Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IEEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Discussion of Time Management Concepts and Time Constraint Equations for Multi-Rate Federation Executions

The High Level Architecture (HLA) is a simulation interoperability standard developed by the Simulation Interoperability Standards Organization (SISO) and published as the international standard IEEE 1516-2010 by the Institute for Electrical and Electronics Engineers (IEEE). HLA is a widely used standard for the development and execution of collaborative distributed simulations. HLA provides a number of Management Services to simulation developers: Federation, Declaration, Object, Ownership, Data Distribution, and Time. Of those services, Time Management Services is probably one of the least understood and least used. However, Time Management Services are critical to technical simulations like those created for space systems using the Space Reference Federation Object Model (SpaceFOM). Time Management can be used to insure data coherence and execution repeatability in distributed simulations. When combined with real time execution policies, Time Management is being used to support real time execution of mixed software and hardware in the loop integration, verification, and validation simulations for active space systems development. This paper starts by providing an overview of the HLA Time Management Services. This provides the background to discuss the challenges associated with Time Management and its use, starting with simple common rate frame scheduled simulations, then simple multi-rate simulations, and ending with complex mixed rate simulations. The authors then formulate the significant time constraint relationships between identified frame scheduling parameters. The intent of the paper is to provide a concise discussion of how to use Time Management in both simple cases and in more complex mixed frame rate federation executions.

Simulation Interoperability↗

A Discussion of Time Management Concepts and Time Constraint Equations for Multi-Rate Federation Executions

The High Level Architecture (HLA) is a simulation interoperability standard developed by the Simulation Interoperability Standards Organization (SISO) and published as the international standard IEEE 1516-2010 by the Institute for Electrical and Electronics Engineers (IEEE). HLA is a widely used standard for the development and execution of collaborative distributed simulations. HLA provides a number of Management Services to simulation developers: Federation, Declaration, Object, Ownership, Data Distribution, and Time. Of those services, Time Management Services is probably one of the least understood and least used. However, Time Management Services are critical to technical simulations like those created for space systems using the Space Reference Federation Object Model (SpaceFOM). Time Management can be used to insure data coherence and execution repeatability in distributed simulations. When combined with real time execution policies, Time Management is being used to support real time execution of mixed software and hardware in the loop integration, verification, and validation simulations for active space systems development. This paper starts by providing an overview of the HLA Time Management Services. This provides the background to discuss the challenges associated with Time Management and its use, starting with simple common rate frame scheduled simulations, then simple multi-rate simulations, and ending with complex mixed rate simulations. The authors then formulate the significant time constraint relationships between identified frame scheduling parameters. The intent of the paper is to provide a concise discussion of how to use Time Management in both simple cases and in more complex mixed frame rate federation executions.

Simulation Interoperability↗

High voltage design guide for airborne equipment

The report supplies the theoretical background and design techniques needed by an engineer who is designing electrical insulation for high-voltage high-power components, equipment, and systems on aircraft. A literature survey and abundant bibliography identify references that provide further data on the subjects of partial discharges, corona, field theory and plotting, voids and processes for applying insulation. Both gaseous and solid insulations are treated. Cryogenic and liquid design notes are included. Tests and test equipment for high voltage insulation and equipment are defined. Requirements of test plans and procedures for high-voltage high-power equipment are identified and illustrated by examples. Suggestions for high-voltage specifications are provided. Very few of the Military and Government specifications deal with system voltages above 10kv, thus most aircraft high-voltage specifications will have to be derived from the power industry specifications and standards produced by ASTM, IEEE, and NEMA.

W G Dunbar↗

Basic avionics module design for general aviation aircraft

The design of an advanced digital avionics system (basic avionics module) for general aviation aircraft operated with a single pilot under IFR conditions is described. The microprocessor based system provided all avionic functions, including flight management, navigation, and lateral flight control. The mode selection was interactive with the pilot. The system used a navigation map data base to provide operation in the current and planned air traffic control environment. The system design included software design listings for some of the required modules. The distributed microcomputer uses the IEEE 488 bus for interconnecting the microcomputer and sensors.

Smyth, R. K.↗

Automation of the Mark 3 field system

The software and hardware components which will enable hands off operation are described. The operation of the field system begins with the scheduling of observations. An interactive program, SKED, provides displays of mutual visibility, automatic calculation of telescope slewing times, and the ability to list and edit the schedule. The output of SKED is a schedule file containing commands in the Standard Notation for Astronomy Procedures (SNAP) language which the field system uses for controlling events during the experiment. The most important features of SNAP include sophisticated time sequencing of events, automatic logging of all commands and responses, and the ability to define often used sequences of commands as procedures. A control program, BOSS, running in an HP 1000 minicomputer, reads the SNAP commands from a schedule file and interprets them in terms of commands and requests to devices. Interactive command input is possible through the operator's display terminal. Communication with all of the Mark 3 electronics modules is done via a small general purpose interface board (a microprocessor based ASCII transceiver) which has been installed in each module. Additional devices are controlled and monitored using the IEEE 488 General Purpose Interface Bus.

Vandenbere, N. R.↗

Mark 3 correlator hardware and software

The Mark 3 correlator system is described in some detail. The correlator system is based on a modular philosophy. Each correlator module independently processes the data from one track pair. Therefore, 28 modules are necessary to complete a full one baseline processor and 84 modules for a full 3 baseline processor. Each correlator module has two interfaces: (1) data and clock from each of the two tracks to be correlated and (2) Computer Automated Measurement and Control (CAMAC) dataway interface to the computer. The processor is organized around the IEEE CAMAC standard architecture, housing 15 correlator modules in each of 6 crates. This allows one pass processing of a full 3 baseline 28 track observation or a 6 baseline (4 station) 14 track observation. The correlator architecture allows easy expansion for up to 8 stations. The computer system is an HP 1000 system utilizing a 16 bit minicomputer with disc and tape peripherals. The processing software is also organized in a modular fashion with many independent but cooperative programs controlling the operation of the Mark 3 processor. Processing time through the correlator is normally real time or faster, with graphics displays providing real time monitor and control of the processing operation.

Whitney, A. R.↗

Distributed microprocessors in a tactical universal modem

The distributed microprocessor system associated with a wideband signal conversion unit (WBSCU) is described. Multiple embedded 8086 and 2901 microprocessors, supported by dedicated hardware modules, perform the required real time operations for both transmit and receive functions. Commands from a host computer determine the configuration of the WBSCU via the IEEE 488 bus. Each of the four WBSCU channels is assigned to process a specified IF waveform; each channel configures its own resources and, in some cases, borrows resources from other channels. The processed waveform data is communicated from individual channels to redundant global memories. Data flow between the user community and global memories occurs via redundant 1553 buses through intelligent Bus Interface Units. Each WBSCU channel contains one 2901 bit slice machine and one 8086 microprocessor. The 2901 provides high speed processing capability for the most time critical operations. The 8086 is used for lower speed processing tasks where its high level language capability can be better exploited. Each 8086 has a global bus for wideband interprocessor communication, and a local bus for 8086/2901, master/slave communication. Software architecture consists of a control and communications structure governing mode dependent signal processing tasks.

Gray, D. M.↗

User's guide to noise data acquisition and analysis programs for HP9845: Nicolet analyzers

A software interface package was written for use with a desktop computer and two models of single channel Fast Fourier analyzers. This software features a portable measurement and analysis system with several options. Two types of interface hardware can alternately be used in conjunction with the software. Either an IEEE-488 Bus interface or a 16-bit parallel system may be used. Two types of storage medium, either tape cartridge or floppy disc can be used with the software. Five types of data may be stored, plotted, and/or printed. The data types include time histories, narrow band power spectra, and narrow band, one-third octave band, or octave band sound pressure level. The data acquisition programming includes a front panel remote control option for the FFT analyzers. Data analysis options include choice of line type and pen color for plotting.

Mcgary, M. C.↗

Demonstration Advanced Avionics System (DAAS) function description

The Demonstration Advanced Avionics System, DAAS, is an integrated avionics system utilizing microprocessor technologies, data busing, and shared displays for demonstrating the potential of these technologies in improving the safety and utility of general aviation operations in the late 1980's and beyond. Major hardware elements of the DAAS include a functionally distributed microcomputer complex, an integrated data control center, an electronic horizontal situation indicator, and a radio adaptor unit. All processing and display resources are interconnected by an IEEE-488 bus in order to enhance the overall system effectiveness, reliability, modularity and maintainability. A detail description of the DAAS architecture, the DAAS hardware, and the DAAS functions is presented. The system is designed for installation and flight test in a NASA Cessna 402-B aircraft.

Bailey, A. J.↗

Networking DEC and IBM computers

Local Area Networking of DEC and IBM computers within the structure of the ISO-OSI Seven Layer Reference Model at a raw signaling speed of 1 Mops or greater are discussed. After an introduction to the ISO-OSI Reference Model nd the IEEE-802 Draft Standard for Local Area Networks (LANs), there follows a detailed discussion and comparison of the products available from a variety of manufactures to perform this networking task. A summary of these products is presented in a table.

Mish, W. H.↗

High voltage design guide. Volume 4: Aircraft

This report supplies the theoretical background and design techniques needed by an engineer who is designing electrical insulation for high-voltage, high-power components, equipment, and systems for aircraft. A literature survey and abundant bibliography identify references that provide further data on the subjects of partial discharges, corona, field theory and plotting, voids and processes for applying insulation. Both gaseous and solid insulations are treated. Cryogenic and liquid design notes are included. Tests and test equipment for high voltage insulation and equipment are defined. Requirements of test plans and procedures for high-voltage, high-power equipment are identified and illustrated by examples. Suggestions for high-voltage specifications are provided. Very few of the Military and Government specifications deal with system voltages above 10kV, thus most aircraft high-voltage specifications will have to be derived from the power industry specifications and standards produced by ASTM, IEEE, and NEMA.

W G Dunbar↗

Spectroradiometric calibration of the thematic mapper and multispectral scanner system

The results of an analysis that relates thematic mapper (TM) saturation level to ground reflectance, calendar date, latitude, and atmospheric condition is provided. A revised version of the preprint included with the last quarterly report is also provided for publication in the IEEE Transactions on Geoscience and Remote Sensing.

Palmer, J. M.↗

Digital temperature and velocity control of mach 0.3 atmospheric pressure durability testing burner rigs in long time, unattended cyclic testing

Hardware and software were developed to implement the hybrid digital control of two Jet A-1 fueled Mach 0.3 burners from startup to completion of a preset number of hot corrosion flame durability cycle tests of materials at 1652 F. This was accomplished by use of a basic language programmable microcomputer and data aquisition and control unit connected together by the IEEE-488 Bus. The absolute specimen temperature was controlled to + or - 3 F by use of digital adjustment of the fuel flow using a P-I-D (Proportional-Integral-Derivative) control algorithm. The specimen temperature was within + or - 2 F of the set point more than 90 percent of the time. Pressure control was achieved by digital adjustment of the combustion air flow using a proportional control algorithm. The burner pressure was controlled at 1.0 + or - 0.02 psig. Logic schemes were incorporated into the system to protect the test specimen from abnormal test conditions in the event of a hardware of software malfunction.

Deadmore, D. L.↗

Studies on the Processing Methods for Extraterrestrial Materials

The literature was surveyed for high temperature mass spectrometric research on single oxides, complex oxides, and minerals in an effort to develop a means of separating elements and compounds from lunar and other extraterrestrial materials. A data acquisition system for determining vaporization rates as a function of time and temperature and software for the IEEE-488 Apple-ORTEC interface are discussed. Experimental design information from a 1000 C furnace were used with heat transfer calculations to develop the basic design for a 1600 C furnace. A controller was built for the higher temperature furnace and drawings are being made for the furnace.

Grimley, R. T.↗