Recombination of Hydrogen in the Iodine Reactors

The H-Canyon facility is currently dissolving spent nuclear fuel, including Material Test Reactor (MTR) and High Flux Isotope Reactor (HFIR) fuel. Dissolution of aluminum spent nuclear fuel produces hydrogen and other NOx gases. A theory long held by H-Canyon Engineering and Facility Technical Advisors that the silver nitrate-coated berl saddles, present in the iodine reactor, used for off-gas treatment were acting as a catalytic hydrogen recombiner was captured during an external review of the Accelerated Basin Deinventory program. Results from a separate SRNL project using a Raman Spectrometer to monitor the offgas from the dissolution process indicated a lack of the expected hydrogen in the off-gas stream. To test this hypothesis, a laboratory scale iodine reactor was assembled and filled with silver nitrate-coated berl saddles. Testing with this laboratory scale reactor confirmed the recombination of hydrogen when a simulated dissolver off-gas was passed through the reactor containing silver nitrate-coated berl saddles at 173-188 °C. Control experiments performed with uncoated berl saddles resulted in no change to the hydrogen concentration after passing through the reactor. The residence time of the gas in the reactor was varied to determine if residence time had an impact on the amount of hydrogen recombination occurring. Results from these experiments indicated that at the shortest residence times tested (~5 seconds) recombination of the hydrogen still exceeded 90%; however, the percent recombination did increase at longer residence times, reaching 97.9% or greater for residence times over 10 seconds. Finally, testing performed with a simplified off-gas composition containing only hydrogen and air gave similar results, indicating that the presence of NO and N 2 O gases in the stream do not play a role in the recombination reaction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen chloride measurements in the Space Shuttle exhaust cloud - First launch, April 12, 1981

Partitioning of hydrogen chloride between the aerosol and gaseous phases in the first Space Shuttle exhaust cloud was experimentally investigated as the exhaust cloud was diluted with ambient air. Airborne measurements were obtained of gaseous hydrogen chloride (HCl), total HCl, relative humidity, and temperature to determine the conditions controlling HCl aerosol formation in the Shuttle exhaust cloud. Two segments of the cloud, each at a significantly different relative humidity, were monitored. Equilibrium predictions of HCl aerosol formation agreed with the measured HCl partitioning at the higher and lower relative humidity conditions, but do not agree at the aerosol formation threshold region. Measurements were taken in the Shuttle exhaust cloud from 8.6 min until 2 h and 8 min after launch. HCl concentrations ranged from 17.5 to 0.9 ppm and relative humidity from 86% to less than 10%.

Sebacher, D. I.↗

Lightweight, direct-radiating nickel hydrogen batteries

Two battery module configurations were developed which, in addition to integrating cylindrical nickel hydrogen (NiH2) cells into batteries, provide advances in the means of mounting, monitoring and thermal control of these cells. The main difference between the two modules is the physical arrangement of the cells: vertical versus horizontal. Direct thermal radiation to deep space is accomplished by substituting the battery structure for an exterior spacecraft panel. Unlike most conventional nickel-cadmium (NiCd) and NiH2 batteries, the cells are not tightly packed together; therefore ancillary heat conducting media to outside radiating areas, and spacecraft deck reinforcements for high mass concentration are not necessary. Testing included electrical characterization and a comprehensive regime of environmental exposures. The designs are flexible with respect to quantity and type of cells, orbit altitude and period, power demand profile, and the extent of cell parameter monitoring. This paper compares the characteristics of the two battery modules and summarizes their performance.

Metcalfe, J. R.↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

Development of a six-man, self-contained carbon dioxide collection subsystem for spacecraft application

Life Systems, working with NASA, has developed an electrochemical, six-man, self-contained carbon dioxide concentrator subsystem (CX-6) designed to normally remove 13.2 lb/day of CO2 while maintaining the CO2 partial pressure (pCO2) of the cabin atmosphere at 3 mm Hg or less. The CX-6 was subjected to extensive parametric and endurance testing. The effects of operating conditions on CO2 removal and electrical efficiencies were determined, including effects of hydrogen (H2) flow rate, process airflow rate, pCO2, operating temperature and current density. A total of 209 days of operation was accumulated. The subsystem was designed with self-contained electronic control and monitoring instrumentation. The CX-6 was redesigned and repackaged into the CO2 collection subsystem for the air revitalization group of the space station prototype.

Schubert, F. H.↗

Microcalorimetric Measurements of Hydrogen Peroxide Stability

Recent interest in propellants with nontoxic reaction products has led to a resurgence of interest in hydrogen peroxide for various propellant applications. Because hydrogen peroxide is sensitive to contaminants and materials interactions, stability and shelf life are issues. A relatively new, ultrasensitive heat measurement technique, isothermal microcalorimetry, is being used at the White Sands Test Facility to monitor the decomposition of hydrogen peroxide at near ambient temperatures. Isothermal microcalorimetry measures the beat flow from a reaction vessel into a surrounding heat sink. In these applications, microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry or differential scanning calorimetry for measuring thermal events. Experimental procedures have been developed for the microcalorimetric measurement of the ultra-small beat effects caused by incompatible interactions of hydrogen peroxide. The decomposition rates of hydrogen peroxide at the picomole/sec/gram level have been measured showing the effects of stabilizers and peroxide concentration. Typical measurements are carried out at 40 C over a 24-hour period, This paper describes a method for the conversion of the heat flow measurements to chemical reaction rates based on thermochemical considerations. The reaction rates are used in a study of the effects of stabilizer levels on the decomposition of propellant grade hydrogen peroxide.

Davis, Dennis D.↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crewmembers will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crewmember breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements during the beginning of and throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests, with each test lasting 2.5 hours and involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry Laboratory at the NASA Lyndon B. Johnson Space Center. The majority of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, and acetaldehyde. A fire cartridge is exposed to the test gas in a test chamber at the specified conditions and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work, then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the conduction of the challenge tests, a general summary of the performance of the fire cartridges will be provided.

Fire Cartridge↗

Chemical Challenge Tests on ISS Fire Cartridges

Following a confirmed combustion event onboard the International Space Station (ISS), crew members will don Emergency Masks, each fitted with 2 ISS fire cartridge filters. As the crew member breathes through the filters, combustion products in the cabin air are either filtered or catalyzed by the fire cartridge media to minimize crew exposure to harmful levels of contaminants. Rigorous certification, acceptance, and surveillance programs for the fire cartridges ensure that each lot meets stringent performance requirements throughout the service life of the cartridges. In accordance with the Quality/Acceptance Test Plan, multiple fire cartridges from each lot undergo chemical challenge tests involving one or more chemicals at specified concentrations. These tests are conducted at specific temperatures, humidity levels, and gas flow rates intended to mimic the worst-case conditions for fire cartridge performance. These challenge tests are conducted by the Environmental Chemistry- Laboratory at the NASA Lyndon B. Johnson Space Center. Many of the challenge tests focus on carbon monoxide (CO), but other gases include hydrogen cyanide (HCN), hydrogen chloride (HCl), cyclohexane, acrolein, ammonia (NH3), and acetaldehyde. A fire cartridge is exposed to the test gas in a chamber at the specified conditions, and the outlet is monitored for breakthrough during the 2.5-hour test. This paper will briefly introduce fire cartridges and how they work and will then discuss details of the challenge gas delivery and exposure system, breakthrough monitoring methods, and discussion of issues that have arisen during the course of the test program. Although the focus of this paper will be on the challenge tests, a general summary of the performance of the fire cartridges will also be provided.

Cristina M. Muko↗

Dehalogenation of Chlorinated Ethenes to Ethene by a Novel Isolate, “ Candidatus Dehalogenimonas etheniformans”

Dehalococcoides mccartyi strains harboring vinyl chloride (VC) reductive dehalogenase (RDase) genes are keystone bacteria for VC detoxification in groundwater aquifers, and bioremediation monitoring regimens focus on D. mccartyi biomarkers. We isolated a novel anaerobic bacterium, “Candidatus Dehalogenimonas etheniformans” strain GP, capable of respiratory dechlorination of VC to ethene. This bacterium couples formate and hydrogen (H2) oxidation to the reduction of trichloro-ethene (TCE), all dichloroethene (DCE) isomers, and VC with acetate as the carbon source. Cultures that received formate and H2 consumed the two electron donors concomitantly at similar rates. A 16S rRNA gene-targeted quantitative PCR (qPCR) assay measured growth yields of (1.2 ± 0.2) × 10 8 and (1.9 ± 0.2) × 10 8 cells per μmol of VC dechlorinated in cultures with H 2 or formate as electron donor, respectively. About 1.5-fold higher cell numbers were measured with qPCR targeting cerA, a single-copy gene encoding a putative VC RDase. A VC dechlorination rate of 215 ± 40 μmol L -1 day -1 was measured at 30°C, with about 25% of this activity occurring at 15°C. Increasing NaCl concentrations progressively impacted VC dechlorination rates, and dechlorination ceased at 15 g NaCl L -1 . During growth with TCE, all DCE isomers were intermediates. Tetrachloroethene was not dechlorinated and inhibited dechlorination of other chlorinated ethenes. Carbon monoxide formed and accumulated as a metabolic by-product in dechlorinating cultures and impacted reductive dechlorination activity. Finally, the isolation of a new Dehalogenimonas species able to effectively dechlorinate toxic chlorinated ethenes to benign ethene expands our understanding of the reductive dechlorination process, with implications for bioremediation and environmental monitoring.

59 BASIC BIOLOGICAL SCIENCES↗

Composite Cryotank Technologies and Development 2.4 and 5.5M out of Autoclave Tank Test Results

The Composite Cryotank Technologies and Demonstration (CCTD) project substantially matured composite, cryogenic propellant tank technology. The project involved the design, analysis, fabrication, and testing of large-scale (2.4-m-diameter precursor and 5.5-m-diameter) composite cryotanks. Design features included a one-piece wall design that minimized tank weight, a Y-joint that incorporated an engineered material to alleviate stress concentration under combined loading, and a fluted core cylindrical section that inherently allows for venting and purging. The tanks used out-of-autoclave (OoA) cured graphite/epoxy material and processes to enable large (up to 10-m-diameter) cryotank fabrication, and thin-ply prepreg to minimize hydrogen permeation through tank walls. Both tanks were fabricated at Boeing using automated fiber placement on breakdown tooling. A fluted core skirt that efficiently carried axial loads and enabled hydrogen purging was included on the 5.5-m-diameter tank. Ultrasonic inspection was performed, and a structural health monitoring system was installed to identify any impact damage during ground processing. The precursor and 5.5-m-diameter tanks were tested in custom test fixtures at the National Aeronautics and Space Administration Marshall Space Flight Center. The testing, which consisted of a sequence of pressure and thermal cycles using liquid hydrogen, was successfully concluded and obtained valuable structural, thermal, and permeation performance data. This technology can be applied to a variety of aircraft and spacecraft applications that would benefit from 30 to 40% weight savings and substantial cost savings compared to aluminum lithium tanks.

Jackson, Justin R.↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Effect of alcohol addition on shock-initiated formation of soot from benzene

Soot formation in benzene-methanol and benzene-ethanol argon-diluted mixtures was studied behind reflected shock waves by monitoring the attenuation of an He-Ne laser beam. The experiments were performed at temperatures 1580-2250 K, pressures 2.0-3.0 bar, and total carbon atom concentrations (2.0-2.7) x 10 to the 17th atoms/cu cm. The results obtained indicate that the addition of alcohol suppresses the formation of soot from benzene at all temperatures, and that the reduction in soot yields is increased with the amount of alcohol added. The analysis of the results indicates that the suppression effect is probably due to the oxidation of soot and soot precursors by OH and the removal of hydrogen atoms by alcohol and water molecules.

Frenklach, Michael↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Pilot-scale hydrotreating of catalytic fast pyrolysis biocrudes: process performance and product analysis

Catalytic fast pyrolysis (CFP) is a technology option for producing advanced biofuels from hydrocarbon-rich biocrude intermediates. The relatively high oxygen content of biocrudes compared to petroleum intermediates increases hydrogen consumption and the lower thermal stability accelerates catalyst deactivation and reactor fouling hindering the adaptation of hydrotreating technology for biocrude upgrading into biofuels. In this study, four chemically different biocrude feeds were upgraded in a pilot scale hydroprocessing unit at similar process conditions using a commercial hydrodeoxygenation (HDO) catalyst. The biocrude feeds and hydrotreated products were characterized using standard ASTM procedures and advanced analytical techniques (GCxGC-FID and GCxGC-MS). HDO catalyst activity was monitored by changes in physical properties and chemical composition of the upgraded products as a function of time on stream. Aliphatic acids, ketones, aldehydes, and furan derivatives were completely converted during the hydrotreating tests while the concentration of aromatics, aliphatic hydrocarbons and phenolics increased during the hydrotreating tests. The oxygen content, nitrogen content, specific gravity, viscosity and the heavy end of the boiling point range (determined by simulated distillation) of the upgraded products increased with increasing time on stream during hydrotreating. The deactivation rate was the lowest for the biocrude feed that contained the most aliphatic and aromatic hydrocarbons and was the highest for the biocrude feed that had the most anhydrosugars. Overall, the HDO deactivation rate correlates with the total amount of oxygen in the feed (17 wt% to 29 wt%, on a wet basis).

09 BIOMASS FUELS↗

Hydrogen isotope analysis in W-tiles using fs-LIBS

Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the applicability of using the triple redundant hydrogen sensor for methane sensing

Application specifications for the methane sensor were assembled and design guidelines, development goals and evaluation criteria were formulated. This was done to provide a framework to evaluate sensor performance and any design adjustments to the preprototype sensor that could be required to provide methane sensitivity. Good response to hydrogen was experimentally established for four hydrogen sensor elements to be later evaluated for methane response. Prior results were assembled and analyzed for other prototype hydrogen sensor performance parameters to form a comparison base. The four sensor elements previously shown to have good hydrogen response were experimentally evaluated for methane response in 2.5% methane-in-air. No response was obtained for any of the elements, despite the high methane concentration used (50% of the Lower Flammability Limit). It was concluded that the preprototype sensing elements were insensitive to methane and were hydrogen specific. Alternative sensor operating conditions and hardware design changes were considered to provide methane sensitivity to the preprototype sensor, including a variety of different methane sensing techniques. Minor changes to the existing sensor elements, sensor geometry and operating conditions will not make the preprototype hydrogen sensor respond to methane. New sensor elements that will provide methane and hydrogen sensitivity require replacement of the existing thermistor type elements. Some hydrogen sensing characteristics of the modified sensor will be compromised (larger in situ calibration gas volume and H2 nonspecificity). The preprototype hydrogen sensor should be retained for hydrogen monitoring and a separate methane sensor should be developed.

Lantz, J. B.↗

Hydrocarbon polymeric binder for advanced solid propellant

A series of DEAB initiated isoprene polymerizations were run in the 5-gallon stirred autoclave reactor. Polymerization run parameters such as initiator concentration and feed rate were correlated with the molecular weight to provide a basis for molecular weight control in future runs. Synthetic methods were developed for the preparation of n-1,3-alkadienes. By these methods, 1,3-nonadiene was polymerized using DEAB initiator to give an ester-telechelic polynonadiene. This was subsequently hydrogenated with copper chromite catalyst to give a hydroxyl terminated saturated liquid hydrocarbon prepolymer having greatly improved viscosity characteristics and a Tg 18 degrees lower than that of the hydrogenated polyisoprenes. The hydroxyl-telechelic saturated polymers prepared by the hydrogenolysis of ester-telechelic polyisoprene were reached with diisocyanates under conditions favoring linear chain extension gel permeation chromatography was used to monitor this condensation polymerization. Fractions having molecular weights above one million were produced.

Potts, J. E.↗

A survey of laser and selected optical systems for remote measurement of pollutant gas concentrations

Applications of the Differential Absorption Lidar (DIAL) technique to the remote sensing of pollutant gases are surveyed. In the DIAl technique, the differential absorption of two laser beams reflected back to a receiver from a target determines the concentration of the gas being studied. The types of instruments available are considered in detail: dye lidar (to measure nitrogen dioxide, sulfur dioxide, and ozone); carbon dioxide laser (for ozone, ethylene, ammonia, and hydrazine), helium-neon laser (for methane); hydrogen fluoride laser (for HF); and tunable diode laser (for nitric oxide and carbon monoxide). DIAL instruments are compared with other optical remote sensors such as Fourier-transform infrared spectrometers, correlation spectrometers (COSPEC and GASPEC), and grating spectrometers; and criteria for the selection of an appropriate gas measuring system are suggested. Laser and other optical remote sensors are found to be cost effective in many cases, despite the fact that they are more costly than point-monitoring systems.