Autonomous Cryogenic Leak Detector for Improving Launch Site Operations

NASA, military, and commercial satellite users need launch services that are highly reliable, less complex, easier to test, and cost effective. This project has developed a tapered optical fiber sensor for detecting hydrogen. The invention involves incorporating chemical indicators on the tapered end of an optical fiber using organically modified silicate nanomaterials. The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and qualify various mission-critical chemicals. Historically, hydrogen, helium, nitrogen, oxygen, and argon are the first five gases of HGDL focus. The use of these cryogenic fluids in the area of propulsion offers challenges. Due to their extreme low temperatures, these fluids induce contraction of the materials they contact, a potential cause of leakage. Among them, hydrogen is of particular concern. Small sensors are needed in multiple locations without adding to the structural weight. The most vulnerable parts of the engine are the connection flanges on the transfer lines, which have to support cycles of large thermal amplitude. The thermal protection of the engine provides a closed area, increasing the likelihood of an explosive atmosphere. Thus, even a small leak represents an unacceptable hazardous condition during loading operations, in flight, or after an aborted launch. Tapered fibers were first fabricated from 1/1.3-mm core/cladding (silica/ plastic) optical fibers. Typically a 1-ft (approx. 30- cm) section of the 1-mm fiber is cut from the bundle and marked with a pen into five 2-.-in. (.5.7-cm) sections. A propane torch is applied at every alternate mark to burn the jacket and soften the glass core. While the core is softening, the two ends of the fiber are pulled apart slowly to create fine tapers of .- to .-in. (.6- to 12-mm) long on the 1-mm optical fiber. Following this, the non-tapered ends of the fibers are polished to a 0.3-micron finish. Then these fibers were coated with indicators sensitive to hydrogen. The tapered hydrogen detection system with its unique flexibility is the only system that can be placed in many locations inside the vehicles and detect the exact location of leaks, saving millions of dollars for launch vehicle industries.

Goswami, Kisholoy↗

Adaptation of an In Situ Ground-Based Tropospheric OH/HO2 Instrument for Aircraft Use

In-situ HO(x) (OH and HO2) measurements are an essential part of understanding the photochemistry of aircraft exhaust in the atmosphere. HO(x) affects the partitioning of nitrogen species in the NO(y) family. Its reactions are important sources and sinks for tropospheric ozone, thus providing a link between the NO(x) in aircraft exhaust and tropospheric ozone. OH mixing ratios are enhanced in aircraft wakes due to the photolysis of the HONO that is made close to the engine. Measurements of HO(x) in aircraft wakes, along with NO(x) measurements, thus provides a constraint on chemical models of the engine combustion and exhaust. The development of the Airborne Tropospheric Hydrogen Oxides Sensor (ATHOS) is reported. We designed, developed, and successfully flew this instrument. It was part of the instrument complement on board the NASA DC-8 during SUCCESS, which took place in Kansas in April and May, 1996. ATHOS has a limit-of-detection for OH (S/N = 2) of 10(exp 5) OH molecules cm(exp -3) in less than 150 seconds. While this sensitivity is about 2-3 times less than the initial projections in the proposal, it is more than adequate for good measurements of OH and HO2 from the planetary boundary layer to the stratosphere. Our participation in SUCCESS was to be engineering test flights for ATHOS; however, the high-quality measurements we obtained are being used to study HO(x) photochemistry in contrails, clouds, and the clear air.

Brune, William H.↗

HOx Observation and Model Comparison During INTEX-A 2004

OH and HO2 were measured with the Airborne Tropospheric Hydrogen Oxides Sensor (ATHOS) as part of a large measurement suite from the NASA DC-8 aircraft during the Intercontinental Chemical Transport Experiment - A (INTEX-A). This mission, which was conducted mainly over North America and the western Atlantic Ocean in summer 2004, was an excellent test of atmospheric oxidation chemistry. Throughout the troposphere, observed OH was generally 0.60 of the modeled OH; below 8 km, observed HO2 was generally 0.78 of modeled HO2. If the over-prediction of tropospheric OH is not due to an instrument calibration error, then it implied less global tropospheric oxidation capacity and longer lifetimes for gases like methane and methyl chloroform than currently thought. This discrepancy falls well outside uncertainties in both the OH measurement and rate coefficients for known reactions and points to a large unknown OH loss. If the modeled OH is forced to agree with observed values by introducing of an undefined OH loss that removed HOx (HOx=OH+HO2), the observed and modeled HO2 and HO2/OH ratios are largely reconciled within the measurement uncertainty. HO2 behavior above 8 km was markedly different. The observed-to-modeled ratio correlating with NO. The observed-to-modeled HO2 ratio increased from approximately 1 at 8 km to more than approximately 2.5 at 11 km with the observed-to-modeled ratio correlating with NO. The observed-to-modeled HO2 and NO were both considerably greater than observations from previous campaigns. In addition, the observed-to-modeled HO2/OH, which is sensitive to cycling reactions between OH and HO2, increased from approximately 1.2 at 8 km to almost 4 above 11 km. In contrast to the lower atmosphere, these discrepancies above 8 km suggest a large unknown HOx source and additional reactants that cycle HOx from OH to HO2. In the continental planetary boundary layer, the OH observed-to-modeled ratio increased from 0.6 when isoprene was less than 0.1 ppbv to over 3 when isoprene was greater than 2 ppbv, suggesting that forests throughout the United States are emitting unknown HOx sources. Progress in resolving these discrepancies requires further examinations of possible unknown OH sinks and HOx sources and a focused research activity devoted to ascertaining the accuracy of the OH and HO2 measurements.

Ren, Xinrong↗

A SURVEY OF MASS AND LEVEL GAUGING TECHNIQUES FOR LIQUID HYDROGEN

Generally, liquid level sensors are used to determine the liquid mass or head in tank filling, holding, and propellant utilization systems for rocket vehicles, and also In storage Inventory and research applications. The latter two applications are so varied that they will not be discussed further. Tank filling and holding to a predetermined liquid mass require a flow control system that is maintained by a liquid level sensor. The sensor may be a continuous-reading type or a rake of point sensors located in the vicinity of the required level Propellant utilization systems control the relative flows of the liquid propellants so that, ideally, no propellant is left over at burnout. A liquid level sensing and control system monitors the liquid mass in each tank during outflow and corrects the relative propellant flows to obtain the desired result. The level sensor again may be either a continuous sensor or a rake of point sensors.

LIQUID HYDROGEN↗

STS-114: Discovery Post MMT Press Conference

This press conference focuses on the outcome of the Mission Management Team (MMT) meeting. The launch and status of the Space Shuttle Discovery is discussed. George Diller from NASA Public Affairs introduces the panel which consists of: Wayne Hale, Space Shuttle Program Deputy Manager and Mike Wetmore, Director of Space Shuttle Processing at Nasa Kennedy Space Center. The news media asks questions about the history of the low level sensors in the hydrogen tank, the cryogenic atmosphere around the sensors, troubleshooting, astronaut activities, possible rollback procedures.

Source record↗

"Un-annealed and Annealed Pd Ultra-Thin Film on SiC Characterized by Scanning Probe Microscopy and X-ray Photoelectron Spectroscopy"

Pd/SiC has been used as a hydrogen and a hydrocarbon gas sensor operated at high temperature. UHV (Ultra High Vacuum)-Scanning Tunneling Microscopy (STM), Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) techniques were applied to study the relationship between the morphology and chemical compositions for Pd ultra-thin films on SiC (less than 30 angstroms) at different annealing temperatures. Pd ultra-thin film on 6H-SiC was prepared by the RF sputtering method. The morphology from UHV-STM and AFM shows that the Pd thin film was well deposited on SiC substrate, and the Pd was partially aggregated to round shaped participates at an annealing temperature of 300 C. At 400 C, the amount of surface participates decreases, and some strap shape participates appear. From XPS, Pd2Si was formed on the surface after annealing at 300 C, and all Pd reacted with SiC to form Pd2Si after annealing at 400 C. The intensity of the XPS Pd peak decreases enormously at 400 C. The Pd film diffused into SiC, and the Schottky barrier height has almost no changes. The work shows the Pd sicilides/SiC have the same electronic properties with Pd/SiC, and explains why the Pd/SiC sensor still responds to hydrogen at high operating temperatures.

Lu, W. J.↗

SiC-Based Gas Sensors

Electronic grade Silicon Carbide (SiC) is a ceramic material which can operate as a semiconductor at temperatures above 600 C. Recently, SiC semiconductors have been used in Schottky diode gas sensor structures. These sensors have been shown to be functional at temperatures significantly above the normal operating range of Si-based devices. SiC sensor operation at these higher temperatures allows detection of gases such as hydrocarbons which are not detectable at lower temperatures. This paper discusses the development of SiC-based Schottky diode gas sensors for the detection of hydrogen, hydrocarbons, and nitrogen oxides (NO(x)). Sensor designs for these applications are discussed. High sensitivity is observed for the hydrogen and hydrocarbon sensors using Pd on SiC Schottky diodes while the NO(x) sensors are still under development. A prototype sensor package has been fabricated which allows high temperature operation in a room temperature ambient by minimizing heat loss to that ambient. It is concluded that SiC-based gas sensors have considerable potential in a variety of gas sensing applications.

Chen, Liang-Yu↗

Microfabricated Chemical Sensors for Safety and Emission Control Applications

Chemical sensor technology is being developed for leak detection, emission monitoring, and fire safety applications. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication (MicroElectroMechanical Systems (MEMS)-based) technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Using these technologies, sensors to measure hydrogen, hydrocarbons, nitrogen oxides, carbon monoxide, oxygen, and carbon dioxide are being developed. A description is given of each sensor type and its present stage of development. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, G. W.↗

Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, and fire detection. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors; 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity; 3) The development of high temperature semiconductors, especially silicon carbide. This presentation discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, Gary W.↗

Development of Microfabricated Chemical Gas Sensors and Sensor Arrays for Aerospace Applications

Aerospace applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. In particular, factors such as minimal sensor size, weight, and power consumption are particularly important. Development areas which have potential aerospace applications include launch vehicle leak detection, engine health monitoring, fire detection, and environmental monitoring. Sensor development for these applications is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. However, due to issues of selectivity and cross-sensitivity, individual sensors are limited in the amount of information that they can provide in environments that contain multiple chemical species. Thus, sensor arrays are being developed to address detection needs in such multi-species environments. This paper discusses the needs of space applications as well as the point-contact sensor technology and sensor arrays being developed to address these needs. Sensors to measure hydrogen, hydrocarbons, hydrazine, nitrogen oxides (NO,), carbon monoxide, oxygen, and carbon dioxide are being developed as well as arrays for leak, fire, and emissions detection. Demonstrations of the technology will also be discussed. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

Hunter, G. W.↗

Gas Permeable Chemochromic Compositions for Hydrogen Sensing

A (H2) sensor composition includes a gas permeable matrix material intermixed and encapsulating at least one chemochromic pigment. The chemochromic pigment produces a detectable change in color of the overall sensor composition in the presence of H2 gas. The matrix material provides high H2 permeability, which permits fast permeation of H2 gas. In one embodiment, the chemochromic pigment comprises PdO/TiO2. The sensor can be embodied as a two layer structure with the gas permeable matrix material intermixed with the chemochromic pigment in one layer and a second layer which provides a support or overcoat layer.

Bokerman, Gary↗

STS-114: Discovery Launch Postponement Press Briefing

This press briefing addresses the problem that occurred prior to the launch of the STS-114. Dean Acosta, Deputy Assistant Administrator of Public Affairs, introduces the panel which consists of Dr. Michael Griffin, NASA Administrator, William Readdy, Associate Administrator for Space Operations, Wayne Hale, Space Shuttle Program Deputy Manager, Steve Poulas, Orbiter Project Manager, Mike Leinbach, NASA Launch Director, and Bill Parsons, Space Shuttle Program Manager. Wayne Hale expresses that a problem occurred with one of the low level sensors in the hydrogen tank and that the cause of the problem must be identified and rectified. Steve Poulos talks about establishing a troubleshooting plan as a part of the scrub effort and Mike Leinbach describes the process of draining the external tank. Wayne Hale answers questions about the sensors and if the Space Shuttle Discovery is safe to fly and Steve Poulos answers questions about the possible suspects for this problem.

Source record↗

Using Si Diodes To Detect H2 Liquid/Vapor Interfaces

Commercially available silicon-diode temperature sensors used to detect interfaces between hydrogen liquid and hydrogen vapor at steady-state saturation conditions. Sensors mounted at short intervals along rod to form rake-like array. Array inserted in tank with rod oriented vertically, where it senses level of liquid hydrogen to resolution equal to interval between sensors. Basic idea to measure voltage across sensor while supplying small electric current that heats sensor. Because vapor cools sensor less effectively than liquid does, sensor's steady-state temperature greater when sensor surrounded by vapor than when immersed in liquid. Voltage output decreases as temperature increases for silicon diodes. Thus, temperature (voltage) reading used to determine whether liquid level above or below sensor.

Dempsey, Paula Jean↗

Sniffer used as portable hydrogen leak detector

Sniffer type portable monitor detects hydrogen in air, oxygen, nitrogen, or helium. It indicates the presence of hydrogen in contact with activated palladium black by a change in color of a thermochromic paint, and indicates the quantity of hydrogen by a sensor probe and continuous readout.

Dayan, V. H.↗

Goddard Geophysical and Astronomical Observatory

This report summarizes the technical parameters and the technical staff of the VLBI system at the fundamental station GGAO. It also gives an overview about the VLBI activities during the report year. The Goddard Geophysical and Astronomical Observatory (GGAO) consists of a 5-meter radio telescope for VLBI, a new 12-meter radio telescope for VLBI2010 development, a 1-meter reference antenna for microwave holography development, an SLR site that includes MOBLAS-7, the NGSLR development system, and a 48" telescope for developmental two-color Satellite Laser Ranging, a GPS timing and development lab, a DORIS system, meteorological sensors, and a hydrogen maser. In addition, we are a fiducial IGS site with several IGS/IGSX receivers. GGAO is located on the east coast of the United States in Maryland. It is approximately 15 miles NNE of Washington, D.C. in Greenbelt, Maryland.

Figueroa, Ricardo↗

Slush hydrogen liquid level system

A discrete capacitance liquid level system developed is specifically for slush hydrogen, but applicable to LOX, LN2, LH2, and RP1 without modification is described. The signal processing portion of the system is compatible with conventional liquid level sensors. Compatibility with slush hydrogen was achieved by designing the sensor with adequate spacing, while retaining the electrical characteristics of conventional sensors. Tests indicate excellent stability of the system over a temperature range of -20 C to 70 C for the circuit and to cryogenic temperatures of the sensor. The sensor was tested up to 40 g's rms random vibration with no damage to the sensor. Operation with 305 m of cable between the sensor and signal processor was demonstrated. It is concluded that this design is more than adequate for most flight and ground applications.

Hamlet, J. F.↗