iodine intake for late-gestation pregnant women in the U.S was reconstructed using various reverse dosimetry methods and available biomonitoring data. The range of median (mean) iodine intake values resulting from three different methods of reverse dosimetry tested was 196.5–219.9 μg of iodine/day (228.2–392.9 μg of iodine/day). There was minimal variation in model-predicted maternal serum T4 and ft4 thyroxine levels from use of the three reconstructed distributions of iodine intake; the range of geometric mean for T4 and fT4, was 138–151.7 nmol/L and 7.9–8.7 pmol/L, respectively. The average value of the ratio of the 97.5th percentile to the 2.5th percentile equaled 3.1 and agreed well with similar estimates from recent observations in third-trimester pregnant women in the U.S. In addition, the reconstructed distributions of iodine intake allowed us to estimate nutrient inadequacy for late-gestation pregnant women in the U.S. via the probability approach. The prevalence of iodine inadequacy for third-trimester pregnant women in the U.S. was estimated to be between 21% and 44%. Taken together, the current work provides an improved tool for evaluating iodine nutritional status and the corresponding thyroid function status in pregnant women in the U.S. This model enables future assessments of the relevant risk of thyroid hormone level perturbations due to exposure to thyroid-active chemicals at the population-level. - Highlights: • A population-based thyroid function model for pregnant women was developed. • The model was used specifically study the late-gestation pregnant women in the U.S. • The prevalence of iodine inadequacy was estimated in the sub-population studied. • Developed model well predicts trimester-specific thyroid hormone reference ranges. • The model can be further used to study thyroid perturbations at a population level.

60 APPLIED LIFE SCIENCES↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗

Complete Iodine Loading of NO-Aged Ag 0 -Functionalized Silica Aerogel (Milestone Report)

In off-gas treatment systems within a nuclear fuel reprocessing plant, capture materials will be exposed to a gas stream for extended periods during their lifetime. This gas stream may be at elevated temperature and could contain water, NO x gas, or a variety of other constituents. For this reason, it is important to understand the effects of long-term exposure, or aging, on proposed capture materials. One material under consideration for iodine sequestration is silver-functionalized silica aerogel (Ag 0 -aerogel). The aim of this study was to determine the effect of extended exposure at 150°C to an air stream containing NO on the iodine capture capacity of Ag 0 -aerogel. Ag 0 -aerogel was provided by the Pacific Northwest National Laboratory (PNNL), which manufactures the material at a lab scale. Prior to aging, the material has an iodine loading capacity of approximately 290 mg I/g Ag 0 -aerogel. Previous studies have aged the material in a dry air stream or in a moist air stream for up to 6 months. Both tests resulted in a 22% loss in iodine capacity. Aging the material in a static 2% NO 2 environment for up to 2 months results in a 15% loss of iodine capacity.3 In this study, exposure of Ag 0 -aerogel to 1% NO at 150°C for 2 months produced a loss of 43% in iodine loading capacity. This is largest loss observed for aerogel aging studies to date. The performance of Ag 0 -aerogel in this study was compared to the performance of reduced silver mordenite (Ag 0 Z) in similar studies. Ag 0 Z is a zeolite mineral considered to be the current standard technology for iodine removal from off-gas streams of a potential US used fuel processing plant. In an aging study exposing Ag 0 Z to 1% NO for 2 months, an iodine capacity loss of over 80% was observed. This corresponds to a silver utilization of 13.5% for 2 month NO-aged Ag 0 Z, compared to 57% silver utilization for 2 month NO-aged aerogel. While iodine loading capacity and silver utilization are critical parameters in evaluating these materials, other properties must also be considered when selecting the appropriate material (e.g., relative material densities and potential waste form production technology). The resistance of Ag 0 -aerogel to NO is promising, and investigations of this material for use in iodine capture should continue to be pursued.

36 MATERIALS SCIENCE↗

Dynamics of iodine geminate recombination in supercritical xenon solvent: Caging effect

Understanding the dynamics of chemical reactions in solutions is vital, as their rates and kinetics are significantly affected by the solvent environment. Supercritical solvents offer extensive applications in chemical reactions by enabling the manipulation of the solution environment. Here, in this study, we investigate the geminate recombination of iodine in a supercritical xenon solvent by using ReaxFF-based molecular dynamics simulations. Our findings reveal that the highest iodine recombination rate occurs near supercritical conditions, while lower-pressure conditions lead to reduced collision rates and unstable recombination, and higher-pressure conditions hinder iodine diffusion, resulting in a lower recombination rate. Our analysis shows that the xenon local density at the time of recombination is at least 2.5 times higher than the global density, confirming the presence of xenon clusters surrounding the Iodine atoms. This observation is further supported by coordination number analysis, which confirms an elevated xenon local density during recombination. In addition, the correlation between the total energy of xenon atoms within a cluster and recombined iodine atoms underscores the kinetic energy transfer process, validating the occurrence of geminate recombination. The excess kinetic energy from the recombining iodine atoms is transferred to the surrounding xenon atoms. Our examination of geminate recombination demonstrates that iodine atoms confined within xenon clusters—whether through manual insertion of atoms or the fast dissociation of an iodine molecule within xenon clusters—are more likely to recombine as primary geminate recombination. However, extending the iodine molecule dissociation time allows iodine atoms to diffuse out of the cluster, and the recombination to shift toward secondary geminate recombination.

Cage effect↗

Iodine Hall Thruster Propellant Feed System for a CubeSat

There has been significant work recently in the development of iodine-fed Hall thrusters for in-space propulsion applications.1 The use of iodine as a propellant provides many advantages over present xenon-gas-fed Hall thruster systems. Iodine is a solid at ambient temperature (no pressurization required) and has no special handling requirements, making it safe for secondary flight opportunities. It has exceptionally high ρI sp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing system level advantages over mid-term high power electric propulsion options. Iodine provides thrust and efficiency that are comparable to xenonfed Hall thrusters while operating in the same discharge current and voltage regime, making it possible to leverage the development of flight-qualified xenon Hall thruster power processing units for the iodine application. Work at MSFC is presently aimed at designing, integrating, and demonstrating a flight-like iodine feed system suitable for the Hall thruster application. This effort represents a significant advancement in state-of-the-art. Though Iodine thrusters have demonstrated high performance with mission enabling potential, a flight-like feed system has never been demonstrated and iodine compatible components do not yet exist. Presented in this paper is the end-to-end integrated feed system demonstration. The system includes a propellant tank with active feedback-control heating, fill and drain interfaces, latching and proportional flow control valves (PFCV), flow resistors, and flight-like CubeSat power and control electronics. Hardware is integrated into a CubeSat-sized structure, calibrated and tested under vacuum conditions, and operated under under hot-fire conditions using a Busek BHT-200 thruster designed for iodine. Performance of the system is evaluated thorugh accurate measurement of thrust and a calibrated of mass flow rate measurement, which is a function of reservoir temperature/pressure, the flow resistors, and the setting of the PFCV. The calibration is performed using independent flow control monitoring techniques, providing an in situ measure of the flowrate as a function of controllable parameters. The reservoir temperature controls the iodine sublimation rate, providing propellant to ths thruster by pressurizing the propellant feed system to approx.1-2 psi. Control of the temperature and the PFCV are used to maintain reservoir pressure and keep the thruster discharge current constant.

Polzin, Kurt A.↗

Iodine Satellite

The Iodine Satellite (iSat) spacecraft will be the first CubeSat to demonstrate high change in velocity from a primary propulsion system by using Hall thruster technology and iodine as a propellant. The mission will demonstrate CubeSat maneuverability, including plane change, altitude change and change in its closest approach to Earth to ensure atmospheric reentry in less than 90 days. The mission is planned for launch in fall 2017. Hall thruster technology is a type of electric propulsion. Electric propulsion uses electricity, typically from solar panels, to accelerate the propellant. Electric propulsion can accelerate propellant to 10 times higher velocities than traditional chemical propulsion systems, which significantly increases fuel efficiency. To enable the success of the propulsion subsystem, iSat will also demonstrate power management and thermal control capabilities well beyond the current state-of-the-art for spacecraft of its size. This technology is a viable primary propulsion system that can be used on small satellites ranging from about 22 pounds (10 kilograms) to more than 1,000 pounds (450 kilograms). iSat's fuel efficiency is ten times greater and its propulsion per volume is 100 times greater than current cold-gas systems and three times better than the same system operating on xenon. iSat's iodine propulsion system consists of a 200 watt (W) Hall thruster, a cathode, a tank to store solid iodine, a power processing unit (PPU) and the feed system to supply the iodine. This propulsion system is based on a 200 W Hall thruster developed by Busek Co. Inc., which was previously flown using xenon as the propellant. Several improvements have been made to the original system to include a compact PPU, targeting greater than 80 percent reduction in mass and volume of conventional PPU designs. The cathode technology is planned to enable heaterless cathode conditioning, significantly increasing total system efficiency. The feed system has been designed to include iodine compatible control valves with internal heaters and temperature sensors to coincide with the iodine-compatible thruster. A key advantage to using iodine as a propellant is that it may be stored in the tank as an unpressurized solid on the ground and before flight operations. During operations, the tank is heated to vaporize the propellant. Iodine vapor is then routed through custom flow control valves to control mass flow to the thruster and cathode assembly. The thruster then ionizes the vapor and accelerates it via magnetic and electrostatic fields, resulting in high specific impulse, characteristic of a highly efficient propulsion system. The iSat spacecraft is a 12-unit (12U) CubeSat with dimensions of about 8 inches x 8 inches x 12 inches (20 centimeters x 20 centimeters x 30 centimeters). The spacecraft frame will be constructed from aluminum with a finish to prevent iodine-driven corrosion. The iSat spacecraft includes full three-axis control and will leverage heat generated by spacecraft components and radiators for a passive thermal control system. After the CubeSat has successfully detached from its launch vehicle, it will deploy its solar panels, correct for tip-off and maintain attitude control before ground contact. An initial check-out period of two weeks is planned for testing all subsystems. The spacecraft will charge the power system while in sunlight, using momentum wheels and magnetic torque rods to rotate the vehicle to the required attitude.

iSat↗

Iodine Satellite

This project is a collaborative effort to mature an iodine propulsion system while reducing risk and increasing fidelity of a technology demonstration mission concept. 1 The FY 2014 tasks include investments leveraged throughout NASA, from multiple mission directorates, as a partnership with NASA Glenn Research Center (GRC), a NASA Marshall Space Flight Center (MSFC) Technology Investment Project, and an Air Force partnership. Propulsion technology is often a critical enabling technology for space missions. NASA is investing in technologies to enable high value missions with very small and low-cost spacecraft, even CubeSats. However, these small spacecraft currently lack any appreciable propulsion capability. CubeSats are typically deployed and drift without any ability to transfer to higher value orbits, perform orbit maintenance, or deorbit. However, the iodine Hall system can allow the spacecraft to transfer into a higher value science orbit. The iodine satellite (iSAT) will be able to achieve a (Delta)V of >500 m/s with <1 kg of solid iodine propellant, which can be stored in an unpressurized benign state prior to launch. The iSAT propulsion system consists of the 200 W Hall thruster, solid iodine propellant tank, a power processing unit, and the necessary valves and tubing to route the iodine vapor. The propulsion system is led by GRC, with critical hardware provided by the Busek Co. The propellant tank begins with solid iodine unpressurized on the ground and in-flight before operations, which is then heated via tank heaters to a temperature at which solid iodine sublimates to iodine vapor. The vapor is then routed through tubing and custom valves to control mass flow to the thruster and cathode assembly. 2 The thruster then ionizes the vapor and accelerates it via magnetic and electrostatic fields, resulting in thrust with a specific impulse >1,300 s. The iSAT spacecraft, illustrated in figure 1, is currently a 12U CubeSat. The spacecraft chassis will be constructed from aluminum with a finish to prevent iodine-driven corrosion. The iSAT spacecraft includes full three-axis control using wheels, magnetic torque rods, inertial management unit, and a suite of sensors and optics. The spacecraft will leverage heat generated by spacecraft components and radiators for a passive thermal control system.

Dankanich, John↗

Engineering Model Propellant Feed System Development for an Iodine Hall Thruster Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cu cm and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high (Delta)v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (< 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp −6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. In the present paper, we describe the design and testing of the engineering model propellant feed system for iSAT (see Fig. 1). The feed system is based around an iodine propellant reservoir and two proportional control valves (PFCVs) that meter the iodine flow to the cathode and anode. The flow is split upstream of the PFCVs to both components can be fed from a common reservoir. Testing of the reservoir is reported to demonstrate that the design is capable of delivering the required propellant flow rates to operate the thruster. The tubing and reservoir are fabricated from hastelloy to resist corrosion by the heated gaseous iodine propellant. The reservoir, tubing, and PFCVs are heated to ensure the sublimed propellant will not re-deposit within the feed system. Heating is accomplished through a number of individual zones to control the overall power expended on heating the system and insulation is employed to minimize the amount of power used to heat the system prior to thruster operation.

Polzin, Kurt A.↗

Demonstration of a 600 Watt Hybrid Iodine-Xenon Electric Propulsion System

This paper reviews recent iodine compatible electric propulsion technologies evaluated at the NASA Glenn Research Center. The work culminated in a 1,174-hour hybrid iodine-xenon propulsion system durability demonstration (iodine fed thruster with xenon fed cathode). The test demonstrated that (i) a Hall-effect thruster operates with nearly identical performance whether employing iodine or xenon propellant, (ii) careful selection of propulsion system materials and coatings can result in durable iodine-compatible hardware, and (iii) implementation of appropriate facility improvements and procedures can limit negative impacts of iodine on test hardware and ground support equipment. The work was motivated by advancements in capability of very dense small-spacecraft (<500 kg), but spacecraft still lacking very dense in-space propulsion to provide the large delta-v capabilities (3 to 10 km/s) required for many high-value NASA exploration and science missions. Volume limitations of small-spacecraft not only require dense propulsion systems, but more so dense propellants. NASA identifies xenon and iodine as having both favorable storage densities and propulsive properties to enable many NASA small-spacecraft mission scenarios. While xenon is inert and well-proven in spaceflight applications, iodine has triple the storage density of xenon and stores at low pressures, permitting use of conformal tank designs. Unlike xenon, iodine does raise concerns related to its reactivity with most materials, potential spacecraft-propellant interactions, impact on ground test facilities, and challenges to acceptance test iodine propulsion systems prior to flight. This work begins to address these challenges. This work was conducted under the Advanced In-Space Propulsion (AISP) project funded through the Game Changing Development (GCD) program within NASA's Science Technology Mission Directorate (STMD).

Benavides, G. F.↗

Iodine Standard Materials: Preparation and Inter-Laboratory Comparisons

The Idaho National Laboratory is preparing to enter the community of AMS practioners who analyze for 129Iodine. We expect to take delivery of a 0.5 MV compact accelerator mass spectrometry system, built by NEC, in the early summer of 2014. The primary mission for this instrument is iodine; it is designed to analyze iodine in the +3 charge state. As part of the acceptance testing for this instrument, both at NEC and on-site in our laboratory, some sort of standard or reference material is needed to verify performance. Appropriate standard materials are not readily available in the commercial marketplace. Small quantities can sometimes be acquired from other laboratories already engaged in iodine analyses. In the longer-term, meaningful quantities of standard materials are needed for routine use in analyses, and for quality control functions1. We have prepared some standard materials, starting with elemental Woodward iodine and NIST SRM 3231 [Iodine-129 Isotopic Standard (high level)] 10-6 solution. The goal was to make mixtures at the 5x10-10, 5x10-11, 5x10-12 ratio levels, along with some unmodified Woodward, in the chemical form of silver iodide. Approximately twenty grams of each of these mixtures were prepared. The elemental Woodward iodine was dissolved in chloroform, then reduced to iodide using sodium bisulfite in water. At this point the NIST spike material was added, in the form of sodium iodide. The mixed iodides were oxidized back to iodine in chloroform using hydrogen peroxide. This oxidation step was essential for isotopic equilibration of the 127 and 129 atoms. The iodine was reduced to iodide using sodium bisulfite as before. Excess sulfites and sulfates were precipitated with barium nitrate. After decanting, silver nitrate was used to precipitate the desired silver iodide. Once the silver iodide was produced, the material was kept in darkness as much as possible to minimize photo-oxidation. The various mixtures were synthesized independently of each other; there were no serial dilutions involved. Aliquots of these four materials have been submitted to five established AMS laboratories where iodine analyses are routinely performed: ETH (Zurich), CNA (Seville), PRIME (Purdue), LLNL (California), and Isotrace (Toronto.) Results from four of these laboratories have been received; in general they indicate that the desired 129/127 ratios have been achieved. We will discuss the results of this informal round-robin exercise. If the installation of the instrument in Idaho goes well, we may have some very preliminary results from the new system. An integral part of data reporting is the approach to data reduction. Accordingly, there will also be some discussion of various philosophies of data handling in regard to the use of standards to adjust data, and background subtraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iodine nutritional status and thyroid effects of exposure to ethylenebisdithiocarbamates

Introduction: Italy is still characterized by a mild iodine deficiency and is among the most intensive users of chemical products for agriculture in Europe. The aim of this study was i) to evaluate thyroid effects of exposure to mancozeb, a fungicide widely used in agriculture, in a sample of Italian grapevine workers, and ii) to verify whether the iodine intake may modulate the risk of thyroid disruption due to the mancozeb metabolite ethylenthiourea (ETU). Methods: One hundred seventy-seven occupationally exposed male workers (29 from Chianti, a mild iodine deficient area, and 148 from Bolzano an iodine sufficient province) and 74 non-occupationally exposed male controls (34 from Chianti and 40 from Bolzano) were enrolled in the study. Serum biomarkers of thyroid function, as well as urinary iodine and ETU concentrations were assessed. Moreover all the recruited subjects underwent clinical examination and thyroid ultrasound. Results: Multivariate comparisons showed lower mean serum levels of FT4 in Chianti-workers as compared to Bolzano-workers. Moreover, an increased urinary iodine excretion (>250 µg/L) was more frequently found among more exposed workers (ETU>20 µg/L) than among less exposed ones and this effect was more pronounced in Chianti- than in Bolzano-workers. Chianti-workers also showed a significantly higher frequency of very low thyroid volume (≤6.0 ml) as compared to controls. Conclusions: These findings showed a mild thyroid disrupting effect due to occupational exposure to mancozeb, more pronounced in workers residing in an area characterized by a mild to moderate iodine deficiency as compared to workers residing in an area covered by a long-lasting iodine prophylaxis program. - Highlights: • Thyroid is vulnerable to endocrine disrupting effects due to environmental exposures. • Mancozeb is a fungicide widely used in agriculture worldwide. • Mancozeb is broken down into ethylenthiourea (ETU) which has anti-thyroid activity. • Iodine intake may modulate thyroid disruption due to occupational exposure to ETU.

54 ENVIRONMENTAL SCIENCES↗

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

Measurement of Iodine, Iodide, and Iodate in Hanford Tank Waste: Technology Transfer from PNNL to Hanford 222-S Laboratory

This report summarizes the measurement of the inorganic chemical forms of iodine in Hanford tank waste. The Hanford tank wastes have roughly a part per million iodine. Part of the iodine is the long-lived beta emitter 129I, and the rest is stable 127I. Because tank waste iodine is radioactive and radiotoxic, its chemical form must be known so that its behavior in the vitrification process can be reliably known and anticipated in various waste streams (glass, secondary liquid and solid waste, and offgas emissions) at Hanford. Iodine in tank wastes exists in the inorganic chemical forms iodide and iodate (and possibly also periodate) and also as organic forms such as alkyl iodides. The measurement of organic iodides is very different from the measurement of inorganic forms and is outside the scope of this report. The inorganic chemical forms are chemically separated, in sequence, from the raw tank waste using solvent extractions and several redox reactions, then measured by ICP-MS. The inorganic chemical forms of iodine are chemically reactive, and so is the tank waste. The chemistry must be carefully designed to avoid unintended reactions that could convert one form of iodine to another during the analysis, which would skew the data and report iodine in the wrong chemical form. This iodine analysis, developed at PNNL, is being transferred to the DOE 222-S Laboratory on the Hanford Site, in Washington State, for implementation during waste processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗