Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Gas-phase ion-molecule interactions in a collision reaction cell with triple quadrupole-inductively coupled plasma mass spectrometry: Investigations with N 2 O as the reaction gas

Nitrous oxide (N 2 O) was used as a reaction gas to investigate the gas phase ion-molecule interactions using the Agilent 8900 QQQ-ICP-MS. A multi-element standard containing 45 elements with masses ranging from 9 to 208 u was measured in the presence and absence of N 2 O. The main product ion species observed were oxides and nitrides. Comparison of the N 2 O reaction results with similar measurements conducted with O 2 revealed that N 2 O was more effective at forming oxides in general: the elements Cd and Pb were shown to produce oxides with N 2 O where the reaction did not occur with O 2 . Nitrous oxide was also shown to produce a significant amount of nitride species in a few cases. The general reactivity was shown to be consistent with density functional theory (DFT)-predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels at least 1% of the unreacted ion. Our results show that reaction enthalpy is a reasonable predictor of reactivity with N2O on the timescales of the interactions in non-thermal ICP-MS/MS systems. Our work demonstrates the utility of two relatively new platforms (commercial elemental ICP-MS/MS and EMSL Arrows interface to the NWChem program suite), which allows for the study of a large number of elements within a short period. While DFT with the basis sets utilized here is not the most accurate computational method, it is also not computationally expensive and is shown to be suitable for predicting gas phase reactivity in the QQQ-ICP-MS for the majority of ions studied. Here, the ease and rapidity of data collection and DFT calculations has the potential to be very impactful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-line Inductively Coupled Plasma Mass Spectrometry Reveals Material Degradation Dynamics of Au and Cu Catalysts during Electrochemical CO 2 Reduction

A significant challenge in commercializing electrochemical CO 2 reduction (CO 2 R) is achieving catalyst durability. Here, in this study, online inductively coupled mass spectrometry (ICP–MS) was used to investigate catalyst degradation via nanoparticle detachment and/or dissolution into metal ions under CO 2 R operating conditions in 0.1 M KHCO 3 . We developed an experimental framework with ex situ characterization to validate the online ICP–MS method for in situ evaluation of degradation from metal foils. By varying the applied potential and microenvironment (CO 2 vs N 2 -saturated electrolyte), we gained insights into the degradation of Au and Cu foils under CO 2 R and hydrogen evolution reaction (HER) conditions. While both Au and Cu foils were observed to be stable to dissolution in these regimes, degradation via nanoparticle detachment from the foil surface at the femtogram scale was observed as a function of reaction conditions, providing new insights into material degradation mechanisms. When applying potential steps at −0.1 and −1.0 V vs the reversible hydrogen electrode (RHE), Au was found to degrade via nanoparticle detachment under CO 2 R operating conditions more than under HER conditions, while Cu was found to degrade via nanoparticle detachment in similar amounts during both reactions. Au lost ∼1.8× more mass and ∼7.5× more nanoparticles than Cu under CO 2 R operating conditions. This study demonstrates the use of online ICP–MS to gain insight into the degradation of Au and Cu, the importance of studying unconventional degradation mechanisms such as nanoparticle detachment, and that online ICP–MS can be further utilized to gain fundamental understanding of catalyst durability for a variety of reaction systems.

Yan, Katherine [Stanford Univ., CA (United States)↗

Fast Determination of Lithium Content in Spent Cathodes for Direct Battery Recycling

Determination of the lithium ion content in cathode materials, which is currently performed by inductively coupled plasma mass spectrometry (ICP-MS), involves tedious procedures and error-prone preparation. This work introduces a new methodology to quickly determine the lithium content in spent cathode materials (LiNix Mny Coz O2, x + y + z = 1, NMC) using a thermalgravimetric analysis, which bypasses the use of ICP-MS and significantly reduces the cost and time required for determining the lithium content. Based on this new method, a new approach is developed to identify spent cathode materials suitable for direct relithiation recycling. Finally, these new methods have been applied to investigate the effectiveness of direct electrochemical-relithiation on recycling the spent cathodes, and provide insights for future development of direct battery materials recycling.

cathode recycling↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Insights into Electrochemical Pre‐Treatments of Supported Nanoparticle Electrocatalysts by Combining a Design of Experiments Strategy with In Situ Characterization

Activation, break-in, and/or pre-treatment protocols are generally applied to energy conversion devices before regular operation to reach stable performance. There remains much to understand about the relationships among physical properties, performance, and electrochemical pre-treatments. Here, a design-of-experiments (DoE) strategy is employed to address this gap by demonstrating the influence of five pre-treatment parameters for carbon-supported Pt-nanoparticle catalysts on the electrocatalytic oxygen reduction reaction (ORR). A subset of pre-treatments, developed using a central composite design, are tested in a flow cell combined with an inductively-coupled plasma mass spectrometer (on-line ICP-MS). The DoE-based approach facilitates comprehensive insights from two orders of magnitude fewer experiments than a conventional grid search. The coupled on-line ICP-MS setup enables effective catalysis and real-time catalyst dissolution data. Leveraging insights from DoE for on-line ICP-MS and additional characterization, a model is built between the degradation of a multi-dimensional supported Pt surface, its performance, and applied electrochemical parameters. These investigations identify surface modifications, such as oxidation, and subsequent restructuring of Pt during pre-treatment as a primary cause of performance deterioration during ORR. By combining DoE with advanced characterization techniques, a powerful approach is demonstrated to gain a mechanistic understanding of pre-treatment protocols that can be broadly adapted to various reaction chemistries.

Platinum↗

The influence of water, diet, and temperature on 87 Sr/ 86 Sr in fin spines of juvenile Atlantic Sturgeon Acipenser oxyrinchus oxyrinchus

Analysis of microchemistry in fish fin spines offers a non-lethal approach to address key questions relating to spatial patterns and habitat use of fish. Reconstruction of life history is based on chemical changes within calcified structures with an underlying assumption of elemental incorporation relative to environmental concentration. However, information is limited on the relative influence of water and diet concentrations of elements to corresponding concentrations within fin spines. Strontium (Sr) is commonly used in trace element studies because of its predictable changes within watersheds, with recent applications showing utility of 87 Sr/ 86 Sr for greater spatial resolution. Therefore, this study evaluated the influence of water and diet 87 Sr/ 86 Sr on pectoral fin spines of Atlantic Sturgeon A. oxyrinchus oxyrinchus in controlled laboratory experiments. In the first experiment, fish were exposed to a control, water spiked with 0.10 mg/L of 87 Sr or diet spiked with 0.25 µg/g or 0.50 µg/g of 87 Sr in replicated tanks for 12 weeks. In a second experiment, to determine the time duration required to occupy a different environment for fin spine chemistry to change, fish were maintained in water- or diet-spiked treatments for 1, 2, 3, or 6 weeks. Additionally, to determine if temperature has an influence on 87 Sr/ 86 Sr in fin spines, fish were held at 15 and 25°C for 12 weeks. Fin spines were analyzed using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS), and water and diet samples were analyzed using solution based ICP-MS. Results from Experiment 1 indicate water is the primary contributor and diet a secondary contributor of 87 Sr/ 86 Sr in pectoral fin spines of Atlantic Sturgeon. Results from Experiment 2 indicate fin spine 87 Sr/ 86 Sr can be influenced by water after 1 week and diet after 12 weeks. Additionally, although sample size was limited (n=3), water temperature did not have an effect on 87 Sr/ 86 Sr fin spine chemistry. In conclusion, these results provide guidance for interpretation of 87 Sr/ 86 Sr in pectoral fin spines of sturgeon and indicate usefulness of the technique for retrospectively estimating movement and habitat use.

59 BASIC BIOLOGICAL SCIENCES↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plutonium Co-precipitation with Calcite

The mobility of plutonium (Pu) in the environment is affected by Pu–mineral interactions, such as adsorption–desorption and structural incorporation. Calcite (CaCO 3 ) is a common secondary phase in near surface environments and a major component of many rocks and soils and is expected to form as an alteration product of cement-based materials planned for use in geological repositories. The reactivity of the calcite surface and its ability to tolerate significant variations in its chemical composition through substitution of Ca for other cations make calcite a potentially important sink for environmental contaminants. Here, single crystals of calcite were synthesized from aqueous solutions in equilibrium with air containing Pu as either Pu(VI) or Pu(IV) and characterized using a combination of laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) and X-ray absorption spectroscopy (XAS). These data are used to assess the amount, structure, and oxidation state of Pu co-precipitated into calcite, providing insight into the potential for Pu sequestration in calcite precipitates. Overall, the XAS and LA–ICP–MS data support the co-precipitation of plutonyl [Pu(VI/V)] in the bulk calcite, although the exact nature of the co-precipitated Pu complex is difficult to elucidate in the synthesized material. Co-precipitated plutonyl could be incorporated in either distorted Ca lattice sites or defect sites, and we provide evidence to suggest that Pu(VI) is reduced mainly to Pu(V) in the precipitated solid. LA–ICP–MS additionally shows that the co-precipitation of Pu(VI/V) is favored over the co-precipitation of Pu(IV). Altogether, our results suggest that Pu sequestration in calcite under environmental conditions could immobilize Pu and isolate it from groundwater interactions in contaminated environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

High Pressure DME-Driven Fractional Crystallizations

Rare Earth Elements (REEs), include the 15 lanthanides plus yttrium and scandium and are crucial for various technologies and applications. Their low concentrations in the earth's crust require alternative sources. This study explores antisolvent fractional crystallization (FC) using dimethyl ether (DME) under high pressures to extract REEs from secondary sources such as mining waste, coal byproducts, and e-waste. DME's properties, including its solubility in water, small molecular size, and high vapor pressure, make it an effective antisolvent that can be easily recovered and reused. The method involves pressurizing DME to 1000-2000 psi in a reaction chamber with the test solution, followed by sample collection and analysis using ICP-MS and ICP-OES. This approach aims to address the limitations of current extraction methods, such as high energy consumption, chemical usage, and waste production, offering a potentially more efficient and sustainable solution for REE extraction.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Utilizing metal cation reactions with carbonyl sulfide to remove isobaric interferences in tandem inductively coupled plasma mass spectrometry analyses

Carbonyl sulfide (OCS) was used as a reaction gas to investigate gas phase metal (M + ) ion-molecule reactions using the Agilent 8900 inductively coupled plasma tandem mass spectrometer (ICP-MS/MS) to yield insight on how this gas may be used to remove isobaric interferences in analytical measurements. The experimental work was paired with density functional theory (DFT) calculations of the reaction enthalpy to predict whether M + will react with OCS. A multi-element standard containing 46 elements ranging from 9 to 208 u was analyzed in the presence and absence of OCS. When a reaction was observed, the dominant product was the sulfide (MS + ). Oxide products were also observed for many M + but formation was less efficient with OCS than previously observed with other reaction gases. This is likely due to the weaker OC-S bond that makes MS + formation more favorable. Increasing the flow rate from 0.1 to 0.2 mL/min (corresponding to a change in reaction gas pressure from 0.35 to 0.53 Pa (2.6 to 4.0 mTorr)) generally resulted in greater MS + production, including the secondary product MS 2 + for a few cations. The early lanthanide series ions (La + , Ce + , Pr + and Nd + ) produced greater quantities of MO + at the higher pressure, although MS + products were still the dominant product. The DFT-predicted reaction enthalpies were consistent with the observed sulfide formation, with an accuracy >90%; however, model predictions were less accurate for the minor and higher order products (< 77% for MO + ). Finally, the work presented here continues a systematic study of ion-molecule reactions in ICP-MS/MS to understand and develop new and novel ways to analyze complex mixtures with minimal pre-analysis treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation and determination of ultratrace rhenium quantities in molybdenum matrix

The production of very pure molybdenum, free of Re even at ultratrace levels, is extremely important in meeting target purity specifications during the production of 99 Mo for medical applications. Here we propose two methods for separating ultratrace levels of Re from a bulk Mo matrix using either solvent extraction or extraction chromatography, combined with inductively coupled plasma quadrupole mass spectrometry (ICP-MS) detection. Re is extracted (D > 70) from solutions in sulfuric acid as a complex with tri-n-butyl phosphate. Scrubbing and washing steps result in total decontamination factors for Mo up to 1,700 for solvent extraction and 3,500 for extraction chromatography. Re is stripped into a 3 M NH 4 OH matrix and analyzed by ICP-MS. Detection (L D ) and quantification (L Q ) limits were optimized by matrix-matching to allow detection of Re in strip solutions at levels of L D = 0.1 ng Re/g-Mo and L Q = 0.3 ng Re/g-Mo in Mo powder samples. By employing these two extraction methods, excellent recoveries of Re from bulk Mo are achieved, and the L Q is improved by a factor of 5 x 10 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Stability of Manganese Chromium Antimonate Electrocatalysts through Multimodal In Situ and Operando Measurements

Herein, we utilize an on-line electrochemical flow cell coupled with an inductively coupled plasma-mass spectrometer (ICP-MS) to characterize the impact of composition and reactant gas on the multielement dissolution of Mn(-Cr)-Sb-O electrocatalysts. Compared to Mn 2 O 3 and Cr 2 O 3 oxides, we find that the antimonate framework stabilizes Mn at OER potentials and Cr at both ORR and OER potentials. Furthermore, dissolution of Mn and Cr from Mn(-Cr)-Sb-O is found to be driven by ORR reaction rate, with minimal dissolution under N 2 . We observe preferential dissolution of Cr totaling 13% over 10 minutes at 0.3, 0.6, and 0.9 V vs RHE, with only 1.5% loss of Mn, indicating an enrichment of Mn at the surface of the particles. Despite this asymmetric dissolution, in situ X-ray absorption spectroscopy (XAS) showed no measurable changes in the Mn K-edge at comparable potentials. This lack of change could suggest that modification to the Mn oxidation state in the surface layer is too small or that layer is too thin to be measured with the bulk XAS measurement. Lastly, on-line ICP-MS was used to assess the effects of applied potential, scan rate, and current of Mn-Cr-Sb-O during cyclic voltammetry and accelerated stress tests. With this deeper understanding of the interplay between oxygen reduction and dissolution, testing procedures were identified to maximize both activity and stability. This work highlights the use of multi-modal in situ characterization techniques in tandem to build a more complete model of stability and develop protocols for optimizing catalyst performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗