Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hodoscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Detection of High Energy Cosmic Rays with Advanced Thin Ionization Calorimeter, ATIC

The author presents preliminary results of the first flight of the Advanced Thin Ionization Calorimeter (ATIC). ATIC is a multiple, long duration balloon flight, investigation for the study of cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pads capable of charge identification of cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction 'target'.

Adams, J. H.↗

Detection of High Energy Cosmic Ray with the Advanced Thin Ionization Calorimeter (ATIC)

ATIC is a balloon-borne investigation of cosmic ray spectra, from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Gemmate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pixels capable of charge identification in cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction 'target'. Very high energy gamma-rays and their energy spectrum may provide insight to the flux of extremely high energy neutrinos which will be investigated in detail with several proposed cubic kilometer scale neutrino observatories in the next decade.

Fazely, Ali R.↗

The ATIC Long Duration Balloon Project

Long Duration Balloon (LDB) scientific experiments, launched to circumnavigate the south pole over Antarctica, have particular advantages compared to Shuttle or other Low Earth Orbit (LEO) missions in terms of cost, weight, scientific 'duty factor' and work force development. The Advanced Thin Ionization Calorimeter (ATIC) cosmic ray astrophysics experiment is a good example of a university-based project that takes full advantage of current LDB capability. The ATIC experiment is currently being prepared for its first LDB science flight that will investigate the charge composition and energy spectra of primary cosmic rays over the energy range from about 10(exp 10) to 10(exp 14) eV. The instrument is built around a fully active, Bismuth Germanate (BGO) ionization calorimeter to measure the energy deposited by the cascades formed by particles interacting in a thick carbon target. A highly segmented silicon matrix, located above the target, provides good incident charge resolution plus rejection of the 'backscattered' particles from the interaction. Trajectory reconstruction is based on the cascade profile in the BGO calorimeter, plus information from the three pairs of scintillator hodoscope layers in the target section above it. A full evaluation of the experiment was performed during a test flight occurring between 28 December 2000 and 13 January 2001 where ATIC was carried to an altitude of approx. 37 km above Antarctica by an approx. 850,000 cu m helium filled balloon for one circumnavigation of the continent. All systems behaved well, the detectors performed as expected, more than 43 gigabytes of engineering and cosmic ray event data was returned and these data are now undergoing preliminary data analysis. During the coming 2002-2003 Antarctica summer season, we are preparing for a ATIC science flight with approx. 15 to 30 days of continuous data collection in the near-space environment of LDB float altitudes.

Guzik, T. G.↗

Experience of Application of Silicon Matrix as a Charge Detector in the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) was built for series of long-duration balloon flights in Antarctica. Its main goal is to measure energy spectra of cosmic ray nuclei from protons up to iron nuclei in the wide range of their energy from 30 GeV up to 100 TeV. The ATIC balloon experiment had its first, test flight that lasted for 16 days from 28 Dec 2000 to 13 Jan 2001 around the South Pole. The ATIC spectrometer consists of a fully active BGO calorimeter, scintillator hodoscopes and a silicon matrix. The silicon matrix consisted of 4480 pixels was used as a charge detector in the experiment. About 25 million cosmic ray events were detected during the flight. In the paper, the charge spectrum obtained with the silicon matrix is analyzed.

Zatsepin, V. I.↗

Relative Abundances and Energy Spectra of C, N, and 0 as Measured by the Advanced Thin Ionization Calorimeter Balloon Experiment

We present results on the spectra and the relative abundances of C, N, and 0 nuclei in the cosmic radiation as measured from the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) . The ATIC detector has completed two successful balloon flights from McMurdo, Antarctica lasting a total of more than 35 days. ATIC is designed as a multiple, long duration balloon flight, investigation of the cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate calorimeter. It is equipped with a large area mosaic of silicon detector pixels capable of charge identification from H to Fe. As a redundancy check for the charge identification and a particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the middle and below a 0.75 nuclear interaction length graphite target.

Fazely, A. R.↗

Atic Experiment: Flight Data Processing

The Advanced Thin Ionization Calorimeter (ATIC) is a balloon borne experiment to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range approx. 30 GeV - 100 TeV. The instrument consists of a fully active 320-crystal Bismuth Germanate (BGO) calorimeter, 202 scintillator strips in 3 hodoscopes interleaved with a graphite target, and a 4480-pixel silicon matrix charge detector. ATIC has had two successful Long Duration Balloon flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We have developed the ATIC Data Processing System (ADPs), which is an Object Oriented data processing program based on ROOT. In this paper, we describe the processing scheme used in handling the flight data, especially the calibration method and the event reconstruction algorithm.

Ahn, H. S.↗

ATIC Experiment: Preliminary Results from the Flight in 2002

Abstract The Advanced Thin Ionization Calorimeter (ATIC) had successful Long Duration Balloon flights from McMurdo, Antarctica in both 2000 and 2002. The instrument consists of a Silicon matrix for charge measurement, a flared graphite target to induce nuclear interactions, scintillator strip hodoscopes for triggering and helping reconstruct trajectory, and a BGO calorimeter to measure the energy of incident particles. In this paper, we discuss the second flight, which lasted 20 days, starting on 12/29/02. Preliminary results from the on-going analysis of the data including the proton and helium spectra are reported.

Ahn, H. S.↗

ATIC Experiment: Elemental Spectra from the Flight in 2000

The Advanced Thin Ionization Calorimeter (ATIC) had successful Long Duration Balloon flights from McMurdo, Antarctica in both 2000 and 2002. The instrument consists of a silicon matrix charge detector, a 0.75 nuclear interaction length graphite target, 3 scintillator strip hodoscopes, and an 18 radiation length thick BGO calorimeter to measure the cosmic ray composition and energy spectra from approximately 30 GeV to near 100 TeV. In this paper, we present preliminary results from the first flight, which was a test flight that lasted for 16 days, starting on 12/28/00.

Ahn, H. S.↗

Rigidity Spectra of Protons and Helium as Measured in the First Flight of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure cosmic ray composition for elements from hydrogen to iron and their energy spectra from 30 GeV to near 100 TeV. It is comprised of a fully active BGO calorimeter, a carbon interaction target, scintillator hodoscopes, and a silicon matrix that is used as a charge detector in the experiment. ATIC had two successful balloon flights in Antarctica: from 28 Dec 2000 to 13 Jan 2001 (ATIC-1) and from 29 Dec 2002 to 18 Jan 2003 (ATIC-2). Preliminary rigidity spectra of protons and helium nuclei and their ratio are presented for the test flight (ATIC-1). Particular attention is given to problems associated with measuring energy.

Zatsepin, V. I.↗

The Silicon Matrix as a Charge Detector in the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) was built for series of long- duration balloon flights in Antarctica. Its main goal is to measure energy spectra of cosmic ray nuclei from protons up to iron nuclei over a wide energy range from 30 GeV up to 100 TeV. The ATIC balloon experiment had its first, test flight that lasted for 16 days from 28 Dec 2000 to 13 Jan 2OO1 around the continent. The ATIC spectrometer consists of a fully active BGO calorimeter, scintillator hodoscopes and a silicon matrix. The silicon matrix, consisting of 4480 pixels, was used as a charge detector in the experiment. About 25 million cosmic ray events were detected during the flight. In the paper, the charge spectrum obtained with the silicon matrix is analyzed.

Zatsepin, V. I.↗

The Energy Spectra of Heavy Nuclei Measured by the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon-borne experiment to measure the spectra and composition of primary cosmic rays in the region of total energy from 100 GeV to near 100 TeV for Z from 1 to 26. ATIC consists of a pixelated silicon matrix detector to measure charge plus a fully active BGO calorimeter, to measure energy, located below a carbon target interleaved with three layers of scintillator hodoscope. The ATIC instrument had a second (scientific) flight from McMurdo, Antarctica from 12/29/02 to 1/18/03, yielding 20 days of good data. The GEANT 3.21 Monte Carlo code with the QGSM event generator and the FLUKA code with the DPMJET-II event generator were used to convert energy deposition measurements to primary energy. We present the preliminary energy spectra for the abundant elements C, O, Ne, Mg, Si and Fe and compare them with the results of the first (test) flight of ATIC in 2000-01 and with results from the HEAO-3 and CRN experiments.

Panov, A. D.↗

The Energy Spectra of Proton and Helium Measured from the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon experiment is designed to investigate the composition and energy spectra of cosmic rays at the highest energies currently accessible from direct measurements, the region up to 100 TeV. The instrument consists of a silicon matrix for charge measurement, a graphite target (0.75 nuclear interaction length) to induce hadronic fragmentation, 3 scintillator strip hodoscopes for triggering and helping reconstruct trajectory, and a BGO calorimeter (18 radiation lengths) to measure the energy of incident particles. ATIC had two successful Long Duration Balloon (LDB) flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We present the energy spectra of proton and helium extracted from the ATIC flights, over the energy range from 100 GeV to 100 TeV, and compare them with the results from other experiments at both the lower and higher energy ends.

Ahn, H. S.↗

Elemental Spectra from the First ATIC Flight

The Advanced Thin Ionization Calorimeter (ATIC) instrument is a balloon-borne experiment designed to measure the composition and energy spectra of Z = l to 26 cosmic rays over the energy range from approx. 10(exp 11) to approx. 10(exp 14) eV. The instrument consists of a silicon matrix charge detector, plastic scintillator strip hodoscopes interleaved with graphite interaction targets, and a fully active Bismuth Germanate (BGO) calorimeter. ATIC had two successful Long Duration Balloon flights launched from McMurdo Station, Antarctica in 2000 and 2002. In this paper, spectra of various elements measured during the first 16 day flight are presented.

Ahn, H. S.↗

Revised Energy Spectra for Primary Elements, H - Si, above 50 GeV from the ATIC-2 Science Flight

The Advanced Thin Ionization Calorimeter (ATIC) long duration balloon experiment had a successful science flight accumulating 18 days of data (12/02 - 1/03) during a single circumnavigation in Antarctica. ATIC measures the energy spectra of elements from H to Fe in primary cosmic rays using a fully active Bismuth Germanate calorimeter preceded by a carbon target, with embedded scintillator hodoscopes, and a silicon matrix charge detector at the top. Preliminary results from ATIC have been reported in previous conferences. The revised results reported here are derived from a new analysis of the data with improved charge resolution, lower background and revised energy calibration. The raw energy deposit spectra are de-convolved into primary energy spectra and extrapolated to the top of the atmosphere. We compare these revised results to previous data and comment upon the astrophysical interpretation of the results.

Wefel, J. P.↗

All-Particle Spectrum Measured by the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC), a balloon-borne experiment, is designed to investigate the composition and energy spectra of cosmic rays of charge Z = 1 to 26 over the energy range - 10(exp 11) - 10(exp 14) ev. The instrument consists of a silicon matrix charge detector, plastic-scintillator strip hodoscopes interleaved with graphite interaction targets, and an 18 radiation length deep, fully active bismuth germanate (BGO) calorimeter. ATIC has had two successful long duration balloon (LDB) flights launched from McMurdo Station, Antarc't'ica in 2000 and 2002. In this paper, we present the all-particle spectrum extracted from data collected during the ATIC flights, and compare it with results from other experiments at both lower and higher energies.

Ahn, H. S.↗

The Energetic Trans-Iron Nuclei Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)" which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.3 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of ~20 m2sr. Measurements made in space for a period of 3 years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized heavy elements (Pu and Cm), what the age of that component is, and test the model of the OB association origin of galactic cosmic rays. Additionally, it will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas.

Binns, W. R.↗

The Energetic Trans-Iron Cosmic-ray Experiment (ENTICE)

The ENTICE experiment is one of two instruments that comprise the "Orbiting Astrophysical Spectrometer in Space (OASIS)", which is presently undergoing a NASA "Astrophysics Strategic Mission Concept Study". ENTICE is designed to make high precision measurements of the abundances of individual elements from neon through the actinides and, in addition, will search for possible superheavy nuclei in the galactic cosmic rays. The ENTICE instrument utilizes silicon detectors, aerogel and acrylic Cherenkov counters, and a scintillating optical fiber hodoscope to measure the charge and energy of these ultra-heavy nuclei for energies greater than 0.5 GeV/nucleon. It is a large instrument consisting of four modules with a total effective geometrical factor of approx.20 sq m sr. Measurements made in space for a period of three years with ENTICE will enable us to determine if cosmic rays include a component of recently synthesized transuranic elements (Pu-94 and Cm-96), to measure the age of that component, and to test the model of the OB association origin of galactic cosmic rays. Additionally, these observations will enable us to study how diffusive shock acceleration of cosmic rays operates differently on interstellar grains and gas. Keywords: cosmic rays Galaxy:abundances

Binns, W. R.↗

Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

Link, Jason↗