Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of applied fields for ion mobility separations in traveling wave based structures for lossless ion manipulations (SLIM)

Ion mobility (IM) is rapidly gaining attention for the analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM has limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. These can be readily obtainable in structures for lossless ion manipulations (SLIM), which are fabricated from electric fields that are generated by appropriate potentials applied to arrays of electrodes patterned on two parallel surfaces. In this work we have investigated the relationship between the various SLIM variables, such as electrode dimensions, inter-surface gap, and the TW applied voltages, that directly impact the fields experienced by ions. Ion simulation and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric field. The variables explored impact both ion confinement and the observed IM resolution in Structures for Lossless Ion Manipulations (SLIM) modules.

Hamid, Ahmed M.↗

Lymphoscintigraphy Can Select Breast Cancer Patients for Internal Mammary Chain Radiotherapy

Purpose: Given the risk of undesired toxicity, prophylactic internal mammary (IM) chain irradiation should be offered only to patients at high risk of occult involvement. Lymphoscintigraphy for axillary sentinel node biopsy might help in selecting these patients. Methods and Materials: We reviewed published studies with the following selection criteria: {>=}300 breast cancer patients referred for axilla sentinel node biopsy; scintigraphy performed after peritumoral or intratumoral tracer injection; IM biopsy in the case of IM drainage; and axilla staged routinely independent of IM status. Results: Six prospective studies, for a total of 3,876 patients, fulfilled the inclusion criteria. Parasternal drainage was present in 792 patients (20.4%). IM biopsy was performed in 644 patients and was positive in 111 (17.2%). Of the positive IM biopsies, 40% were associated with tumors in the lateral breast quadrants. A major difference in the IM positivity rate was found according to the axilla sentinel node status. In patients with negative axilla, the IM biopsy was positive in 7.8% of cases. In patients with positive axilla, however, the IM biopsy was positive in 41% (p < .00001). Because biopsy of multiple IM hot nodes is difficult, the true risk could be even greater, probably close to 50%. Conclusions: Patients with IM drainage on lymphoscintigraphy and a positive axilla sentinel node have a high risk of occult IM involvement. These women should be considered for IM radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imidazole and 1-Methylimidazole Hydrogen Bonding and Nonhydrogen Bonding Liquid Dynamics: Ultrafast IR Experiments

Dynamics of imidazole (IM) and 1-methylimidazole (1-MeIM) in the liquid phase at 95 °C were studied by IR polarization selective pump-probe (PSPP) and two-dimensional IR (2D IR) spectroscopies. The two molecules are very similar structurally except that IM can be simultaneously a hydrogen bond donor and acceptor and therefore forms extended hydrogen bonded networks. The broader IR absorption spectrum and shorter vibrational lifetime of the vibrational probe, selenocyanate anion (SeCN – ), in IM vs. 1-MeIM indicate that stronger hydrogen bonding exists between SeCN – and IM. Molecular dynamics (MD) simulations support the strong hydrogen bond formation between SeCN – and IM via the HN moiety. SeCN – makes two H-bonds with IM; it is inserted in the IM H-bonded chains rather than being a chain terminator. The strong hydrogen bonding influenced the reorientation dynamics of SeCN – in IM, leading to more restricted short time angular sampling (wobbling-in-a-cone). The complete orientational diffusion time in IM is 1.7 times slower than in 1-MeIM, but the slowdown is less than expected, considering the 3-fold larger viscosity of IM. The jump reorientation mechanism accounts for the anomalously fast orientational relaxation in IM, and the MD simulations determined the average jump angle of the probe between hydrogen bonding sites. Spectral diffusion time constants obtained from the 2D IR experiments are only modestly slower in IM than in 1-MeIM in spite of the significant increase in viscosity. Here, the results indicate that the spectral diffusion sensed by the SeCN – has IM hydrogen bond dynamics contributions not present in 1-MeIM.

14 SOLAR ENERGY↗

Dual Polarity Ion Confinement and Mobility Separations

Structures for Lossless Ion Manipulations (SLIM) have been rapidly gaining prominence for applications where ultra-high resolution Ion Mobility (IM) separations are desired to provide performance features and information unattainable using the currently available IM platforms. Although most routine analyses are done in either positive or negative polarity modes, there are significant benefits to both, potentially making them highly complementary if performed simultaneously. In the effort to develop a robust dual polarity IM platform, we explored an evaluation of a novel SLIM platform developed to perform simultaneous cationic and anionic IM separations (i.e. without requiring polarity switching).

Attah, Isaac K.↗

High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features

Abstract High-resolution ion mobility (resolving power > 200) coupled with mass spectrometry (MS) is a powerful analytical tool for resolving isobars and isomers in complex samples. High-resolution ion mobility is capable of discerning additional structurally distinct features, which are not observed with conventional resolving power ion mobility (IM, resolving power ~ 50) techniques such as traveling wave IM and drift tube ion mobility (DTIM). DTIM in particular is considered to be the “gold standard” IM technique since collision cross section (CCS) values are directly obtained through a first-principles relationship, whereas traveling wave IM techniques require an additional calibration strategy to determine accurate CCS values. In this study, we aim to evaluate the separation capabilities of a traveling wave ion mobility structures for lossless ion manipulation platform integrated with mass spectrometry analysis (SLIM IM-MS) for both lipid isomer standards and complex lipid samples. A cross-platform investigation of seven subclass-specific lipid extracts examined by both DTIM-MS and SLIM IM-MS showed additional features were observed for all lipid extracts when examined under high resolving power IM conditions, with the number of CCS-aligned features that resolve into additional peaks from DTIM-MS to SLIM IM-MS analysis varying between 5 and 50%, depending on the specific lipid sub-class investigated. Lipid CCS values are obtained from SLIM IM ( TW(SLIM) CCS) through a two-step calibration procedure to align these measurements to within 2% average bias to reference values obtained via DTIM ( DT CCS). A total of 225 lipid features from seven lipid extracts are subsequently identified in the high resolving power IM analysis by a combination of accurate mass-to-charge, CCS, retention time, and linear mobility-mass correlations to curate a high-resolution IM lipid structural atlas. These results emphasize the high isomeric complexity present in lipidomic samples and underscore the need for multiple analytical stages of separation operated at high resolution. Graphical abstract

Reardon, Allison R. (ORCID:0000000165830134)↗

Coulombic Effects on Ion Mobility Spectrometry

The ion mobility spectrometry (IMS) is now taking its place among widely applied analytical methods. When coupled with mass spectrometers (MS), IMS becomes a powerful analytical tool for separating complex samples and investigating molecular structure, and improvements of IMS-MS instrumentation, e.g. to IMS resolving power and sensitivity, are highly desirable. Implementation of an ion trap for accumulation and pulsed ion injection to IMS based on the ion funnel has provided considerably increased ion currents, and thus a basis for improved sensitivity and (indirectly) measurement throughput. However, large ion populations may manifest Coulombic effects contributing to the spatial dispersion of ions traveling in the IMS drift tube, and thus affect IMS resolving power. In this study we present an analysis of Coulombic effects on IMS resolution. Basic relationships have been obtained for the spatial evolution of ion packets due to Coulombic repulsion. The theoretical relationships were compared with results of a computer model that simulates IMS operation based on a first principles approach. Initial experimental results reported here are consistent with the computer modeling and these relationships. A noticeable decrease of the IMS resolving power was observed for specific ion populations of >10,000 elementary charges. IMS operation conditions to minimize Coulombic effects, while minimizing sacrifices to performance, are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling of a High-Resolution Ambient Pressure Drift Tube Ion Mobility Spectrometer to a Commercial Time-of-flight Mass Spectrometer

Ion mobility spectrometry provides information about molecular structures of ions. Hence, high resolving power allows separation of isomers which is of major interest in several applications. In this work, we couple our high-resolution ion mobility spectrometer (IMS) with a resolving power of R{sub p} = 100 to a time-of-flight mass spectrometer (TOF-MS). Besides, the benefit of an increased resolving power such an IMS-MS also helps analyzing and understanding the ionization processes in IMS. Usually, the coupling between IMS and TOF-MS is realized by synchronizing data acquisition of the IMS and MS resulting in two-dimensional data containing ion mobility and mass spectra. However, due to peak widths of less than 100 μs in our high-resolution IMS, this technique is not practicable due to significant peak broadening during the ion transfer into the MS and an insufficient data acquisition rate of the MS. Thus, a novel but simple interface between the IMS and MS has been designed which minimizes ion losses, allows recording of ion mobility at full IMS resolving power, and enables a shuttered transmission of ions into the MS. The interface is realized by replacing the Faraday plate used in IMS by a Faraday grid that is shielded by two additional aperture grids. For demonstration, positive product ions of benzene, toluene, and m-xylene in air are investigated. The IMS is equipped with a radioactive {sup 3}H source. Besides the well-known product ions M{sup +} and M·NO{sup +}, a dimer ion is also observed for benzene and toluene, consisting of two molecules and three further hydrogen atoms. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THERMAL ESCAPE IN THE HYDRODYNAMIC REGIME: RECONSIDERATION OF PARKER's ISENTROPIC THEORY BASED ON RESULTS OF KINETIC SIMULATIONS

The one-dimensional steady-state problem of thermal escape from a single-component atmosphere of mon- and diatomic gases is studied in the hydrodynamic (blow-off) regime using the direct simulation Monte Carlo method for an evaporative-type condition at the lower boundary. The simulations are performed for various depths into an atmosphere, indicated by a Knudsen number, Kn{sub 0}, equal to the ratio of the mean free path of molecules to the radial position of the source surface, ranging from 10 to 10{sup -5}, and for the range of the source Jeans parameter, {lambda}{sub 0}, equal to the ratio of gravitational and thermal energies, specific to blow-off. The results of kinetic simulations are compared with the isentropic model (IM) and the Navier-Stokes model. It is shown that the IM can be simplified if formulated in terms of the local Mach number and Jeans parameter. The simulations predict that at Kn{sub 0} < {approx} 10{sup -3} the flow includes a near-surface non-equilibrium Knudsen layer, a zone where the flow can be well approximated by the IM, and a rarefied far field. The corresponding IM solutions, however, only approach Parker's critical solution as {lambda}{sub 0} approaches the upper limit for blow-off. The IM alone is not capable for predicting the flow and requires boundary conditions at the top of the Knudsen layer. For small Kn{sub 0}, the scaled escape rate and energy loss rate are found to be independent of {lambda}{sub 0}. The simulation results can be scaled to any single-component atmosphere exhibiting blow-off if the external heating above the lower boundary is negligible, in particular, to sublimation-driven atmospheres of Kuiper belt objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IMIDAZOLE-BASED IONIC LIQUIDS FOR USE IN POLYMER ELECTROLYTE MEMBRANE FUEL CELLS: EFFECT OF ELECTRON-WITHDRAWING AND ELECTRON-DONATING SUBSTITUENTS

Current polymer electrolyte membrane fuel cells (PEMFCs) require humidifi cation for acceptable proton conductivity. Development of a novel polymer that is conductive without a water-based proton carrier is desirable for use in automobiles. Imidazole (Im) is a possible replacement for water as a proton solvent; Im can be tethered to the polymer structure by means of covalent bonds, thereby providing a solid state proton conducting membrane where the solvating groups do not leach out of the fuel cell. These covalent bonds can alter the electron availability of the Im molecule. This study investigates the effects of electron-withdrawing and electron-donating substituents on the conductivity of Im complexed with methanesulfonic acid (MSA) in the form of ionic liquids. Due to the changes in the electronegativity of nitrogen, it is expected that 2-phenylimidazole (2-PhIm, electron-withdrawing) will exhibit increased conductivity compared to Im, while 2-methylimidazole (2-MeIm, electron-donating) will exhibit decreased conductivity. Three sets of ionic liquids were prepared at defi ned molar ratios: Im-MSA, 2-PhIm-MSA, and 2-MeIm- MSA. Differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and 1H-NMR were used to characterize each complex. Impedance analysis was used to determine the conductivity of each complex. Both the 2-PhIm-MSA and 2-MeIm-MSA ionic liquids were found to be less conductive than the Im-MSA complex at base-rich compositions, but more conductive at acid-rich compositions. 1H-NMR data shows a downfi eld shift of the proton on nitrogen in 2-PhIm compared to Im, suggesting that other factors may diminish the electronic effects of the electron withdrawing group at base-rich compositions. Further studies examining these effects may well result in increased conductivity for Im-based complexes. Understanding the conductive properties of Im-derivatives due to electronic effects will help facilitate the development of a new electrolyte appropriate for automotive fuel cell use.

Chang, E↗

A comprehensive review on experimental and clinical findings in intermediate syndrome caused by organophosphate poisoning

Acute organophosphate (OP) intoxication is important because of its high morbidity and mortality and occurrence of muscular paralysis associated by inhibition of acetylcholinesterase (AChE) activity at the neuromuscular junction. Cholinergic crisis, intermediate syndrome (IMS), and OP-induced delayed neuropathy (OPIDN) are the evidences that can be observed in OP intoxication. The main cause of morbidity due to OP poisoning is IMS that occurs 24–96 h after poisoning. Mechanisms underlying the IMS are not fully known. Although the electrophysiological aspects of delayed neuropathy are best characterized, the IMS remain very little studied. The aim of this study was to revisit current knowledge related to OP and the IMS. For this purpose, a systematic review without date limitation was performed. A total of 599 relevant articles were found and reviewed. Data were categorized according to experimental and clinical studies. Occurrences of persistent AChE inhibition, electromyography changes, muscle cell injury, and oxidative stress are the most important pieces of evidence for involvement of IMS in OP toxicity. Delayed AChE inhibition, muscle necrosis, down regulation or desensitization of postsynaptic ACh receptors, failure of postsynaptic ACh release, and oxidative stress-related myopathy are involved in IMS. Toxicokinetic factors, such as a high lipid-solubility, duration of AChE inhibition and metabolite excretion, evolution of alterations on repetitive nerve stimulation (RNS), type and frequency of muscle lesions can estimate the probability of the IMS. Plasma AChE of less than 200 units is a predictor and the 30 Hz RNS decremental response could be a useful marker for the IMS.

60 APPLIED LIFE SCIENCES↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Azobenzene-based organic salts with ionic liquid and liquid crystalline properties

Two sets of new azobenzene-based bromide salts are synthesized, and their thermal photochromic properties are studied. Both sets are based on the imidazolium cation. The first set (1) features a symmetric biscation where two imidazolium head groups (Im) with different alkyl chains (Cn) are connected to a central azobenzene unit (Azo): [Azo(C1-Im-Cn) 2 ]; n = 6, 8, 10, 12, 14. The other one contains an n-alkyl-imidazolium cation (Cn-Im) bearing a terminal azobenzene unit (C1-Azo) substituted with an alkoxy chain (O-Cm) of either two (2) or six (3) carbon atoms: [C1-Azo-O-Cm-Im-Cn]; m = 2, n = 8, 10, 12 and m = 6, n = 8, 10, 12, 14, 16. For both cation classes, the influence of alkyl chains of varying length on the thermal phase behavior was investigated by differential scanning calorimetry (DSC) and polarizing optical microscopy (POM). For five compounds (Azo(-C1-Im-C12) 2 (1d), Azo(-C1-Im-C12) 2 (1e), C1-Azo-O-C2-Im-C10 (2b), C1-Azo-O-C2-Im-C12 (2c), and C1-Azo-O-C6-Im-C16 (3e)), the formation of a liquid crystalline phase was observed. The biscationic salts (1) are all comparatively high melting organic salts (180–240 °C), and only the two representatives with long alkylchains (C12 and C14) exhibit liquid crystallinity. The monocationic salts with an O–C2 bridge (2) melt between 140 and 170 °C depending on the alkyl chain length, but from an alkyl chain of 10 and more carbon atoms on they form a smectic A liquid crystalline phase. The representatives of the third set with a O–C6 bridge qualify as ionic liquids with melting points less than 100 °C. However, only the representative with a hexadecyl chain forms a liquid crystalline phase. Representative single crystals for all sets of cations could be grown that allowed for single crystal structure analysis. Together with small-angle X-ray scattering experiments they allow for a more detailed understanding of the thermal properties. As a result, through irradiation with UV-light (320–366 nm) all compounds undergo trans–cis isomerization, which reverses under visible light (440 nm).

36 MATERIALS SCIENCE↗

Synthesis of Anhydrous Acetates for the Components of Nuclear Fuel Recycling in Dialkylimidazolium Acetate Ionic Liquids [plus supplemental information]

A series of anhydrous acetate salts with uranium {[C 2 C 1 im][UO 2 (OAc) 3 ] (1), [C 2 C 2 im][UO 2 (OAc) 3 ] (2), and [C 4 C 1 im][UO 2 (OAc) 3 ] (3)}, lanthanides {[C 2 C 2 im] 2 [La(OAc) 5 ] (4) and [C 2 C 1 im] 2 [Nd(OAc) 5 ] (5)}, and strontium {[C 2 C 1 im] n [Sr- (OAc) 3 ] n (6)} (where C 2 C 1 im = 1-ethyl-3-methylimidazolium, C 2 C 2 im = 1,3-diethylimidazolium, C 4 C 1 im = 1-butyl-3-methylimi-dazolium, and OAc = acetate) have been prepared and structurally characterized. Both lanthanides and strontium are common components of the nuclear fuel waste, and their separation from uranium is an important but still challenging task. A new synthetic method with dialkylimidazolium acetate ionic liquids (ILs) as the solvent has been developed for the direct synthesis of homoleptic acetates from the corresponding hydrates and, unexpectedly, hardly soluble f-element oxides. Although the group of characterized compounds shows perfect structural variability, all actinide and lanthanide metal ions form monomeric complex anions where the metal cation coordinates to five ligands including two oxygen atoms in the case of uranium, as is commonly observed for uranyl compounds. Crystallographic analyses revealed that the complex [UO 2 (OAc) 3 ] - anions possess rather standard D 3h symmetry featuring a hexagonal-bipyramidal coordination environment, while the lanthanide anions [Ln(OAc) 5 ] 2- are fully asymmetric and the Ln 3+ cations are 10-coordinated in the form of a distorted bicapped tetragonal antiprism. This is the first report of lanthanide ions coordinated in this fashion. For Sr 2+ , 9-fold coordination through oxygen atoms in the form of a strongly distorted tricapped trigonal prism is observed. Furthermore, the crystallization of anhydrous, homoleptic, anionic acetate complexes from such a large variety of different metal salts appears to be due to the properties of dialkylimidazolium acetate ILs themselves, including enhanced basicity from the high concentration of free anions and their greater affinity for hydrogen-bonding solutes relative to metal cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic time-warping correction for shifts in ultrahigh resolving power ion mobility spectrometry and structures for lossless ion manipulations

Detection of arrival time shifts between ion mobility spectrometry (IMS) separations can limit achievable resolving power (Rp), particularly when multiple separations are summed or averaged, as commonly practiced. Such variations are more apparent in higher Rp measurements, and are particularly evident in long path length traveling wave structures for lossless ion manipulations (SLIM) IMS due to their typically much longer separation times. Here we explore the utility of a data processing approaches employing linear alignment (LA) and nonlinear dynamic time warping (DTW) of IMS separations to correct for variations between separations, such as due to pressure fluctuations. For multipass SLIM IMS separations, where narrow mobility range measurements have arrival times that can extend to several seconds, the LA approach effectively corrected for such variations, and significantly improvement Rp for summed separations. However, LA was much less effective for high Rp broad mobility range separations, such as obtained with multilevel SLIM IMS. Changes in IMS arrival times ions were observed to be correlated with small pressure changes, with approximately 0.6% relative arrival time shifts being common, sufficient to result in a loss of Rp for summed separations. Comparison of the approaches showed DTW alignment performed similarly to LA when used over a narrow mobility range, but was significantly better (providing narrower peaks and higher signal intensities) for wide mobility range data. We found the DTW approach increased Rp by as much as 115% for measurements in which 50 IMS separations over 2 seconds were summed, and leading to a large improvement in effective Rp. We conclude that DTW is superior to LA for ultrahigh resolution broad mobility range SLIM IMS separations, correcting for ion arrival time shifts regardless of the cause. Our tool is publicly available for use with universal ion mobility format (.UIMF) and text (.txt) files.

Data alignment, dynamic time warping, ion mobility↗

Improving Heat Conduction of Insulated Metal Substrate with Thermal Pyrolytic Graphite Core for SiC Power Module Packaging

TPG-core IMS concept was jointly explored in this study. Integrating high thermally conductive TPG graphite core into IMS is expected to simultaneously achieve high thermal conductivity from TPG and electrical functionalities from IMS. Nearly 2x thermal conductivity and 30% weight saving was demonstrated on TPG-core IMS compared to conventional Cu-core IMS. Significant junction temperature reduction (11°C) in steady state and power cycling was revealed by the thermal analysis as the result of improved thermal spreading in plane and through the thickness. The study also proved the manufacturability and compatibility of this TPG-core IMS structure to the existing IMS production and power module assembling. Finally, the integration of TPG and IMS paves a new packaging route to increase heat load, improve reliability, simplify module design and reduce assembling cost and number of steps.

36 MATERIALS SCIENCE↗