Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICSBEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Understanding the impact of nuclear-data covariances on various integral responses using adjustment

The EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project created a library of sensitivities for nine different integral responses with respect to nuclear data. These integral responses were obtained from measurements at LLNL (Lawrence Livermore National Laboratory) pulsed spheres, critical and sub-critical assemblies. At the same time, covariances for ENDF/B-VIII.0 were processed at LANL (Los Alamos National Laboratory). The combination of these data allow us to study the impact of nuclear-data covariances on various integral responses, either by forward-propagating covariances via sensitivities, or by using nuclear data, integral responses, and sensitivities for adjustment. Here, we will present: the impact of 1 H, 9 Be, 12 C, 27 Al, 56 Fe, 235,238 U, and 239,240 Pu ENDF/B-VIII.0 covariances on simulated bounds of the following integral responses: LLNL pulsed-spheres neutron-leakage spectra, the effective neutron multiplication factor, reaction rates, and reactivity coefficients of ICSBEP critical assemblies. Also, adjustment results with the same nuclear-data covariances and responses will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Producing Evaluation-quality 239 Pu Average Prompt Fission Neutron Multiplicities using a Correlated Fission Model

An evaluation of the average prompt fission neutron multiplicity, $\bar{ν}_p$, of 239 Pu(n,f) is shown. This evaluation includes (a) the correlated fission model CGMF, and (b) a detailed analysis of past and recently published experimental data. Using CGMF-calculated $\bar{ν}_p$ as prior enables to link, through the use of evaluated model input parameters, $\bar{ν}_p$ to other fission observables such as the prompt fission neutron spectrum (PFNS), preneutron emission fission yields as a function of mass, and the average total kinetic energy of the fragments. These evaluated parameters produce realistic predictions of many fission observables, while the evaluated $\bar{ν}_p$ agrees well (χ 2 ≈ 1) with data. Moreover, with the new evaluated $\bar{ν}_p$, the effective neutron multiplication factor of fast Pu ICSBEP critical assemblies are predicted with a mean bias of 58 pcm compared to 18 pcm with ENDF/B-VIII.0, when paired with a new 239 Pu PFNS and fission cross section. Due to these encouraging validation results, the evaluated $\bar{ν}_p$ is currently part of a release candidate for the 239 Pu ENDF/B-VIII.1 file. Hence, a correlated fission model was used for the first time for evaluating $\bar{ν}_p$ that is of evaluation quality. This is an important step towards consistent evaluations of prompt fission observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data?

Nuclear data are used for a variety of applications, including criticality safety, reactor performance, and material safeguards. Despite the breadth of use-cases, the effective neutron multiplication factor, keff, of ICSBEP critical assemblies are primarily used for nuclear data validation; these are sensitive to specific energy regions and nuclides and are unable to uniquely constrain nuclear data. As a consequence, general-purpose nuclear data libraries, such as ENDF/B-VIII.0, may have deficiencies that, while not apparent in criticality applications, negatively impact other applications, such as non-destructive analysis of special nuclear material and neutron diagnosed subcritical experiments. Recent work by the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project developed a machine learning tool, RAFIEKI, which uses random forests and the SHAP metric to determine which nuclear data contribute most to predicted bias between measured and simulated responses (e.g. keff). This paper contrasts RAFIEKI analysis applied to keff only against RAFIEKI analysis with keff paired with either LLNL pulsed sphere measurements or subcritical benchmarks. Two examples show that a) including pulsed sphere measurements substantially increases 9Be nuclear data importance to bias between 2 and 15 MeV, and b) including subcritical benchmarks has the potential for disentangling compensating errors between 240Pu (n,el) and (n,il) cross-sections between 0.1 and 10 MeV. These results show that RAFIEKI analysis applied to response sets that include, but go beyond, keff can aid nuclear data evaluators in identifying issues in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Covariance Determination for Critical Integral Experiments

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. In general, uncertainty quantification techniques ignore correlations between experiments and shared parts. Experiments, such as the TEX (Thermal/Epithermal eXperiments) campaigns, consist of many shared parts, such as the ‘Jemima’ HEU fuel plates, which create a strong correlation in their uncertainties. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes an intuitive method of determining the covariance for each of the experimental components, providing a correlation for each family of parts across the multiple cases examined within a benchmark. A proof-of-principle study using the TEX-HEU experimental campaign was performed and verified that the correlations can be calculated with information commonly found in the ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. This study showed that the introduction of model and experimental covariances reduces the χ 2 per degree of freedom from 2.203 to 1.179, indicating that the omission causes overly pessimistic bias quantifications. This technique can be seamlessly integrated to current benchmark evaluations as well as reevaluations of legacy benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expanded Intercomparison of Nuclear Data Libraries Using Jupiter and Jupiter High-240 Experiments

There is a limited availability of plutonium experiments with sensitivity to lead in the ICSBEP (International Handbook of Evaluated Criticality Safety Benchmark Experiments) Handbook. The Jupiter and Jupiter High-240 experiments were performed at the National Criticality Experiments Research Center as a collaborative effort between Los Alamos National Laboratory and the Japan Atomic Energy Agency to assess lead void coefficients in a plutonium-lead system containing weapons- and reactor-grade plutonium, respectively. Concurrent with benchmark development, an intercomparison of calculations using different nuclear data libraries has been performed to assess the usability of the experimental data for nuclear data adjustment in a “softer-that-fast” neutron energy spectrum. Eigenvalue calculations using MCNP with the ENDF/B-VIII.0 and TENDL-2021 nuclear data libraries calculate closest to the benchmark values for Jupiter. Calculations using JENDL-5 and ENDF/B-VIII.1 match best with the Jupiter High-240 values. Lead void worth calculations using the various nuclear data libraries are all within 3σ of their respective measured values. Perturbation studies between ENDF/B-VIII.0 and ENDF/B-VIII.1 demonstrate an approximate increase in calculated eigenvalues for the Jupiter series experiments by ~240 pcm for plutonium (mostly 239 Pu) and ~120 pcm for lead accompanied by a decrease contributed by ~113 pcm for copper and ~13 pcm for stainless steel. Nuclear data sensitivities and uncertainties investigated using Whisper show slightly lower sensitivity to scatter than a lead-reflected plutonium sphere but greater sensitivity to neutron capture. The sensitivities between Jupiter and Jupiter High-240 for lead are very similar for both ENDF/B-VIII.0 and ENDF/B-VIII.1 nuclear data. These benchmarks are more sensitive to neutron capture in lead than other plutonium benchmark experiments and would be useful for both lead and 240 Pu validation. In conclusion, with the high degree of compensating effects between copper, lead, and plutonium cross sections, additional isolated Pb-Pu and Cu-Pu benchmarks would be beneficial in improving these nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of the KRUSTY Benchmark Modeling and Uncertainty Analysis

The U.S. National Aeronautics and Space Administration’s (NASA) desire for a small nuclear reactor for space applications led to a prototype assembly, Kilopower Reactor Using Stirling Technology (KRUSTY). The KRUSTY experiments included four phases: component critical, cold critical, warm critical, and high temperature. The KRUSTY benchmark described in this paper includes five configurations from the component critical experiments that were performed at the National Criticality Experiments Research Center (NCERC) beginning in November 2017. Preliminary results have been reported. The benchmark is now nearing completion (although it is still preliminary until formally accepted by the International Criticality Safety Benchmark Evaluation Project [ICSBEP] working group). In this paper, we present the updated benchmark and its uncertainties. These results were computed using MCNP6.2 ® with ENDF/B-VIII.0 cross sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

S/U Comparison Study with a Focus on USLs

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize ENDF/B-VII.1. Four cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) were selected as application models: HEU-MET-FAST-013-001, HEU-SOL-THERM 001-008, PU-MET-FAST-022-001, and PU-SOL-THERM 001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL may be computed using bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS 8.24. Application of portions of MOS to the USL for nuclear data uncertainty of and potential code margin is referred to as USL herein. In either case, additional MOS is considered for actual application cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sandia 7uPCX Critical Experiments Exploring the Effects of Fuel-to-Water Ratio Variations

The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The LEUCOMP-THERM-078 and LEU-COMP-THERM-080 evaluations from the handbook provide similar cases for reference. The set of experiments described here were performed using the Seven Percent Critical Experiment (7uPCX) fuel to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by using fuel loading patterns to effectively increase the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discovery of AMPX Thermal Scattering Law Processing Issue for Solid Moderators

The 2020 edition of The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook includes a newly produced plastic-moderated evaluation, identified as PU-MET-MIXED-002 and referred to as PMM002. The 2021 edition should include another new plastic-moderated experiment, HEU-MET-THERM-004, referred to as HMT-004. These evaluations are of particular interest, as PMM-002 is moderated with polyethylene, and HMT-004 is moderated with polymethyl methacrylate (Lucite), allowing for investigation of the differences in the thermal scattering laws (TSLs) available for these materials. ENDF/B-VIII.0 includes newly produced data for 1 H-based scattering materials, including Lucite and yttrium hydride. Other available 1 H TSLs include polyethylene, light water, zirconium hydride. The unbound 1 H (free-gas) cross sections were also used. ENDF/B-VIII.0 also includes revisions made to the ENDF/B-VII.1 light water and polyethylene evaluations. Zirconium hydride was unchanged from ENDF/B-VII.1. As of this writing, there are no benchmarks included in the Verified, Archived Library of Inputs and Data (VALID) that are primarily moderated with any solid moderator, so validation that includes the PMM-002 and HMT-004 evaluations would expand the coverage to two new moderators. A study was undertaken at Oak Ridge National Laboratory with two purposes: to provide validation data based on systems that are primarily moderated with polyethylene and Lucite, and to demonstrate the reactivity changes that can result from use of different 1 H TSLs in these plastic-moderated systems. The first objective was mainly to test data and code for SCALE and AMPX, whereas the second objective was to provide useful data for practitioners on the potential variability of predicted $k_{eff}$ based on TSL changes. The use of an exactly correct TSL is often not possible given the materials involved (e.g., lubricants), but this study was intended to provide some indication of the magnitude of the changes among similar materials that can manifest through application of different TSLs in hydrogenous systems over a range of different neutron energy spectra. Unfortunately, the nominal $k_{eff}$ results exposed deviations between SCALE and Monte Carlo N-Particle (MCNP). Some of the results using different TSLs were also unexpected and difficult to explain. An investigation revealed a processing issue in AMPX that was caused by an ambiguous description of the data for incoherent elastic scattering in the ENDF manual. This issue is discussed in detail in a SCALE User Notification, and it affects some solid moderators, but it does not apply to 1 H bound in water. This issue highlights the importance of validating all TSLs used in safety analysis calculations. The remainder of this paper provides a more detailed examination of the results that triggered the investigation and a summary of the findings of that investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of Temperature Dependent Critical Experiments with SPRF/CX

This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories (Sandia). The goal of these experiments is to test the effect of varying system temperature on the $\kappa$ eff bias of water-moderated systems. Temperatures of 5–95°C were considered in this work. Eighteen representative lattice configurations were analyzed that had variations in the number of fuel rods and water holes, as well as in the array configuration, to achieve a variety of moderation regimes. The configurations were based on those detailed in the LEU-COMP-THERM-078 and LEU- COMP-THERM-079 experiments, both of which were published in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity-based Similarity Metrics for New Experiment Design Optimization

The nuclear data used in advanced reactor simulations requires validation. Data from nuclear criticality experiments can provide this validation. New nuclear criticality experiment design requires extensive knowledge and expert judgement such that the experimental design parameters are selected in such a way to keep the experiment subcritical. To aide in this experimental design process, professionals can utilize sensitivity and uncertainty analysis. Sensitivity and uncertainty analysis relies on matching new application experiments with currently existing benchmark experiments. Currently, there is functionality in the Whisper 1.1 software package to calculate a similarity metric based on neutron multiplication factor sensitivity coefficients between a new application designed by the user and existing International Criticality Safety Benchmark Experiment Project (ICSBEP) benchmarks. The Whisper 1.1 software package is included in Monte Carlo N-Particle ® Code Version 6.21 (MCNP ® 6.2). This work is geared toward expanding this capability to new similarity metrics based on beta-effective sensitivity coefficients and reactivity coefficient sensitivity coefficients. While the investigation of these sensitivity coefficients is presented in detail in separate works at this same conference, this work will be primarily focused on studying the similarity metrics in more detail. These similarity metrics will then be incorporated into the optimization algorithms used for experiment design in EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data), which is a Los Alamos National Laboratory (LANL) project designed to constrain nuclear data of interest, such that adjustments can be made to possible inaccuracies. A more detailed optimization can be subsequently performed by breaking down these similarity metrics by isotope, reaction, and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools Case Studies of Benchmarks and Applications

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP ® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. The initial comparison involves four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been: 1. modeled independently by LANL, IRSN, and ORNL based upon information provided in the ICSBEP Handbook, 2. are common in S/U libraries for LANL, IRSN, and ORNL, 3. span a range of energy spectrum and fissile material, and 4. taken as applications for the purposes of this study and therefore excluded from use as a benchmark for calculating the upper subcritical limit. Results presented in this paper have been computed using covariance data for all isotopes in ENDF/BVII.0 using a 44-group energy structure. Benchmarks in the Whisper library were run in MCNP6.2 using 100,000 neutrons per cycle, skipping 100 cycles for 500 active cycles. Reference 10 also compares the results for baseline USL with an order of magnitude greater neutrons, using the same total number of cycles with 1,000,000 neutrons per cycle. Subsequent to the results presented in Reference 10 changes were made to the benchmark library, as discussed in Reference 11. Newer results using the revised benchmark library are presented herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

(U) Archive of Historic Pu-239 Jezebel Documents

The 239 Pu Jezebel experiment of 1954–1955 was reevaluated for the 2013 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. Experimental logbooks, original drawings, mass accountability statements, internal reports, and published reports were used to model four actual Jezebel assemblies with high fidelity in three dimensions. Because plutonium-alloy part masses from 1954–1955 (the time of the original experiments) were not found, assumptions were made. The most important assumption was that the assembly masses given in Los Alamos report LA-4208 (Ref. 3) in 1969 were correct. With this basic assumption, and using information found in the logbooks and mass accountability statements from 1958–1960, a distribution of the LA-4208 assembly mass among the Pu-alloy parts was postulated. Subsequently, the SF Material Transfer Receipt (November 24, 1954) was found. It lists the masses of the major parts and several minor parts as of late-November 1954. In addition, as-built drawings for the initial delivery of the major parts (October 1954, before they were remachined to reduce their reactivity) were found. These important documents, which were discovered by accident, motivated what we hope will be the final detailed Jezebel reevaluation.

36 MATERIALS SCIENCE↗

Whisper Use of Nuclear Data Covariances [Slides]

Whisper is statistical analysis code using sensitivity/uncertainty-based methods to determine baseline upper subcritical limit (USL) for nuclear criticality safety. Features of Whisper 1.1 include: GLLS method implemented to compute adjusted covariance based on current benchmark suite (1,100+ ICSBEP models), BLO “low-fidelity” covariance data used (44 energy groups), adjusted covariance is pre-computed and saved, and adjusted cross sections are NOT computed. Potential future efforts include: an extension to include angular distributions in benchmark selection and in GLLS adjustment, a move toward more modern covariance data (ENDF/B-VIII.0) and different group structure, and compute and store adjusted cross sections (trivial).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Including Chi-Nu 235 U PFNS Experimental Data into an ENDF/B-VIII.1 Release Candidate Evaluation

This report documents an evaluation of 235 U prompt fission neutron spectra (PFNS) that is a release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation differs from its predecessor, ENDF/B-VIII.0, mainly by the inclusion of 235 U PFNS measured by the Chi-Nu team of LANL and LLNL. This data set is the first one that covers the 235 U PFNS for continuous incident-neutron energies of 1⁻20 MeV and outgoing-neutron energies from 10 keV⁻10 MeV with high precision. Previous data sets were either measured in a limited energy range or with less precision. Hence, these new Chi-Nu data provide decisive information for the evaluation. The resulting evaluated data correspond well to the new experimental PFNS. The evaluated PFNS also produce average mean energies and 239 Pu/ 235 U PFNS in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, the differences of simulated values compared to those using ENDF/B-VIII.0 is modest (less than 55 pcm). This difference in k eff can be easily accommodated by changes in the 235 U average prompt fission neutron multiplicity that is currently being re-evaluated. In addition to that, the new PFNS predict on average 235 U LLNL pulsed-sphere neutron-leakage spectra better than ENDF/B-VIIII.0 PFNS.

235U↗