Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

First polarization study of the M87 jet and active galactic nuclei at submillimeter wavelengths with ALMA

We investigated the polarization and Faraday properties of Messier 87 (M87) and seven other radio-loud active galactic nuclei (AGNs) at λ0.87 mm (345 GHz) using the Atacama Large Millimeter/submillimeter Array (ALMA). Our goal was to characterize the linear polarization (LP) fractions, measure Faraday rotation measures (RMs), and examine the magnetic field structures in the emission regions of these AGNs. We conducted full-polarization observations as part of the ALMA Band 7 very long baseline interferometry (VLBI) commissioning during the April 2021 Event Horizon Telescope (EHT) campaign. We analyzed the LP fractions and RMs to assess the nature of Faraday screens and magnetic fields in the submillimeter emission regions. We find LP fractions between 1% and 17% and RMs exceeding 10 5 rad m −2 , which are 1–2 orders of magnitude higher than typically observed at longer wavelengths (λ>3 mm). This suggests denser Faraday screens or stronger magnetic fields. Additionally, we present the first submillimeter polarized images of the M87 jet and the observed AGNs, revealing RM gradients and sign reversals in the M87 jet indicative of a kiloparsec-scale helical magnetic field structure. Our results provide essential constraints for calibrating, analyzing, and interpreting VLBI data from the EHT at 345 GHz, representing a critical step toward submillimeter VLBI imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Shock compression of single-crystal austenitic FeCr18Ni12.5 stainless steel to 60 GPa

We measured the austenitic FeCr18Ni12.5 stainless steel Hugoniot as a function of crystallographic direction to approximately 60 GPa. We shock-compressed FeCr18Ni12.5 samples oriented along $\langle$100$\rangle$, $\langle$110$\rangle$, and $\langle$111$\rangle$ to mean stresses ranging 30.5–58.1 GPa via Ta plate impact in a large-bore powder gun and measured the free-surface velocities with laser interferometry. We unambiguously observed the largest post-shock free-surface velocity along $\langle$100$\rangle$ in each experiment, which consequently produced the lowest shock velocity along that orientation. However, the propagation of experimental uncertainties through the impedance matching scheme used to compute the shock velocity produced sufficient uncertainty overlap to preclude definitive conclusion of Hugoniot anisotropy.

36 MATERIALS SCIENCE↗

Longitudinal tapering in gas jets for increased efficiency of 10-GeV class laser plasma accelerators

Modern laser plasma accelerators often require plasma waveguides tens of centimeters long to propagate a high-intensity drive laser pulse. Tapering the longitudinal gas density profile in 10 cm scale gas jets could allow for single stage laser plasma acceleration well beyond 10 GeV with current petawatt-class laser systems. Via simulation and interferometry measurements, we show density control by longitudinally adjusting the throat width and jet angle. Density profiles appropriate for tapering were calculated analytically and via particle-in-cell simulations and were matched experimentally. Further, these simulations show that tapering can increase electron beam energy using 19 J laser energy from ∼9 GeV to > 12 GeV in a 30 cm plasma and the accelerated charge by an order of magnitude.

43 PARTICLE ACCELERATORS↗

Elastic constants in monocrystalline tungsten under quasi-hydrostatic pressures to 11.3 GPa

Compressional (P) and shear (S) wave velocities of tungsten single crystals along the [100] and [110] directions were measured using ultrasonic interferometry at room temperature up to 11.3 GPa. Least-squares fitting of $V$$^{[100]}_{P}$, $V$$^{[100]}_{S}$, $V$$^{[110]}_{P}$, and pressure to finite strain (FS) equations yields the elastic constants: C 11 = 523.5(5) GPa, C 12 = 205.1(32) GPa, and C 44 = 160.8(4) GPa, along with their respective pressure derivatives: $C$$^{′}_{11}$ = 6.20(2), $C$$^{′}_{12}$ = 3.35(1), and $C$$^{′}_{44}$ = 1.65(6). Using the Voigt–Reuss–Hill approximation, the elastic moduli were derived as K S0 = 311.2(22) GPa and G 0 = 160.2(7)GPa, along with their respective pressure derivatives: $K$$^{′}_{S0}$ = 4.30(4) and $G$$^{′}_{0}$ = 1.56(1). The Debye temperature of tungsten was determined to be 380.7(8) K, showing good agreement with previous calorimetric measurements. The elastic anisotropy increases slightly from 1.01(1) at ambient pressure to 1.03(1) at 11.3 GPa, suggesting that tungsten remains nearly isotropic under compression. Poisson's ratio slightly increased from 0.281(3) to 0.288(3) with pressure. Additionally, Pugh's ratio decreased from 0.512(4) to 0.494(4), while Pettifor's ratio increased from 0.148(10) to 0.175(10) as pressure reached 11.3 GPa. These results suggest that tungsten is weakly ductile compared to the critical thresholds for ductile behavior (i.e., Pugh's ratio <0.6 and Pettifor's ratio >0, indicating ductile behavior), but that its ductility increases marginally under pressure.

Wang, Ran [Stony Brook University, NY (United Stat↗

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE↗

Multifrequency eddy-current detection of fast transient thermal signatures for in situ monitoring applications

Eddy-current (EC) nondestructive evaluation has a long history of use in a variety of ex situ defect monitoring applications because of its exquisite sensitivity to local material variations. Due to the relationship between a material's conductivity and its temperature, EC methods have also been used to investigate quasistatic, long-range temperature variations in casting applications. However, these techniques remain underutilized for the measurement of rapidly varying, spatially nonuniform temperature distributions. In this work, we construct a model system capable of generating repeatable temperature transients in steel plates and measure real-time eddy-current signals with millisecond time resolution and spatial resolution of the order of 1 mm. Using a combination of Multiphysics simulations, fast thermal imaging, and time-resolved holographic interferometry, we tease apart contributions to the eddy-current signals arising from temperature variations and transient plate deformation. Finally, we perform a systematic study in which we vary the plate thickness and the eddy-current excitation frequency to demonstrate that eddy-current techniques can provide information about a three-dimensional, time-varying, subsurface thermal distribution, which is inaccessible to the traditional thermal imaging techniques.

Rosenberg, Ethan R. [Lawrence Livermore National L↗

Optical transparency of LiF (100) shock compressed to ∼360 GPa

High-purity [100] lithium fluoride (LiF) is the most widely used optical window in dynamic compression experiments due to its wide bandgap and well-characterized mechanical response. Recent plate-impact experiments established the [100] LiF Hugoniot to ∼230 GPa and demonstrated shock-induced melting onset at 182 GPa with complete melting by 195 GPa; theoretical models predict LiF optical transparency to nearly 900 GPa. To experimentally examine the optical transparency of [100] LiF at higher pressures and in the liquid state, laser-driven shock experiments were performed at peak stresses ranging from 223 to 363 GPa. Optical response was examined by measuring the particle velocity histories at the Kapton/LiF interface using laser interferometry at 532 and 1550 nm wavelengths; in-material particle velocities were obtained using established refractive-index corrections. Continuous photonic Doppler velocimetry fringes were observed across the entire stress range, demonstrating that LiF remains transparent to 1550 nm light throughout the multi-megabar regime investigated. At 532 nm, fringe visibility depended on the reflector coating: aluminum mirrors provided signals to ∼235 GPa, while gold mirrors extended this limit to 270.5 GPa, indicating that the shorter-wavelength response is likely sensitive to experimental configuration rather than to the loss of LiF transparency. Continued optical transparency to at least 360 GPa indicates that shock-melted LiF does not display bandgap closure over the stress range explored. Furthermore, these results provide direct experimental constraints on the high-pressure optical response and establish LiF (100) as a robust optical window material for laser-driven dynamic compression experiments approaching 400 GPa.

Renganathan, P. [Argonne National Laboratory (ANL)↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

XFEL imaging techniques for high energy density and inertial fusion energy research at HED-HiBEF

The imaging platform developed at the High Energy Density-Helmholtz International Beamline for Extreme Fields (HED-HiBEF) instrument at the European X-ray Free Electron Laser (XFEL) and its applications to HED and fusion related research are presented. The platform combines the XFEL beam with the high-intensity short-pulse laser ReLaX and the high-energy nanosecond-pulse laser DiPOLE-100X. The spatial resolution is better than 500 nm and the temporal resolution of the order of 50 fs. The influence of the XFEL source in the x-ray imaging method is discussed. Free-propagation x-ray phase contrast imaging and Talbot-Lau imaging setups are shown. We show examples of blast waves and converging cylindrical shocks in aluminum, resonant absorption measurements of specific charged states in copper with ReLaX and planar shocks in polystyrene material generated by DiPOLE-100X. For the first time, we show the application of Talbot-Lau interferometry to convergent cylindrical shocks as well as resonant absorption processes. We also discuss the possibilities introduced by combining this imaging platform with a kJ-class laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field-level reconstruction from foreground-contaminated 21-cm maps

Current and upcoming 21-cm experiments will soon be able to map 21-cm spatial fluctuations in three dimensions for a wide range of redshifts. However, bright foreground contamination and the nature of radio interferometry create significant challenges, making it difficult to access rich cosmological information from the Fourier modes that lie within the “foreground wedge”. Here, in this work, we introduce two approaches aiming to reconstruct the full 21-cm density field, including the missing modes in the wedge: (a) a field-level inference under an effective field theory (EFT) framework; (b) a diffusion-based deep generative model trained on simulations. Under the EFT framework, we implement a fully differentiable forward model that maps the initial conditions of matter fluctuations to the observed, foreground-filtered 21-cm maps. This enables a gradient-based sampler to simultaneously sample the initial conditions and bias parameters, allowing a physically motivated mode reconstruction. Alternatively, we apply a variational diffusion model to perform 21-cm density reconstruction at the map level. Our model is trained on semi-numerical simulations over a wide range of astrophysical parameters. Our results from both approaches should provide improved cosmological constraints from the field level and also enable cross-correlation between experiments that have little or no overlapping modes.

cosmological perturbation theory↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Directionally asymmetric nonlinear optics in ferrorotational MnTiO 3

Ferrorotationally ordered materials possess a planar chiral lattice of electric dipoles that are a promising platform for exhibiting directionally asymmetric response functions. A key characteristic of such order is that enantiomorph conversion occurs when the solid is flipped by 180° about an in-plane axis. Using second-harmonic interferometry, we show here that when circularly polarized light is incident on MnTiO 3 , the generated harmonic intensity depends on whether the incident light is parallel or antiparallel to the ferrorotational axis. For a particular photon helicity, constructive interference occurs in one direction while destructive interference occurs in the other. Here, our observations represent a fundamentally new optical effect, associated with circularly polarized light in ferrorotational solids, that is distinct from conventional optical activity observed in three-dimensional chiral and Faraday media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmarking of hydrodynamic plasma waveguides for multi-GeV laser-driven electron acceleration

Hydrodynamic plasma waveguides initiated by optical field ionization have recently become a key component of multi-GeV laser wakefield accelerators. Here, we present the most complete and accurate experimental and simulation-based characterization to date, applicable to current multi-GeV experiments and future 100 GeV-scale laser plasma accelerators. Crucial to the simulations is the correct modeling of intense Bessel beam interaction with meter-scale gas targets, the results of which are used as initial conditions for hydrodynamic simulations. The simulations are in good agreement with our experiments measuring evolving plasma and neutral hydrogen density profiles using two-color short pulse interferometry, enabling realistic determination of the guided mode structure for application to laser-driven plasma accelerator design. Published by the American Physical Society 2024

Physics↗

New Method for the Astrometric Direct Detection of Ultralight Dark Matter

Ultralight dark matter induces time-dependent perturbations in the spacetime metric, enabling its . In this Letter, we propose using astrometry to detect dark matter. After reviewing the calculation of the metric in the presence of scalar dark matter, we study the influence of the perturbations on the apparent motion of astrophysical bodies. We apply our results to angular position measurements of quasars, whose vast distances from Earth present an opportunity to discover subcomponent dark matter with a mass as low as 10 − 33 eV . We explore the prospects of very long baseline interferometry and optical astrometric survey measurements for detecting ultralight relics, finding that for the smallest masses, current astrometric surveys can detect dark matter moving locally with a velocity of 10 − 3 with energy density as low as 3 × 10 − 11 GeV / cm 3 . Published by the American Physical Society 2025

Dror, Jeff A. (ORCID:0000000301106184)↗

Reductive quantum phase estimation

Estimating a quantum phase is a necessary task in a wide range of fields of quantum science. To accomplish this task, two well-known methods have been developed in distinct contexts, namely, Ramsey interferometry (RI) in atomic and molecular physics and quantum phase estimation (QPE) in quantum computing. We demonstrate that these canonical examples are instances of a larger class of phase estimation protocols, which we call reductive quantum phase estimation (RQPE) circuits. Here, we present an explicit algorithm that allows one to create an RQPE circuit. This circuit distinguishes an arbitrary set of phases with a smaller number of qubits and unitary applications, thereby solving a general class of quantum hypothesis testing to which RI and QPE belong. We further demonstrate a tradeoff between measurement precision and phase distinguishability, which allows one to tune the circuit to be optimal for a specific application. Published by the American Physical Society 2024

Papadopoulos, Nicholas J. C. (ORCID:00000002635700↗

Quantum Frequency Combs with Path Identity for Quantum Remote Sensing

Quantum sensing promises to revolutionize sensing applications by employing quantum states of light or matter as sensing probes. Photons are the clear choice as quantum probes for remote sensing because they can travel to and interact with a distant target. Existing schemes are mainly based on the quantum illumination framework, which requires quantum memory to store a single photon of an initially entangled pair until its twin reflects off a target and returns for final correlation measurements. Existing demonstrations are limited to tabletop experiments, and expanding the sensing range faces various roadblocks, including long-time quantum storage and photon loss and noise when transmitting quantum signals over long distances. We propose a novel quantum sensing framework that addresses these challenges using quantum frequency combs with path identity for remote sensing of signatures (“qCOMBPASS”). The combination of one key quantum phenomenon and two quantum resources—namely, quantum-induced coherence by path identity, quantum frequency combs, and two-mode squeezed light—allows for quantum remote sensing without requiring quantum memory. The proposed scheme is akin to a quantum radar based on entangled frequency-comb pairs that uses path identity to detect, range, or sense a remote target of interest by measuring pulses of one comb in the pair that never traveled to the target but that contains target information “teleported” by quantum-induced coherence by path identity from the other comb in the pair that traveled to the target but is not detected. We develop the basic qCOMBPASS theory, analyze the properties of the qCOMBPASS transceiver, and introduce the qCOMBPASS equation—a quantum analog of the well-known LIDAR equation in classical remote sensing. We also describe an experimental scheme to demonstrate the concept using two-mode squeezed quantum combs. qCOMBPASS can strongly impact various applications in remote quantum sensing, imaging, metrology, and communications. These applications include detection and ranging of low-reflectivity objects, measurement of small displacements of a remote target with precision beyond the standard quantum limit (SQL), standoff hyperspectral quantum imaging, discreet surveillance from space with low detection probability (detect without being detected), very-long-baseline interferometry, quantum Doppler sensing, quantum clock synchronization, and networks of distributed quantum sensors. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗