Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IEC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

105 records · Page 6

Alignment and Testing of Critical Interface Fixtures for the James Webb Space Telescope

NASA's James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Primary Mirror Backplane Support Structure (PMBSS) and Integrated Science Instrument Module (ISIM) Electronics Compartment (IEC) which is designed to integrate to the spacecraft bus via six cup/cone interfaces. Prior to integration to the spacecraft bus the JWST observatory must undergo environmental testing, handling, and transportation. Multiple fixtures were developed to support these tasks including the vibration fixture and handling and integration fixture (HIF). This work reports on the development of the nominal alignment of the six interfaces and metrology operations performed for the JWST observatory to safely integrate them for successful environmental testing.

technology development↗

Alignment and Testing of Critical Interface Fixtures for the James Webb Space Telescope

NASAs James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy. The JWST Observatory architecture includes the Primary Mirror Backplane Support Structure (PMBSS) and Integrated Science Instrument Module (ISIM) Electronics Compartment (IEC) which is designed to integrate to the spacecraft bus via six cupcone interfaces. Prior to integration to the spacecraft bus the JWST observatory must undergo environmental testing, handling, and transportation. Multiple fixtures were developed to support these tasks including the vibration fixture and handling and integration fixture (HIF). This work reports on the development of the nominal alignment of the six interfaces and metrology operations performed for the JWST observatory to safely integrate them for successful environmental testing.

instrument development↗

Continuous Electrode Inertial Electrostatic Confinement Fusion

The NIAC Phase I project on Inertial Electrostatic Confinement was a continuation of early stage research that was funded by an NSTRF. The student on the project, Andrew Chap, was funded by the NSTRF from Fall 2013 through the Summer of 2017, and then was funded on the NIAC through the completion of his PhD. A significant amount of work targeting the plasma confinement physics was the focus of his NSTRF, and over the course of that effort he developed a number of analyses and computational tools that leveraged GPU parallelization. A detailed discussion of these models can be found in his dissertation, which has been included as Appendix D in this report. As a requirement for the NSTRF, Andrew's full dissertation was submitted at the end of the program.Having developed the computational tools, a substantial amount of simulation and analyses leveraging those tools were conducted during the Fall of 2017, under the auspices of the NIAC funded research. Much of this work targeted optimization of the confinement fields, investigating their structure and the possible advantages of having them be time-varying. The results of these simulations can also be found in Appendix D.One of the main results from this research is that the density of ions electrostatically confined within the system can indeed be increased by several orders of magnitude by optimizing the radial potential distribution, and by dynamically varying these fields to maintain compressed ion bunches. An electron population can also be confined within the core by a static radial cusped magnetic field,which helps to support a greater ion density within the core. The issue with the confinement mechanism is that as the ion densities are increased toward fusion-relevant levels, the electrostatic forces generated by the confined electron population become so great that the ions are no longer energetic enough to leave the device core. As their excursions into the outer channels are diminished, the mechanism that is used to maintain their non-thermal velocity distributions becomes ineffective, and eventually the ions become fully confined within the core, where they thermalize. A possible fix to the problem comes by discarding the active ion control (a main pillar of the concept)but retaining the structure of the permanent magnet confinement of the electron population. Such cusped field confinement has been the focus of other IEC approaches (e.g. Polywell), but the high transparency of the permanent magnet structure lends itself to better ion extraction and power conversion (a second pillar of the concept). The question then becomes whether any influence on the ion evolution within the core can be achieved to slow the thermalization of the ions. Such approaches have been studied in highly idealized analytic models, but face major criticisms within the literature. While this is a possible path forward, the uncertainty in the approach did not warrant committing NIAC Phase II resources to investigating the concept at this time.

Sedwick, Raymond↗

Screen-Printed Complex Ag Inks for Si HJT Metallization

Metallization using reactive metal inks has recently attracted significant research interest due to its advantages in cost of materials and manufacturing, while still achieving performance comparable to traditional fire-through particle pastes. Here, we present for the first time the use of reactive silver (Ag) inks via industrial screen-printing and inkjet printing methods for the metallization of different Si surfaces used in tunneling oxide passivating contacts (TOPCon) and Silicon heterojunction (SHJ) solar cells. Printed Ag lines exhibit a conductivity of ~5 Mu O·cm, which is approximately 3 times that of bulk Ag (1.59 µO·cm). The printed metal has a thickness of ~0.5-1.5 Mu m, an order of magnitude smaller than the current fire-through metal finger thickness (~15 Mu m). Contact resistivity measurements of the screen-printed and inkjet-printed samples on a transparent conducting oxide (TCO) surface show a very low value of ~0.2-12 mO·cm 2. Photoluminescence images of the metallized samples demonstrate minimal surface passivation degradation compared to the non-metallized areas (?iVoc <3.5 mV). Scanning electron microscopy images (SEM) reveal the structure of the printed metals on the Si surfaces as porous but much denser than fire-through Ag by nanoparticle paste. In the final presentation, we will showcase our results of printing these reactive Ag inks on high-efficiency heterojunction and TOPCon solar cells with full-area M6 wafers. Additionally, the adhesion of these reactive Ag inks on different Si surfaces according to ASTM D3359-17, as well as the performance of solar cells after standard IEC 61215 freeze/thaw and damp heat tests, will be presented. These new metal inks show promising potential as an alternative to the currently dominant particle-based pastes, offering lower Ag consumption and lower processing temperatures without compromising performance.

heterojunction solar cells↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Island influences on plant functional traits and trait–trait associations across species‐ and community‐scales

The island rule predicts gigantism or dwarfism in body size of island species relative to their mainland counterparts. However, whether other functional traits shift and whether trait–trait associations on islands differ between species and community levels remains unclear. We measured 13 carbon- and water-related functional traits in 37 shared tree species across 35 eastern Chinese islands and 66 nearby mainland plots. We examined species-level trait value shifts and associations under the island rule and compared trait associations between species and communities. Most size-related, wood-anatomical, and hydraulic traits shifted on islands, with large values decreasing and small values increasing; yet, their associations remained stable, aligning with the global trait spectrum and trait–trait coevolution. This stability, despite trait value shifts, suggests evolutionary integration of functional strategies. By contrast, island community-scale trait associations diverged from shared species-level patterns and sometimes reversed, such as positive relationships between wood density and resource-acquisitive traits. Community-level trait associations were stronger on islands, likely reflecting constrained environmental filtering and migration limitation. These contrasting patterns suggest that dominant species can restructure trait associations at the community level, with implications for ecosystem functioning and carbon storage, thereby advancing understanding of plant trait strategies in island systems.

Archipelagos↗

Semi‐Volatile Organic Partitioning Improves Simulation of Biomass Burning Aerosol Mixing State Evolution

Biomass burning aerosols significantly contribute to atmospheric composition and radiative forcing, with black carbon (BC) mixing states critically influencing optical properties and climate impacts. Recent field observations reveal a systematic three‐phase evolution in BC coating thickness during plume aging: rapid initial growth, quasi‐equilibrium, and gradual coating loss. Current models misrepresent this evolution due to oversimplified treatment of organic aerosol volatility. Here we demonstrate that incorporating semi‐volatile organic partitioning through the MATRIX‐VBS model fundamentally improves simulation accuracy compared to traditional non‐volatile approaches. Evaluation against four field campaigns spanning fresh to aged plumes shows MATRIX‐VBS successfully captures the observed three‐phase pattern, and global application reveals universal three‐phase evolution with substantial regional variations. These advances address critical gaps in aerosol mixing state representation and provide essential improvements for climate model predictions in wildfire‐affected regions.

Gao, Chloe Yuchao [Fudan Univ., Shanghai (China); ↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

BACKFLIP: A Comparison of Market-Benchmark Backsheet Technologies to Novel Non-Fluoro-Based Coextruded Materials and Their Correlation and Impact on PV Module Degradation Rates: Final Results of the Study at 4000 Hours or 2 Years

As the photovoltaic (PV) industry is rapidly expanding around the world, there has been an increasing interest in extending the lifespan of PV modules. Concern has also emerged regarding the recyclability of modules and their component materials, including fluoropolymer-based backsheets. Laminated polyethylene-terephthalate (PET) core backsheets have traditionally been used in the PV industry, but new, co-extruded polyolefin (PO) backsheets show promise as an improved alternative. Mini-module and coupon samples of seven different backsheets (made of layers including contemporary PET and fluoropolymers, novel PO, and polyamide (PA) materials) were run through hygrometric- or UV photolytic-accelerated aging to identify and better understand each material's degradation modes and the backsheets' field reliability. In addition to the artificial aging, the natural weathering methods used in this study are described. The comprehensive set of chemical, mechanical, and structural characterizations at intermittent read points in this study is presented, including: visual appearance and color; gloss; mechanical tensile testing; I-V performance; electroluminescence (EL) imaging; dielectric breakdown; FTIR-chemical structure; X-ray-polymer structure (WAXS); and DSC-crystalline content. After 4000 h of accelerated aging or 2y of outdoor aging, a strong correlation occurs between initial physical characteristics (mechanical tensile test) and operating performance (EL and I-V characteristics).

14 SOLAR ENERGY↗

Introduction to Microgrids

A microgrid is simply a typical power system that has distributed energy resources (DERs), like small diesel generators, with loads in the network. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. One key factor that differentiates microgrids from a typical distribution grid is its ability to disconnect itself in the event of a blackout and sustain its loads through DERs. Microgrid systems will reconnect to the main grid when the grid comes back up. The resiliency offered by microgrids to retain service during system events makes them a suitable support for the electric grid during natural disasters. This presentation discusses the typical key steps involved in microgrid planning, installation, operation in a interoperable and interconnectable fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL's Facilities are ISO 17025 Accredited!

This fact sheet covers what accredited testing is. It highlights the value add of accredited testing. It also describes the types of testing NREL is accredited for in marine energy.

accredited testing↗

Working with Us

NREL is focused on the long-term impact that strategic partnerships can have on energy research and development, grid security and resilience, the U.S. economy, and Americans' lives. NREL works with commercial and noncommercial entities, including national security and defense partners, national laboratories, and research institutions to advance foundational research and development - pushing the boundaries of scientific discovery and accelerating breakthroughs in energy innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ON THE EFFECTIVENESS OF LLMS IN UNIT TEST GENERATION FOR STRUCTURED TEXT PROGRAMS

The reliability of industrial automation systems heavily depends on the correctness of Programmable Logic Controller (PLC) programs, which are often written in Structured Text (ST). While Large Language Models (LLMs) have shown promise in automating test generation for mainstream programming languages, their effectiveness for the syntactically strict ST language remains underexplored. This thesis presents a systematic empirical evaluation of three state-of-the-art LLMs—GPT-4o, Gemini 2.5 Pro, and Claude Sonnet 4.5—for generating ST unit tests. We examine three prompting strategies: Natural Language (NL), Code Language (CL), and Chain-of-Thought (CoT), across a curated set of 11 ST function blocks. The quality of the generated tests is assessed using Compilation Success Rate (CSR), Statement Coverage (SC), and Branch Coverage (BC). In the zero-shot setting, Claude Sonnet 4.5 achieves the highest CSR, while Gemini 2.5 Pro consistently delivers the best statement and branch coverage, particularly under CL prompts. By incorporating a one-shot CL prompt, all models exhibit substantial improvements—most notably GPT-4o, whose CSR increases from 45.45% to 90.91%, with substantial gains in both SC and BC. To further contextualize these findings, we compare GPT-4o’s one-shot results with PLCAutoTester, a state-ofthe- art ST unit test generation tool, on an additional benchmark dataset. While LLMgenerated tests approach competitive coverage levels, PLCAutoTester maintains significantly higher and more stable coverage across programs. This study provides the first comprehensive benchmark of modern LLMs for ST unit testing, highlighting their strengths, limitations, and improvements through one-shot prompting, and positioning their performance relative to specialized automated testing tools in industrial automation.

42 ENGINEERING↗