Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES↗

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering↗

X-ray scattering based scanning tomography for imaging and structural characterization of cellulose in plants

X-ray and neutron scattering have long been used for structural characterization of cellulose in plants. Due to averaging over the illuminated sample volume, these measurements traditionally overlooked the compositional and morphological heterogeneity within the sample. Here, a scanning tomographic imaging method is described, using contrast derived from the X-ray scattering intensity, for virtually sectioning the sample to reveal its internal structure at a resolution of a few micrometres. This method provides a means for retrieving the local scattering signal that corresponds to any voxel within the virtual section, enabling characterization of the local structure using traditional data-analysis methods. This is accomplished through tomographic reconstruction of the spatial distribution of a handful of mathematical components identified by non-negative matrix factorization from the large dataset of X-ray scattering intensity. Joint analysis of multiple datasets, to find similarity between voxels by clustering of the decomposed data, could help elucidate systematic differences between samples, such as those expected from genetic modifications, chemical treatments or fungal decay. The spatial distribution of the microfibril angle can also be analyzed, based on the tomographically reconstructed scattering intensity as a function of the azimuthal angle.

36 MATERIALS SCIENCE↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Specifications of Legacy U(Pu)Zr Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Program has supported the creation of several databases with information describing the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data is one of the most important types of PIE data being collected, organized and stored in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three main sets of metallography data. The first set is the metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins measured in the Hot Fuel Examination Facility (HFEF); the second set is the metallography data from EBR-II irradiated fuel pins measured in the Alpha-Gamma Hot Cell Facility (AGHCF); the third set is the metallography data from transient tested fuel pins (the transients tests include the out-of-pile tests and TREAT tests) measured in AGHCF. Since both the second and third sets of data were measured in AGHCF, they are governed by the same specification. The metallography data in the databases are digital images scanned from either positive or negative photos. The quality of the images, including their resolution and contrast, relies on the preserved quality of the pictures and the scanning conditions. To analyze the microstructure of a fuel pin, a series of preparatory steps must be undertaken. These include sectioning, epoxy mounting, mechanical grinding and polishing, and often etching. The resulting samples were then transferred to a secondary hot cell, or glovebox (depending the strength of radiation field) for microscopy examination. The specifications provided herein focus on the metallography examinations. The sample grinding, polishing and etching processes are also discussed. The procedures involving sectioning and epoxy mounting are out of the scope of the current specification; details can be found in the corresponding operation manuals. If more data are collected and added to the ART Fast Reactor Databases, this specification will be updated to accommodate the additional data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Application of Weak-Beam Dark-Field STEM for Dislocation Loop Analysis

Nanoscale dislocation loops formed by irradiation can significantly contribute to both irradiation hardening and embrittlement of materials when subjected to extreme nuclear reactor environments. Here, this study explores the application of weak-beam dark-field (WBDF) scanning transmission electron microscopy (STEM) methods for quantitative irradiation-induced defect analysis in crystalline materials, with a specific focus on dislocation loop imaging and analysis. A high-purity Fe-5 wt% Cr model alloy was irradiated with 8 MeV Fe 2+ ions at 450°C to a fluence of 8.8 × 10 19 m -2 , inducing dislocation loops for analysis. While transmission electron microscopy (TEM) has traditionally been the primary tool for dislocation imaging, recent advancements in STEM technology have reignited interest in using STEM for defect imaging. This study introduces and compares three WBDF STEM methods, demonstrating their effectiveness in suppressing background contrasts, isolating defect information for dislocation loop type classification, providing finer dislocation line images for small loop analysis, and presenting inside–outside contrast for identifying loop nature. Experimental findings indicate that WBDF STEM methods surpass traditional TEM approaches, yielding clearer and more detailed images of dislocation loops. The study concludes by discussing the potential applications of WBDF STEM techniques in defect analysis, emphasizing their adaptability across various material systems beyond nuclear materials.

36 MATERIALS SCIENCE↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Effects of ZrN Coating and Heat Treatment on U-Mo Dispersion Fuel under Irradiation

The stability of U-Mo fuel particles in Al matrix can be improved using ZrN coating and heat treatment. This study investigated irradiation behaviors of fuel plates containing U-Mo fuel particles fabricated with different conditions including heat treatment and the thickness of ZrN coating. Additionally, different fission densities were applied to each fuel plate to understand how varying fission densities affect its irradiation behaviors. This study showed that more recrystallization of grains and development of high burnup structure (HBS) occurred in irradiated fuel particles with higher fission densities. Heat treatment reduced the accumulation of fission gas bubbles in the fuel particles by coarsening their grains. The fuel particles with a ZrN coating thickness of 1.2-1.8 µm showed less significant development of U-Mo/Al interaction layers than the particles with a coating thickness of 0.5 µm after irradiation. This might indicate the existence of a critical thickness of ZrN coating to minimize the formation of the interaction layers. Fission gas bubbles were observed at grain boundaries of irradiated U-Mo fuel particles at low fission densities, and the formation of dendritic features with a darker contrast was identified in backscattered electron images. These features stemmed from grain boundaries with fission gas bubbles or HBS, and some of them contained the bubbles, indicating that they might represent an early stage of HBS propagation in the fuel particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Characterization of Si particles in additively manufactured AlSi10Mg using synchrotron transmission X-ray nanotomography

In AlSi10Mg samples manufactured by Laser Powder Bed Fusion, distinguishing the Si eutectic network/Si particles from the Al matrix by X-ray imaging is challenging due to the low absorption contrast between the Al and Si. This work investigates the possibility of overcoming this obstacle in synchrotron transmission X-ray microscopy. Effects of both different defocusing conditions and X-ray beam energies are evaluated and optimal conditions are identified for imaging a sample annealed post-print for 2h at 520°C. It is shown that both large particles (e.g. 4μm) and particles as small as 0.5 μm, can be imaged with reasonable precision in 3D non-destructively.

Defer, M.↗

Corrosion susceptibility and chromium loss in Austenitic steels and Nickel-based alloys in molten FLiNaK at 700 °C

A comparative study was conducted to evaluate the corrosion susceptibility of 316L, 316H, Ni 200, Inconel 625, and Hastelloy N in molten FLiNaK at 700 °C for 100 h. Top-view and cross-sectional scanning electron microscopy (SEM) imaging, combined with energy-dispersive X-ray spectroscopy (EDS) mapping, was performed to investigate microstructural and compositional changes. SEM images were further processed by introducing a contrast threshold to map cavity distribution. Using EDS mapping, intergranular and intragranular Cr loss were separately characterized. The ranking of mass loss after corrosion, from highest to lowest, is as follows: 316H > 316L > Inconel 625 > Hastelloy N > Ni 200. Cr loss was found to be correlated with Mo concentration, in agreement with many previous studies, with higher Mo content resulting in reduced Cr loss. On the other hand, there is no evidence that the high carbon content in 316H enhances corrosion resistance. The relatively low solubility of carbon in austenite at the testing temperature limits the amount of dissolved carbon. Therefore, the carbon-retarded vacancy diffusion, and consequently the reduced Cr diffusion, were not observed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

Characterization of latent image of electron beam resist via critical-dimension resonant soft X-ray scattering

Metrology plays a crucial role in semiconductor manufacturing by providing accurate and precise measurement and characterization of critical parameters. With the development of high-resolution extreme ultraviolet lithography (EUVL) processes, critical dimensions are shrinking to sub-10 nm. Resist materials encounter the challenge of providing heightened sensitivity and a handle on exacerbating stochastic variations. A comprehensive understanding of the chemical profile of the latent image is pivotal for mitigating stochastic effects and optimizing pattern quality. However, the subtle differences in chemistry between the exposed and unexposed regions of the resists make it extremely challenging to characterize the latent images with sub-nanometer precision. Here, we develop the metrology with critical-dimension resonant soft X-ray scattering (CD-RSoXS) to probe the chemical profiles of latent images stored in resist after exposure. The combination of absorption spectroscopy and enhanced scattering contrast makes it possible to characterize the subtle structural and chemical variations in the latent image. Moreover, the results of the measurements are compared with the simulations with a finite element method–based Maxwell solver to extract a detailed profile of the latent and developed images. We demonstrate that the CD-RSoXS technique can provide valuable insights into the high spatial resolution and local chemical sensitivity simultaneously, which is crucial to understanding the resolution limits and stochastic effects in EUVL processes.

36 MATERIALS SCIENCE↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗